Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 84
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38525529

ABSTRACT

The internal jugular vein (IJV) is occasionally used for blood access during catheter ablation. Additionally, accidental injury of the vertebral artery during an IJV puncture is a rare complication that can result in catastrophic events, such as death. However, vascular access complications cannot be completely prevented despite the introduction of ultrasound-guided punctures. Here, we present a case of a patient with symptomatic paroxysmal atrial fibrillation that required catheter ablation.

2.
J Cardiovasc Electrophysiol ; 34(3): 556-564, 2023 03.
Article in English | MEDLINE | ID: mdl-36718076

ABSTRACT

INTRODUCTION: The superior vena cava (SVC) is the most common source of non-pulmonary vein foci in atrial fibrillation (AF); therefore, predicting the existence of non-pulmonary vein foci before the catheter ablation procedure helps construct a proper ablation strategy in preparation for SVC isolation. This study aimed to clarify the structural characteristics of patients with SVC foci initiating AF. METHODS: We enrolled 331 consecutive patients with AF who underwent cardiac computed tomography imaging before radiofrequency catheter ablation treatment, and they were divided into SVC (+) and (-) groups based on the presence or absence of SVC foci initiating AF. RESULTS: The SVC (+) group (n = 27) exhibited SVC crescent signs-defined as a curve-shaped SVC with two narrow pointed ends-more frequently (37% vs. 9%, p < .001), and larger right atrial volume (95.6 ± 20.8 vs. 80.5 ± 26.1 mL, p = .004) than the SVC (-) group (n = 304). Multivariate logistic regression analysis revealed that the SVC crescent sign (odds ratio, 8.88; 95% confidence interval [CI], 3.21-24.60) and right atrial volume (odds ratio, 1.03; 95% CI, 1.01-1.04) were independent predictors of SVC foci. CONCLUSION: Patients with SVC foci exhibited more frequent SVC crescent signs and larger right atrial volumes, and these characteristics may help clinicians choose the appropriate ablation technology.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Vena Cava, Superior , Electrocardiography , Heart Atria , Tomography, X-Ray Computed , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome
3.
Circ J ; 2023 Dec 05.
Article in English | MEDLINE | ID: mdl-38057103

ABSTRACT

BACKGROUND: Atrial tachyarrhythmias (ATAs) are reportedly associated with ventricular arrhythmias (VAs). However, little is known about the association between ATA duration and the risk of VA. We investigated the relationship between ATA duration and subsequent VA in patients with a cardiac resynchronization therapy defibrillator (CRT-D).Methods and Results: We investigated associations between the longest ATA duration during the first year after cardiac resynchronization therapy (CRT) implantation and VA and VA relevant to ATA (VAATA) in 160 CRT-D patients. ATAs occurred in 63 patients in the first year. During a median follow-up of 925 days from 1 year after CRT implantation, 40 patients experienced 483 VAs. Kaplan-Meier analysis showed a significantly higher risk of VA in patients with than without ATA in the first year (log rank P=0.0057). Hazard ratios (HR) of VA (HR 2.36, 2.10, and 3.04 for ATA >30s, >6 min and >24 h, respectively) and only VAATA (HR 4.50, 5.59, and 11.79 for ATA >30s, >6 min and >24 h, respectively) increased according to the duration of ATA. In multivariate analysis, ATA >24 h was an independent predictor of subsequent VA (HR 2.42; P=0.02). CONCLUSIONS: Patients with ATA >24 h in the first year after CRT had a higher risk of subsequent VA and VAATA. The risk of VA, including VAATA, increased with the longest ATA duration.

4.
Pacing Clin Electrophysiol ; 46(8): 833-839, 2023 08.
Article in English | MEDLINE | ID: mdl-37485704

ABSTRACT

INTRODUCTION: Infection is one of the most important complications associated with cardiac implantable electronic device (CIED) therapy. The number of reports comparing the outcomes of transvenous lead extraction (TLE), surgical lead extraction, and conservative treatment for CIED infections using a real-world database is limited. This study investigated the association between the treatment strategies for CIED infections and their outcomes. METHODS: We performed a retrospective analysis of 3605 patients with CIED infections admitted to 681 hospitals using a nationwide claim-based database collected between April 2012 and March 2018. RESULTS: We divided the 3605 patients into TLE (n = 938 [26%]), surgical lead extraction (n = 182 [5.0%]), and conservative treatment (n = 2485 [69%]) groups. TLE was performed more frequently in younger patients and at larger hospitals (p for trend < .001 for both). The rate of TLE increased during the study period, whereas that of surgical lead extraction decreased (p for trend < .001 for both). TLE was associated with lower in-hospital mortality (vs. surgical lead extraction: odds ratio [OR], 0.20; 95% CI, 0.06-0.70; vs. conservative treatment: OR, 0.45; 95% CI: 0.22-0.94) and lower 30-day readmission rates (vs. surgical lead extraction: OR, 0.18; 95% CI: 0.06-0.56; vs. conservative treatment: OR, 0.06; 95% CI, 0.03-0.13) in propensity score-weighted analyses. CONCLUSIONS: Only 26% of patients hospitalized for CIED infections received TLE. TLE was associated with significantly lower in-hospital mortality and 30-day recurrence rates than surgical lead extraction and conservative treatment, suggesting that TLE should be more widely recommended as a first-line treatment for CIED infections.


Subject(s)
Defibrillators, Implantable , Heart Diseases , Pacemaker, Artificial , Humans , Defibrillators, Implantable/adverse effects , Pacemaker, Artificial/adverse effects , Conservative Treatment , Retrospective Studies , Propensity Score , Device Removal , Treatment Outcome
5.
J Cardiovasc Electrophysiol ; 33(3): 423-429, 2022 03.
Article in English | MEDLINE | ID: mdl-34921701

ABSTRACT

INTRODUCTION: Utilizing a three-dimensional (3-D) mapping system and intracardiac echocardiography (ICE) has allowed ablation procedures with less or without fluoroscopy; however, there is limited data for patients with cardiac electronic implantable device (CIED) leads regarding the suspected risk of lead injury. Therefore, we sought to explore technics to perform safe trans-septal approach and catheter manipulation technique in patients with CIED leads. METHODS AND RESULTS: This study comprised 49 consecutive patients (59% males, median 73 years old) with CIED who underwent catheter ablation for supraventricular tachycardia requiring the trans-septal approach, 15 without fluoroscopy (zero-fluoro group), and 34 with fluoroscopy (conventional-fluoro group), between July 2019 and April 2021. All procedures were performed under a 3-D mapping system and ICE guidance. We compared the differences in treatment and development of complications between the two groups. The procedures were for atrial fibrillation (82%) and atrial tachycardia (76%). Coronary sinus catheter insertion and the trans-septal procedure were successfully performed in all patients. The median time from venipuncture to trans-septal procedure (zero-fluoro vs. conventional-fluoro group: 28 [18-37] min vs. 24 [21-31] min, p = .70), total procedure time (231 [142-274] min vs. 175 [163-225] min, p = .63), and the acute procedural success rate (100% vs. 97%, p = 1.00) did not differ between both groups. No patient showed lead-related complications in both groups. CONCLUSION: This is the first study to show zero-fluoro ablation for supraventricular arrhythmia using 3-D mapping and ICE in patients with CIED leads was feasible under careful catheter manipulation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Tachycardia, Supraventricular , Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Electronics , Female , Fluoroscopy/methods , Humans , Male , Tachycardia, Supraventricular/diagnostic imaging , Tachycardia, Supraventricular/surgery , Treatment Outcome
6.
Heart Vessels ; 37(5): 794-801, 2022 May.
Article in English | MEDLINE | ID: mdl-34677657

ABSTRACT

Factors causing atrial tachyarrhythmia recurrence after catheter ablation (CA) of atrial fibrillation (AF) remain undetermined. This study aimed to investigate the effect of nocturnal hypoxemia on the recurrence of atrial tachyarrhythmia after CA of AF. Among 594 patients with AF who underwent an ambulatory sleep study at the National Cerebral and Cardiovascular Center, Suita, Osaka, Japan (2014-2019), 365 underwent CA of AF; 290 patients who underwent CA were followed up for > 3 months. Multivariate Cox regression analysis was used to calculate hazard ratios (HRs) using clinical variables, to identify the independent predictors of atrial tachyarrhythmia recurrence after the final CA. Atrial tachyarrhythmia recurred in 45 of 290 (15.5%) patients during the median follow-up period of 479 days (interquartile range 225-1002). On the performing multivariate analysis of the data of patients who did not receive continuous positive airway pressure (CPAP), severe nocturnal hypoxemia [defined as the percentage of sleep time spent with SaO2 of < 90% (T90) over 20%] [HR 8.53, 95% confidence interval (CI) 1.872-38.814; P < 0.01] and an 1 mL/m2 increase in the left atrial volume index (HR 1.02, 95% CI 1.004-1.044; P = 0.02) were found to be independently associated with the recurrence of atrial tachyarrhythmia. In addition, the rates of freedom from atrial tachyarrhythmia after the final AF ablation with CPAP were significantly lower in the group with more severe nocturnal hypoxemia (Log-rank P = 0.03). In conclusion, it is necessary to consider both, AHI and nocturnal hypoxia while performing an ambulatory sleep apnea study. CA may be less effective in patients with more severe nocturnal hypoxia, despite the administration of CPAP.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Heart Atria , Humans , Hypoxia/complications , Recurrence , Risk Factors , Tachycardia/complications , Tachycardia/surgery , Treatment Outcome
7.
Eur Heart J ; 42(29): 2854-2863, 2021 07 31.
Article in English | MEDLINE | ID: mdl-34219138

ABSTRACT

AIMS: The prognostic value of genetic variants for predicting lethal arrhythmic events (LAEs) in Brugada syndrome (BrS) remains controversial. We investigated whether the functional curation of SCN5A variations improves prognostic predictability. METHODS AND RESULTS: Using a heterologous expression system and whole-cell patch clamping, we functionally characterized 22 variants of unknown significance (VUSs) among 55 SCN5A mutations previously curated using in silico prediction algorithms in the Japanese BrS registry (n = 415). According to the loss-of-function (LOF) properties, SCN5A mutation carriers (n = 60) were divided into two groups: LOF-SCN5A mutations and non-LOF SCN5A variations. Functionally proven LOF-SCN5A mutation carriers (n = 45) showed significantly severer electrocardiographic conduction abnormalities and worse prognosis associated with earlier manifestations of LAEs (7.9%/year) than in silico algorithm-predicted SCN5A carriers (5.1%/year) or all BrS probands (2.5%/year). Notably, non-LOF SCN5A variation carriers (n = 15) exhibited no LAEs during the follow-up period. Multivariate analysis demonstrated that only LOF-SCN5A mutations and a history of aborted cardiac arrest were significant predictors of LAEs. Gene-based association studies using whole-exome sequencing data on another independent SCN5A mutation-negative BrS cohort (n = 288) showed no significant enrichment of rare variants in 16 985 genes including 22 non-SCN5A BrS-associated genes as compared with controls (n = 372). Furthermore, rare variations of non-SCN5A BrS-associated genes did not affect LAE-free survival curves. CONCLUSION: In vitro functional validation is key to classifying the pathogenicity of SCN5A VUSs and for risk stratification of genetic predictors of LAEs. Functionally proven LOF-SCN5A mutations are genetic burdens of sudden death in BrS, but evidence for other BrS-associated genes is elusive.


Subject(s)
Brugada Syndrome , Brugada Syndrome/genetics , Humans , Mutation/genetics , NAV1.5 Voltage-Gated Sodium Channel/genetics , Phenotype , Virulence
8.
Int Heart J ; 63(5): 828-836, 2022.
Article in English | MEDLINE | ID: mdl-36184544

ABSTRACT

The efficacy of direct current (DC) cardioversion before catheter ablation (CA) for persistent atrial fibrillation (PerAF) patients remains controversial. We hypothesized that maintenance of sinus rhythm (SR) by pre-ablation DC cardioversion may predict the outcome of CA in patients with PerAF. A total of 383 PerAF patients with no or mild symptoms (EHRA I/II) who had undergone DC cardioversion before CA (301 males, 65 ± 10 years old, mean atrial fibrillation (AF) duration: 25 ± 47 months) were retrospectively enrolled. Whether or not SR was maintained at least 24 hour after DC cardioversion, patients were divided into two groups, namely, the DC-SR group and DC-AF group, and then all were followed until AF recurrence after CA. After DC cardioversion, 281 (73%) patients were categorized into the DC-SR group, and 102 (27%) were categorized into the DC-AF group. A total of 195 patients underwent CA at an average of 83 (54-145) days after DC cardioversion, including 161 (83%) in the DC-SR group and 34 (17%) in the DC-AF group. During follow-up (median: 15 [10-25] months), the number of patients who were free from AF was significantly higher in the DC-SR group compared with the DC-AF group (61.5% versus 38.3%, P < 0.0001). Multivariate analysis revealed that the DC-SR group (hazard ratio [HR]: 0.45, 95% confidence interval [CI]: 0.21-0.99, P = 0.047) and age at first AF diagnosis (HR: 0.95, 95% CI: 0.91-1.00, P = 0.039) were the independent predictors for being AF-free after CA. In conclusion, the 24-hour rhythm outcome of pre-ablation DC cardioversion and age at first AF diagnosis may predict the recurrence of AF after CA in patients with PerAF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Catheter Ablation/adverse effects , Electric Countershock/adverse effects , Humans , Male , Middle Aged , Recurrence , Retrospective Studies , Treatment Outcome
9.
J Cardiovasc Electrophysiol ; 32(5): 1320-1327, 2021 05.
Article in English | MEDLINE | ID: mdl-33600020

ABSTRACT

INTRODUCTION: The sinoatrial node (SAN) should be identified before superior vena cava (SVC) isolation to avoid SAN injury. However, its location cannot be identified without restoring sinus rhythm. This study evaluated the usefulness of the anatomically defined SAN by comparing it with the electrically confirmed SAN (e-SAN) to predict the top-most position of e-SAN and thus establish a safe and more efficient anatomical reference for SVC isolation than the previously reported reference of the right superior pulmonary vein (RSPV) roof. METHODS AND RESULTS: The e-SAN was identified as the earliest activation site in the electroanatomical map obtained during sinus rhythm. The anatomically defined SAN, the cranial edge of the crista terminalis (CT) visualized with intracardiac echocardiography (CT top), and the RSPV roof, which was obtained from the overlaid electroanatomical image of SVC and RSPV, were tagged on one map. The distance from the e-SAN to each reference was measured. Among 77 patients, the height of the e-SAN from the CT top was a median (interquartile range) of -2.0 (-8.0 to 4.0) mm. The e-SAN existed from 10 mm above the CT top or lower in 74 (96%) patients and from the RSPV roof or below in 73 (95%) patients. The reference of 10 mm above the CT top is more proximal to the right atrium than the RSPV roof and can provide longer isolatable SVC sleeves (30.0 [20.0-35.0] vs. 24.0 [18.0-30.0] mm, p < .001). The e-SAN tended to be found above the CT top when the heart rate during mapping was faster (adjusted odds ratio [95% confidence interval] per 10-bpm increase: 1.71 [1.20-2.43], p < .01). CONCLUSION: The CT top is useful for predicting the upper limit of the e-SAN and can provide a better reference for SVC isolation than the RSPV roof.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Sinoatrial Node , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery
10.
J Cardiovasc Electrophysiol ; 32(3): 772-781, 2021 03.
Article in English | MEDLINE | ID: mdl-33428312

ABSTRACT

BACKGROUND: Determining the etiology of syncope is challenging in Brugada syndrome (BrS) patients. Implantable cardioverter defibrillator placement is recommended in BrS patients who are presumed to have arrhythmic syncope. However, arrhythmic syncope in BrS patients can occur in the setting of atrioventricular block (AVB), which should be managed by cardiac pacing. The clinical characteristics of BrS patients with high-risk AVB remain unknown. METHODS: This study included 223 BrS patients with a history of syncope from two centers. The clinical characteristics of patients with high-risk AVB (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB) were investigated. RESULTS: During the 99 ± 78 months of follow-up, we identified six BrS patients (2.7%) with high-risk AVB. Three of the six patients (50%) with AVB presented with syncope associated with prodromes or specific triggers. Four patients (67%) were found to have paroxysmal third-degree AVB during the initial evaluation for BrS and syncope, while two patients developed third-degree AVB during the follow-up period. The incidence of first-degree AVB was significantly higher in AVB patients than in non-AVB patients (83% vs. 15%; p = .0005). There was no significant difference in the incidence of ventricular fibrillation between AVB and non-AVB patients (AVB [17%], non-AVB [12%]; p = .56). CONCLUSION: High-risk AVB can occur in BrS patients with various clinical presentations. Although rare, the incidence is worth considering, especially in BrS patients with first-degree AVB.


Subject(s)
Atrioventricular Block , Brugada Syndrome , Defibrillators, Implantable , Atrioventricular Block/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Electrocardiography , Humans , Syncope/diagnosis , Syncope/epidemiology
11.
Heart Vessels ; 36(5): 675-685, 2021 May.
Article in English | MEDLINE | ID: mdl-33580804

ABSTRACT

Atrial tachycardia (AT) and atrial fibrillation (AF) commonly occur after cardiac surgeries (CSs). This study investigated the mechanisms and long-term outcomes of AT and AF ablation after various Maze procedures, particularly whether atrial tachyarrhythmias after the Maze procedure occur due to gaps in the Maze lines. We analyzed 37 consecutive cases with atrial tachyarrhythmias after the Maze procedures and concomitant CSs between 2007 and 2019. Fifty-nine atrial tachyarrhythmias were induced in 37 consecutive cases, and 49 of those atrial tachyarrhythmias were mappable ATs. Forty ATs were related to the Maze procedures in the 49 mappable ATs (81.6%). All 37 consecutive cases had residual electrical conductions (gaps) in the Maze lines (88 gaps; 2.4 ± 1.2 gaps/patient). Forty of 88 gaps (45.5%) were associated with gap-related ATs. The common ATs in this study were 1. peri-mitral atrial flutter due to gaps at pulmonary vein isolation (PVI) line to mitral valve annulus (MVA) (20 cases), and 2. peri-tricuspid atrial flutter due to gaps at right atrial incision to the tricuspid valve annulus (TVA) (10 cases). Forty-seven of 49 ATs (95.9%) were successfully ablated at the first session, and there were no complications. The mean follow-up period after ablation was 3.6 ± 3.2 (median, 2.1; interquartile range, 0.89-6.84) years. The Kaplan-Meier analysis of freedom from recurrent atrial tachyarrhythmias after Maze procedure was 82.7% at 1-year follow-up and 75.5% at 4-year follow-up after a single procedure. Reentry was the main mechanism of ATs after Maze procedures and concomitant CSs, and ATs were largely related to the gaps on the Maze lines between the PVI line and the MVA or those on the lines between right atrial incision to the TVA. Long-term follow-up data suggest that catheter ablation of atrial tachyarrhythmias after various Maze procedures is effective and safe.


Subject(s)
Atrial Fibrillation/surgery , Cardiac Surgical Procedures/adverse effects , Catheter Ablation/adverse effects , Heart Atria/physiopathology , Pulmonary Veins/surgery , Aged , Atrial Fibrillation/etiology , Atrial Fibrillation/physiopathology , Female , Follow-Up Studies , Humans , Male , Recurrence , Retrospective Studies , Treatment Outcome
12.
Int Heart J ; 62(4): 927-931, 2021 Jul 30.
Article in English | MEDLINE | ID: mdl-34276015

ABSTRACT

A 70-year-old female with dextrocardia with situs inversus (DSI) totalis and inferior vena cava occlusion underwent radiofrequency catheter ablation because she had symptomatic paroxysmal atrial fibrillation (AF). Careful preoperative examination made successful pulmonary vein isolation through the left jugular vein approach. One-year later, however, AF recurred, and symptomatic sinus bradycardia or junctional bradycardia often occurred. Then, the pacemaker was implanted. We here reported a rare case of congenital abnormality, DSI with inferior vena cava occlusion who had undergone successful pulmonary vein isolation and pacemaker implantation without any complications.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Dextrocardia/diagnostic imaging , Pacemaker, Artificial , Sick Sinus Syndrome/surgery , Aged , Atrial Fibrillation/complications , Female , Humans , Situs Inversus
13.
Circ J ; 84(12): 2166-2174, 2020 11 25.
Article in English | MEDLINE | ID: mdl-33162489

ABSTRACT

BACKGROUND: Approximately one-third of patients with advanced heart failure (HF) do not respond to cardiac resynchronization therapy (CRT). We investigated whether the left ventricular (LV) conduction pattern on magnetocardiography (MCG) can predict CRT responders.Methods and Results:This retrospective study enrolled 56 patients with advanced HF (mean [±SD] LV ejection fraction [LVEF] 23±8%; QRS duration 145±19 ms) and MCG recorded before CRT. MCG-QRS current arrow maps were classified as multidirectional (MDC; n=28) or unidirectional (UDC; n=28) conduction based on a change of either ≥35° or <35°, respectively, in the direction of the maximal current arrow after the QRS peak. Baseline New York Heart Association functional class and LVEF were comparable between the 2 groups, but QRS duration was longer and the presence of complete left bundle branch block and LV dyssynchrony was higher in the UDC than MDC group. Six months after CRT, 30 patients were defined as responders, with significantly more in the UDC than MDC group (89% vs. 14%, respectively; P<0.001). Over a 5-year follow-up, Kaplan-Meyer analysis showed that adverse cardiac events (death or implantation of an LV assist device) were less frequently observed in the UDC than MDC group (6/28 vs. 15/28, respectively; P=0.027). Multivariate analysis revealed that UDC on MCG was the most significant predictor of CRT response (odds ratio 69.8; 95% confidence interval 13.14-669.32; P<0.001). CONCLUSIONS: Preoperative non-invasive MCG may predict the CRT response and long-term outcome after CRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Magnetocardiography , Heart Failure/diagnostic imaging , Heart Failure/therapy , Humans , Retrospective Studies , Stroke Volume , Treatment Outcome
14.
Circ J ; 84(12): 2158-2165, 2020 11 25.
Article in English | MEDLINE | ID: mdl-33071242

ABSTRACT

BACKGROUND: The new guideline (NG) published by the Japanese Circulation Society (JCS) places emphasis on previous arrhythmic syncope and inducibility of ventricular fibrillation (VF) by ≤2 extrastimuli during programmed electrical stimulation (PES) for deciding the indication of an implantable cardioverter-defibrillator in patients with Brugada syndrome (BrS). This study evaluated the usefulness of the NG and compared it with the former guideline (FG) for risk stratification of patients with BrS.Methods and Results:This was a multicenter (7 Japanese hospitals) retrospective study involving 234 patients with BrS who underwent PES at baseline (226 males; mean age at diagnosis: 44.9±13.4 years). At diagnosis, 46 patients (20%) had previous VF, 100 patients (43%) had previous syncope, and 88 patients (37%) were asymptomatic. We evaluated the difference in the incidence of VF in each indication according to the new and FGs. During the follow-up period (mean: 6.9±5.2 years), the incidence of VF was higher in patients with Class IIa indication according to the NG (NG: 16/45 patients [35.6%] vs. FG: 16/104 patients [15.4%]), while the incidence of VF in patients with other than class I or IIa indication was similarly low in both guidelines (NG: 2/143 patients [1.4%] vs. FG: 2/84 patients [2.4%]). CONCLUSIONS: This study validated the usefulness of the NG for risk stratification of BrS patients.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Ventricular Fibrillation , Adult , Brugada Syndrome/therapy , Electrocardiography , Female , Humans , Japan/epidemiology , Male , Middle Aged , Practice Guidelines as Topic , Retrospective Studies , Risk Assessment , Syncope , Ventricular Fibrillation/therapy
15.
Circ J ; 84(1): 18-25, 2019 12 25.
Article in English | MEDLINE | ID: mdl-31656236

ABSTRACT

BACKGROUND: Cardiac resynchronization therapy (CRT) is less effective in patients with mildly wide QRS or non-left bundle branch block (non-LBBB). A new algorithm of every minute's optimization (adaptive CRT: aCRT algorithm) is effective in patients with CRT devices. This study investigated the clinical effect of the aCRT algorithm, especially in mildly wide QRS (120≤QRS<150 ms) or non-LBBB patients receiving CRT.Methods and Results:This study included 104 CRT patients (48 patients using the aCRT algorithm [adaptive group] and 56 patients not using the aCRT algorithm [non-adaptive group]). The primary endpoint was a composite clinical outcome of cardiac death and/or heart failure (HF) hospitalization. During a median follow-up of 700 days (interquartile range 362-1,173 days), aCRT reduced the risk of the clinical outcome, even in patients with mildly wide QRS or non-LBBB (log-rank P=0.0030 and P=0.0077, respectively) by Kaplan-Meier analysis. Use of the aCRT algorithm was an independent predictor of clinical outcomes in the multivariate analysis (hazard ratio (HR) 0.28, 95% confidence interval (CI): 0.096-0.78, P=0.015), the same as in patients with mildly wide QRS (HR 0.12, 95% CI: 0.006-0.69, P=0.015). CONCLUSIONS: The new aCRT algorithm was useful and significantly reduced the risk of the clinical outcome, even in patients with mildly wide QRS.


Subject(s)
Algorithms , Bundle-Branch Block/therapy , Cardiac Resynchronization Therapy Devices , Cardiac Resynchronization Therapy , Heart Failure/therapy , Aged , Bundle-Branch Block/mortality , Bundle-Branch Block/physiopathology , Female , Heart Failure/mortality , Heart Failure/physiopathology , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Retrospective Studies
16.
Ann Noninvasive Electrocardiol ; 24(2): e12615, 2019 03.
Article in English | MEDLINE | ID: mdl-30387545

ABSTRACT

BACKGROUND: Detecting asymptomatic and undiagnosed atrial fibrillation (AF) is increasingly important. Recently, we developed a wristwatch-based pulse wave monitor (PWM; Seiko Epson, Japan) capable of long-term recording, with an automatic diagnosis algorithm that uses frequency-based pulse wave analysis. The aim of this study was to evaluate the validity of continuous pulse wave monitoring for detection of AF. METHODS: During the electrophysiological study (EPS) in patients with AF, simultaneous pulse wave monitoring and Holter electrocardiograms (ECG) were recorded (n = 136, mean age 62.7 ± 10.9 years). The diagnostic accuracy of the PWM for AF was compared to the Holter ECG diagnosis. Standard performance metrics (sensitivity [Se], specificity [Sp], positive predictive value [PPV], and negative predictive value [NPV]) were calculated. The duration-based measurements were based on the diagnosis concordance ratios for the duration of time between diagnosis detected by the PWM and true diagnosis by the Holter ECG (AF or not AF). The episode-based performance metrics were based on the proportion of episodes appropriately detected with the PWM relative to episodes determined by the Holter ECG. RESULTS: The total recording time was 1,542,770 s (AF: 270,945 s). A high diagnostic Sp (patient average: 96.4%, cumulative: 97.7%) and NPV (patient average: 95.1%, cumulative: 96.8%) were obtained in the duration-based results. In the episode-based metrics, all indices significantly improved with longer AF episode durations. CONCLUSIONS: Continuous pulse wave monitoring can provide accurate and dependable information to aid in AF diagnosis. A high validity in confirming freedom from AF was shown by a high NPV.


Subject(s)
Algorithms , Atrial Fibrillation/diagnostic imaging , Electrocardiography, Ambulatory/methods , Age Factors , Aged , Atrial Fibrillation/physiopathology , Cohort Studies , Electrocardiography/methods , Female , Humans , Japan , Male , Middle Aged , Pilot Projects , Prospective Studies , Reproducibility of Results , Risk Assessment , Sensitivity and Specificity , Severity of Illness Index , Sex Factors
17.
Circulation ; 135(23): 2255-2270, 2017 Jun 06.
Article in English | MEDLINE | ID: mdl-28341781

ABSTRACT

BACKGROUND: The genotype-phenotype correlation of SCN5A mutations as a predictor of cardiac events in Brugada syndrome remains controversial. We aimed to establish a registry limited to probands, with a long follow-up period, so that the genotype-phenotype correlation of SCN5A mutations in Brugada syndrome can be examined without patient selection bias. METHODS: This multicenter registry enrolled 415 probands (n=403; men, 97%; age, 46±14 years) diagnosed with Brugada syndrome whose SCN5A gene was analyzed for mutations. RESULTS: During a mean follow-up period of 72 months, the overall cardiac event rate was 2.5%/y. In comparison with probands without mutations (SCN5A (-), n=355), probands with SCN5A mutations (SCN5A (+), n=60) experienced their first cardiac event at a younger age (34 versus 42 years, P=0.013), had a higher positive rate of late potentials (89% versus 73%, P=0.016), exhibited longer P-wave, PQ, and QRS durations, and had a higher rate of cardiac events (P=0.017 by log-rank). Multivariate analysis indicated that only SCN5A mutation and history of aborted cardiac arrest were significant predictors of cardiac events (SCN5A (+) versus SCN5A (-): hazard ratio, 2.0 and P=0.045; history of aborted cardiac arrest versus no such history: hazard ratio, 6.5 and P<0.001). CONCLUSIONS: Brugada syndrome patients with SCN5A mutations exhibit more conduction abnormalities on ECG and have higher risk for cardiac events.


Subject(s)
Brugada Syndrome/genetics , Electrocardiography , Genotype , Mutation/genetics , NAV1.5 Voltage-Gated Sodium Channel/genetics , Phenotype , Adolescent , Adult , Aged , Aged, 80 and over , Brugada Syndrome/epidemiology , Brugada Syndrome/physiopathology , Child , Child, Preschool , Electrocardiography/methods , Female , Follow-Up Studies , Humans , Japan/epidemiology , Male , Middle Aged , Registries , Young Adult
18.
Europace ; 20(7): 1107-1114, 2018 07 01.
Article in English | MEDLINE | ID: mdl-28575490

ABSTRACT

Aims: Complications of catheter ablation for atrial fibrillation (AF) are frequently related to vascular access. We hypothesized that ultrasound-guided (USG) venipuncture may facilitate the procedure and reduce complication rates. Methods and results: We conducted a multicentre, randomized trial in patients undergoing catheter ablation for AF on uninterrupted anticoagulation therapy. The study enrolled consecutive 320 patients (age: 63 ± 8 years; male: 62%) and were randomized to USG or conventional venipuncture in 1:1 fashion. It was prematurely terminated due to substantially lower-than-expected complication rates, which doubled the population size needed to maintain statistical power. While the complication rates did not differ between two study arms (0.6% vs. 1.9%, P = 0.62), intra-procedural outcome measures were in favour of the USG approach (puncture time, 288 vs. 369 s, P < 0.001; first pass success, 74% vs. 20%, P < 0.001; extra puncture attempts 0.5 vs. 2.1, P < 0.001; inadvertent arterial puncture 0.07 vs. 0.25, P < 0.001; unsuccessful cannulation 0.6% vs. 14%, P < 0.001). Though these measures varied between trainees (49% of procedures) and expert operators, between-arm differences (except for unsuccessful cannulation) were comparably significant in favour of USG approach for both subgroups. Conclusions: Ultrasound-guided puncture of femoral veins was associated with preferable intra-procedural outcomes, though the major complication rates were not reduced. Both trainees and expert operators benefited from the USG strategy. (www.clinicaltrials.gov ID: NCT02834221).


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Catheterization, Peripheral/methods , Femoral Vein/diagnostic imaging , Ultrasonography, Interventional , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Catheter Ablation/adverse effects , Catheterization, Peripheral/adverse effects , Czech Republic , Early Termination of Clinical Trials , Female , Humans , Japan , Male , Middle Aged , Postoperative Complications/etiology , Punctures , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL