ABSTRACT
A 48-year-old man developed general fatigue, dyspnea, and fever at an altitude of 1562 m from the morning of the first day of a 3-day hike. Despite pharyngeal discomfort and mild general fatigue, he felt that the symptoms were not sufficient to abandon his plan. He usually required 1.5 hours to reach Tokusawa (6.4 km from the starting point at an altitude of 1500 m), but this time he required 2.5 hours and slept briefly upon arrival at Tokusawa due to extreme fatigue and respiratory discomfort. His symptoms became aggravated, so he presented at a mountain clinic with oxygen saturation at 80% and body temperature of 37.6ºC. He was diagnosed with hypoxemia due to pneumonia and/or other disease(s) and was evacuated to a hospital where a chest computed tomography scan revealed ground glass opacity and infiltrative shadows. He was treated for pneumonia, but another doctor discovered during follow-up that the patient had sprayed 300 mL of a waterproofing aerosol on mountain equipment in a nonventilated, enclosed area of his home on the night before starting out on the hike. Therefore, waterproofing spray was considered to have caused pulmonary damage. Self-reporting or appropriate questionnaires are the only means of identifying this type of injury. The differential diagnosis of pulmonary problems in an outdoor setting should include toxic aerosol exposure from waterproofing spray.
Subject(s)
Lung Injury/diagnosis , Recreation , Aerosols , Diagnosis, Differential , Humans , Japan , Lung Injury/diagnostic imaging , Lung Injury/etiology , Male , Middle AgedABSTRACT
Waterproofing spray-associated lung injury (WALI) is an acute respiratory disorder characterized by bilateral diffuse lung injury on chest computed tomography (CT). In most cases, the symptoms and abnormal radiographic findings of WALI patients improve spontaneously over several days; however, some cases have persistent symptoms and abnormal shadows for >1 week. The distinctive features of each WALI are unknown. Herein, we present two new cases of WALI that we encountered in our hospital, and we previously reported two other cases of WALI. We examined the characteristics of WALI in our cases and 39 other cases of WALI definitively diagnosed and reported in PubMed and the Japan medical board with verifiable data during a 15-year period. We compared the clinical characteristics of the 22 cases in which the patients' symptoms were resolved within 1 week (early improvement) to those of the 21 cases in which the symptoms were resolved after >1 week (delayed improvement). The WALI cases with delayed improvement had significantly more shadowing that extended over the entire lung field and was not biased in intensity toward the upper or lower lung field. In addition, the serum white blood cell (WBC) counts and serum Krebs von den Lungen-6 (KL-6) levels differed significantly between the cases of early and delayed improvement of WALI.
ABSTRACT
Background: Acute respiratory distress syndrome (ARDS) is a serious respiratory disease, caused by severe infection, trauma, shock, inhalation of harmful gases and poisons and presented with acute-onset and high mortality. Timely and accurate identification will be helpful to the treatment and prognosis of ARDS cases. Herein, we report a case of ARDS caused by occupational exposure to waterproofing spray. To our knowledge, inhalation of waterproofing spray is an uncommon cause of ARDS, and what makes our case special is that we ruled out concurrent infections with some pathogens by using metagenomic next-generation sequencing (mNGS) as an auxiliary diagnosis, which presents the most comprehensive etiological examination of similar reports. Case Presentation: A previously healthy 25 years old delivery man developed hyperpyrexia, chest tightness, cough and expectoration. The symptoms occurred and gradually exacerbated after exposure to a waterproofing spray. The chest computed tomography (CT) finding showed diffuse ground glass and infiltrative shadows in both lungs. The diagnosis of ARDS related to waterproofing spray was established on the basis of comprehensive differential diagnosis and etiological examination. The patient achieved good curative effect after proper systemic glucocorticoid therapy. Conclusions: The diagnosis and differential diagnosis of acute respiratory failure for outdoor workers, such as delivery drivers or hikers, should be considered whether toxic aerosol exposure exists from daily contacts. The case can educate the public that more attention should be paid to avoid exposure to these chemicals by aerosols/ingestion mode and some preventive strategies should be taken in occupational environment. The treatment effect of glucocorticoids is significant in ARDS patients with general chemical damage caused by inhaling toxic gases and substances.
Subject(s)
Occupational Exposure , Respiratory Distress Syndrome , Adult , Aerosols/toxicity , Gases , Humans , Inhalation Exposure , Male , Occupational Exposure/adverse effects , Respiratory Distress Syndrome/chemically inducedABSTRACT
An 82-year-old Japanese man with idiopathic pulmonary fibrosis (IPF) experienced dyspnea after using a waterproofing spray in a closed room. He presented with hypoxemia and his chest computed tomography showed additive bilateral diffuse ground-glass attenuation on fibrosis, which was diagnostic of an acute exacerbation of IPF (AE-IPF). Combined treatment with high-dose corticosteroids and immunosuppressants were ineffective, and he later died of respiratory failure. Autopsy findings showed diffuse alveolar damage with honeycombing. His medical history and autopsy histopathology suggested AE-IPF caused by the inhalation of a waterproofing spray.
Subject(s)
Idiopathic Pulmonary Fibrosis , Lung Diseases , Aged, 80 and over , Autopsy , Dyspnea , Humans , Idiopathic Pulmonary Fibrosis/drug therapy , Male , Tomography, X-Ray ComputedABSTRACT
A 30-year-old man developed chills, cough and dyspnea a few minutes after using a fluoropolymer-based waterproofing spray in a small closed room. He visited our hospital 1 h later. Examination revealed that the patient had incessant cough, tachypnea, fever and decreased peripheral arterial oxygen saturation. Blood tests revealed leukocytosis with elevated serum C-reactive protein levels. Chest radiographs and computed tomography (CT) scan showed bilateral ground glass opacities, mainly in the upper lobes. Bronchoalveolar lavage (BAL) fluid obtained from the right middle lobe showed a bloody appearance. Microscopic examination of a BAL cytospin specimen revealed the presence of numerous red blood cells associated with extreme neutrophilia. Microbiological studies of the BAL fluid were negative. The patient was observed without corticosteroid therapy, and his symptoms and abnormal shadows on the chest radiographs and CT improved. On day 7 after admission, the patient was discharged from the hospital. Accidental inhalation of waterproofing spray may cause diffuse alveolar hemorrhage, a rare manifestation of acute lung injury. Supportive treatment may be effective and sufficient.