1.
J Appl Clin Med Phys ; 21(1): 110-116, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31909889

ABSTRACT

PURPOSE: To investigate the effects of interfractional variation, such as anatomical changes and setup errors, on dose delivery during treatment for prostate cancer (PC) and head and neck cancer (HNC) by courses of volumetric modulated arc therapy (VMAT) aided by on-treatment electronic portal imaging device (EPID) images. METHODS: Seven patients with PC and 20 patients with HNC who had received VMAT participated in this study. After obtaining photon fluence at the position of the EPID for each treatment arc from on-treatment integrated EPID images, we calculated the differences between the fluence for the first fraction and each subsequent fraction for each arc. The passing rates were investigated based on a tolerance level of 3% of the maximum fluence during the treatment courses and the correlations between the passing rates and anatomical changes. RESULTS: In PC, the median and lowest passing rates were 99.8% and 95.2%, respectively. No correlations between passing rates and interfractional variation were found. In HNC, the median passing rate of all fractions was 93.0%, and the lowest passing rate was 79.6% during the 35th fraction. Spearman's correlation coefficients between the passing rates and changes in weight or neck volume were - 0.77 and - 0.74, respectively. CONCLUSIONS: Analyses of the on-treatment EPID images facilitates estimates of the interfractional anatomical variation in HNC patients during VMAT and thus improves assessments of the need for re-planning or adaptive strategies and the timing thereof.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Image Processing, Computer-Assisted/methods , Prostatic Neoplasms/radiotherapy , Quality Assurance, Health Care/standards , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Algorithms , Female , Humans , Imaging, Three-Dimensional/methods , Male , Middle Aged , Organs at Risk/radiation effects , Radiotherapy Dosage
2.
J Appl Clin Med Phys ; 21(1): 11-17, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31385421

ABSTRACT

This study investigated the effects of respiratory motion, including unwanted breath holding, on the target volume and centroid position on four-dimensional computed tomography (4DCT) imaging. Cine 4DCT images were reconstructed based on a time-based sorting algorithm, and helical 4DCT images were reconstructed based on both the time-based sorting algorithm and an amplitude-based sorting algorithm. A spherical object 20 mm in diameter was moved according to several simulated respiratory motions, with a motion period of 4.0 s and maximum amplitude of 5 mm. The object was extracted automatically, and the target volume and centroid position in the craniocaudal direction were measured using a treatment planning system. When the respiratory motion included unwanted breath-holding times shorter than the breathing cycle, the root mean square errors (RSME) between the reference and imaged target volumes were 18.8%, 14.0%, and 5.5% in time-based images in cine mode, time-based images in helical mode, and amplitude-based images in helical mode, respectively. In helical mode, the RSME between the reference and imaged centroid position was reduced from 1.42 to 0.50 mm by changing the reconstruction method from time- to amplitude-based sorting. When the respiratory motion included unwanted breath-holding times equal to the breathing cycle, the RSME between the reference and imaged target volumes were 19.1%, 24.3%, and 15.6% in time-based images in cine mode, time-based images in helical mode, and amplitude-based images in helical mode, respectively. In helical mode, the RSME between the reference and imaged centroid position was reduced from 1.61 to 0.83 mm by changing the reconstruction method from time- to amplitude-based sorting. With respiratory motion including breath holding of shorter duration than the breathing cycle, the accuracies of the target volume and centroid position were improved by amplitude-based sorting, particularly in helical 4DCT.


Subject(s)
Algorithms , Breath Holding , Four-Dimensional Computed Tomography/methods , Lung Neoplasms/pathology , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiotherapy Planning, Computer-Assisted/methods , Humans , Lung Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods
3.
Article in Japanese | MEDLINE | ID: mdl-28111397

ABSTRACT

In external radiotherapy, the X-ray beam passes through the treatment couch, leading to the dose reduction by the attenuation of the couch. As a method to compensate for the reduction, radiation treatment planning systems (RTPS) support virtual couch function, namely "couch modeling method". In the couch modeling method, the computed tomography (CT) numbers assigned to each structure should be optimized by comparing calculations to measurements for accurate dose calculation. Thus, re-optimization of CT numbers will be required when the dose calculation algorithm or their version changes. The purpose of this study is to evaluate the calculation accuracy of the couch modeling method in different calculation algorithms and their versions. The optimal CT numbers were determined by minimizing the difference between measured transmission factors and calculated ones. When CT numbers optimized by Anisotropic Analytical Algorithm (AAA) Ver. 8.6 were used, the maximum and the mean difference of transmission factor were 5.8% and 1.5%, respectively, for Acuros XB (AXB) Ver. 11.0. However, when CT numbers optimized by AXB Ver. 11.0 were used, they were 2.6% and 0.6%, respectively. The CT numbers for couch structures should be optimized when changing dose calculation algorithms and their versions. From the comparison of the measured transmission to calculation, it was found that the CT numbers had high accuracy.


Subject(s)
Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Technology, Radiologic , Tomography, X-Ray Computed/instrumentation
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(9): 735-45, 2016 09.
Article in Japanese | MEDLINE | ID: mdl-27647596

ABSTRACT

It is generally known that the dose distribution around the high-density materials is not accurate with commercially available radiation treatment planning systems (RTPS). Recently, Acuros XB (AXB) has been clinically available for dose calculation algorithm. The AXB is based on the linear Boltzmann transport equation - the governing equation - that describes the distribution of radiation particles resulting from their interactions with matter. The purpose of this study was to evaluate the dose calculation accuracy around high-density materials for AXB under three X-rays energy on the basis of measured values with EBT3 and compare AXB with various dose calculation algorithms (AAA, XVMC) in RTPS and Monte Carlo. First, two different metals, including titanium and stainless steel, were inserted at the center of a water-equivalent phantom, and the depth dose was measured with EBT3. Next, after a phantom which reproduced the geometry of measurement was virtually created in RTPS, dose distributions were calculated with three commercially available algorithms (AXB, AAA, and XVMC) and MC. The calculated doses were then compared with the measured ones. As a result, compared to other algorithms, it was found that the dose calculation accuracy of AXB at the exit side of high-density materials was comparable to that of MC and measured value with EBT3. However, note that AXB underestimated the dose up to approximately 30% at the plane of incidence because it cannot exactly estimate the impact of the backscatter.


Subject(s)
Radiometry/methods , Algorithms , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Dosage
5.
J Appl Clin Med Phys ; 16(2): 5123, 2015 Mar 08.
Article in English | MEDLINE | ID: mdl-26103180

ABSTRACT

We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for > 3 hr before treatment planning and daily treatment. Each patient was fixed in the supine position on an individualized vacuum pillow. An isotropic margin of 5 mm was added to the clinical target volume to create the planning target volume (PTV). The prescription dose was 42 to 51 Gy in 15 fractions. After correcting initial setup errors based on bony anatomy, the first BH-CBCT scans were performed before beam delivery in every fraction. BH-CBCT acquisition was obtained in three or four times breath holds by interrupting the acquisition two or three times, depending on the patient's BH ability. The image acquisition time for a 360° gantry rotation was approximately 90 s, including the interruption time due to BH. The initial setup errors were corrected based on bony structure, and the residual errors in the target position were then recorded. The magnitude of the interfraction variation in target position was assessed for 165 fractions. The systematic and random errors were 1.2 and 1.8 mm, 1.1 and 1.8 mm, and 1.7 and 2.9 mm in the left-right (LR), anterior-posterior (AP), and superior-inferior (SI) directions, respectively. Absolute interfraction variations of > 5 mm were observed in 18 fractions (11.0%) from seven patients because of EE-BH failure. In conclusion, target matching is required to correct interfraction variation even with visual feedback, especially to ensure safe delivery of escalated doses to patients with pancreatic cancer.


Subject(s)
Breath Holding , Cone-Beam Computed Tomography/methods , Dose Fractionation, Radiation , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/radiotherapy , Patient Positioning , Radiotherapy, Image-Guided/methods , Visual Perception/physiology , Adult , Aged , Female , Humans , Male , Middle Aged , Pancreatic Neoplasms/pathology , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(5): 467-75, 2014 May.
Article in Japanese | MEDLINE | ID: mdl-24858292

ABSTRACT

The purpose of this study was to evaluate the accuracy of positional verification during overall radiation treatment periods in accelerated partial breast irradiation using one or more surgical clips. We first investigated the appropriate computed tomography (CT) slice thickness and detectability of clips for a matching criterion in a phantom study. Next, clinical investigations were carried on 12 patients with multiple clips positioned around the lumpectomy cavity. During radiation treatment planning, a 5-mm region of interest (5-mm ROI) was defined by adding a three dimentional (3D) margin of 5 mm to each clip. During treatment, the clips on two orthogonal kilovoltage X-ray images acquired were moved so as to be included in the corresponding 5-mm ROI on digitally reconstructed radiographs (DRRs). Positional accuracy was calculated using the displacement of each clip in the verification images. The displacements of each clip acquired in all setups were then calculated throughout the overall radiation treatment period and the factors affecting the displacement of clips were investigated. Positional accuracy was also investigated in setups using skin marks and in setups using the bone structure around the thorax. We demonstrated in a phantom study that a CT slice thickness of 2.5 mm was appropriate. In our clinical investigations, 91% of the clips were included in the 5-mm ROI. The interfractional displacement of clips was large, with a long distance between the isocenter and each clip at the time of radiation treatment planning.


Subject(s)
Breast Neoplasms/radiotherapy , Radiotherapy, Image-Guided/instrumentation , Surgical Instruments , Female , Humans , Phantoms, Imaging , Radiotherapy, Image-Guided/methods
7.
J Radiat Res ; 61(1): 104-116, 2020 Jan 23.
Article in English | MEDLINE | ID: mdl-31845998

ABSTRACT

This study aimed to obtain details regarding treatment planning techniques for lung stereotactic body radiation therapy (SBRT) employed at each institution in Japan by using a questionnaire survey. An Internet questionnaire survey on SBRT procedures performed in 2016 was conducted by the QA/QC committee of the Japan Society of Medical Physics from April to June 2017. The questionnaire assessed two aspects: the environment for SBRT at each institution and the treatment planning techniques with and without respiratory motion management techniques (RMMT). Of the 309 evaluated responses, 218 institutions had performed SBRT. A total of 186 institutions performed SBRT without RMMT and 139 institutions performed SBRT with RMMT. When respiratory motion was ≥10 mm, 69 institutions applied RMMT. The leading RMMT were breath holding (77 institutions), respiratory gating (49 institutions) and real-time tumor tracking (11 institutions). The most frequently used irradiation technique was 3D conformal radiotherapy, which was used in 145 institutions without RMMT and 119 institutions with RMMT. Computed tomography (CT) images acquired under free breathing were mostly used for dose calculation for patients treated without RMMT. The usage ratio of IMRT/VMAT to SBRT is low in Japan, compared to elsewhere in the world (<20% vs ≥70%). Among the available dose calculation algorithms, superposition convolution was the most frequently used regardless of RMMT; however, 2% of institutions have not yet made heterogeneity corrections. In the prescription setting, about half of the institutions applied point prescriptions. The survey results revealed the most frequently used conditions, which may facilitate standardization of treatment techniques in lung SBRT.


Subject(s)
Lung Neoplasms/radiotherapy , Radiosurgery , Radiotherapy Planning, Computer-Assisted , Surveys and Questionnaires , Algorithms , Dose-Response Relationship, Radiation , Humans , Japan , Photons , Radiotherapy, Intensity-Modulated
8.
Int J Radiat Oncol Biol Phys ; 72(2): 398-403, 2008 Oct 01.
Article in English | MEDLINE | ID: mdl-18374506

ABSTRACT

PURPOSE: Since 1998, we have treated primary and oligometastatic lung tumors with stereotactic body radiotherapy (SBRT). The term "oligometastasis" is used to indicate a small number of metastases limited to an organ. We evaluated our clinical experience of SBRT for oligometastatic lung tumors. METHODS AND MATERIALS: A total of 34 patients with oligometastatic lung tumors were included in this study. The primary involved organs were the lung (n = 15), colorectum (n = 9), head and neck (n = 5), kidney (n = 3), breast (n = 1), and bone (n = 1). Five to seven, noncoplanar, static 6-MV photon beams were used to deliver 48 Gy (n = 18) or 60 Gy (n = 16) at the isocenter, with 12 Gy/fraction within 4-18 days (median, 12 days). RESULTS: The overall survival rate, local relapse-free rate, and progression-free rate at 2 years was 84.3%, 90.0%, and 34.8%, respectively. No local progression was observed in tumors irradiated with 60 Gy. SBRT-related pulmonary toxicities were observed in 4 (12%) Grade 2 cases and 1 (3%) Grade 3 case. Patients with a longer disease-free interval had a greater overall survival rate. CONCLUSION: The clinical result of SBRT for oligometastatic lung tumors in our institute was comparable to that after surgical metastasectomy; thus, SBRT could be an effective treatment of pulmonary oligometastases.


Subject(s)
Lung Neoplasms/secondary , Lung Neoplasms/surgery , Radiosurgery/methods , Adult , Aged , Aged, 80 and over , Bone Neoplasms , Breast Neoplasms , Colorectal Neoplasms , Dose Fractionation, Radiation , Female , Head and Neck Neoplasms , Humans , Kidney Neoplasms , Lung Neoplasms/mortality , Male , Middle Aged , Radiosurgery/adverse effects , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies
9.
Med Phys ; 35(9): 4142-8, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18841867

ABSTRACT

Since stereotactic body radiotherapy (SBRT) was started for patients with lung tumor in 1998 in our institution, x-ray fluoroscopic examination and slow computed tomography (CT) scan with a rotation time of 4 s have been routinely applied to determine target volumes. When lung tumor motion observed with x-ray fluoroscopy is larger than 8 mm, diaphragm control (DC) is used to reduce tumor motion during respiration. After the installation of a four-dimensional (4D) CT scanner in 2006, 4D CT images have been supplementarily acquired to determine target volumes. It was found that target volumes based on slow CT images were substantially different from those on 4D CT images, even for patients with lung tumor motion no larger than 8 mm. Although slow CT scan might be expected to fare well for lung tumors with motion range of 8 mm or less, the potential limitations of slow CT scan are unknown. The purpose of this study was to evaluate the geometrical differences in target volumes between slow CT and 4D CT imaging for lung tumors with motion range no larger than 8 mm in the upper and middle lobe. Of the patients who underwent SBR between October 2006 and April 2008, 32 patients who had lung tumor with motion range no larger than 8 mm and did not need to use DC were enrolled in this study. Slow CT and 4D CT images were acquired under free breathing for each patient. Target volumes were manually delineated on slow CT images (TV(slow CT)). Gross tumor volumes were also delineated on each of the 4D CT volumes and their union (TV(4D CT)) was constructed. Volumetric and statistical analyses were performed for each patient. The mean +/- standard deviation (S.D.) of TV(slow CT)/TV(4D CT) was 0.75 +/- 0.17 (range, 0.38-1.10). The difference between sizes of TV(slow CT) and TV(4D CT) was not statistically significant (P = 0.096). A mean of 8% volume of TV(slow CT) was not encompassed in TV(4D CT) (mean +/- S.D. = 0.92 +/- 0.07). The patients were separated into two groups to test whether the quality of target delineation on slow CT scans depends on respiratory periods below or above the CT rotation time of 4 s. No significant difference was observed between these groups (P = 0.229). Even lung tumors with motion range no larger than 8 mm might not be accurately depicted on slow CT images. When only a single slow CT scan was used for lung tumors with motion range of 8 mm or less, 95% confidence values for additional margins for TV(slow CT) to encompass TV(4D CT) were 4.0, 5.4, 4.9, 5.1, 1.8, and 1.7 mm for lateral, medial, ventral, dorsal, cranial, and caudal directions, respectively.


Subject(s)
Lung Neoplasms/radiotherapy , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Movement , Radiosurgery , Respiration , Tomography, X-Ray Computed
10.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 64(1): 35-40, 2008 Jan 20.
Article in Japanese | MEDLINE | ID: mdl-18311019

ABSTRACT

BACKGROUND AND PURPOSE: We verified the propriety of our systematic error reduction strategy by means of a computer simulation based on our data of position error with a prone fixation device for prostate IMRT. MATERIALS AND METHODS: Computer simulations of the off-line correction method for systematic setup errors based on the portal imaging taken on the first several days of the treatment session were performed. Using the computer simulations, an optimal number of portal images were evaluated for the SD value, from 0.5 mm to 1.5 mm at a 0.25 mm interval, and the respective required setup margins were calculated. RESULTS: The value of systematic error was reduced as the frequency of data obtained increased. Moreover, the reduction rate was so remarkable that random error was large.


Subject(s)
Radiotherapy/methods , Computer Simulation , Humans , Monte Carlo Method , Retrospective Studies