Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.180
Filter
Add more filters

Publication year range
1.
Microcirculation ; 31(5): e12853, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38690605

ABSTRACT

OBJECTIVE: Both low serum albumin (SA) concentration and coronary microvascular dysfunction (CMD) are risk factors for the development of heart failure (HF). We hypothesized that SA concentration is associated with myocardial flow reserve (MFR) and implicated in pathophysiological mechanism of HF. METHODS: We retrospectively studied 454 patients undergoing dynamic cardiac cadmium-zinc-telluride myocardial perfusion imaging from April 2018 to February 2020. The population was categorized into three groups according to SA level (g/dL): Group 1: >4, Group 2: 3.5-4, and Group 3: <3.5. Myocardial blood flow (MBF) and myocardial flow reserve (MFR, defined as stress/rest MBF ratio) were compared. RESULTS: The mean age of the whole cohort was 66.2 years, and 65.2% were men. As SA decreased, stress MBF (mL min-1 g-1) and MFR decreased (MBF: 3.29 ± 1.03, MFR: 3.46 ± 1.33 in Group 1, MBF: 2.95 ± 1.13, MFR: 2.51 ± 0.93 in Group 2, and MBF: 2.64 ± 1.16, MFR: 1.90 ± 0.50 in Group 3), whereas rest MBF (mL min-1 g-1) increased (MBF: 1.05 ± 0.42 in Group 1, 1.27 ± 0.56 in Group 2, and 1.41 ± 0.61 in Group 3). After adjusting for covariates, compared with Group 1, the odds ratios for impaired MFR (defined as MFR < 2.5) were 3.57 (95% CI: 2.32-5.48) for Group 2 and 34.9 (95% CI: 13.23-92.14) for Group 3. The results would be similar if only regional MFR were assessed. The risk prediction for CMD using SA was acceptable, with an AUC of 0.76. CONCLUSION: Low SA concentration was associated with the severity of CMD in both global and regional MFR as well as MBF.


Subject(s)
Cadmium , Coronary Circulation , Tellurium , Tomography, Emission-Computed, Single-Photon , Zinc , Humans , Male , Female , Aged , Middle Aged , Retrospective Studies , Zinc/blood , Cadmium/blood , Microcirculation , Myocardial Perfusion Imaging/methods , Heart Failure/physiopathology , Heart Failure/blood , Heart Failure/diagnostic imaging , Zinc Compounds , Serum Albumin
2.
Cardiovasc Diabetol ; 23(1): 187, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822373

ABSTRACT

BACKGROUND: Ischemia and no obstructive coronary artery disease (INOCA) is increasingly recognized and associated with poor outcomes. The triglyceride-glucose (TyG) index is a reliable alternative measure of insulin resistance significantly linked to cardiovascular disease and adverse prognosis. We investigated the association between the TyG index and myocardial ischemia and the prognosis in INOCA patients. METHODS: INOCA patients who underwent both coronary angiography and myocardial perfusion imaging (MPI) were included consecutively. All participants were divided into three groups according to TyG tertiles (T1, T2, and T3). Abnormal MPI for myocardial ischemia in individual coronary territories was defined as summed stress score (SSS) ≥ 4 and summed difference score (SDS) ≥ 2. SSS refers to the sum of all defects in the stress images, and SDS is the difference of the sum of all defects between the rest images and stress images. All patients were followed up for major adverse cardiac events (MACE). RESULTS: Among 332 INOCA patients, 113 (34.0%) had abnormal MPI. Patients with higher TyG index had a higher rate of abnormal MPI (25.5% vs. 32.4% vs. 44.1%; p = 0.012). Multivariate logistic analysis showed that a high TyG index was significantly correlated with abnormal MPI in INOCA patients (OR, 1.901; 95% CI, 1.045-3.458; P = 0.035). During the median 35 months of follow-up, 83 (25%) MACE were recorded, and a higher incidence of MACE was observed in the T3 group (T3 vs. T2 vs. T1: 36.9% vs. 21.6% vs. 16.4%, respectively; p = 0.001). In multivariate Cox regression analysis, the T3 group was significantly associated with the risk of MACE compared to the T1 group (HR, 2.338; 95% CI 1.253-4.364, P = 0.008). CONCLUSION: This study indicates for the first time that the TyG index is significantly associated with myocardial ischemia and poor prognosis among INOCA patients.


Subject(s)
Biomarkers , Blood Glucose , Coronary Angiography , Myocardial Ischemia , Myocardial Perfusion Imaging , Predictive Value of Tests , Triglycerides , Humans , Male , Female , Middle Aged , Aged , Triglycerides/blood , Prognosis , Myocardial Ischemia/blood , Myocardial Ischemia/diagnosis , Myocardial Ischemia/mortality , Myocardial Ischemia/epidemiology , Biomarkers/blood , Blood Glucose/metabolism , Risk Factors , Risk Assessment , Retrospective Studies , Time Factors , Coronary Artery Disease/blood , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Insulin Resistance
3.
Eur J Clin Invest ; 54(6): e14178, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38348627

ABSTRACT

BACKGROUND: Given the limited access to invasive vasospastic reactivity testing in Western Countries, there is a need to further develop alternative non-invasive diagnostic methods for vasospastic angina (VSA). Hyperventilation testing (HVT) is defined as a class IIa recommendation to diagnose VSA by the Japanese Society of Cardiology. METHODS: In this systematic review and meta-analysis reported according to the PRISMA statement, we review the mechanisms, methods, modalities and diagnostic accuracy of non-invasive HVT for the diagnostic of VSA. RESULTS: A total of 106 articles published between 1980 and 2022 about VSA and HVT were included in the systematic review, among which 16 were included in the meta-analysis for diagnostic accuracy. Twelve electrocardiogram-HVT studies including 804 patients showed a pooled sensitivity of 54% (95% confidence intervals [CI]; 30%-76%) and a pooled specificity of 99% (95% CI; 88%-100%). Four transthoracic echocardiography-HVT studies including 197 patients revealed a pooled sensitivity of 90% (95% CI; 82%-94%) and a pooled specificity of 98% (95% CI; 86%-100%). Six myocardial perfusion imaging-HVT studies including 112 patients yielded a pooled sensitivity of 95% (95% CI; 63%-100%) and a pooled specificity of 78% (95% CI; 19%-98%). Non-invasive HVT resulted in a low rate of adverse events, ventricular arrhythmias being the most frequently reported, and were resolved with the administration of nitroglycerin. CONCLUSIONS: Non-invasive HVT offers a safe alternative with high diagnostic accuracy to diagnose VSA in patients with otherwise undiagnosed causes of chest pain.


Subject(s)
Coronary Vasospasm , Echocardiography , Electrocardiography , Hyperventilation , Humans , Hyperventilation/diagnosis , Hyperventilation/physiopathology , Coronary Vasospasm/diagnosis , Coronary Vasospasm/physiopathology , Angina Pectoris/diagnosis , Angina Pectoris/physiopathology , Sensitivity and Specificity , Myocardial Perfusion Imaging
4.
Eur J Nucl Med Mol Imaging ; 51(7): 1869-1875, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38407598

ABSTRACT

PURPOSE: Long axial field-of-view (LAFOV) positron emission tomography (PET) systems allow to image all major organs with one bed position, which is particularly useful for acquiring whole-body dynamic data using short-lived radioisotopes like 82Rb. METHODS: We determined the absorbed dose in target organs of three subjects (29, 40, and 57 years old) using two different methods, i.e., MIRD and voxel dosimetry. The subjects were injected with 407.0 to 419.61 MBq of [82Rb]Cl and were scanned dynamically for 7 min with a LAFOV PET/CT scanner. RESULTS: Using the MIRD formalism and voxel dosimetry, the absorbed dose ranged from 1.84 to 2.78 µGy/MBq (1.57 to 3.92 µGy/MBq for voxel dosimetry) for the heart wall, 2.76 to 5.73 µGy/MBq (3.22 to 5.37 µGy/MBq for voxel dosimetry) for the kidneys, and 0.94 to 1.88 µGy/MBq (0.98 to 1.92 µGy/MBq for voxel dosimetry) for the lungs. The total body effective dose lied between 0.50 and 0.76 µSv/MBq. CONCLUSION: Our study suggests that the radiation dose associated with [82Rb]Cl PET/CT can be assessed by means of dynamic LAFOV PET and that it is lower compared to literature values.


Subject(s)
Positron Emission Tomography Computed Tomography , Radiometry , Rubidium Radioisotopes , Humans , Positron Emission Tomography Computed Tomography/methods , Middle Aged , Adult , Radiometry/methods , Male , Radiation Dosage , Female
5.
Eur J Nucl Med Mol Imaging ; 51(6): 1622-1631, 2024 May.
Article in English | MEDLINE | ID: mdl-38253908

ABSTRACT

PURPOSE: The myocardial creep is a phenomenon in which the heart moves from its original position during stress-dynamic PET myocardial perfusion imaging (MPI) that can confound myocardial blood flow measurements. Therefore, myocardial motion correction is important to obtain reliable myocardial flow quantification. However, the clinical importance of the magnitude of myocardial creep has not been explored. We aimed to explore the prognostic value of myocardial creep quantified by an automated motion correction algorithm beyond traditional PET-MPI imaging variables. METHODS: Consecutive patients undergoing regadenoson rest-stress [82Rb]Cl PET-MPI were included. A newly developed 3D motion correction algorithm quantified myocardial creep, the maximum motion at stress during the first pass (60 s), in each direction. All-cause mortality (ACM) served as the primary endpoint. RESULTS: A total of 4,276 patients (median age 71 years; 60% male) were analyzed, and 1,007 ACM events were documented during a 5-year median follow-up. Processing time for automatic motion correction was < 12 s per patient. Myocardial creep in the superior to inferior (downward) direction was greater than the other directions (median, 4.2 mm vs. 1.3-1.7 mm). Annual mortality rates adjusted for age and sex were reduced with a larger downward creep, with a 4.2-fold ratio between the first (0 mm motion) and 10th decile (11 mm motion) (mortality, 7.9% vs. 1.9%/year). Downward creep was associated with lower ACM after full adjustment for clinical and imaging parameters (adjusted hazard ratio, 0.93; 95%CI, 0.91-0.95; p < 0.001). Adding downward creep to the standard PET-MPI imaging model significantly improved ACM prediction (area under the receiver operating characteristics curve, 0.790 vs. 0.775; p < 0.001), but other directions did not (p > 0.5). CONCLUSIONS: Downward myocardial creep during regadenoson stress carries additional information for the prediction of ACM beyond conventional flow and perfusion PET-MPI. This novel imaging biomarker is quantified automatically and rapidly from stress dynamic PET-MPI.


Subject(s)
Heart , Myocardial Perfusion Imaging , Positron-Emission Tomography , Humans , Male , Female , Aged , Myocardial Perfusion Imaging/methods , Heart/diagnostic imaging , Middle Aged , Myocardium/pathology , Rubidium Radioisotopes , Stress, Physiological , Prognosis
6.
Eur J Nucl Med Mol Imaging ; 51(6): 1632-1638, 2024 May.
Article in English | MEDLINE | ID: mdl-38105304

ABSTRACT

PURPOSE: To prospectively compare changes in myocardial blood flow (MBF) and myocardial flow reserve (MFR) in multivessel coronary artery disease (MVCAD) patients undergoing incomplete revascularization (IR) versus complete revascularization (CR) by coronary artery bypass grafting (CABG). METHODS: Seven male patients (age 68 ± 9 years) with MVCAD underwent myocardial perfusion PET/CT with [13N]ammonia before and at least 4 months after CABG. Segmental resting and stress MBF as well as MFR were measured. Resting and during stress left ventricle ejection fraction (LVEF) were also calculated. RESULTS: Three patients (43%) underwent CR and four (57%) IR. Among 119 myocardial segments, 101 (85%) were revascularized, and 18 (15%) were not. After CABG, stress MBF (mL/min/gr) and MFR are significantly increased in all myocardial segments, with a greater increase in the revascularized segments (p = 0.013). In both groups, LVEF significantly decreased during stress at baseline PET (p = 0.04), but not after CABG. CONCLUSION: Stress MBF and MFR significantly improve after CABG in both revascularized and not directly revascularized myocardial segments. IR strategy may be considered in patients with high surgical risk for CR.


Subject(s)
Coronary Artery Bypass , Coronary Circulation , Heart , Myocardial Perfusion Imaging , Myocardium , Positron Emission Tomography Computed Tomography , Aged , Humans , Male , Middle Aged , Heart/diagnostic imaging , Myocardium/metabolism , Pilot Projects , Ventricular Function, Left
7.
Eur Radiol ; 2024 Jul 12.
Article in English | MEDLINE | ID: mdl-38995383

ABSTRACT

OBJECTIVES: We aimed to explore the imaging profile of coronary atherosclerosis, perivascular inflammation, myocardial perfusion, and interstitial fibrosis in diabetes stratified by lipoprotein(a) [Lp(a)] levels. METHODS: In this prospective study, we enrolled diabetic patients who had undergone computed tomography (CT) angiography, stress CT-myocardial perfusion imaging, and late iodine enhancement in 20 months. Then, we categorized them into elevated and normal groups based on an Lp(a) cutoff level of 30 mg/dL. All imaging data, including coronary atherosclerosis parameters, pericoronary adipose tissue (PCAT) density, stress myocardial blood flow (MBF), and extracellular volume (ECV), were collected for further analysis. RESULTS: In total, 207 participants (mean age: 59.1 ± 12.0 years, 111 males) were included in this study. Patients with elevated Lp(a) level had more pronounced percent atheroma volume (2.55% (1.01-9.01%) versus 1.30% (0-4.95%), p = 0.010), and demonstrated a higher incidence of positive remodeling, spotty calcification, and high-risk plaque (HRP) than those with normal Lp(a) levels (75.6% versus 54.8%, p = 0.015; 26.8% versus 9.6%, p = 0.003; 51.2% versus 30.1%, p = 0.011, respectively). Results of the multivariate analysis revealed that after adjusting for all clinical characteristics, elevated Lp(a) levels were an independent parameter associated with HRP (odds ratio = 2.608; 95% confidence interval: 1.254-5.423, p = 0.010). However, no significant difference was found between the two groups in terms of PCAT density, stress MBF, and ECV. CONCLUSIONS: Elevated Lp(a) levels are associated with extensive coronary atherosclerosis and HRP development. However, they are not related to perivascular inflammation, decreased myocardial perfusion, and interstitial fibrosis in diabetes. CLINICAL RELEVANCE STATEMENT: Elevated lipoprotein(a) levels are associated with extensive coronary atherosclerosis and a high incidence of HRPs. However, they are not related to perivascular inflammation, decreased myocardial perfusion, and interstitial fibrosis in diabetes. KEY POINTS: Diabetes is a known risk factor that accelerates cardiovascular disease progression. Diabetics with elevated lipoprotein(a) (Lp(a)) levels had a higher percent atheroma volume and positive remodeling, spotty calcification, and HRPs. Patients with diabetes should be screened for elevated Lp(a) using CCTA for comprehensive evaluation of atherosclerotic characteristics.

8.
Eur Radiol ; 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38409549

ABSTRACT

OBJECTIVES: To compare the diagnostic performance of machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and cardiac magnetic resonance (MR) perfusion mapping for functional assessment of coronary stenosis. METHODS: Between October 2020 and March 2022, consecutive participants with stable coronary artery disease (CAD) were prospectively enrolled and underwent coronary CTA, cardiac MR, and invasive fractional flow reserve (FFR) within 2 weeks. Cardiac MR perfusion analysis was quantified by stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Hemodynamically significant stenosis was defined as FFR ≤ 0.8 or > 90% stenosis on invasive coronary angiography (ICA). The diagnostic performance of CT-FFR, MBF, and MPR was compared, using invasive FFR as a reference. RESULTS: The study protocol was completed in 110 participants (mean age, 62 years ± 8; 73 men), and hemodynamically significant stenosis was detected in 36 (33%). Among the quantitative perfusion indices, MPR had the largest area under receiver operating characteristic curve (AUC) (0.90) for identifying hemodynamically significant stenosis, which is in comparison with ML-based CT-FFR on the vessel level (AUC 0.89, p = 0.71), with comparable sensitivity (89% vs 79%, p = 0.20), specificity (87% vs 84%, p = 0.48), and accuracy (88% vs 83%, p = 0.24). However, MPR outperformed ML-based CT-FFR on the patient level (AUC 0.96 vs 0.86, p = 0.03), with improved specificity (95% vs 82%, p = 0.01) and accuracy (95% vs 81%, p < 0.01). CONCLUSION: ML-based CT-FFR and quantitative cardiac MR showed comparable diagnostic performance in detecting vessel-specific hemodynamically significant stenosis, whereas quantitative perfusion mapping had a favorable performance in per-patient analysis. CLINICAL RELEVANCE STATEMENT: ML-based CT-FFR and MPR derived from cardiac MR performed well in diagnosing vessel-specific hemodynamically significant stenosis, both of which showed no statistical discrepancy with each other. KEY POINTS: • Both machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and quantitative perfusion cardiac MR performed well in the detection of hemodynamically significant stenosis. • Compared with stress myocardial blood flow (MBF) from quantitative perfusion cardiac MR, myocardial perfusion reserve (MPR) provided higher diagnostic performance for detecting hemodynamically significant coronary artery stenosis. • ML-based CT-FFR and MPR from quantitative cardiac MR perfusion yielded similar diagnostic performance in assessing vessel-specific hemodynamically significant stenosis, whereas MPR had a favorable performance in per-patient analysis.

9.
Eur Radiol ; 34(8): 4939-4949, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38214735

ABSTRACT

OBJECTIVES: To validate a novel stepwise strategy in which computed tomography-derived fractional flow reserve (FFRCT) is restricted to intermediate stenosis on coronary computed tomography angiography (CCTA) and computed tomography myocardial perfusion imaging (CT-MPI) was reserved for vessels with gray zone FFRCT values. MATERIALS AND METHODS: This retrospective study included 87 consecutive patients (age, 58 ± 10 years; 70% male) who underwent CCTA, dynamic CT-MPI, interventional coronary angiography (ICA), and fractional flow reserve (FFR) for suspected or known coronary artery disease. FFRCT was computed using a deep learning-based platform. Three stepwise strategies (CCTA + FFRCT + CT-MPI, CCTA + FFRCT, CCTA + CT-MPI) were constructed and their diagnostic performance was evaluated using ICA/FFR as the reference standard. The proportions of vessels requiring further ICA/FFR measurement based on different strategies were noted. Furthermore, the net reclassification index (NRI) was calculated to ascertain the superior model. RESULTS: The CCTA + FFRCT + CT-MPI strategy yielded the lowest proportion of vessels requiring additional ICA/FFR measurement when compared to the CCTA + FFRCT and CCTA + CT-MPI strategies (12%, 22%, and 24%). The CCTA + FFRCT + CT-MPI strategy exhibited the highest accuracy for ruling-out (91%, 84%, and 85%) and ruling-in (90%, 85%, and 85%) functionally significant lesions. All strategies exhibited comparable sensitivity for ruling-out functionally significant lesions and specificity for ruling-in functionally significant lesions (p > 0.05). The NRI indicated that the CCTA + FFRCT + CT-MPI strategy outperformed the CCTA + FFRCT strategy (NRI = 0.238, p < 0.001) and the CCTA + CT-MPI strategy (NRI = 0.233%, p < 0.001). CONCLUSIONS: The CCTA + FFRCT + CT-MPI stepwise strategy was superior to the CCTA + FFRCT strategy and CCTA+ CT-MPI strategy by minimizing unnecessary invasive diagnostic catheterization without compromising the agreement rate with ICA/FFR. CLINICAL RELEVANCE STATEMENT: Our novel stepwise strategy facilitates greater confidence and accuracy when clinicians need to decide on interventional coronary angiography referral or deferral, reducing the burden of invasive investigations on patients. KEY POINTS: • A stepwise CCTA + FFRCT + CT-MPI strategy holds promise as a viable method to reduce the need for invasive diagnostic catheterization, while maintaining a high level of agreement with ICA/FFR. • The CCTA + FFRCT + CT-MPI strategy performed better than the CCTA + FFRCT and CCTA + CT-MPI strategies. • A stepwise CCTA + FFRCT + CT-MPI strategy allows to minimize unnecessary invasive diagnostic catheterization and helps clinicians to referral or deferral for ICA/FFR with more confidence.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Artery Disease , Deep Learning , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Humans , Male , Female , Middle Aged , Fractional Flow Reserve, Myocardial/physiology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Retrospective Studies , Myocardial Perfusion Imaging/methods , Computed Tomography Angiography/methods , Coronary Angiography/methods , Aged
10.
J Nucl Cardiol ; 36: 101850, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38518887

ABSTRACT

Myocardial perfusion imaging (MPI) is a powerful tool for the functional assessment of ischemia in patients with suspected or known coronary artery disease (CAD). Given that the diagnostic accuracy and prognostic value of MPI and post-test management are highly dependent on achieving an adequate stress vasodilatory response, it is critical to identify those who may not have adequately responded to vasodilator pharmacological stress agents such as adenosine, dipyridamole, and regadenoson. Caffeine, a potent inhibitor of the adenosine receptor, is a compound that can affect vasodilatory hemodynamics, result in false negative studies, and potentially alter management in cases of inaccurate test results. Vasodilator non-responsiveness can be suspected by examining hemodynamics, quantitative positron emission tomography (PET) metrics such as myocardial flow reserve (MFR), and splenic response to stress. Quantitative MFR values of 1-1.2 should raise suspicion for nonresponsiveness in the setting of normal perfusion, along with the absence of a splenic switch off. Newer metrics, such as splenic response ratio, can be used to aid in the identification of potential nonresponders to pharmacologic vasodilators.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Vasodilator Agents , Humans , Myocardial Perfusion Imaging/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Exercise Test , Positron-Emission Tomography/methods , Dipyridamole/pharmacology , Coronary Circulation/drug effects , Adenosine , Purines , Pyrazoles
11.
J Nucl Cardiol ; 31: 101778, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38237364

ABSTRACT

BACKGROUND: Since typical angina has become less frequent, it is unclear if this symptom still has prognostic significance. METHODS: We evaluated 38,383 patients undergoing stress/rest SPECT myocardial perfusion imaging followed for a median of 10.9 years. After dividing patients by clinical symptoms, we evaluated the magnitude of myocardial ischemia and subsequent mortality among medically treated versus revascularized subgroups following testing. RESULTS: Patients with typical angina had more frequent and greater ischemia than other symptom groups, but not higher mortality. Among typical angina patients, those who underwent early revascularization had substantially greater ischemia than the medically treated subgroup, including a far higher proportion with severe ischemia (44.9% vs 4.3%, P < 0.001) and transient ischemic dilation of the LV (31.3% vs 4.7%, P < 0.001). Nevertheless, the revascularized typical angina subgroup had a lower adjusted mortality risk than the medically treated subgroup (HR = 0.72, 95% CI: 0.57-0.92, P = 0.009) CONCLUSIONS: Typical angina is associated with substantially more ischemia than other clinical symptoms. However, the high referral of patients with typical angina patients with ischemia to early revascularization resulted in this group having a lower rather than higher mortality risk versus other symptom groups. These findings illustrate the need to account for "treatment bias" among prognostic studies.


Subject(s)
Coronary Artery Disease , Myocardial Ischemia , Humans , Prognosis , Angina Pectoris/diagnostic imaging , Angina Pectoris/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Ischemia
12.
J Nucl Cardiol ; : 101817, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38301802

ABSTRACT

Diaphragmatic eventration is the elevation of hemi-diaphragm without any disruption to diaphragmatic continuity which can be congenital or acquired. The most common acquired cause is phrenic nerve paralysis due to traumatic causes and is usually incidentally diagnosed on chest radiograph or computed tomography. We hereby report a case of a patient who had road traffic accident with fracture of the left proximal femur. Stress Myocardial Perfusion Imaging (MPI) done for pre-operative clearance showed an incidental tracer avidity adjoining to left myocardium in the thorax. It was confirmed on anatomical imaging to be gastric cavity uptake due to diaphragm eventration.

13.
J Nucl Cardiol ; 31: 101779, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38215598

ABSTRACT

OBJECTIVES: The objective of this study was to determine the diagnostic performance of 15O-water positron emission tomography (PET) myocardial perfusion imaging to detect coronary artery disease (CAD) using the truth-standard of invasive coronary angiography (ICA) with fractional flow reserve (FFR) or instantaneous wave-Free Ratio (iFR) or coronary computed tomography angiogram (CCTA). BACKGROUND: 15O-water has a very high first-pass extraction that allows accurate quantification of myocardial blood flow and detection of flow-limiting CAD. However, the need for an on-site cyclotron and lack of automated production at the point of care and relatively complex image analysis protocol has limited its clinical use to date. METHODS: The RAPID WATER FLOW study is an open-label, multicenter, prospective investigation of the accuracy of 15O-water PET to detect obstructive angiographic and physiologically significant stenosis in patients with suspected CAD. The study will include the use of an automated system for producing, dosing, and injecting 15O-water and enrolling approximately 215 individuals with suspected CAD at approximately 10 study sites in North America and Europe. The primary endpoint of the study is the diagnostic sensitivity and specificity of the 15O-water PET study using the truth-standard of ICA with FFR or iFR to determine flow-limiting stenosis, or CCTA to rule out CAD and incorporating a quantitative analytic platform developed for the 15O-water PET acquisitions. Sensitivity and specificity are to be considered positive if the lower bound of the 95% confidence interval is superior to the threshold of 60% for both, consistent with prior registration studies. Subgroup analyses include assessments of diagnostic sensitivity, specificity, and accuracy in female, obese, and diabetic individuals, as well as in those with multivessel disease. All enrolled individuals will be followed for adverse and serious adverse events for up to 32 hours after the index PET scan. The study will have >90% power (one-sided test, α = 0.025) to test the hypothesis that sensitivity and specificity of 15O-water PET are both >60%. CONCLUSIONS: The RAPID WATER FLOW study is a prospective, multicenter study to determine the diagnostic sensitivity and specificity of 15O-water PET as compared to ICA with FFR/iFR or CCTA. This study will introduce several novel aspects to imaging registration studies, including a more relevant truth standard incorporating invasive physiologic indexes, coronary CTA to qualify normal individuals for eligibility, and a more quantitative approach to image analysis than has been done in prior pivotal studies. CLINICAL TRIAL REGISTRATION INFORMATION: Clinical-Trials.gov (#NCT05134012).


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Myocardial Perfusion Imaging , Humans , Female , Prospective Studies , Fractional Flow Reserve, Myocardial/physiology , Constriction, Pathologic , Water , Coronary Angiography/methods , Perfusion , Predictive Value of Tests , Myocardial Perfusion Imaging/methods , Computed Tomography Angiography/methods
14.
J Nucl Cardiol ; : 101908, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38996910

ABSTRACT

BACKGROUND: The epidemiology of coronary artery disease (CAD) has shifted, with increasing prevalence of cardiometabolic disease and decreasing findings of obstructive CAD on myocardial perfusion imaging (MPI). Coronary microvascular dysfunction (CMD), defined as impaired myocardial flow reserve (MFR) by positron emission tomography (PET), has emerged as a key mediator of risk. We aimed to assess whether PET MFR provides additive value for risk stratification of cardiometabolic disease patients compared with single-photon emission computed tomography (SPECT) MPI. METHODS: We retrospectively followed patients referred for PET, exercise SPECT, or pharmacologic SPECT MPI with cardiometabolic disease (obesity, diabetes, or chronic kidney disease) and without known CAD. We compared rates and hazards of composite MACE (annualized cardiac mortality or acute myocardial infarction) among propensity-matched PET and SPECT patients using Poisson and Cox regression. Normal SPECT was defined as a total perfusion deficit (TPD) <5% reflecting the absence of obstructive CAD. Normal PET was defined as TPD <5% plus MFR ≥2.0. RESULTS: Among 21,544 patients referred from 2006-2020, cardiometabolic disease was highly prevalent (PET: 2308 [67%], SPECT: 9984 [55%]) and higher among patients referred to PET (p <0.001). Obstructive CAD findings (TPD >5%) were uncommon (PET: 21% and SPECT 11%). Conversely, impaired MFR on PET (<2.0) was common (62%). In propensity-matched analysis over a median 6.4-year follow-up, normal PET identified low-risk (0.9%/year MACE) patients, and abnormal PET identified high-risk (4.2%/year MACE) patients with cardiometabolic disease; conversely, those with normal pharmacologic SPECT remained moderate-risk (1.6%/year, p<0.001 compared to normal PET). CONCLUSIONS: Cardiometabolic disease is common among patients referred for MPI and is associated with heterogenous level of risk. Compared with pharmacologic SPECT, PET with MFR can detect nonobstructive CAD including CMD and can more accurately discriminate low-risk from higher-risk individuals.

15.
J Nucl Cardiol ; 37: 101881, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38723886

ABSTRACT

OBJECTIVES: We sought to develop a novel deep learning (DL) workflow to interpret single-photon emission computed tomography (SPECT) wall motion. BACKGROUND: Wall motion assessment with SPECT is limited by image temporal and spatial resolution. Visual interpretation of wall motion can be subjective and prone to error. Artificial intelligence (AI) may improve accuracy of wall motion assessment. METHODS: A total of 1038 patients undergoing rest electrocardiogram (ECG)-gated SPECT and echocardiography were included. Using echocardiography as truth, a DL-model (DL-model 1) was trained to predict the probability of abnormal wall motion. Of the 1038 patients, 317 were used to train a DL-model (DL-model 2) to assess regional wall motion. A 10-fold cross-validation was adopted. Diagnostic performance of DL was compared with human readers and quantitative parameters. RESULTS: The area under the receiver operating characteristic curve (AUC) and accuracy (ACC) of DL model (AUC: .82 [95% CI: .79-.85]; ACC: .88) were higher than human (AUC: .77 [95% CI: .73-.81]; ACC: .82; P < .001) and quantitative parameter (AUC: .74 [95% CI: .66-.81]; ACC: .78; P < .05). The net reclassification index (NRI) was 7.7%. The AUC and accuracy of DL model for per-segment and per-vessel territory diagnosis were also higher than human reader. The DL model generated results within 30 seconds with operable guided user interface (GUI) and therefore could provide preliminary interpretation. CONCLUSIONS: DL can be used to improve interpretation of rest SPECT wall motion as compared with current human readers and quantitative parameter diagnosis.


Subject(s)
Deep Learning , Tomography, Emission-Computed, Single-Photon , Humans , Male , Female , Middle Aged , Aged , Tomography, Emission-Computed, Single-Photon/methods , Echocardiography/methods , ROC Curve , Reproducibility of Results , Electrocardiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology
16.
J Nucl Cardiol ; 32: 101811, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38244976

ABSTRACT

BACKGROUND: There is currently little information regarding the usage and comparative predictors of mortality among patients referred for single-photon emission computed tomography (SPECT) versus positron emission tomography (PET) myocardial perfusion imaging (MPI) within multimodality imaging laboratories. METHODS: We compared the clinical characteristics and mortality outcomes among 15,718 patients referred for SPECT-MPI and 6202 patients referred for PET-MPI between 2008 and 2017. RESULTS: Approximately two-thirds of MPI studies were performed using SPECT-MPI. The PET-MPI group was substantially older and included more patients with known coronary artery disease (CAD), hypertension, diabetes, and myocardial ischemia. The annualized mortality rate was also higher in the PET-MPI group, and this difference persisted after propensity matching 3615 SPECT-MPI and 3615 PET-MPI patients to have similar clinical profiles. Among the SPECT-MPI patients, the most potent predictor of mortality was exercise ability and performance, including consideration of patients' mode of stress testing and exercise duration. Among the PET-MPI patients, myocardial flow reserve (MFR) was the most potent predictor of mortality. CONCLUSIONS: In our real-world setting, PET-MPI was more commonly employed among older patients with more cardiac risk factors than SPECT-MPI patients. The most potent predictors of mortality in our SPECT and PET-MPI groups were variables exclusive to each test: exercise ability/capacity for SPECT-MPI patients and MFR for PET-MPI patients.


Subject(s)
Coronary Artery Disease , Myocardial Perfusion Imaging , Humans , Positron-Emission Tomography , Tomography, Emission-Computed, Single-Photon , Coronary Artery Disease/diagnostic imaging , Exercise
17.
J Nucl Cardiol ; : 101868, 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38685397

ABSTRACT

BACKGROUND: Evaluation of sufficient adenosine response constitutes a significant challenge in myocardial perfusion imaging (MPI). Splenic switch-off in MPI studies denotes a visually (qualitatively) reduced splenic radiotracer signal during adenosine stress and is considered indicative of sufficient cardiac vasodilation. In this study, we examined semi-quantitative and quantitative approaches to splenic switch-off assessment using [15O]H2O-PET with either summed activity images or calculated parametric splenic blood flow images. METHODS: Cohort 1: 90 clinical patients undergoing [15O]H2O MPI in whom adenosine response was considered clinically adequate were identified to characterize the corresponding splenic switch-off. Spleen stress/rest-ratio (SSR-ratio) was calculated as spleen stress signal intensity/spleen rest signal intensity on both summed activity and parametric blood flow images. Cohort 2: Twenty-five patients with repeat MPI due to suspected insufficient adenosine response were identified to observe if splenic switch-off on the initial MPI could predict the outcome of the repeat MPI. Cohort 3: Fifty-four patients who were considered adenosine responders on MPI and who had a coronary angiogram (CAG) follow-up within 3 months after MPI served as a separate validation group. RESULTS: Splenic switch-off was present in most patients with a clinically sufficient adenosine response (Cohort 1), illustrated by both visual (74.4%-86.7%), semi-quantitative (summed activity images) (85.6%), and quantitative (parametric blood flow images) (92.2%) evaluation, which corresponds to the distribution in patients with sufficient adenosine response and follow-up CAG (Cohort 3). In patients suspected of insufficient adenosine response on the initial MPI (Cohort 2), the repeat MPI only yielded different myocardial blood flow (MBF) results if the initial SSR-ratio was >0.90 on splenic parametric blood flow images. CONCLUSION: quantitative splenic switch-off assessment on parametric blood flow images was superior to the semi-quantitative splenic switch-off approach. Patients with a suspected insufficient initial adenosine response and SSR-ratio >0.90 can benefit from a repeat MPI. Thus, the integration of quantitative splenic switch-off using parametric blood flow images in the evaluation of adenosine response may support future clinical decision-making.

18.
J Nucl Cardiol ; 32: 101797, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38185409

ABSTRACT

BACKGROUND: Quantification of myocardial blood flow (MBF) is used for the noninvasive diagnosis of patients with coronary artery disease (CAD). This study compared traditional statistics, machine learning, and deep learning techniques in their ability to diagnose disease using only the rest and stress MBF values. METHODS: This study included 3245 rest and stress rubidium-82 positron emission tomography (PET) studies and matching diagnostic labels from perfusion reports. Standard logistic regression, lasso logistic regression, support vector machine, random forest, multilayer perceptron, and dense U-Net were compared for per-patient detection and per-vessel localization of scars and ischemia. RESULTS: Receiver-operator characteristic area under the curve (AUC) of machine learning models was significantly higher than those of traditional statistics models for per-patient detection of disease (0.92-0.95 vs. 0.87) but not for per-vessel localization of ischemia or scar. Random forest showed the highest AUC = 0.95 among the different models compared. On the final hold-out set for generalizability, random forest showed an AUC of 0.92 for detection and 0.89 for localization of perfusion abnormalities. CONCLUSIONS: For per-vessel localization, simple models trained on segmental data performed similarly to a convolutional neural network trained on polar-map data, highlighting the need to justify the use of complex predictive algorithms through comparison with simpler methods.


Subject(s)
Cicatrix , Deep Learning , Humans , Cicatrix/diagnostic imaging , Tomography, X-Ray Computed , Ischemia , Positron-Emission Tomography
19.
J Nucl Cardiol ; 37: 101880, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38710439

ABSTRACT

BACKGROUND: It remains unknown whether estimation of the relative stress perfusion deficit offers added value in the prediction of significant coronary artery stenosis in myocardial perfusion imaging with [15O]H2O positron emission tomography (PET) in a population with high prevalence of established cardiac disease. METHODS: During eight months, we consecutively included all patients undergoing [15O]H2O PET and subsequent invasive coronary angiography (ICA). Significant stenosis was defined from ICA as fractional flow reserve ≤.8 or coronary artery narrowing of ≥70%. We calculated absolute and relative total perfusion deficits (aTPD and rTPD, respectively) as semiquantitative measures of the extent and severity of reduced stress perfusion. A multivariate logistic regression analysis was performed to test the adjusted associations (odds ratio (OR) with 95% CI) with significant coronary artery stenosis. RESULTS: Of 800 patients undergoing [15O]H2O PET, 144 underwent ICA, where 142 patients had aTPD of ≥3% and 79 (55%) of these had at least one significant stenosis. In an adjusted analysis, rTPD (OR10% increase = 2.12 (1.44-3.12), P < .001), previous coronary artery bypass grafting (CABG) (OR = .11 (.03-.36), P < .001) and reduced left ventricular ejection fraction (LVEF) (OR = .25 (.08-.84), P = .02) were independently associated with significant stenosis, whereas the association with aTPD (OR10% increase = 1.14 (.98-1.32), P = .08) was modest. CONCLUSIONS: In the presence of an absolute perfusion deficit (aTPD of ≥3%), rTPD may improve the prediction of significant stenosis in a heterogeneous population of patients examined with [15O]H2O PET. Furthermore, previous CABG and reduced LVEF are associated with nonstenotic perfusion deficiencies, suggesting caution when interpreting myocardial perfusion imaging in such patients.


Subject(s)
Coronary Stenosis , Myocardial Perfusion Imaging , Oxygen Radioisotopes , Positron-Emission Tomography , Humans , Male , Female , Middle Aged , Aged , Positron-Emission Tomography/methods , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/physiopathology , Coronary Angiography , Exercise Test
20.
BMC Med Imaging ; 24(1): 40, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38347469

ABSTRACT

PURPOSE: Both of extracellular extravascular volume (EEV) and extracellular volume fraction (ECV) were proposed to quantify enlargement of myocardial interstitial space due to myocardium loss or fibrosis. The study aimed to investigate the feasibility of using EEV derived from myocardial computed tomography (CT) perfusion imaging (VPCT) and extracellular volume quantification with single-energy subtraction CT (ECV- SECT) for quantifying myocardial fibrosis. METHODS: In this study, 17 patients with suspected and known coronary artery disease underwent examination using a dual-source CT scanner. The EEV- VPCT was derived from dynamic whole-heart myocardial perfusion imaging, and the ECV_SECT was calculated from late-enhanced images 5 min after bolus contrast injection by subtracting the noncontrast baseline. The late gadolinium enhancement (LGE) on cardiac magnetic resonance (CMR) imaging was used as a reference. RESULTS: In total, 11 patients and 73 segments exhibited positivity for LGE on CMR imaging. These were classified into three groups according to the segments: fibrotic segments (group I, n = 73), nonfibrotic segments in LGE-positive patients (group II, n = 103), and segments in LGE-negative patients (group III, n = 80). ECV- SECT, EEV- VPCT, myocardial blood flow (MBF), and myocardial blood volume (MBV) significantly differed among these groups (all P < 0.05). ECV- SECT was significantly higher and EEV- VPCT, MBF, and MBV were significantly lower in fibrotic myocardial segments than in nonfibrotic ones (all P < 0.01). ECV- SECT and EEV- VPCT independently affected myocardial fibrosis. There was no significant correlation between ECV- SECT and EEV- VPCT. The capability of EEV- VPCT to diagnose myocardial fibrosis was equivalent to that of ECV- SECT (area under the curve: 0.798 vs. 0.806, P = 0.844). ECV- SECT of > 41.2% and EEV- VPCT of < 10.3% indicated myocardial fibrosis. CONCLUSIONS: EEV- VPCT is actually first-pass distribution volume that can feasibly be used to quantify myocardial fibrosis. Furthermore, the diagnostic efficacy of EEV- VPCT is comparable to that of ECV- SECT.


Subject(s)
Cardiomyopathies , Myocardial Perfusion Imaging , Humans , Contrast Media , Myocardial Perfusion Imaging/methods , Gadolinium , Myocardium/pathology , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Fibrosis , Predictive Value of Tests , Magnetic Resonance Imaging, Cine/methods
SELECTION OF CITATIONS
SEARCH DETAIL