Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Article in English | MEDLINE | ID: mdl-38977483

ABSTRACT

PURPOSE: Single-sided deafness (SSD) presents significant challenges for patients, including compromised sound localization, reduced speech recognition, and often, tinnitus. These issues are typically addressed using interventions such as cochlear implantation (CI) and bone conduction implant (BCI). However, evidence regarding the efficacy of BCI in reducing tinnitus in SSD patients remains limited. This study explored the ability of a novel active transcutaneous BCI (Bonebridge BCI602) to alleviate tinnitus in SSD patients. STUDY DESIGN: Prospective cohort multicenter study. SETTING: Tertiary referral hospitals. METHODS: A prospective multicenter study of 30 SSD patients was conducted. The patients were divided into two groups: those with (n = 19) and without (n = 11) tinnitus. Audiometric assessments, subjective questionnaires including the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Bern Benefit in Single-Sided Deafness (BBSS), and tinnitus evaluations with the Tinnitus Handicap Inventory (THI) and tinnitogram were conducted before and after BCI surgery. RESULTS: THI scores after surgery were significantly reduced in SSD patients with tinnitus. Subjective satisfaction improved in both the tinnitus and non-tinnitus groups; however, the former group exhibited a significantly greater improvement in the APHAB questionnaire score. According to tinnitograms, the loudness of tinnitus decreased, particularly in patients with ipsilateral tinnitus. Patients with residual hearing had greater reductions in their THI scores. However, three patients without residual hearing had a relative worsening of tinnitus after surgery. CONCLUSION: The Bonebridge BCI602 effectively reduced tinnitus in SSD patients, particularly in those with residual hearing. Subjective satisfaction improved in both the tinnitus and non-tinnitus groups. These findings demonstrate the therapeutic potential of BCI for managing SSD and associated tinnitus.

2.
Eur Arch Otorhinolaryngol ; 281(2): 683-691, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37552281

ABSTRACT

PURPOSE: To investigate 2-year post-operative hearing performance, safety, and patient-reported outcomes of hearing-impaired adults treated with the Osia® 2 System, an active osseointegrated bone-conduction hearing implant that uses piezoelectric technology. METHODS: A prospective, multicenter, open-label, single-arm, within-subject clinical study conducted at three tertiary referral clinical centers located in Melbourne, Sydney and Hong Kong. Twenty adult recipients of the Osia 2 System were enrolled and followed up between 12 and 24 months post-implantation: 17 with mixed or conductive hearing loss and 3 with single-sided sensorineural deafness. Safety data, audiological thresholds, speech recognition thresholds in noise, and patient-reported outcomes were collected and evaluated. In addition, pre-and 6-month post-implantation data were collected retrospectively for this recipient cohort enrolled into the earlier study (ClinicalTrials.gov NCT04041700). RESULTS: Between 6- and 24-month follow-up, there was no statistically significant change in free-field hearing thresholds or speech reception thresholds in noise (p = > 0.05), indicating that aided improvements were maintained up to 24 months of follow-up. Furthermore, improvements in health-related quality of life and daily hearing ability, as well as clinical and subjective measures of hearing benefit remained stable over the 24-month period. No serious adverse events were reported during extended follow-up. CONCLUSIONS: These study results provide further evidence to support the longer term clinical safety, hearing performance, and patient-related benefits of the Osia 2 System in patients with either a conductive hearing loss, mixed hearing loss, or single-sided sensorineural deafness. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04754477. First posted: February 15, 2021.


Subject(s)
Deafness , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural , Hearing Loss, Sensorineural , Hearing Loss , Speech Perception , Adult , Humans , Hearing Loss, Conductive/surgery , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Follow-Up Studies , Prospective Studies , Quality of Life , Retrospective Studies , Hearing , Bone Conduction , Patient Reported Outcome Measures
3.
Eur Arch Otorhinolaryngol ; 280(10): 4691-4696, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37578496

ABSTRACT

PURPOSE: Hearing rehabilitation through middle ear surgery can be challenging, particularly for patients with chronic otitis media, but new hearing devices offer opportunity to reach this goal. The aim was to compare hearing outcomes and quality of life in patients who were converted from a Baha Attract system to the Osia system. METHODS: Prospective observational study, in which each subject acted as their own control. Six patients who were converted from a Baha Attract to an Osia system performed audiometric and quality of life assessments with different sound processor at fitting, 3, 6 and 12 months. The speech performance in noise with the Osia system at 12 months, expressed as dB SNR, was compared to the baseline condition (Baha 5). RESULTS: The PTA4 hearing thresholds improved from 42.6 ± 11 with Baha 5 Power to 34.8 ± 13.3 with Baha 5 SuperPower and to 25.4 ± 3.5 with the Osia at 12 months, leading to a significant functional gain of 17.2 ± 10.9 dB vs Baha 5 (p < 0.02). Speech understanding in both quiet and noise was clinically improved reaching a mean SNR of less than 1 dB at 12 months with the Osia system. Quality of life outcomes improved by more than 20% at 12-month follow-up. CONCLUSION: Aided hearing thresholds and speech understanding in noise improved when patients were converted from the Baha Attract system to the Osia system. The aided hearing threshold was maintained up to 8 kHz (26 dB) with the Osia system.


Subject(s)
Hearing Aids , Speech Perception , Humans , Bone Conduction , Prospective Studies , Quality of Life , Hearing , Hearing Loss, Conductive/surgery
4.
Eur Arch Otorhinolaryngol ; 279(7): 3387-3398, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34495351

ABSTRACT

PURPOSE: The study aimed to evaluate audiological benefits, quality of hearing and safety of two Bonebridge generation: BCI601 and BCI602 (MED-EL, Innsbruck, Austria) in children. METHODS: Twelve children were implanted: five BCI601 and seven BCI602 comprising of ten conductive hearing loss, and two single sided deaf SSD subjects. Audiological outcomes tested were sound field audiometry, functional gain, speech recognition threshold (SRT50), speech recognition in noise (SPRINT) and localisation abilities. Subjective measures were Speech, Spatial and Qualities of Hearing Scale (SSQ12). RESULTS: The mean FG with the BCI601 was 25.0 dB and with the BCI602 28.0 dB. The benefit in SRT50 was 23.2 dB and 33.8 dB, respectively. The mean benefit in SPRINT was 15% and 6.7% and the localisation ability improved from 33.3° to 16° and from 26.2° to 17.6°, respectively. The two SSD subjects reported a FG of 17 dB, a benefit in SRT50 of 22.5 and a benefit in SPRINT of 20%. Subjective outcomes improved significantly and even exceeded the values of their age-and sex matched normal hearing peers. One revision was reported: a retroauricular emphysema above the implant occurred 12 months post-OP, it was resolved operatively with the implant still being functional. CONCLUSION: The pediatric cohort reports significant audiological benefit, even exceeding that of the age- and sex matched control. The combination of the high safety and audiological benefit makes the Bonebridge a comfortable and effective option in hearing rehabilitation in children.


Subject(s)
Hearing Aids , Speech Perception , Bone Conduction , Child , Hearing , Hearing Loss, Conductive/surgery , Hearing Tests , Humans , Treatment Outcome
5.
Otolaryngol Head Neck Surg ; 170(2): 490-504, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37811702

ABSTRACT

OBJECTIVE: To investigate the safety and efficacy of a novel active transcutaneous bone conduction implant (BCI) device for patients with single-sided deafness (SSD). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral hospitals. METHODS: This prospective multicenter study was conducted at 15 institutions nationwide. Thirty adult (aged ≥19 years) SSD patients were recruited. They underwent implantation of an active transcutaneous BCI device (Bonebridge BCI602). Objective outcomes included aided pure-tone thresholds, aided speech discrimination scores (SDSs), and the Hearing in Noise Test (HINT) and sound localization test results. The Bern Benefit in Single-Sided Deafness (BBSS) questionnaire, the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire, and the Tinnitus Handicap Inventory (THI) were used to measure subjective benefits. RESULTS: The mean aided pure-tone threshold was 34.2 (11.3), mean (SD), dB HL at 500 to 4000 Hz. The mean total BBSS score was 27.5 (13.8). All APHAB questionnaire domain scores showed significant improvements: ease of communication, 33.6 (23.2) versus 22.6 (21.3), P = .025; reverberation, 44.8 (16.6) versus 32.8 (15.9), P = .002; background noise, 55.5 (23.6) versus 35.2 (18.1), P < .001; and aversiveness, 36.7 (22.8) versus 25.8 (21.4), P = .028. Moreover, the THI scores were significantly reduced [47.4 (30.1) versus 31.1 (27.0), P = .003]. Congenital SSD was a significant factor of subjective benefit (-11.643; 95% confidence interval: -21.946 to -1.340). CONCLUSION: The BCI602 active transcutaneous BCI device can provide functional hearing gain without any adverse effects and is a feasible option for acquired SSD patients with long-term deafness.


Subject(s)
Deafness , Hearing Aids , Speech Perception , Tinnitus , Adult , Humans , Prospective Studies , Bone Conduction , Hearing , Deafness/surgery , Treatment Outcome
6.
Laryngoscope Investig Otolaryngol ; 8(2): 591-598, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37090862

ABSTRACT

Objectives: The young population requires early rehabilitation of their hearing loss for normal cognitive, auditive hence social development. All of which, in turn, may have an impact on quality of life (QoL). This study aims to evaluate QoL between two different bone conduction (BC) hearing devices: a noninvasive adhesive hearing aid (Adhear [ADH]) vs. an active transcutaneous implant (Bonebridge [BB]). Methods: This study composed of 12 BB and 15 ADH users. Pure tone as well as speech in noise and quiet measurements were evaluated and compared to the Assessment in QoL questionnaire (AQoL-6d). Results: Freefield results showed significant improvements for both devices compared to the unaided condition (p < .0001). Emphasis needs to be drawn on the different unaided level of conductive hearing loss as well as the indication range for both evaluated device groups: the ADH subjects exhibited a mean BC value of 9.50 ± 7.96 dB HL (the indication range up to 25 dB) and the BB subjects a mean of 23.33 ± 25.66 dB HL (the indication range up to 45 dB). Speech perception in quiet and in noise was significantly improved (p < .05; p < .001, respectively). QoL was significantly improved for both treatments (p < .05) but was not different among the devices, and the values were similar to their normal hearing, age, and sex-matched control group. High correlations were found between QoL utility scores and improved PTA4 in the aided condition (r 2 = .8839 and .7810 for BB and ADH, respectively). Conclusion: Our results show that both devices offer significant beneficial audiological rehabilitations with significantly increased QoL. However, the underlying condition and the unaided degree of hearing loss, hence the required higher stimulation must be the deciding factor when opting for a hearing device, and this should be independent of age. Level of evidence: 2c.

SELECTION OF CITATIONS
SEARCH DETAIL