Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J Card Surg ; 35(12): 3555-3559, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32906188

ABSTRACT

BACKGROUND: Given the recent growth in the number of MitraClip procedures in patients with functional mitral regurgitation (MR), there is interest in an echocardiographic index to predict technical success before intervention. We investigated the utility of a novel leaflet coaptation index (LCI) to predict outcomes after MitraClip in functional MR patients. METHODS: Forty consecutive patients with functional MR who underwent MitraClip were included. The LCI was defined as the coapted leaflet length divided by the anteroposterior diameter of the mitral annulus. The coapted leaflet length was calculated by separately tracing the total length of the mitral valve leaflets at early and end systole on transesophageal echocardiography. The primary endpoint was defined as residual MR ≥ moderate after MitraClip. RESULTS: The LCI was significantly associated with residual MR ≥ moderate (odds ratio, 0.827; 95% confidence interval, 0.696-0.982; p = .030) with the cut-off LCI value of 0.14 (sensitivity 70.4%, specificity 69.2%, c-statistic 0.815; p = .001). CONCLUSION: This novel index may be a useful adjunct that can be incorporated into the armamentarium of contemporary clinical performance risk prediction tools for MitraClip success.


Subject(s)
Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Echocardiography, Transesophageal , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Time Factors , Treatment Outcome
2.
Internist (Berl) ; 58(11): 1222-1230, 2017 Nov.
Article in German | MEDLINE | ID: mdl-28932873

ABSTRACT

BACKGROUND: The tricuspid valve can be considered the "forgotten" valve because in the past hardly any research has been conducted in this field and as a result only few therapeutic options existed. The prognosis of untreated tricuspid regurgitation (TR) is poor and mortality is high for patients with severe TR. Patients frequently return to medical practices and hospitals because of cardiac decompensation, with shortness of breath and leg edema. OBJECTIVE: Recent years have seen more development in catheter-based treatment options. Currently, several devices are in clinical evaluation, which are presented in this article. MATERIAL AND METHODS: A web-based literature search was carried out and information was gathered at international cardiology meetings (TCT 2016 in Washington, DGK 2017 in Mannheim, EuroPCR 2017 in Paris). RESULTS AND CONCLUSION: There are various options for interventional catheter procedures for TR, which are being investigated within the scope of clinical studies. Most aim at reducing the tricuspid annular diameter and optimizing leaflet coaptation. Because of these new therapy options patients can now be treated who were considered untreatable in the past because of the high perioperative mortality.


Subject(s)
Cardiac Catheterization/methods , Tricuspid Valve Insufficiency/surgery , Humans , Postoperative Complications/mortality , Survival Rate , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/mortality
4.
Eur J Heart Fail ; 18(10): 1278-1286, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27102848

ABSTRACT

AIMS: The aim of this study was to investigate the feasibility, safety, and efficacy of Mitraclip therapy in patients with functional mitral regurgitation (MR) and missing leaflet coaptation (MLC). METHODS AND RESULTS: Out of 62 consecutive patients with functional MR undergoing Mitraclip implantation, 22 had MLC defined as the presence of a 'gap' between two mitral leaflets or insufficient coaptation length (<2 mm), according to the EVEREST II criterion. Compared with the control group, the MLC population had a significantly higher effective regurgitant orifice area (0.67 ± 0.31 vs. 0.41 ± 0.13 cm2 ; P = 0.019) and sphericity index (0.80 ± 0.11 vs. 0.71 ± 0.10; P = 0.003). MLC patients were treated with pharmacological/mechanical support in order to improve leaflet coaptation and to prepare the mitral valve apparatus for grasping. Implantation of >1 clip and device time were comparable in patients with and without MLC (61.9% vs. 47.5%; P = 0.284 and 101 ± 39 vs. 108 ± 69 min; P = 0.646, respectively). No significant differences were observed between the two cohorts in technical success (95.5% vs. 97.5%, P = 0.667), 30-day device success (85.7% vs. 78.9%; P = 0.525), procedural success (81.8% vs. 75%; P = 0.842), and 1-year patient success (52.9% vs. 44.1%; P = 0.261), defined according to the MVARC (Mitral Valve Academic Research Consortium) criteria. The long-term composite endpoint of cardiovascular death and heart failure hospitalization was similar in the two groups (49.9% vs. 44.4%; P = 0.348). A significant improvement of MR and NYHA functional class and a lack of reverse remodelling were observed up to 2 years in both arms. CONCLUSION: The Mitraclip procedure could be extended to patients with functional MR who do not fulfil the coaptation length EVEREST II criterion and who would otherwise be excluded from this treatment.


Subject(s)
Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Female , Heart Valve Prosthesis , Heart Valves/physiopathology , Heart Valves/surgery , Humans , Male , Middle Aged , Mitral Valve/physiopathology , Mitral Valve Insufficiency/physiopathology , Retrospective Studies , Surgical Instruments , Treatment Outcome
5.
J Am Coll Cardiol ; 65(21): 2331-6, 2015 Jun 02.
Article in English | MEDLINE | ID: mdl-26022823

ABSTRACT

The assessment of the etiology and severity of functional tricuspid regurgitation (FTR) has many limitations, especially when tricuspid regurgitation (TR) is more than severe. Instead of relying solely on TR severity, a new approach not only takes into account the severity of TR, but also pays strict attention to tricuspid annular dilation (size), the mode of tricuspid leaflet coaptation, and tricuspid leaflet tethering-factors often influenced by right ventricular enlargement and dysfunction. To simplify things, we propose a new staging system for functional tricuspid valve pathology using 3 parameters that may more accurately reflect the severity of the disease: TR severity, annular dilation, and mode of leaflet coaptation (extent of tethering). We believe that by utilizing these parameters, cardiologists and cardiac surgeons will be offered a better system for appraisal and decision-making in FTR.


Subject(s)
Severity of Illness Index , Tricuspid Valve Insufficiency/pathology , Tricuspid Valve/pathology , Humans , Tricuspid Valve/physiopathology , Tricuspid Valve Insufficiency/physiopathology
6.
Biomed Mater Eng ; 24(1): 7-13, 2014.
Article in English | MEDLINE | ID: mdl-24211876

ABSTRACT

Ischemic mitral valve (MV) is a common complication of pathologic remodeling of the left ventricle due to acute and chronic coronary artery diseases. It frequently represents the pathologic consequences of increased tethering forces and reduced coaptation of the MV leaflets. Ischemic MV function has been investigated from a biomechanical perspective using finite element-based computational MV evaluation techniques. A virtual 3D MV model was created utilizing 3D echocardiographic data in a patient with normal MV. Two types of ischemic MVs containing asymmetric medial-dominant or symmetric leaflet tenting were modeled by altering the configuration of the normal papillary muscle (PM) locations. Computational simulations of MV function were performed using dynamic finite element methods, and biomechanical information across the MV apparatus was evaluated. The ischemic MV with medial-dominant leaflet tenting demonstrated distinct large stress distributions in the posteromedial commissural region due to the medial PM displacement toward the apical-medial direction resulting in a lack of leaflet coaptation. In the ischemic MV with balanced leaflet tenting, mitral incompetency with incomplete leaflet coaptation was clearly identified all around the paracommissural regions. This computational MV evaluation strategy has the potential for improving diagnosis of ischemic mitral regurgitation and treatment of ischemic MVs.


Subject(s)
Cardiomyopathies/physiopathology , Mitral Valve/physiopathology , Myocardial Ischemia/pathology , Biomechanical Phenomena , Computer Simulation , Coronary Artery Disease/physiopathology , Echocardiography , Finite Element Analysis , Humans , Imaging, Three-Dimensional , Mitral Valve Insufficiency/physiopathology , Papillary Muscles/physiopathology , Stress, Mechanical
SELECTION OF CITATIONS
SEARCH DETAIL