Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
Langmuir ; 40(1): 853-859, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38146180

ABSTRACT

Precision manipulation of various liquids is essential in many fields such as various thermal, optical, and medical applications. This paper proposes an effective noncontact microdroplet separation method that is based on the action of corona discharge. A blade-plate electrode is constructed to generate an ionic wind, thereby enabling the droplet to be separated according to the shape of the blade electrode. Line, curve, S-shape, and parallel separation of the droplet can be realized in the experiment setup. Furthermore, experiment parameters, including the driving voltage, cutting speed, the distance of the upper and lower electrodes, cutting depth, etc., are discussed. Experimental results show that the proposed method is feasible and effective and can be used in application scenarios that require precise manipulation of droplets.

2.
Langmuir ; 39(44): 15636-15642, 2023 Nov 07.
Article in English | MEDLINE | ID: mdl-37877665

ABSTRACT

Liquid deformation and motion are very common natural phenomena and of great value in various practical applications. In this study, a dielectric fluid column formation and directional flow phenomenon are presented. Dielectric fluid can grow upward to form a liquid column through a spatial electric field and realize directional and controllable operation of the liquid column by regulating spatial electric field distribution. First, the adjustable electric field space is constructed by connecting the two parallel electrodes to the high-voltage DC power supply. Then, the regional electric field distribution was adjusted by the upper plate graphic and power supply regulation to drive the polymer liquid on the lower plate electrode to form a liquid column at different positions. The results show that the polymer liquid column can be driven by the spatial electric field distributed dynamic control method and that the height and the narrowest width of the liquid column are directly controlled by the voltage. With the experiment conditions that the distance between two parallel electrodes is 5-15 mm, the formation of liquid columns with a height of 5-15 mm can be controlled. In addition, the liquid column can be driven by adjusting the on-states of different conductive regions. When the voltage is 10 kV, the liquid column directional movement speed can reach 1 mm/s. The higher the voltage, the faster the directional movement. The research results can be used as producing polydimethylsiloxane stamp, localized heating and temperature control, fabricating a pulsating heat pipe, and so on.

3.
Langmuir ; 37(23): 6967-6973, 2021 06 15.
Article in English | MEDLINE | ID: mdl-34081482

ABSTRACT

Polymer microfluidic technology is widely used in chemistry, biology, medicine, nanoparticles synthesis, and other fields. In this article, we introduce a novel method for the controllable flowing of dielectric fluid droplets. Under the action of corona discharge, the dielectric fluid droplet can be controllably driven to one or more conductive plate electrodes that are connected to the negative electrode on the substrate. Phenomena of polymerization, migration, and separation and merger are experimentally verified in detail, and the spreading speeds and steady-state time are discussed. The experimental results show that the proposed method is accurate and controllable.

4.
Micromachines (Basel) ; 11(2)2020 Feb 10.
Article in English | MEDLINE | ID: mdl-32050671

ABSTRACT

In this paper, a phenomenon of generation and transport of droplets is proposed, which is based on the dielectric liquid electroconvection induced by corona discharge. We placed the dielectric fluid on a conductive/nonconductive substrate, and then it broke apart to become many small droplets that move along the conductive microchannel. The behaviors of dielectric droplets were experimentally observed on different conductive microchannels in details. Spreading speeds and sizes of dielectric droplets were analyzed at different driving voltages and conductive microchannels. This work highlights a simple approach to produce and manipulate dielectric droplets along microchannels.

5.
Data Brief ; 18: 1157-1159, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29896539

ABSTRACT

This article contains data related to the research article entitled "Atomistic simulation on nanomechanical response of indented graphene/nickel system" (Yan et al., 2017). There are five sets of data obtained by molecular dynamics simulations for nanoindentation of five different graphene/nickel systems, which are single nickel system, monolayer graphene on nickel system, double-layer graphene on nickel system, three-layer graphene on nickel system and four-layer graphene on nickel system. The calculated load-displacement of the five different indented systems is also listed.

SELECTION OF CITATIONS
SEARCH DETAIL