ABSTRACT
BACKGROUND: Biodegradable polymer sirolimus-eluting stents improve early stent-related clinical outcomes compared to durable polymer everolimus-eluting stents in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The long-term advantages of biodegradable polymer sirolimus-eluting stents after complete degradation of its polymer coating in patients with STEMI remains however uncertain. METHODS: BIOSTEMI Extended Survival (BIOSTEMI ES) was an investigator-initiated, follow-up extension study of the BIOSTEMI prospective, multicentre, single-blind, randomised superiority trial that compared biodegradable polymer sirolimus-eluting stents with durable polymer everolimus-eluting stents in patients with STEMI undergoing primary percutaneous coronary intervention at ten hospitals in Switzerland. All individuals who had provided written informed consent for participation in the BIOSTEMI trial were eligible for this follow-up study. The primary endpoint was target lesion failure, defined as a composite of cardiac death, target vessel myocardial re-infarction, or clinically indicated target lesion revascularisation, at 5 years. Superiority of biodegradable polymer sirolimus-eluting stents over durable polymer everolimus-eluting stents was declared if the Bayesian posterior probability for a rate ratio (RR) of less than 1 was greater than 0·975. Analyses were performed according to the intention-to-treat principle. The study was registered with ClinicalTrials.gov, NCT05484310. FINDINGS: Between April 26, 2016, and March 9, 2018, 1300 patients with STEMI (1622 lesions) were randomly allocated in a 1:1 ratio to treatment with biodegradable polymer sirolimus-eluting stents (649 patients, 816 lesions) or durable polymer everolimus-eluting stents (651 patients, 806 lesions). At 5 years, the primary composite endpoint of target lesion failure occurred in 50 (8%) patients treated with biodegradable polymer sirolimus-eluting stents and in 72 (11%) patients treated with durable polymer everolimus-eluting stents (difference of -3%; RR 0·70, 95% Bayesian credible interval 0·51-0·95; Bayesian posterior probability for superiority 0·988). INTERPRETATION: In patients undergoing primary percutaneous coronary intervention for STEMI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 5 years of follow-up. The difference was driven by a numerically lower risk for ischaemia-driven target lesion revascularisation. FUNDING: Biotronik.
Subject(s)
Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Sirolimus/therapeutic use , Everolimus/therapeutic use , Follow-Up Studies , ST Elevation Myocardial Infarction/surgery , ST Elevation Myocardial Infarction/drug therapy , Polymers , Bayes Theorem , Single-Blind Method , Prospective Studies , Treatment Outcome , Absorbable Implants , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/methodsABSTRACT
BACKGROUND: Whether ultrathin-strut stents are particularly beneficial for lesions requiring implantation of more than 1 stent is unknown. METHODS: In a post-hoc lesion-level analysis of 2 randomized trials comparing ultrathin-strut biodegradable polymer Sirolimus-eluting stents (BP-SES) vs thin-strut durable polymer Everolimus-eluting stents (DP-EES), lesions were stratified into multistent lesions (MSL) vs single-stent lesions (SSL). The primary endpoint was target lesion failure (TLF), a composite of lesion-related unclear/cardiac death, myocardial infarction (MI), or revascularization, at 24 months. RESULTS: Among 5328 lesions in 3397 patients, 1492 (28%) were MSL (722 with BP-SES, 770 with DP-EES). At 2 years, TLF occurred in 63 lesions (8.9%) treated with BP-SES and 60 lesions (7.9%) treated with DP-EES in the MSL-group (subdistibution hazard ratio [SHR], 1.13; 95% CI, 0.77-1.64; P = .53), and in 121 (6.4%) and 136 (7.4%) lesions treated with BP-SES and DP-EES respectively (SHR, 0.86; 95% CI, 0.62-1.18; P = .35) in the SSL-group (P for interaction = .241). While the rates of lesion-related MI or revascularization were significantly lower in SSL treated with BP-SES as compared to DP-EES (3.5% vs 5.2%; SHR, 0.67; 95% CI 0.46-0.97; P = .036), no significant difference was observed in MSL (7.1% vs 5.4%; SHR, 1.31; 95% CI 0.85-2.03; P = .216) with significant interaction between groups (P for interaction = .014). CONCLUSIONS: Rates of TLF are similar between ultrathin-strut BP-SES and thin-strut DP-EES in MSL and SSL. The use of ultrathin-strut BP-SES vs thin-strut DP-EES did not prove to be particularly beneficial for the treatment of multistent lesions. TRIAL REGISTRATION: Post-hoc analysis from the BIOSCIENCE (NCT01443104) and BIOSTEMI (NCT02579031) trials.
Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Absorbable Implants , Coronary Artery Disease/surgery , Everolimus/pharmacology , Myocardial Infarction/epidemiology , Polymers , Prosthesis Design , Randomized Controlled Trials as Topic , Sirolimus , Treatment OutcomeABSTRACT
BACKGROUND: In aortic stenosis (AS), estimated glomerular filtration rate (eGFR) is an important prognostic marker but its haemodynamic determinants are unknown. We investigated the correlation between eGFR and invasive haemodynamics and long-term mortality in AS patients undergoing aortic valve replacement (AVR). METHODS: We studied 503 patients [median (interquartile range) age 76 (69-81) years] with AS [indexed aortic valve area .42 (.33-.49) cm2 /m2 ] undergoing cardiac catheterization prior to surgical (72%) or transcatheter (28%) AVR. Serum creatinine was measured on the day before cardiac catheterization for eGFR calculation (CKD-EPI formula). RESULTS: The median eGFR was 67 (53-82) mL/min/1.73 m2 . There were statistically significant correlations between eGFR and mean right atrial pressure (r = -.13; p = .004), mean pulmonary artery pressure (mPAP; r = -.25; p < .001), mean pulmonary artery wedge pressure (r = -.19; p < .001), pulmonary vascular resistance (r = -.21; p < .001), stroke volume index (r = .16; p < .001), extent of coronary artery disease, and mean transvalvular gradient but not indexed aortic valve area. In multivariate linear regression, higher age, lower haemoglobin, lower mean transvalvular gradient (i.e. lower flow), lower diastolic blood pressure, and higher mPAP were independent predictors of lower eGFR. After a median post-AVR follow-up of 1348 (948-1885) days mortality was more than two-fold higher in patients in the first eGFR quartile compared to those in the other three quartiles [hazard ratio 2.18 (95% confidence interval 1.21-3.94); p = .01]. CONCLUSION: In patients with AS, low eGFR is a marker of an unfavourable haemodynamic constellation as well as important co-morbidities. This may in part explain the association between low eGFR and increased post-AVR mortality.
Subject(s)
Aortic Valve Stenosis , Humans , Aged , Glomerular Filtration Rate , Follow-Up Studies , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Hemodynamics , Severity of Illness Index , Treatment OutcomeABSTRACT
BACKGROUND: Ultrathin-strut biodegradable polymer sirolimus-eluting stents (BP-SES) are superior to thin-strut durable polymer everolimus-eluting stents (DP-EES) with respect to target lesion failure (TLF) at 2 years among patients with ST-segment elevation myocardial infarction (STEMI). We sought to determine the impact of primary percutaneous coronary intervention (pPCI) complexity on long-term clinical outcomes with BP-SES versus DP-EES in STEMI patients. METHODS: We performed a post hoc subgroup analysis from the BIOSTEMI (NCT02579031) randomized trial, which included individual data from 407 STEMI patients enrolled in the BIOSCIENCE trial (NCT01443104). STEMI patients were randomly assigned to treatment with ultrathin-strut BP-SES or thin-strut DP-EES, and further categorized into those undergoing complex versus noncomplex pPCI. Complex pPCI was defined by the presence of ≥1 of the following criteria: 3 vessel treatment, ≥3 stents implanted, ≥3 lesions treated, bifurcation lesion with ≥2 stents implanted, total stent length ≥60 mm, and/or chronic total occlusion treatment. The primary endpoint was TLF, a composite of cardiac death, target-vessel myocardial reinfarction, or clinically indicated target lesion revascularization, within 2 years. RESULTS: Among a total of 1707 STEMI patients, 421 (24.7%) underwent complex pPCI. Baseline characteristics were similar between groups. At 2 years, TLF occurred in 14 patients (7.1%) treated with BP-SES and 25 patients (11.6%) treated with DP-EES (hazard ratio [HR]: 0.62; 95% confidence interval [CI]: 0.32-1.19; p = 0.15) in the complex pPCI group, and in 28 patients (4.4%) treated with BP-SES and 49 patients (8.2%) treated with DP-EES (HR: 0.54; 95% CI: 0.34-0.86; p = 0.008; p for interaction = 0.74) in the noncomplex pPCI group. Individual TLF components and stent thrombosis rates did not significantly differ between groups. CONCLUSION: In a post hoc subgroup analysis from the BIOSTEMI randomized trial, ultrathin-strut BP-SES were superior to thin-strut DP-EES with respect to TLF at 2 years among STEMI patients undergoing both complex and noncomplex pPCI.
Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , Absorbable Implants , Drug-Eluting Stents , Everolimus/adverse effects , Percutaneous Coronary Intervention/adverse effects , Polymers , Prosthesis Design , Sirolimus/adverse effects , ST Elevation Myocardial Infarction/etiology , Treatment Outcome , StentsABSTRACT
BACKGROUND: Gender-specific data addressing percutaneous coronary intervention (PCI) of chronic total occlusion (CTO) in female patients are scarce and based on small sample size studies. AIMS: We aimed to analyze gender-differences regarding in-hospital clinical outcomes after CTO-PCI. METHODS: Data from 35,449 patients enrolled in the prospective European Registry of CTOs were analyzed. The primary outcome was the comparison of procedural success rate in the two cohorts (women vs. men), defined as a final residual stenosis less than 20%, with Thrombolysis In Myocardial Infarction grade flow = 3. In-hospital major adverse cardiac and cerebrovascular events (MACCEs) and procedural complications were deemed secondary outcomes. RESULTS: Women represented 15.2% of the entire study population. They were older and more likely to have hypertension, diabetes, and renal failure, with an overall lower J-CTO score. Women showed a higher procedural success rate (adjusted OR [aOR] = 1.115, confidence interval [CI]: 1.011-1.230, p = 0.030). Apart from previous myocardial infarction and surgical revascularization, no other significant gender differences were found among predictors of procedural success. Antegrade approach with true-to-true lumen techniques was more commonly used than retrograde approach in females. No gender differences were found regarding in-hospital MACCEs (0.9% vs. 0.9%, p = 0.766), although a higher rate of procedural complications was observed in women, such as coronary perforation (3.7% vs. 2.9%, p < 0.001) and vascular complications (1.0% vs. 0.6%, p < 0.001). CONCLUSIONS: Women are understudied in contemporary CTO-PCI practice. Female sex is associated with higher procedural success after CTO-PCI, yet no sex differences were found in terms of in-hospital MACCEs. Female sex was associated with a higher rate of procedural complications.
Subject(s)
Coronary Occlusion , Myocardial Infarction , Percutaneous Coronary Intervention , Male , Humans , Female , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Coronary Occlusion/complications , Prospective Studies , Risk Factors , Treatment Outcome , Myocardial Infarction/etiology , Registries , Chronic Disease , Coronary Angiography/adverse effectsABSTRACT
BACKGROUND: A decade ago, the iopromide-paclitaxel coated balloon (iPCB) was added to the cardiologist's toolbox to initially treat in-stent restenosis followed by the treatment of de novo coronary lesions. In the meantime, DES technologies have been substantially improved to address in-stent restenosis and thrombosis, and shortened anti-platelet therapy. Recently, sirolimus-coated balloon catheters (SCB) have emerged to provide an alternative drug to combat restenosis. METHODS: The objective of this study is to determine the safety and efficacy of a novel crystalline sirolimus-coated balloon (cSCB) technology in an unselective, international, large-scale patient population. Percutaneous coronary interventions of native stenosis, in-stent stenosis, and chronic total occlusions with the SCB in patients with stable coronary artery disease or acute coronary syndrome were included. The primary outcome variable is the target lesion failure (TLF) rate at 12 months, defined as the composite rate of target vessel myocardial infarction (TV-MI), cardiac death or ischemia-driven target lesion revascularization (TLR). The secondary outcome variables include TLF at 24 months, ischemia driven TLR at 12 and 24 months and all-cause death, cardiac death at 12 and 24 months. DISCUSSION: Since there is a wealth of patient-based all-comers data for iPCB available for this study, a propensity-score matched analysis is planned to compare cSCB and iPCB for the treatment of de novo and different types of ISR. In addition, pre-specified analyses in challenging lesion subsets such as chronic total occlusions will provide evidence whether the two balloon coating technologies differ in their clinical benefit for the patient. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04470934.
Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Coronary Restenosis , Drug-Eluting Stents , Humans , Angioplasty/adverse effects , Cardiovascular Agents/adverse effects , Constriction, Pathologic/complications , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/complications , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Drug-Eluting Stents/adverse effects , Paclitaxel/adverse effects , Sirolimus/adverse effects , Treatment Outcome , Clinical Trials as TopicABSTRACT
BACKGROUND: In the treatment of de-novo coronary small vessel disease, drug-coated balloons (DCBs) are non-inferior to drug-eluting stents (DESs) regarding clinical outcome up to 12 months, but data beyond 1 year is sparse. We aimed to test the long-term efficacy and safety of DCBs regarding clinical endpoints in an all-comer population undergoing percutaneous coronary intervention. METHODS: In this prespecified long-term follow-up of a multicentre, randomised, open-label, non-inferiority trial, patients from 14 clinical sites in Germany, Switzerland, and Austria with de-novo lesions in coronary vessels <3 mm and an indication for percutaneous coronary intervention were randomly assigned 1:1 to DCB or second-generation DES and followed over 3 years for major adverse cardiac events (ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation [TVR]), all-cause death, probable or definite stent thrombosis, and major bleeding (Bleeding Academic Research Consortium bleeding type 3-5). Analyses were performed on the full analysis set according to the modified intention-to-treat principle. Dual antiplatelet therapy was recommended for 1 month after DCB and 6 months after DES with stable symptoms, but 12 months with acute coronary syndromes. The study is registered with ClinicalTrials.gov, NCT01574534 and is ongoing. FINDINGS: Between April 10, 2012, and Feb 1, 2017, of 883 patients assessed, 758 (86%) patients were randomly assigned to the DCB group (n=382) or the DES group (n=376). The Kaplan-Meier estimate of the rate of major adverse cardiac events was 15% in both the DCB and DES groups (hazard ratio [HR] 0·99, 95% CI 0·68-1·45; p=0·95). The two groups were also very similar concerning the single components of adverse cardiac events: cardiac death (Kaplan-Meier estimate 5% vs 4%, HR 1·29, 95% CI 0·63-2·66; p=0·49), non-fatal myocardial infarction (both Kaplan-Meier estimate 6%, HR 0·82, 95% CI 0·45-1·51; p=0·52), and TVR (both Kaplan-Meier estimate 9%, HR 0·95, 95% CI 0·58-1·56; p=0·83). Rates of all-cause death were very similar in DCB versus DES patients (both Kaplan-Meier estimate 8%, HR 1·05, 95% CI 0·62-1·77; p=0·87). Rates of probable or definite stent thrombosis (Kaplan-Meier estimate 1% vs 2%; HR 0·33, 95% CI 0·07-1·64; p=0·18) and major bleeding (Kaplan-Meier estimate 2% vs 4%, HR 0·43, 95% CI 0·17-1·13; p=0·088) were numerically lower in DCB versus DES, however without reaching significance. INTERPRETATION: There is maintained efficacy and safety of DCB versus DES in the treatment of de-novo coronary small vessel disease up to 3 years. FUNDING: Swiss National Science Foundation, Basel Cardiovascular Research Foundation, and B Braun Medical.
Subject(s)
Angioplasty, Balloon, Coronary/standards , Coronary Artery Disease/therapy , Drug-Eluting Stents/standards , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Diseases/etiology , Cardiovascular Diseases/mortality , Coronary Artery Disease/mortality , Drug-Eluting Stents/adverse effects , Female , Follow-Up Studies , Humans , Kaplan-Meier Estimate , Male , Treatment OutcomeABSTRACT
BACKGROUND: Newer-generation drug-eluting stents that combine ultrathin strut metallic platforms with biodegradable polymers might facilitate vascular healing and improve clinical outcomes in patients with acute myocardial infarction undergoing primary percutaneous coronary intervention (PCI) compared with contemporary thin strut second-generation drug-eluting stents. We did a randomised clinical trial to investigate the safety and efficacy of ultrathin strut biodegradable polymer sirolimus-eluting stents versus thin strut durable polymer everolimus-eluting stents in patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary PCI. METHODS: The BIOSTEMI trial was an investigator-initiated, multicentre, prospective, single-blind, randomised superiority trial at ten hospitals in Switzerland. Patients aged 18 years or older with acute STEMI who were referred for primary PCI were eligible to participate. Patients were randomly allocated (1:1) to either biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Central randomisation was done based on a computer-generated allocation sequence with variable block sizes of 2, 4, and 6, which was stratified by centre, diabetes status, and presence or absence of multivessel coronary artery disease, and concealed using a secure web-based system. Patients and treating physicians were aware of group allocations, whereas outcome assessors were masked to the allocated stent. The experimental stent (Orsiro; Biotronik; Bülach, Switzerland) consisted of an ultrathin strut cobalt-chromium metallic stent platform releasing sirolimus from a biodegradable polymer. The control stent (Xience Xpedition/Alpine; Abbott Vascular, Abbott Park, IL, USA) consisted of a thin strut cobalt-chromium stent platform that releases everolimus from a durable polymer. The primary endpoint was target lesion failure, a composite of cardiac death, target vessel myocardial reinfarction (Q-wave and non-Q-wave), and clinically-indicated target lesion revascularisation, within 12 months of the index procedure. All analyses were done with the individual participant as the unit of analysis and according to the intention-to-treat principle. The trial was registered with ClinicalTrials.gov, number NCT02579031. FINDINGS: Between April 26, 2016, and March 9, 2018, we randomly assigned 1300 patients (1623 lesions) with acute myocardial infarction to treatment with biodegradable polymer sirolimus-eluting stents (649 patients and 816 lesions) or durable polymer everolimus-eluting stents (651 patients and 806 lesions). At 12 months, follow-up data were available for 614 (95%) patients treated with biodegradable polymer sirolimus-eluting stents and 626 (96%) patients treated with durable polymer everolimus-eluting stents. The primary composite endpoint of target lesion failure occurred in 25 (4%) of 649 patients treated with biodegradable polymer sirolimus-eluting stents and 36 (6%) of 651 patients treated with durable polymer everolimus-eluting stents (difference -1·6 percentage points; rate ratio 0·59, 95% Bayesian credibility interval 0·37-0·94; posterior probability of superiority 0·986). Cardiac death, target vessel myocardial reinfarction, clinically-indicated target lesion revascularisation, and definite stent thrombosis were similar between the two treatment groups in the 12 months of follow-up. INTERPRETATION: In patients with acute STEMI undergoing primary PCI, biodegradable polymer sirolimus-eluting stents were superior to durable polymer everolimus-eluting stents with respect to target lesion failure at 1 year. This difference was driven by reduced ischaemia-driven target lesion revascularisation in patients treated with biodegradable polymer sirolimus-eluting stents compared with durable polymer everolimus-eluting stents. FUNDING: Biotronik.
Subject(s)
Absorbable Implants , Blood Vessel Prosthesis , Drug-Eluting Stents , Everolimus/therapeutic use , Immunosuppressive Agents/therapeutic use , Percutaneous Coronary Intervention/methods , ST Elevation Myocardial Infarction/surgery , Sirolimus/therapeutic use , Female , Humans , Male , Middle Aged , Polymers , Single-Blind MethodABSTRACT
OBJECTIVES: To report clinical, angiographic characteristics, outcomes, and predictors of unsuccessful procedures in patients who underwent chronic total occlusion (CTO) percutaneous coronary interventions (PCI) in Latin America. BACKGROUND: CTO PCI has been increasingly performed worldwide, but there is a lack of information in this region. METHODS: An international multicenter registry was developed to collect data on CTO PCI performed in centers in Latin America. Patient, angiographic, procedural and outcome data were evaluated. Predictors of unsuccessful procedures were assessed by multivariable analysis. RESULTS: We have included data related to 1,040 CTO PCIs performed in seven countries in Latin America (Argentina, Brazil, Chile, Colombia, Ecuador, Mexico, and Puerto Rico). The mean age was 64 ± 10 years, and CTO PCI was performed mainly for angina control (81%) or treatment of a large ischemic area (30%). Overall technical success rate was 82.5%, and it was achieved with antegrade wire escalation in 81%, antegrade dissection/re-entry in 8% and with retrograde techniques in 11% of the successful procedures. Multivariable analysis identified moderate/severe calcification, a blunt proximal cap and a previous attempt as independent predictors of unsuccessful procedures. In-hospital major adverse cardiovascular events (MACE) occurred in 3.1% of the cases, death in 1% and cardiac tamponade in 0.9% CONCLUSIONS: CTO PCI in Latin America has been performed mainly for ischemia relief. Procedures were associated with a success rate above 80% and low incidence of MACE. Predictors of unsuccessful procedures were similar to those previously reported in the literature.
Subject(s)
Coronary Occlusion/therapy , Percutaneous Coronary Intervention , Aged , Chronic Disease , Coronary Angiography , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/mortality , Female , Hospital Mortality , Humans , Latin America , Male , Middle Aged , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Registries , Risk Assessment , Risk Factors , Stroke/mortality , Time Factors , Treatment OutcomeABSTRACT
BACKGROUND: Drug-eluting stents combining an ultrathin cobalt-chromium stent platform with a biodegradable polymer eluting sirolimus have been shown to be non-inferior or superior to thin-strut, durable-polymer, everolimus-eluting stents in terms of 1 year safety and efficacy outcomes. METHODS: In the randomised, single-blind, multicentre, non-inferiority BIOSCIENCE trial, we compared biodegradable-polymer sirolimus-eluting stents with durable-polymer everolimus-eluting stents in patients with chronic stable coronary artery disease or acute coronary syndromes. Here, we assess the final 5-year clinical outcomes of BIOSCIENCE with regards to the primary clinical outcome of target lesion failure, which was a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation. The primary analysis was done by intention to treat. The BIOSCIENCE trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: 2008 (95%) of 2119 patients recruited between March 1, 2012, and May 31, 2013, completed 5 years of follow-up. Target lesion failure occurred in 198 patients (cumulative incidence 20·2%) treated with biodegradable-polymer sirolimus-eluting stents and in 189 patients (18·8%) treated with durable-polymer everolimus-eluting stents (rate ratio [RR] 1·07, 95% CI 0·88-1·31; p=0·487). All-cause mortality was significantly higher in patients treated with biodegradable-polymer sirolimus-eluting stents than in those treated with durable-polymer everolimus-eluting stents (14·1% vs 10·3%; RR 1·36, 95% CI 1·06-1·75; p=0·017), driven by a difference in non-cardiovascular deaths. We observed no difference between groups in cumulative incidence of definite stent thrombosis at 5 years (1·6% in both groups; 1·02, 0·51-2·05; p=0·950). INTERPRETATION: 5-year risk of target lesion failure among all-comer patients undergoing percutaneous coronary intervention is similar after implantation of ultrathin-strut, biodegradable-polymer, sirolimus-eluting stents or thin-strut, durable-polymer, everolimus-eluting stents. Higher incidences of all-cause and non-cardiovascular mortality in patients treated with biodegradable-polymer stents eluting sirolimus than in those treated with durable-polymer stents eluting everolimus warrant careful observation in ongoing clinical trials. FUNDING: Clinical Trials Unit of the University of Bern and Biotronik.
Subject(s)
Acute Coronary Syndrome/surgery , Coronary Artery Disease/surgery , Drug-Eluting Stents , Everolimus/administration & dosage , Immunosuppressive Agents/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Sirolimus/administration & dosage , Absorbable Implants , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/mortality , Adult , Aged , Aged, 80 and over , Cause of Death , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Drug-Eluting Stents/adverse effects , Female , Follow-Up Studies , Humans , Intention to Treat Analysis , Male , Middle Aged , Myocardial Infarction/etiology , Myocardial Infarction/mortality , Polymers , Prosthesis Design , Prosthesis Failure/etiology , Single-Blind Method , Thrombosis/etiology , Treatment OutcomeABSTRACT
BACKGROUND: Drug-coated balloons (DCB) are a novel therapeutic strategy for small native coronary artery disease. However, their safety and efficacy is poorly defined in comparison with drug-eluting stents (DES). METHODS: BASKET-SMALL 2 was a multicentre, open-label, randomised non-inferiority trial. 758 patients with de-novo lesions (<3 mm in diameter) in coronary vessels and an indication for percutaneous coronary intervention were randomly allocated (1:1) to receive angioplasty with DCB versus implantation of a second-generation DES after successful predilatation via an interactive internet-based response system. Dual antiplatelet therapy was given according to current guidelines. The primary objective was to show non-inferiority of DCB versus DES regarding major adverse cardiac events (MACE; ie, cardiac death, non-fatal myocardial infarction, and target-vessel revascularisation) after 12 months. The non-inferiority margin was an absolute difference of 4% in MACE. This trial is registered with ClinicalTrials.gov, number NCT01574534. FINDINGS: Between April 10, 2012, and February 1, 2017, 382 patients were randomly assigned to the DCB group and 376 to DES group. Non-inferiority of DCB versus DES was shown because the 95% CI of the absolute difference in MACE in the per-protocol population was below the predefined margin (-3·83 to 3·93%, p=0·0217). After 12 months, the proportions of MACE were similar in both groups of the full-analysis population (MACE was 7·5% for the DCB group vs 7·3% for the DES group; hazard ratio [HR] 0·97 [95% CI 0·58-1·64], p=0·9180). There were five (1·3%) cardiac-related deaths in the DES group and 12 (3·1%) in the DCB group (full analysis population). Probable or definite stent thrombosis (three [0·8%] in the DCB group vs four [1·1%] in the DES group; HR 0·73 [0·16-3·26]) and major bleeding (four [1·1%] in the DCB group vs nine [2·4%] in the DES group; HR 0·45 [0·14-1·46]) were the most common adverse events. INTERPRETATION: In small native coronary artery disease, DCB was non-inferior to DES regarding MACE up to 12 months, with similar event rates for both treatment groups. FUNDING: Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Basel Cardiovascular Research Foundation, and B Braun Medical AG.
Subject(s)
Angioplasty, Balloon, Coronary/methods , Coated Materials, Biocompatible/therapeutic use , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Aged , Female , Humans , Male , Middle Aged , Proportional Hazards Models , Prospective StudiesABSTRACT
Chronic thromboembolic pulmonary hypertension (CTEPH) is a severe complication of pulmonary embolism. Its incidence following pulmonary embolism is debated. Active screening for CTEPH in patients with acute pulmonary embolism is yet to be recommended.This prospective, multicentre, observational study (Multicentre Observational Screening Survey for the Detection of Chronic Thromboembolic Pulmonary Hypertension (CTEPH) Following Pulmonary Embolism (INPUT on PE); ISRCTN61417303) included patients with acute pulmonary embolism from 11 centres in Switzerland from March 2009 to November 2016. Screening for possible CTEPH was performed at 6, 12 and 24â months using a stepwise algorithm that included a dyspnoea phone-based survey, transthoracic echocardiography, right heart catheterisation and radiological confirmation of CTEPH.Out of 1699 patients with pulmonary embolism, 508 patients were assessed for CTEPH screening over 2â years. CTEPH incidence following pulmonary embolism was 3.7 per 1000â patient-years, with a 2-year cumulative incidence of 0.79%. The Swiss pulmonary hypertension registry consulted in December 2016 did not report additional CTEPH cases in these patients. The survey yielded 100% sensitivity and 81.6% specificity. The second step echocardiography in newly dyspnoeic patients showed a negative predictive value of 100%.CTEPH is a rare but treatable disease. A simple and sensitive way for CTEPH screening in patients with acute pulmonary embolism is recommended.
Subject(s)
Hypertension, Pulmonary/epidemiology , Pulmonary Embolism/complications , Thromboembolism/complications , Aged , Chronic Disease , Female , Humans , Incidence , Male , Mass Screening , Middle Aged , Prospective Studies , Registries , Risk Factors , Sensitivity and Specificity , Surveys and Questionnaires , Switzerland/epidemiologyABSTRACT
OBJECTIVE: We sought to assess the angiographic and long-term clinical outcomes in a predominantly medically treated population with spontaneous coronary artery dissection (SCAD). BACKGROUND: There are little data on the angiographic and long-term outcome in patients with SCAD. METHODS: We studied 64 patients with SCAD (mean age 53 years, 94% females, three peripartum) with acute coronary syndrome who were treated using coronary bypass grafting (n = 1), percutaneous coronary intervention (n = 7), or medical therapy (n = 56). A repeat angiogram was performed in 40/64 (63%) patients. The median clinical follow-up was 4.5 years. RESULTS: Five (8%) patients had a major cardiac event. One patient with peripartum left main SCAD and cardiogenic shock died during PCI. One patient with conservatively treated SCAD of the posterior descending artery suffered out-of-hospital cardiac arrest 16 days after the initial angiogram but survived. Three patients experienced a second SCAD in another vessel 3.7, 4.7, and 7.9 years after the index event while the initial dissection had healed. Thirty medically treated patients underwent a scheduled repeat angiogram showing healing of the dissection in all but one patient. After a median follow-up of 4.5 (1.8-8.4) years, all 63 patients surviving the index event were alive and free of symptoms suggestive of myocardial ischemia. CONCLUSIONS: In general, the long-term outcome of patients with SCAD is excellent, and medical therapy can be safely applied in the majority of patients. However, SCAD can be a life-threatening and sometimes catastrophic event, and some patients experience early or late complications including SCAD of another vessel. © 2015 Wiley Periodicals, Inc.
Subject(s)
Acute Coronary Syndrome/diagnostic imaging , Acute Coronary Syndrome/therapy , Cardiovascular Agents/therapeutic use , Coronary Angiography , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/therapy , Vascular Diseases/congenital , Acute Coronary Syndrome/etiology , Acute Coronary Syndrome/mortality , Adult , Cardiovascular Agents/adverse effects , Coronary Artery Bypass , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/mortality , Disease-Free Survival , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Out-of-Hospital Cardiac Arrest/etiology , Percutaneous Coronary Intervention , Predictive Value of Tests , Pregnancy , Recurrence , Registries , Risk Assessment , Risk Factors , Shock, Cardiogenic/etiology , Switzerland , Time Factors , Treatment Outcome , Vascular Diseases/complications , Vascular Diseases/diagnostic imaging , Vascular Diseases/mortality , Vascular Diseases/therapyABSTRACT
BACKGROUND: Biodegradable-polymer drug-eluting stents (BP-DES) were developed to be as effective as second-generation durable-polymer drug-eluting stents (DP-DES) and as safe >1 year as bare-metal stents (BMS). Thus, very late stent thrombosis (VLST) attributable to durable polymers should no longer appear. METHODS AND RESULTS: To address these early and late aspects, 2291 patients presenting with acute or stable coronary disease needing stents ≥3.0 mm in diameter between April 2010 and May 2012 were randomly assigned to biolimus-A9-eluting BP-DES, second-generation everolimus-eluting DP-DES, or thin-strut silicon-carbide-coated BMS in 8 European centers. All patients were treated with aspirin and risk-adjusted doses of prasugrel. The primary end point was combined cardiac death, myocardial infarction, and clinically indicated target-vessel revascularization within 2 years. The combined secondary safety end point was a composite of VLST, myocardial infarction, and cardiac death. The cumulative incidence of the primary end point was 7.6% with BP-DES, 6.8% with DP-DES, and 12.7% with BMS. By intention-to-treat BP-DES were noninferior (predefined margin, 3.80%) compared with DP-DES (absolute risk difference, 0.78%; -1.93% to 3.50%; P for noninferiority 0.042; per protocol P=0.09) and superior to BMS (absolute risk difference, -5.16; -8.32 to -2.01; P=0.0011). The 3 stent groups did not differ in the combined safety end point, with no decrease in events >1 year, particularly VLST with BP-DES. CONCLUSIONS: In large vessel stenting, BP-DES appeared barely noninferior compared with DP-DES and more effective than thin-strut BMS, but without evidence for better safety nor lower VLST rates >1 year. Findings challenge the concept that durable polymers are key in VLST formation. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01166685.
Subject(s)
Absorbable Implants , Anti-Inflammatory Agents/therapeutic use , Coronary Artery Disease/therapy , Drug-Eluting Stents , Polymers , Sirolimus/analogs & derivatives , Absorbable Implants/adverse effects , Aged , Anti-Inflammatory Agents/adverse effects , Aspirin/therapeutic use , Drug-Eluting Stents/adverse effects , Everolimus , Female , Humans , Kaplan-Meier Estimate , Longitudinal Studies , Male , Metals , Middle Aged , Piperazines/therapeutic use , Platelet Aggregation Inhibitors/therapeutic use , Polymers/adverse effects , Prasugrel Hydrochloride , Purinergic P2Y Receptor Antagonists/therapeutic use , Single-Blind Method , Sirolimus/adverse effects , Sirolimus/therapeutic use , Stents , Switzerland , Thiophenes/therapeutic use , Treatment OutcomeABSTRACT
BACKGROUND: Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS: We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS: Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION: In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING: Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.
Subject(s)
Anti-Bacterial Agents/therapeutic use , Drug-Eluting Stents , Percutaneous Coronary Intervention/methods , Sirolimus/analogs & derivatives , Sirolimus/therapeutic use , Absorbable Implants , Aged , Anti-Bacterial Agents/administration & dosage , Everolimus , Female , Humans , Male , Myocardial Infarction/surgery , Percutaneous Coronary Intervention/instrumentation , Polymers , Single-Blind Method , Sirolimus/administration & dosage , Treatment OutcomeABSTRACT
BACKGROUND: Registries are important for real-life epidemiology on different pulmonary hypertension (PH) groups. OBJECTIVE: To provide long-term data of the Swiss PH registry of 1998-2012. METHODS: PH patients have been classified into 5 groups and registered upon written informed consent at 5 university and 8 associated hospitals since 1998. New York Heart Association (NYHA) class, 6-min walk distance, hemodynamics and therapy were registered at baseline. Patients were regularly followed, and therapy and events (death, transplantation, endarterectomy or loss to follow-up) registered. The data were stratified according to the time of diagnosis into prevalent before 2000 and incident during 2000-2004, 2005-2008 and 2009-2012. RESULTS: From 996 (53% female) PH patients, 549 had pulmonary arterial hypertension (PAH), 36 PH due to left heart disease, 127 due to lung disease, 249 to chronic thromboembolic PH (CTEPH) and 35 to miscellaneous PH. Age and BMI significantly increased over time, whereas hemodynamic severity decreased. Overall, event-free survival was 84, 72, 64 and 58% for the years 1-4 and similar for time periods since 2000, but better during the more recent periods for PAH and CTEPH. Of all PAH cases, 89% had target medical therapy and 43% combination therapy. Of CTEPH patients, 14 and 2% underwent pulmonary endarterectomy or transplantation, respectively; 87% were treated with PAH target therapy. CONCLUSION: Since 2000, the incident Swiss PH patients registered were older, hemodynamically better and mostly treated with PAH target therapies. Survival has been better for PAH and CTEPH diagnosed since 2008 compared with earlier diagnosis or other classifications.
Subject(s)
Hypertension, Pulmonary/epidemiology , Registries , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Switzerland/epidemiology , Young AdultABSTRACT
BACKGROUND: Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the durable polymer-based Xience Prime/Xpedition everolimus-eluting stent (EES) (Xience Prime/Xpedition stent, Abbott Vascular, IL) in an all-comers patient population. DESIGN: The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer sirolimus-eluting stents (SES) or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least 1 lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary end point target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for noninferiority, inclusion of 2,060 patients would provide more than 80% power to detect noninferiority of the biodegradable polymer SES compared with the durable polymer EES at a 1-sided type I error of 0.05. Clinical follow-up will be continued through 5 years. CONCLUSION: The BIOSCIENCE trial will determine whether the biodegradable polymer SES is noninferior to the durable polymer EES with respect to TLF.
Subject(s)
Absorbable Implants , Acute Coronary Syndrome/therapy , Coronary Artery Disease/therapy , Drug-Eluting Stents , Sirolimus/analogs & derivatives , Sirolimus/administration & dosage , Everolimus , Humans , Percutaneous Coronary Intervention , Research DesignABSTRACT
BACKGROUND: There is an association between hyperthyroidism and pulmonary hypertension. However, the prevalence of pulmonary hypertension in hyperthyroidism and the underlying mechanisms are incompletely defined. METHODS: Consecutive patients with severe hyperthyroidism, mostly due to Graves disease, were included in this single-center study. Echocardiographic assessment of pulmonary hemodynamics was performed at the time of hyperthyroidism diagnosis (baseline) and after normalization of thyroid hormones (follow-up; median 11 months). In a subset of patients, right heart catheterization and noninvasive assessment of central hemodynamics was performed. RESULTS: Among all 99 patients, 31% had pulmonary hypertension at baseline. The estimated systolic pulmonary artery pressure correlated significantly with the estimated left ventricular filling pressure (E/e'). The invasively measured systolic pulmonary artery pressure correlated well with the estimated systolic pulmonary artery pressure. Cardiac output, E/e', left and right ventricular dimensions were significantly reduced from baseline to follow-up, whereas the estimated pulmonary vascular resistance did not differ. Diastolic blood pressure was significantly higher at follow-up, with no change in systolic blood pressure. The central systolic blood pressure, however, exhibited a trend for a reduction at follow-up, while the pulse wave velocity was significantly lower at follow-up. CONCLUSIONS: Approximately one-third of patients with hyperthyroidism have evidence of pulmonary hypertension. Our data suggest that an increased cardiac output and left ventricular filling pressure are the main mechanisms underlying the elevated systolic pulmonary artery pressure in hyperthyroidism, whereas there is no evidence of significant pulmonary vascular disease.
Subject(s)
Hypertension, Pulmonary , Hyperthyroidism , Humans , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/diagnosis , Pulse Wave Analysis , Hemodynamics/physiology , Vascular Resistance/physiology , Cardiac Catheterization/methods , Hyperthyroidism/complicationsABSTRACT
AIM: Pleural effusion (PE) is a common chest radiography (CXR) finding in patients with advanced cardiac disease. The pathophysiology and clinical value of PE in this setting are incompletely defined. We aimed to assess the haemodynamic correlates and prognostic impact of PE in patients with severe aortic stenosis (AS). METHODS AND RESULTS: We studied 471 patients (mean age 74 ± 10 years) with severe AS (indexed aortic valve area 0.42 ± 0.12 cm2/m2, left ventricular ejection fraction 58 ± 12%) undergoing right heart catheterization and upright CXR prior to aortic valve replacement (AVR). Two radiologist independently evaluated all CXR for the presence of bilateral PE, unilateral, or no PE, blinded to any other data. There were 49 (10%) patients with bilateral PE, 32 (7%) patients with unilateral PE, and 390 (83%) patients with no PE. Patients with bilateral PE had the highest mean right atrial pressure, mean pulmonary artery wedge pressure (mPAWP), and pulmonary vascular resistance, and had the lowest stroke volume index while those with unilateral PE had intermediate values. In the multivariate analysis, mPAWP was an independent predictor of any PE and bilateral PE. After a median (interquartile range) post-AVR follow-up of 1361 (957-1878) days mortality was highest in patients with bilateral PE (2.7 times higher than in patients without PE), whereas patients with unilateral PE had similar mortality as those without PE. CONCLUSIONS: In severe AS patients, the presence of PE, particularly bilateral PE, is a marker of a poor haemodynamic constellation. Bilateral PE is associated with a substantially increased post-AVR mortality.
Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Pleural Effusion , Humans , Middle Aged , Aged , Aged, 80 and over , Stroke Volume/physiology , Aortic Valve Stenosis/surgery , Ventricular Function, Left , Hemodynamics/physiology , Prognosis , Pleural Effusion/complications , Pleural Effusion/surgeryABSTRACT
AIMS: Blood pressure (BP) targets in patients with aortic stenosis (AS) are controversial. This study sought to describe the haemodynamic profile and the clinical outcome of severe AS patients with low versus high central meaarterial pressure (MAP). METHODS AND RESULTS: Patients with severe AS (n = 477) underwent right and left heart catheterization prior to aortic valve replacement (AVR). The population was divided into MAP quartiles. The mean systolic BP, diastolic BP, and MAP in the entire population were 149 ± 25, 68 ± 11, and 98 ± 14 mmHg. Patients in the lowest MAP quartile had the lowest left ventricular ejection fraction (LVEF), systemic vascular resistance, and valvulo-arterial impedance, whereas there were no significant differences in mean right atrial pressure, mean pulmonary artery wedge pressure, pulmonary vascular resistance, and stroke volume index across MAP quartiles. However, left ventricular stroke work index (LVSWI) was lowest in patients in the lowest and highest in those in the highest MAP quartile. After a median (interquartile range) post-AVR follow-up of 3.7 (2.6-5.2) years, mortality was highest in patients in the lowest MAP quartile [hazard ratio 3.08 (95% confidence interval 1.21-7.83); P = 0.02 for lowest versus highest quartile]. In the multivariate analysis, lower MAP [hazard ratio 0.78 (95% confidence interval 0.62-0.99) per 10 mmHg increase; P = 0.04], higher mean right atrial pressure and lower LVEF were independent predictors of death. CONCLUSIONS: In severe AS patients, lower MAP reflects lower systemic vascular resistance and valvulo-arterial impedance, which may help to preserve stroke volume and filling pressures despite reduced left ventricular performance, and lower MAP is a predictor of higher long-term post-AVR mortality.