Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Hand Surg Am ; 48(3): 314.e1-314.e7, 2023 03.
Article in English | MEDLINE | ID: mdl-34955320

ABSTRACT

PURPOSE: The purpose of this study was to investigate the impact of repairing a zone II flexor digitorum profundus (FDP) laceration anatomically versus extra-anatomically on tendon loads and work of flexion (WOF). METHODS: Twenty digits from 5 cadaveric specimens were tested using an in vitro active finger motion simulator under 2 FDP tendon repair conditions: anatomic and extra-anatomic. Tensile loads in FDP and flexor digitorum superficialis (FDS), WOF, and total active finger range of motion (ROM) were measured using in-line load cells and electromagnetic tracking, respectively. RESULTS: The anatomic repairs had no effect on tendon loads or WOF for either FDP or FDS. The extra-anatomic repairs increased FDP loads by 32% and decreased FDS loads by 9% compared with those in the intact condition. This pattern was similar for WOF following extra-anatomic repairs, which increased FDP WOF by 31% and decreased FDS WOF by 18%. Comparing the 2 repairs, FDP loads and WOF were 25% and 22% greater, respectively, with extra-anatomic repairs compared with anatomic repairs, with no significant change in FDS. Total active ROM was not affected by either repair. CONCLUSIONS: In this in vitro cadaveric model, extra-anatomic repairs of FDP increased tendon loads and WOF compared with anatomic repairs. CLINICAL RELEVANCE: On the basis of this study, reconstitution of the anatomic relationship of FDP and FDS at the Camper chiasm during the repair of zone II flexor tendon lacerations is recommended.


Subject(s)
Lacerations , Tendons , Humans , Biomechanical Phenomena , Tendons/surgery , Fingers/surgery , Lacerations/surgery , Cadaver
2.
J Hand Surg Am ; 2022 Oct 25.
Article in English | MEDLINE | ID: mdl-36307286

ABSTRACT

PURPOSE: The purpose of the study was to evaluate joint kinematics and tendon work of flexion (WOF) following a flexor digitorum profundus (FDP)-to-volar plate (VP) repair technique relative to a pullout button for zone I flexor tendon injuries. METHODS: Fourteen digits were tested using an in vitro active finger motion simulator under 3 repaired conditions following a simulated zone I avulsion: button, FDP-VP, and "no slack" FDP-VP (corrected for additional VP length). Outcome metrics included active joint range of motion (ROM), fingertip strength, FDP and flexor digitorum superficialis tensile loads, and WOF. RESULTS: The button and FDP-VP techniques restored WOF to the intact condition for FDP and flexor digitorum superficialis. All repairs restored distal interphalangeal joint ROM and kinematics to the intact condition. Similarly, all repairs restored WOF; however, the "no slack" FDP-VP significantly increased WOF by 10% to 12% over the simple FDP-VP repair. The button technique had similar fingertip strength to the intact condition, whereas the FDP-VP repairs significantly reduced peak fingertip strength from intact, albeit only 1-2 N compared with the button repair. CONCLUSION: In this in vitro cadaveric model, the button and FDP-VP techniques restored WOF and ROM to within intact levels, with no difference between these repairs in all measured outcome metrics. CLINICAL RELEVANCE: Based on its initial strength and its equal biomechanical performance compared with the button repair, the FDP-VP technique may be a viable option for treating FDP avulsions.

3.
J Shoulder Elbow Surg ; 31(6): 1294-1299, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35051540

ABSTRACT

INTRODUCTION: The purpose of this study was to determine the effect of biceps tendon tenotomy on the load of the supraspinatus tendon/muscle complex during abduction of the arm from 0° to 15°. METHODS: Eleven fresh frozen human cadaver shoulders (6 males, 5 females, age ranged 44-88 years, mean upper extremity weight 2.96 ± 0.56 kg) were included. The specimens were sequentially mounted onto a custom-made fixture attached to a pulley system and load cell. The pulley system was used to pull the supraspinatus tendon/muscle complex along its fiber directions to abduct the arm to 15°. Abduction angles were recorded with a digital inclinometer. Two conditions were tested: (1) long head biceps tendon (LHBT) intact and in normal anatomical position; (2) LHBT cut within the bicipital groove. Qualitative visual inspection of humeral head displacement during abduction was also included. Descriptive statistics were calculated. The Shapiro-Wilk test was used to establish normal data distribution, and the paired t-test was used to compare the 2 conditions. RESULTS: For the intact condition (LHBT intact), the mean load was 45.71 ± 21.04 N. For the biceps tenotomy test, the load measured 41.37 ± 23.43 N. These differences were not significant (P = .1480). In the tenotomy condition, the humeral head initially displaced inferior, and with initiation of abduction, the humeral head translated superior to its normal position. CONCLUSION: The results suggest that the LHBT has no critical role with initial abduction of the arm. Furthermore, the LHBT does not appear to increase loads required for the supraspinatus muscle/tendon complex to perform the same action of abduction.


Subject(s)
Shoulder Joint , Shoulder , Adult , Aged , Aged, 80 and over , Arm , Biomechanical Phenomena , Cadaver , Female , Humans , Humeral Head/surgery , Male , Middle Aged , Range of Motion, Articular/physiology , Rotator Cuff , Shoulder Joint/surgery , Tenotomy
4.
J Biomech ; 173: 112254, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39098262

ABSTRACT

Accurately estimating in vivo tendon load non-invasively remains a major challenge in biomechanics, which might be overcome by shear-wave tensiometry. Shear-wave tensiometry measures the speed of mechanically induced tendon shear waves by skin-mounted accelerometers. To gauge the feasibility and accuracy of this novel technique, we obtained patellar tendon shear wave speeds via shear-wave tensiometry during sustained or ramp voluntary contractions of the knee extensors in two experiments (n = 8 in both). In experiment one, participants produced a constant knee extension torque of âˆ¼ 50 Nm at five different knee joint angles (i.e. variable tendon load), which resulted in estimated patellar tendon forces between 1005 ± 6N and 1182 ± 16 N. However, wave speed squared did not correlate with estimated tendon force within participants (rrm(31) = -0.19, p = 0.278). In experiment two, averaged correlation coefficients between normalized wave speed squared and torque of maximal and submaximal voluntary contractions across participants ranged between r = 0.43 and r = 0.94, while the time-varying correlation between these normalized signals ranged from r = -0.99 to r = 1.00. Further, the mean absolute errors (MAEs) between normalized wave speed squared and normalized torque across participants ranged between 0.03 and 0.54, which were larger than the MAEs between normalized torque and normalized summed EMG amplitude from the superficial quadriceps muscles (0.03-0.54 versus 0.06-0.26, respectively). In conclusion, there was no simple relation between shear wave speed squared and patellar tendon load, which severely limits the feasibility of shear-wave tensiometry for accurately estimating in vivo tendon load at the knee joint.


Subject(s)
Patellar Ligament , Torque , Humans , Patellar Ligament/physiology , Male , Adult , Biomechanical Phenomena , Female , Knee Joint/physiology , Muscle Contraction/physiology , Young Adult
5.
J Biomech ; 106: 109799, 2020 06 09.
Article in English | MEDLINE | ID: mdl-32517985

ABSTRACT

It has been shown that shear wave speed is directly dependent on axial stress in ex vivo tendons. Hence, a wave speed sensor could be used to track tendon loading during movement. However, adjacent soft tissues and varying joint postures may affect the wave speed-load relationship for intact tendons. The purpose of this study was to determine whether the proportional relationship between squared wave speed and stress holds for in situ cadaveric Achilles tendons, to evaluate whether this relationship is affected by joint angle, and to assess potential calibration techniques. Achilles tendon wave speed and loading were simultaneously measured during cadaveric simulations of gait and isometric contractions performed in a robotic gait simulator. Squared wave speed and axial stress were highly correlated during isometric contraction at all ankle postures (R2avg = 0.98) and during simulations of gait (R2avg = 0.92). Ankle plantarflexion angle did not have a consistent effect on the constant of proportionality (p = 0.217), but there was a significant specimen-angle interaction effect (p < 0.001). Wave speed-based predictions of tendon stress were most accurate (average RMS error = 11% of maximum stress) when calibrating to isometric contractions performed in a dorsiflexed posture that resembled the posture at peak Achilles loading during gait. The results presented here show that the linear relationship between tendon stress and squared shear wave speed holds for a case resembling in vivo conditions, and that calibration during an isometric task can yield accurate predictions of tendon loading during a functional task.


Subject(s)
Achilles Tendon , Isometric Contraction , Ankle Joint , Biomechanical Phenomena , Cadaver , Calibration , Gait , Humans
6.
Clin Biomech (Bristol, Avon) ; 29(4): 395-9, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24636307

ABSTRACT

BACKGROUND: Recreational runners frequently suffer from chronic pathologies. The knee and ankle have been highlighted as common injury sites. Barefoot and barefoot inspired footwear have been cited as treatment modalities for running injuries as opposed to more conventional running shoes. This investigation examined knee and ankle loading in barefoot and barefoot inspired footwear in relation to conventional running shoes. METHOD: Thirty recreational male runners underwent 3D running analysis at 4.0m·s(-1). Joint moments, patellofemoral contact force and pressure and Achilles tendon forces were compared between footwear. FINDINGS: At the knee the results show that barefoot and barefoot inspired footwear were associated with significant reductions in patellofemoral kinetic parameters. The ankle kinetics indicate that barefoot and barefoot inspired footwear were associated with significant increases in Achilles tendon force compared to conventional shoes. INTERPRETATION: Barefoot and barefoot inspired footwear may serve to reduce the incidence of knee injuries in runners although corresponding increases in Achilles tendon loading may induce an injury risk at this tendon.


Subject(s)
Achilles Tendon/physiology , Ankle/physiology , Knee/physiology , Running/physiology , Shoes/classification , Weight-Bearing/physiology , Adult , Equipment Design , Humans , Knee Injuries/prevention & control , Male , Pressure , Protective Clothing , Running/injuries
SELECTION OF CITATIONS
SEARCH DETAIL