Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Mol Cell Proteomics ; 14(7): 1959-76, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25953087

ABSTRACT

Mutations in PIK3CA, the gene encoding the p110α catalytic subunit of phosphoinositide 3-kinase (PI3K) have been shown to transform human mammary epithelial cells (MECs). These mutations are present in all breast cancer subtypes, including basal-like breast cancer (BLBC). Using liquid chromatography-tandem mass spectrometry (LC-MS/MS), we identified 72 protein expression changes in human basal-like MECs with knock-in E545K or H1047R PIK3CA mutations versus isogenic MECs with wild-type PIK3CA. Several of these were secreted proteins, cell surface receptors or ECM interacting molecules and were required for growth of PIK3CA mutant cells as well as adjacent cells with wild-type PIK3CA. The proteins identified by MS were enriched among human BLBC cell lines and pointed to a PI3K-dependent amphiregulin/EGFR/ERK signaling axis that is activated in BLBC. Proteins induced by PIK3CA mutations correlated with EGFR signaling and reduced relapse-free survival in BLBC. Treatment with EGFR inhibitors reduced growth of PIK3CA mutant BLBC cell lines and murine mammary tumors driven by a PIK3CA mutant transgene, all together suggesting that PIK3CA mutations promote tumor growth in part by inducing protein changes that activate EGFR.


Subject(s)
Breast Neoplasms/genetics , ErbB Receptors/metabolism , Extracellular Signal-Regulated MAP Kinases/metabolism , Mutation/genetics , Paracrine Communication , Phosphatidylinositol 3-Kinases/genetics , Signal Transduction , Amphiregulin/metabolism , Animals , Breast Neoplasms/drug therapy , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Cell Line, Tumor , Cell Proliferation/drug effects , Chromatography, Liquid , Class I Phosphatidylinositol 3-Kinases , Disease-Free Survival , Down-Regulation/drug effects , Epidermal Growth Factor/pharmacology , ErbB Receptors/antagonists & inhibitors , Extracellular Matrix/drug effects , Extracellular Matrix/metabolism , Female , Humans , Mice, Nude , Neoplasm Proteins/metabolism , Paracrine Communication/drug effects , Protein Binding/drug effects , Protein Kinase Inhibitors/pharmacology , Protein Kinase Inhibitors/therapeutic use , Proteomics , Signal Transduction/drug effects , Tandem Mass Spectrometry , Up-Regulation/drug effects
2.
Mol Cell Proteomics ; 12(9): 2623-39, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23689285

ABSTRACT

Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.


Subject(s)
Chromatography, Liquid/instrumentation , Chromatography, Liquid/methods , Mass Spectrometry/instrumentation , Mass Spectrometry/methods , Amino Acid Sequence , Animals , Cattle , Limit of Detection , Molecular Sequence Data , Peptides/chemistry , Peptides/metabolism , Reference Standards , Software , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL