Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
J Chem Phys ; 155(9): 094701, 2021 Sep 07.
Article in English | MEDLINE | ID: mdl-34496587

ABSTRACT

The passivation of polycrystalline nickel surfaces against hydrogen uptake by oxygen is investigated experimentally with low energy ion scattering (LEIS), direct recoil spectroscopy (DRS), and thermal desorption spectroscopy (TDS). These techniques are highly sensitive to surface hydrogen, allowing the change in hydrogen adsorption in response to varying amounts of oxygen exposure to be measured. The chemical composition of a nickel surface during a mixed oxygen and hydrogen exposure was characterized with LEIS and DRS, while the uptake and activation energies of hydrogen on a nickel surface with preadsorbed oxygen were quantified with TDS. By and large, these measurements of how the oxygen and hydrogen surface coverage varied in response to oxygen exposure were found to be consistent with predictions of a simple site-blocking model. This finding suggests that, despite the complexities that arise due to polycrystallinity, the oxygen-induced passivation of a polycrystalline nickel surface against hydrogen uptake can be approximated by a simple site-blocking model.

2.
ACS Appl Mater Interfaces ; 15(35): 41598-41605, 2023 Sep 06.
Article in English | MEDLINE | ID: mdl-37607333

ABSTRACT

Rugged Pd-metal-insulator-semiconductor (Pd-MIS) hydrogen sensors for detecting charge-exchange particles in fusion reactors have been constructed by utilizing a novel patterned adhesion layer. Poor adhesion at the interface between Pd and SiO2 is a common failure mode for Pd-MIS devices, severely limiting the Pd thickness and their usefulness as hydrogen sensors. The mechanical integrity of the Pd coatings is of particular importance in magnetic fusion energy research where the Pd-MIS diodes are used to measure hydrogen charge-exchange neutral fluence at the wall in tokamaks. In this application, particularly thick Pd contacts are desirable to prevent damage caused by high-energy particles; however, such thick Pd coatings are prone to mechanical failure due to blistering and wire bond detachment during construction or operation. A continuous Ti or Cr adhesion layer is not possible for this application since it would interfere with H uptake at the SiO2 interface, which is essential for the device to generate a response. In this work, we demonstrate that a patterned Cr interlayer substantially improves adhesion while still providing access for hydrogen to reach the SiO2-Pd interface.

3.
J Phys Condens Matter ; 33(1): 015001, 2021 Jan 06.
Article in English | MEDLINE | ID: mdl-33052893

ABSTRACT

Helium ion beam interactions with materials have important implications for magnetic confinement fusion, material modification, and helium ion microscopy. These interactions depend on the precise physics of how helium ions channel into the materials, which can vary greatly based on the local crystalline orientation. In this work, we performed a dedicated experiment to investigate helium ion channeling in a well-characterized tungsten single crystal. Time-of-flight impact-collision ion scattering spectroscopy was used to obtain multi-angle maps of the backscattering intensity for 3 keV He+ → W(111). We found that the backscattering intensity profile arising from helium ion channeling could be well described by a shadow cone analysis. This analysis revealed that subsurface W atoms as deep as the ninth monolayer contributed to the backscattering intensity profile. Binary collision approximation simulations were performed with MARLOWE to model the experimental maps with sufficient accuracy to allow for quantitative comparisons using reliability factors. These quantitative comparisons were applied to investigate how the W lattice structure and He-W interatomic potential affect the multi-angle maps.

4.
ACS Appl Mater Interfaces ; 11(5): 4930-4941, 2019 Feb 06.
Article in English | MEDLINE | ID: mdl-30630309

ABSTRACT

Solid-state metal hydrides are prime candidates to replace compressed hydrogen for fuel cell vehicles due to their high volumetric capacities. Sodium aluminum hydride has long been studied as an archetype for higher-capacity metal hydrides, with improved reversibility demonstrated through the addition of titanium catalysts; however, atomistic mechanisms for surface processes, including hydrogen desorption, are still uncertain. Here, operando and ex situ measurements from a suite of diagnostic tools probing multiple length scales are combined with ab initio simulations to provide a detailed and unbiased view of the evolution of the surface chemistry during hydrogen release. In contrast to some previously proposed mechanisms, the titanium dopant does not directly facilitate desorption at the surface. Instead, oxidized surface species, even on well-protected NaAlH4 samples, evolve during dehydrogenation to form surface hydroxides with differing levels of hydrogen saturation. Additionally, the presence of these oxidized species leads to considerably lower computed barriers for H2 formation compared to pristine hydride surfaces, suggesting that oxygen may actively participate in hydrogen release, rather than merely inhibiting diffusion as is commonly presumed. These results demonstrate how close experiment-theory feedback can elucidate mechanistic understanding of complex metal hydride chemistry and potentially impactful roles of unavoidable surface impurities.

5.
Rev Sci Instrum ; 81(8): 086104, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20815633

ABSTRACT

We describe a fixture that allows electrochemical devices to be studied under electrical bias in the type of vacuum systems commonly used in surface science. Three spring-loaded probes provide independent contacts for device operation and the characterization in vacuum or under in situ conditions with reactive gases. We document the robustness of the electrical contacts over large temperature changes and their reliability for conventional electrochemical measurements such as impedance spectroscopy. The optical access provided to the device enables the analysis by many techniques, as we demonstrate using x-ray photoelectron spectroscopy to measure local electrical potentials on a solid-oxide electrolyte device operating at high temperature in near-ambient pressure.

SELECTION OF CITATIONS
SEARCH DETAIL