Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Neth Heart J ; 32(7-8): 283-289, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38865067

ABSTRACT

INTRODUCTION: When electrical storm (ES) is amenable to neither antiarrhythmic drugs, nor deep sedation or catheter ablation, autonomic modulation may be considered. We report our experience with percutaneous left stellate ganglion block (PSGB) to temporarily suppress refractory ventricular arrhythmia (VA) in patients with structural heart disease. METHODS: A retrospective analysis was performed at our institution of patients with structural heart disease and an implantable cardioverter defibrillator (ICD) who had undergone PSGB for refractory VA between January 2018 and October 2021. The number of times antitachycardia pacing (ATP) was delivered and the number of ICD shocks/external cardioversions performed in the week before and after PSGB were evaluated. Charts were checked for potential complications. RESULTS: Twelve patients were identified who underwent a combined total of 15 PSGB and 5 surgical left cardiac sympathetic denervation procedures. Mean age was 73 ± 5.8 years and all patients were male. Nine of 12 (75%) had ischaemic cardiomyopathy, with the remainder having non-ischaemic dilated cardiomyopathy. Mean left ventricular ejection fraction was 35% (±â€¯12.2%). Eight of 12 (66.7%) patients were already being treated with both amiodarone and beta-blockers. The reduction in ATP did not reach statistical significance (p = 0.066); however, ICD shocks (p = 0.028) and ATP/shocks combined were significantly reduced (p = 0.04). At our follow-up electrophysiology meetings PSGB was deemed ineffective in 4 of 12 patients (33%). Temporary anisocoria was seen in 2 of 12 (17%) patients, and temporary hypotension and hoarseness were reported in a single patient. DISCUSSION: In this limited series, PSGB showed promise as a method for temporarily stabilising refractory VA and ES in a cohort of male patients with structural heart disease. The side effects observed were mild and temporary.

2.
Europace ; 24(2): 313-330, 2022 02 02.
Article in English | MEDLINE | ID: mdl-34878119

ABSTRACT

We aim to provide a critical appraisal of basic concepts underlying signal recording and processing technologies applied for (i) atrial fibrillation (AF) mapping to unravel AF mechanisms and/or identifying target sites for AF therapy and (ii) AF detection, to optimize usage of technologies, stimulate research aimed at closing knowledge gaps, and developing ideal AF recording and processing technologies. Recording and processing techniques for assessment of electrical activity during AF essential for diagnosis and guiding ablative therapy including body surface electrocardiograms (ECG) and endo- or epicardial electrograms (EGM) are evaluated. Discussion of (i) differences in uni-, bi-, and multi-polar (omnipolar/Laplacian) recording modes, (ii) impact of recording technologies on EGM morphology, (iii) global or local mapping using various types of EGM involving signal processing techniques including isochronal-, voltage- fractionation-, dipole density-, and rotor mapping, enabling derivation of parameters like atrial rate, entropy, conduction velocity/direction, (iv) value of epicardial and optical mapping, (v) AF detection by cardiac implantable electronic devices containing various detection algorithms applicable to stored EGMs, (vi) contribution of machine learning (ML) to further improvement of signals processing technologies. Recording and processing of EGM (or ECG) are the cornerstones of (body surface) mapping of AF. Currently available AF recording and processing technologies are mainly restricted to specific applications or have technological limitations. Improvements in AF mapping by obtaining highest fidelity source signals (e.g. catheter-electrode combinations) for signal processing (e.g. filtering, digitization, and noise elimination) is of utmost importance. Novel acquisition instruments (multi-polar catheters combined with improved physical modelling and ML techniques) will enable enhanced and automated interpretation of EGM recordings in the near future.


Subject(s)
Atrial Fibrillation , Cardiology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Body Surface Potential Mapping , Heart Atria , Humans , Latin America
3.
Europace ; 23(6): 887-897, 2021 06 07.
Article in English | MEDLINE | ID: mdl-33582797

ABSTRACT

AIMS: This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation. METHODS AND RESULTS: We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality. CONCLUSION: Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed.


Subject(s)
Defibrillators, Implantable , Angiotensin Receptor Antagonists , Angiotensin-Converting Enzyme Inhibitors , Cohort Studies , Death, Sudden, Cardiac/prevention & control , Humans , Primary Prevention , Risk Factors
4.
J Cardiovasc Electrophysiol ; 25(1): 60-5, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24118293

ABSTRACT

INTRODUCTION: Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. METHODS AND RESULTS: In 105 patients with a Boston Scientific Contak Renewal, Cognis or Energen device implanted for either primary (73.3%) or secondary prevention (26.7%), time domain HRV variables standard deviation of averages of normal beat-to-beat interval (SDANN) and footprint percentage (FPP) were collected at baseline and during follow-up. In case of appropriate shock, HRV before shock was assessed. Using time-dependent Cox regression models, the relation between median-based dichotomized SDANN or FFP and appropriate shock was investigated. Baseline characteristics between patients with or without shocks were similar, with exception of secondary prevention patients using more often antiarrhythmic drugs. During follow-up (median 451, IQR 202-1,460 days), appropriate shocks occurred in 20 (19%) patients. SDANN and FPP did not differ significantly at baseline between patients with or without shocks (respectively, P = 0.18 and P = 0.78). However, time-dependent Cox regression analysis showed a trend that patients were at lower risk for appropriate shock (SDANN: HR 0.43, 95% CI [0.18-1.05], P = 0.06 and FPP: HR 0.49, 95% CI [0.20-1.20], P = 0.12) when HRV values were above median baseline value during follow-up. CONCLUSIONS: These results imply that HRV could be an independent predictor for appropriate shocks. Therefore, low HRV could be of additional use in predicting imminent appropriate shocks and could possibly guide concomitant medical therapy.


Subject(s)
Defibrillators, Implantable , Heart Failure/physiopathology , Heart Failure/therapy , Heart Rate/physiology , Aged , Female , Follow-Up Studies , Heart Failure/diagnosis , Humans , Male , Middle Aged , Predictive Value of Tests
5.
Europace ; 16(1): 40-6, 2014 Jan.
Article in English | MEDLINE | ID: mdl-23918791

ABSTRACT

AIMS: To reduce sudden cardiac death, implantable cardioverter-defibrillators (ICDs) are indicated in patients with ischaemic and non-ischaemic dilated cardiomyopathy and a left ventricular ejection fraction (LVEF) ≤35%. Current guidelines do not recommend device therapy in patients with a life expectancy <1 year since benefit in these patients is low. In this study, we evaluated the incidence and predictors of early mortality (<1 year after implantation) in a consecutive primary prevention population. METHODS AND RESULTS: Analysis was performed on a prediction and validation cohort. The primary endpoint was all-cause mortality at 1 year. The prediction cohort comprised 861 prophylactic ICD recipients with ischaemic cardiomyopathy or dilated cardiomyopathy from the Academic Medical Center (Amsterdam) and Thorax Center Twente (Enschede). Detailed clinical data were collected. After multivariate analysis, a risk score was developed based on age ≥75 years, LVEF ≤ 20%, history of atrial fibrillation, and estimated glomerular filtration rate (eGFR) ≤30 mL/min/1.73 m(2). Using these predictors, a low (≤1 factor), intermediate (2 factors), and high (≥3 factors) risk group could be identified with 1-year mortality of, respectively, 3.4, 10.9, and 38.9% (P< 0.01). Afterwards, the risk score was validated in 706 primary prevention patients from the Erasmus Medical Center (Rotterdam). One-year mortality was, respectively, 2.5, 13.2, and 46.3% (all P< 0.01). CONCLUSION: A simple risk score based on age, LVEF, eGFR, and atrial fibrillation can identify patients at low, intermediate, and high risk for early mortality after ICD implantation. This may be helpful in the risk assessment of ICD candidates.


Subject(s)
Cardiomyopathies/mortality , Cardiomyopathies/prevention & control , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/statistics & numerical data , Risk Assessment/standards , Age Distribution , Aged , Aged, 80 and over , Female , Humans , Incidence , Male , Middle Aged , Netherlands/epidemiology , Prognosis , Reproducibility of Results , Risk Assessment/methods , Sensitivity and Specificity , Sex Distribution , Survival Analysis , Treatment Outcome
6.
Eur Heart J ; 34(3): 211-9, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22584647

ABSTRACT

AIMS: It remains unclear whether primary prophylactic implantable cardioverter-defibrillator (ICD) therapy is cost-effective compared with a 'no ICD strategy' in the European health care setting. We performed a cost-effectiveness analysis for a cohort of patients with a left ventricular ejection fraction <40% and ischaemic or non-ischaemic heart disease. METHODS AND RESULTS: A Markov decision analytic model was used to evaluate long-term survival, quality-adjusted life years (QALYs), and lifetime costs for a cohort of patients with a reduced left ventricular function without previous arrhythmias, managed with a prophylactic ICD. Input data on effectiveness were derived from a meta-analysis of primary prophylactic ICD-only therapy randomized trials, from a prospective cohort study of ICD patients, from a health care utilization survey, and from the literature. Input data on costs were derived from a micro-cost analysis. Data on quality-of-life were derived from the literature. Deterministic and probabilistic sensitivity analysis was performed to assess the uncertainty. Probabilistic sensitivity analysis demonstrated a mean lifetime cost of €50 685 ± €4604 and 6.26 ± 0.64 QALYs for patients in the 'no ICD strategy'. Patients in the 'ICD strategy' accumulated €86 759 ± €3343 and an effectiveness of 7.08 ± 0.71 QALYs yielding an incremental cost-effectiveness ratio of €43 993/QALY gained compared with the 'no ICD strategy'. The probability that ICD therapy is cost-effective was 65% at a willingness-to-pay threshold of €80 000/QALY. CONCLUSION: Our results suggest that primary prophylactic ICD therapy in patients with a left ventricular ejection fraction <40% and ischaemic or non-ischaemic heart disease is cost-effective in the European setting.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/economics , Ventricular Dysfunction, Left/economics , Cardiomyopathy, Dilated/economics , Cardiomyopathy, Dilated/mortality , Cardiomyopathy, Dilated/therapy , Coronary Artery Disease/economics , Coronary Artery Disease/mortality , Coronary Artery Disease/therapy , Cost-Benefit Analysis , Europe/epidemiology , Humans , Markov Chains , Multicenter Studies as Topic , Quality-Adjusted Life Years , Randomized Controlled Trials as Topic , Stroke Volume , Survival Analysis , Ventricular Dysfunction, Left/mortality , Ventricular Dysfunction, Left/therapy
7.
Circulation ; 126(7): 815-21, 2012 Aug 14.
Article in English | MEDLINE | ID: mdl-22869841

ABSTRACT

BACKGROUND: Over the last decades, a gradual decrease in ventricular fibrillation (VF) as initial recorded rhythm during resuscitation for out-of-hospital cardiac arrest (OHCA) has been noted. We sought to establish the contribution of implantable cardioverter-defibrillator (ICD) therapy to this decline. METHODS AND RESULTS: Using a prospective database of all OHCA resuscitation in the province North Holland in the Netherlands (Amsterdam Resuscitation Studies [ARREST]), we collected data on all patients in whom resuscitation for OHCA was attempted in 2005-2008. VF OHCA incidence (per 100 000 inhabitants per year) was compared with VF OHCA incidence data during 1995-1997, collected in a similar way. We also collected ICD interrogations of all ICD patients from North Holland and identified all appropriate ICD shocks in 2005-2008; we calculated the number of prevented VF OHCA episodes, considering that only part of the appropriate shocks would result in avoided resuscitation. VF OHCA incidence decreased from 21.1/100 000 in 1995-1997 to 17.4/100 000 in 2005-2008 (P<0.001). Non-VF OHCA increased from 12.2/100 000 to 19.4/100 000 (P<0.001). VF as presenting rhythm declined from 63% to 47%. In 2005-2008, 1972 ICD patients received 977 shocks. Of these shocks, 339 were caused by a life-threatening arrhythmia. We estimate that these 339 shocks have prevented 81 (minimum, 39; maximum, 152) cases of VF OHCA, corresponding with 33% (minimum, 16%; maximum, 63%) of the observed decline in VF OHCA incidence. CONCLUSIONS: The incidence of VF OHCA decreased over the last 10 years in North Holland. ICD therapy explained a decrease of 1.2/100 000 inhabitants per year, corresponding with 33% of the observed decline in VF OHCA.


Subject(s)
Arrhythmias, Cardiac/prevention & control , Defibrillators, Implantable/statistics & numerical data , Out-of-Hospital Cardiac Arrest/prevention & control , Resuscitation/statistics & numerical data , Aged , Aged, 80 and over , Arrhythmias, Cardiac/mortality , Female , Humans , Incidence , Male , Middle Aged , Netherlands/epidemiology , Treatment Outcome , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/prevention & control
8.
N Engl J Med ; 363(1): 36-44, 2010 Jul 01.
Article in English | MEDLINE | ID: mdl-20463331

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


Subject(s)
Defibrillators, Implantable , Heart Diseases/therapy , Adult , Aged , Aged, 80 and over , Electrocardiography , Electrodes, Implanted , Equipment Design , Female , Heart Diseases/physiopathology , Humans , Male , Middle Aged , Pilot Projects , Stroke Volume , Young Adult
9.
Europace ; 15(2): 290-6, 2013 Feb.
Article in English | MEDLINE | ID: mdl-23024335

ABSTRACT

AIMS: In order to improve the abysmal outcome of dialysis patients, it is critical to identify patients with a high mortality risk. The spatial QRS-T angle, which can be easily calculated from the 12 lead electrocardiogram (ECG), might be useful in the prognostication in dialysis patients. The objective of this study was to establish the prognostic value of the spatial QRS-T angle. METHODS AND RESULTS: All patients who initiated dialysis therapy between 2002 and 2009 in the hospitals of Leiden (LUMC) and Amsterdam (AMC) at least 3 months on dialysis were included. The spatial QRS-T angle was calculated, from a routinely acquired ECG, and its relationship with mortality was assessed. An abnormal spatial QRS-T angle was defined as ≥ 130° in men and ≥ 116° in women. In total, 277 consecutive patients (172 male, mean age 56.3 ± 17.0) were included. An abnormal spatial QRS-T angle was associated with a higher risk of death from all causes [hazard ratio (HR) 2.33; 95% confidence interval (CI) 1.46-3.70] and especially a higher risk of sudden cardiac death (HR 2.99; 95% CI 1.04-8.60). Furthermore, an abnormal spatial QRS-T angle was of incremental prognostic value, when added to a risk model consisting of known risk factors. CONCLUSION: In chronic dialysis patients the spatial QRS-T angle is a significant and independent predictor of all-cause and especially sudden cardiac death. It implies that this parameter can be used to identify high risk patients.


Subject(s)
Electrocardiography/methods , Heart Diseases/diagnosis , Heart Diseases/mortality , Kidney Failure, Chronic/mortality , Renal Dialysis/mortality , Adult , Aged , Cohort Studies , Death, Sudden, Cardiac/epidemiology , Female , Follow-Up Studies , Humans , Incidence , Kaplan-Meier Estimate , Kidney Failure, Chronic/therapy , Male , Middle Aged , Multivariate Analysis , Prognosis , Retrospective Studies , Risk Factors
10.
Circ Genom Precis Med ; 16(4): 328-336, 2023 08.
Article in English | MEDLINE | ID: mdl-37199186

ABSTRACT

BACKGROUND: Genetic variants in TNNI3K (troponin-I interacting kinase) have previously been associated with dilated cardiomyopathy (DCM), cardiac conduction disease, and supraventricular tachycardias. However, the link between TNNI3K variants and these cardiac phenotypes shows a lack of consensus concerning phenotype and protein function. METHODS: We describe a systematic retrospective study of a cohort of patients undergoing genetic testing for cardiac arrhythmias and cardiomyopathy including TNNI3K. We further performed burden testing of TNNI3K in the UK Biobank. For 2 novel TNNI3K variants, we tested cosegregation. TNNI3K kinase function was estimated by TNNI3K autophosphorylation assays. RESULTS: We demonstrate enrichment of rare coding TNNI3K variants in DCM patients in the Amsterdam cohort. In the UK Biobank, we observed an association between TNNI3K missense (but not loss-of-function) variants and DCM and atrial fibrillation. Furthermore, we demonstrate genetic segregation for 2 rare variants, TNNI3K-p.Ile512Thr and TNNI3K-p.His592Tyr, with phenotypes consisting of DCM, cardiac conduction disease, and supraventricular tachycardia, together with increased autophosphorylation. In contrast, TNNI3K-p.Arg556_Asn590del, a likely benign variant, demonstrated depleted autophosphorylation. CONCLUSIONS: Our findings demonstrate an increased burden of rare coding TNNI3K variants in cardiac patients with DCM. Furthermore, we present 2 novel likely pathogenic TNNI3K variants with increased autophosphorylation, suggesting that enhanced autophosphorylation is likely to drive pathogenicity.


Subject(s)
Cardiomyopathy, Dilated , Humans , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/genetics , Retrospective Studies , Arrhythmias, Cardiac/genetics , Genetic Testing , Cardiac Conduction System Disease/genetics , Protein Serine-Threonine Kinases/genetics
11.
Am Heart J ; 163(5): 753-760.e2, 2012 May.
Article in English | MEDLINE | ID: mdl-22607851

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are widely used to prevent fatal outcomes associated with life-threatening arrhythmic episodes in a variety of cardiac diseases. These ICDs rely on transvenous leads for cardiac sensing and defibrillation. A new entirely subcutaneous ICD overcomes problems associated with transvenous leads. However, the role of the subcutaneous ICD as an adjunctive or primary therapy in patients at risk for sudden cardiac death is unclear. STUDY DESIGN: The PRAETORIAN trial is an investigator-initiated, randomized, controlled, multicenter, prospective 2-arm trial that outlines the advantages and disadvantages of the subcutaneous ICD. Patients with a class I or IIa indication for ICD therapy without an indication for bradypacing or tachypacing are included. A total of 700 patients are randomized to either the subcutaneous or transvenous ICD (1:1). The study is powered to claim noninferiority of the subcutaneous ICD with respect to the composite primary endpoint of inappropriate shocks and ICD-related complications. After noninferiority is established, statistical analysis is done for potential superiority. Secondary endpoint comparisons of shock efficacy and patient mortality are also made. CONCLUSION: The PRAETORIAN trial is a randomized trial that aims to gain scientific evidence for the use of the subcutaneous ICD compared with the transvenous ICD in a population of patients with conventional ICD with respect to major ICD-related adverse events. This trial is registered at ClinicalTrials.gov with trial ID NCT01296022.


Subject(s)
Defibrillators, Implantable , Heart Arrest/therapy , Tachycardia, Ventricular/therapy , Cross-Over Studies , Death, Sudden, Cardiac/prevention & control , Double-Blind Method , Electrocardiography , Equipment Design , Equipment Safety , Female , Follow-Up Studies , Heart Arrest/mortality , Heart Conduction System/physiopathology , Humans , Male , Prospective Studies , Risk Assessment , Survival Rate , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/mortality , Treatment Outcome
13.
J Am Heart Assoc ; 10(7): e018063, 2021 04 06.
Article in English | MEDLINE | ID: mdl-33787324

ABSTRACT

Background One third of primary prevention implantable cardioverter-defibrillator patients receive appropriate therapy, but all remain at risk of defibrillator complications. Information on these complications in contemporary cohorts is limited. This study assessed complications and their risk factors after defibrillator implantation in a Dutch nationwide prospective registry cohort and forecasts the potential reduction in complications under distinct scenarios of updated indication criteria. Methods and Results Complications in a prospective multicenter registry cohort of 1442 primary implantable cardioverter-defibrillator implant patients were classified as major or minor. The potential for reducing complications was derived from a newly developed prediction model of appropriate therapy to identify patients with a low probability of benefitting from the implantable cardioverter-defibrillator. During a follow-up of 2.2 years (interquartile range, 2.0-2.6 years), 228 complications occurred in 195 patients (13.6%), with 113 patients (7.8%) experiencing at least one major complication. Most common ones were lead related (n=93) and infection (n=18). Minor complications occurred in 6.8% of patients, with lead-related (n=47) and pocket-related (n=40) complications as the most prevailing ones. A surgical reintervention or additional hospitalization was required in 53% or 61% of complications, respectively. Complications were strongly associated with device type. Application of stricter implant indication results in a comparable proportional reduction of (major) complications. Conclusions One in 13 patients experiences at least one major implantable cardioverter-defibrillator-related complication, and many patients undergo a surgical reintervention. Complications are related to defibrillator implantations, and these should be discussed with the patient. Stricter implant indication criteria and careful selection of device type implanted may have significant clinical and financial benefits.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Electric Countershock , Postoperative Complications , Prosthesis Implantation/adverse effects , Aged , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Defibrillators, Implantable/classification , Defibrillators, Implantable/statistics & numerical data , Electric Countershock/adverse effects , Electric Countershock/instrumentation , Electric Countershock/methods , Equipment Failure Analysis/methods , Equipment Failure Analysis/statistics & numerical data , Female , Humans , Male , Needs Assessment , Netherlands/epidemiology , Patient Selection , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Registries/statistics & numerical data , Reoperation/statistics & numerical data , Risk Assessment , Risk Factors
14.
Pacing Clin Electrophysiol ; 33(2): 192-7, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19889190

ABSTRACT

BACKGROUND: Myocardial scar is an anatomic substrate for potentially lethal arrhythmias. Recent study showed that higher QRS-estimated scar size using the Selvester QRS score was associated with increased arrhythmogenesis during electrophysiologic testing. Therefore, QRS scoring might play a potential role in risk stratification before implantable cardioverter defibrillator (ICD) implantation. In this study, we tested the hypothesis that QRS scores among ICD recipients for secondary prevention are higher than QRS scores in primary prevention patients. METHODS AND RESULTS: From the hospital database, 100 consecutive patients with ischemic heart disease and prior ICD implantation were selected. Twelve-lead electrocardiograms (ECGs) had been obtained before implantation. ECGs were scored following the 32-points Selvester QRS scoring system and corrected for underlying conduction defects and/or hypertrophy. Ninety-three ECGs were suitable for scoring; seven ECGs were rejected because of noise, missing leads, excessive ventricular extrasystoles, or ventricular pacing. No statistically significant difference in QRS score was found between the primary [6.90 (standard deviation [SD] 3.94), n = 63] and secondary prevention group [6.17 (SD 4.50) (P = 0.260), n = 30]. Left ventricular ejection fraction (LVEF) was significantly higher in the secondary prevention group [31% (SD 13.5) vs 24% (SD 11.7) (P = 0.015)]. When patients with LVEF > or =35% were excluded, QRS scores were still comparable, namely 7.02 (SD 4.04) in the primary prevention group (n = 52) and 6.28 (SD 4.24) in the secondary (P = 0.510) (n = 18). CONCLUSION: We found no significant difference in QRS score between the ischemic primary and secondary prevention groups. Therefore, a role of the Selvester QRS score as a risk stratifier remains unlikely.


Subject(s)
Cicatrix/physiopathology , Defibrillators, Implantable , Electrocardiography , Myocardial Ischemia/prevention & control , Myocardial Ischemia/physiopathology , Secondary Prevention , Aged , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/therapy , Female , Humans , Male , Middle Aged , Prospective Studies , Risk Factors , Stroke Volume , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Left/therapy
15.
Eur Heart J Case Rep ; 4(FI1): 1-5, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33089050

ABSTRACT

BACKGROUND: Early studies have led to the repositioning of a subgroup of antimalarial agents (e.g. chloroquine and hydroxychloroquine) as antiviral treatment in coronavirus disease 2019 (COVID-19) patients. These drugs are now being prescribed based on small non-controlled studies, but larger controlled studies have yet to demonstrate the positive effect of these drugs. In addition, these drugs are also known for their QT interval-prolonging effect associated with significant morbidity and mortality. CASE SUMMARY: We present a case of a 66-year-old female admitted to the intensive care unit with respiratory failure due to COVID-19. She was treated with chloroquine (QTc interval at baseline was 429 ms). Despite cessation of chloroquine, but after the start of erythromycin, she developed severe QTc interval prolongation (QTc interval 550 ms) and 'Torsade de Pointes'. Two weeks after cessation of all QTc interval-prolonging drugs, the QTc interval was restored. DISCUSSION: The elimination half-life of chloroquine ranges from days up to weeks. Even after discontinuation of chloroquine, ECG monitoring in COVID-19 patients is warranted. We recommend observation of the QT interval after cessation of chloroquine in cases where other potentially QT interval-prolonging drugs are introduced.

16.
Europace ; 11(10): 1375-80, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19758980

ABSTRACT

AIMS: The absence of microvolt T-wave alternans (MTWA) identifies a group of patients who are at low risk for ventricular arrhythmia or sudden cardiac death. However, in exercised assessed MTWA, 20-40% of all test results are indeterminate. We hypothesised that MTWA during pacing would yield less indeterminate results. METHODS AND RESULTS: Thirty patients with ischaemic cardiomyopathy and prior dual chamber implantable cardioverter defibrillator implantation were enrolled. All patients underwent sequential MTWA testing using an exercise (E), atrial-paced (A), and atrioventricular-paced (AV) protocol. The number of indeterminate tests was lower during pacing (A: 17%; AV: 3%) compared with exercise (37%) (E vs. A: P = 0.015, E vs. AV: P = <0.001). When positive and indeterminate test results were grouped as non-negative, the concordance rates between E and A, E and AV, and A and AV were 60% (kappa = 0.17), 57% (kappa = 0.058), and 70% (kappa = 0.348), respectively. If indeterminate results were excluded, agreements were 60% (kappa = 0.19), 50% (kappa = 0.129) and 67% (kappa = 0.33), respectively. CONCLUSION: Indeterminate test results are less common during pacing. However, there is a low concordance rate between test results using different protocols. This necessitates further study to determine the predictive value of each method in high risk patients with ischaemic cardiomyopathy.


Subject(s)
Cardiac Pacing, Artificial/methods , Cardiomyopathies/diagnosis , Electrocardiography/methods , Exercise Test/methods , Myocardial Ischemia/diagnosis , Cardiomyopathies/complications , Female , Humans , Male , Middle Aged , Myocardial Ischemia/complications , Reproducibility of Results , Sensitivity and Specificity
17.
Eur Heart J Cardiovasc Imaging ; 20(1): 92-100, 2019 01 01.
Article in English | MEDLINE | ID: mdl-29635323

ABSTRACT

Aims: The p.Arg14del founder mutation in the gene encoding phospholamban (PLN) is associated with an increased risk of malignant ventricular arrhythmia (VA) and heart failure. It has been shown to lead to calcium overload, cardiomyocyte damage, and eventually to myocardial fibrosis. This study sought to investigate ventricular function, the extent and localization of myocardial fibrosis and the associations with ECG features and VA in PLN p.Arg14del mutation carriers. Methods and results: Cardiovascular magnetic resonance (CMR) data of 150 mutation carriers were analysed retrospectively. Left ventricular (LV) and right ventricular (RV) volumes, mass, and ejection fraction were measured. The extent of late gadolinium enhancement (LGE) was expressed as a percentage of myocardial mass. All standard ECG parameters were measured. Occurrence of VA was analysed on ambulatory 24-h and/or exercise electrocardiography, if available. Mean age was 40 ± 15 years, 42% males, and 7% were index patients while 93% were pre-symptomatic carriers identified after family cascade screening. Mean LV ejection fraction (LVEF) and RV ejection fraction were 58 ± 9% and 55 ± 9%, respectively. LV-LGE was present in 91% of mutation carriers with reduced LVEF (<45%) and in 30% of carriers with preserved LVEF. In carriers with positive LV-LGE, its median extent was 5.9% (interquartile range 3.2-12.7). LGE was mainly observed in the inferolateral wall. Carriers with inverted T-waves in the lateral ECG leads more often had LV-LGE (P < 0.01) than carriers without. Finally, the presence of LV-LGE, but not attenuated R-waves and inverted lateral T-waves, was independently associated with VA. Conclusion: LV myocardial fibrosis is present in many PLN p.Arg14del mutation carriers, and who still have a preserved LVEF. It is seen predominantly in the LV inferolateral wall and corresponds with electrocardiographic repolarization abnormalities. Although preliminary, myocardial fibrosis was found to be independently associated with VA. Our findings support the use of CMR with LGE early in the diagnostic work-up.


Subject(s)
Calcium-Binding Proteins/genetics , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/genetics , Magnetic Resonance Imaging, Cine/methods , Myocardium/pathology , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/genetics , Adult , Contrast Media , Electrocardiography , Female , Fibrosis/pathology , Genetic Predisposition to Disease , Humans , Image Interpretation, Computer-Assisted , Male , Meglumine , Middle Aged , Mutation , Netherlands , Organometallic Compounds , Phenotype , Retrospective Studies , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/genetics
18.
Stem Cells Transl Med ; 6(1): 22-30, 2017 01.
Article in English | MEDLINE | ID: mdl-28170198

ABSTRACT

Stem cell therapy is a promising therapeutic option to treat patients after myocardial infarction. However, the intramyocardial administration of large amounts of stem cells might generate a proarrhythmic substrate. Proarrhythmic effects can be explained by electrotonic and/or paracrine mechanisms. The narrow therapeutic time window for cell therapy and the presence of comorbidities limit the application of autologous cell therapy. The use of allogeneic or xenogeneic stem cells is a potential alternative to autologous cells, but differences in the proarrhythmic effects of adipose-derived stromal cells (ADSCs) across species are unknown. Using microelectrode arrays and microelectrode recordings, we obtained local unipolar electrograms and action potentials from monolayers of neonatal rat ventricular myocytes (NRVMs) that were cocultured with rat, human, or pig ADSCs (rADSCs, hADSCs, pADSCs, respectively). Monolayers of NRVMs were cultured in the respective conditioned medium to investigate paracrine effects. We observed significant conduction slowing in all cardiomyocyte cultures containing ADSCs, independent of species used (p < .01). All cocultures were depolarized compared with controls (p < .01). Only conditioned medium taken from cocultures with pADSCs and applied to NRVM monolayers demonstrated similar electrophysiological changes as the corresponding cocultures. We have shown that independent of species used, ADSCs cause conduction slowing in monolayers of NRVMs. In addition, pADSCs exert conduction slowing mainly by a paracrine effect, whereas the influence on conduction by hADSCs and rADSCs is preferentially by electrotonic interaction. Stem Cells Translational Medicine 2017;6:22-30.


Subject(s)
Adipose Tissue/cytology , Heart Conduction System/physiology , Animals , Animals, Newborn , Cadherins/metabolism , Connexin 43/metabolism , Culture Media, Conditioned/pharmacology , Gap Junctions/drug effects , Gap Junctions/metabolism , Heart Conduction System/drug effects , Heart Ventricles/cytology , Humans , Male , Membrane Potentials/drug effects , Microelectrodes , Myocytes, Cardiac/cytology , Myocytes, Cardiac/drug effects , Rats, Wistar , Species Specificity , Stromal Cells/cytology , Stromal Cells/drug effects , Stromal Cells/metabolism , Swine
20.
PLoS One ; 12(8): e0183481, 2017.
Article in English | MEDLINE | ID: mdl-28837600

ABSTRACT

BACKGROUND: Stem cell therapy to improve cardiac function after myocardial infarction is hampered by poor cell retention, while it may also increase the risk of arrhythmias by providing an arrhythmogenic substrate. We previously showed that porcine adipose tissue-derived-stromal cells (pASC) induce conduction slowing through paracrine actions, whereas rat ASC (rASC) and human ASC (hASC) induce conduction slowing by direct coupling. We postulate that biomaterial microspheres mitigate the conduction slowing influence of pASC by interacting with paracrine signaling. AIM: To investigate the modulation of ASC-loaded recombinant human collagen-based microspheres, on the electrophysiological behavior of neonatal rat ventricular myocytes (NRVM). METHOD: Unipolar extracellular electrograms, derived from microelectrode arrays (8x8 electrodes) containing NRVM, co-cultured with ASC or ASC loaded microspheres, were used to determine conduction velocity (CV) and conduction heterogeneity. Conditioned medium (Cme) of (co)cultures was used to assess paracrine mechanisms. RESULTS: Microspheres did not affect CV in control (NRVM) monolayers. In co-cultures of NRVM and rASC, hASC or pASC, CV was lower than in controls (14.4±1.0, 13.0±0.6 and 9.0± 1.0 vs. 19.5±0.5 cm/s respectively, p<0.001). Microspheres loaded with either rASC or hASC still induced conduction slowing compared to controls (13.5±0.4 and 12.6±0.5 cm/s respectively, p<0.001). However, pASC loaded microspheres increased CV of NRVM compared to pASC and NRMV co-cultures (16.3±1.3 cm/s, p< 0.001) and did not differ from controls (p = NS). Cme of pASC reduced CV in control monolayers of NRVM (10.3±1.1 cm/s, p<0.001), similar to Cme derived from pASC-loaded microspheres (11.1±1.7 cm/s, p = 1.0). The presence of microspheres in monolayers of NRVM abolished the CV slowing influence of Cme pASC (15.9±1.0 cm/s, p = NS vs. control). CONCLUSION: The application of recombinant human collagen-based microspheres mitigates indirect paracrine conduction slowing through interference with a secondary autocrine myocardial factor.


Subject(s)
Adipose Tissue/cytology , Collagen/administration & dosage , Microspheres , Myocytes, Cardiac/physiology , Stromal Cells/cytology , Action Potentials , Adipose Tissue/ultrastructure , Animals , Connexin 43/metabolism , Culture Media, Conditioned , Humans , Microelectrodes , Microscopy, Electron, Scanning , Rats , Recombinant Proteins/administration & dosage , Stromal Cells/ultrastructure
SELECTION OF CITATIONS
SEARCH DETAIL