Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 181
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Dig Dis Sci ; 66(4): 983-987, 2021 04.
Article in English | MEDLINE | ID: mdl-33428037

ABSTRACT

Removal of foreign bodies from the upper gastrointestinal tract, though a common occurrence, can be technically challenging and risky. We report the case of a young man that, after eating a pizza cooked in a wood-burning oven, reported a sense of foreign body. Though the first evaluation by fiberoptic laryngoscopy found no foreign body, after a few weeks, the patient was readmitted from the ER for worsening symptoms and fever. A CT scan showed a metallic mediastinal foreign body inside a large fluid collection. After multidisciplinary evaluation, an endoscopic removal was attempted by accessing the mediastinal collection through EUS-guided positioning of a Hot Axios™ stent. The cavity was drained by naso-esophageal suction. The foreign body was a fragment of the brush used to clean the oven. The patient is now doing well after 7 months.


Subject(s)
Endoscopy , Endosonography/methods , Esophagus , Foreign Bodies , Foreign-Body Migration , Mediastinum , Drainage/methods , Endoscopy/instrumentation , Endoscopy/methods , Esophagus/diagnostic imaging , Esophagus/pathology , Foreign Bodies/diagnostic imaging , Foreign Bodies/etiology , Foreign-Body Migration/complications , Foreign-Body Migration/diagnosis , Foreign-Body Migration/physiopathology , Foreign-Body Migration/surgery , Humans , Male , Mediastinum/diagnostic imaging , Mediastinum/pathology , Stents , Surgery, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Treatment Outcome , Young Adult
2.
Ann Vasc Surg ; 75: 479-488, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33823255

ABSTRACT

BACKGROUND: Despite the great evolution of endograft devices for thoracic endovascular aortic repair (TEVAR), threatening related complication such as graft migration and endoleaks still occur during follow up. The Drag Forces (DF), that is the displacement forces that play a role in graft migration and endoleaks caused by the blood flow against the thoracic graft, can be studied by means of Computational Fluid Dynamics (CFD). METHOD: A general review of papers found in current literature was performed. CFD studies available on the topic of thoracic aortic diseases and DF were analyzed. All anatomic, hemodynamics or graft related factors which could have an impact on DF were reported. RESULTS: Different factors deeply influence DF magnitude in the different site of the Ishimaru's zones classification: angulation, tortuosity and length of the landing zone, graft diameter, length and deployment position, blood pressure, pulse waveform, blood viscosity and patient heart rate have been related to the magnitude of DF. Moreover, also the three-dimensional orientation of DF is emerging as a fundamental issue from CFD studies. DF can be divided in sideways and upward components. The former, even of higher magnitude in zone 0, maintain always an orthogonal orientation and does not change in any type of aortic arch; the latter result strictly related to the anatomic complexity of the aortic arch with values up to four times higher in zone 3. CONCLUSION: Different DF magnitude and orientation could explain how TEVAR have higher rate of migration and endoleaks when we face with more complex aortic anatomies. All these aspects should be foreseen during the planning of TEVAR procedure. In this field, collaboration between physicians and engineers is crucial, as both parts have a primary role in understanding and describing hidden aspects involved in TEVAR procedures.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endovascular Procedures/adverse effects , Foreign-Body Migration/etiology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Diseases/diagnostic imaging , Aortic Diseases/physiopathology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Endoleak/diagnostic imaging , Endoleak/physiopathology , Endovascular Procedures/instrumentation , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/physiopathology , Humans , Hydrodynamics , Models, Cardiovascular , Patient-Specific Modeling , Regional Blood Flow , Risk Assessment , Risk Factors , Stress, Mechanical , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 95(1): E37-E39, 2020 01.
Article in English | MEDLINE | ID: mdl-30919551

ABSTRACT

A 73-year-old man with severe, symptomatic secondary mitral regurgitation (MR) underwent successful transcatheter mitral valve replacement using the Tendyne™ mitral valve system. The device was deployed from the left ventricular (LV) apex and secured in position by a tether attached to an epicardial pad. Three days postoperatively, the patient developed hemolytic anemia and a paravalvular leak (PVL) associated with indentation of the LV apex. Adjustment of the tether tension and placement of an epicardial disc under the pad resulted in reduction in the PVL, and resolution of the hemolytic anemia.


Subject(s)
Foreign-Body Migration/surgery , Heart Valve Prosthesis , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Anemia, Hemolytic/etiology , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Prosthesis Design , Reoperation , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
4.
J Endovasc Ther ; 26(5): 704-713, 2019 10.
Article in English | MEDLINE | ID: mdl-31315502

ABSTRACT

Purpose: This study investigated the effect of different EndoAnchor configurations on aortic endograft displacement resistance in an in vitro model. Materials and Methods: An in vitro model was developed and validated to perform displacement force measurements on different EndoAnchor configurations within an endograft and silicone tube. Five EndoAnchor configurations were created: (1) 6 circumferentially deployed EndoAnchors, (2) 5 EndoAnchors within 120° of the circumference and 1 additional, contralateral EndoAnchor, (3) 4 circumferentially deployed EndoAnchors, (4) 2 rows of 4 circumferentially deployed EndoAnchors, and (5) a configuration of 2 columns of 3 EndoAnchors. An experienced vascular surgeon deployed EndoAnchors under C-arm guidance at the proximal sealing zone of the endograft. A constant force with increments of 1 newton (N) was applied to the distal end of the endograft. The force necessary to displace a part of the endograft by 3 mm was defined as the endograft displacement force (EDF). Two video cameras recorded the measurements. Videos were examined to determine the exact moment 3-mm migration had occurred at part of the endograft. Five measurements were performed after each deployed EndoAnchor for each configuration. Measurements are given as the median and interquartile range (IQR) Q1, Q3. Results: Baseline displacement force measurement of the endograft without EndoAnchors resulted in a median EDF of 5.1 N (IQR 4.8, 5.2). The circumferential distribution of 6 EndoAnchors resulted in a median EDF of 53.7 N (IQR 49.0, 59.0), whereas configurations 2 through 5 demonstrated substantially lower EDFs of 29.0 N (IQR 28.5, 30.1), 24.6 N (IQR 21.9, 27.2), 36.7 N, and 9.6 N (IQR 9.4, 10.0), respectively. Decreasing the distance between the EndoAnchors over the circumference of the endograft increased the displacement resistance. Conclusion: This in vitro study demonstrates the influence EndoAnchor configurations have on the displacement resistance of an aortic endograft. Parts of the endograft where no EndoAnchor has been deployed remain sensitive to migration. In the current model, the only configuration that rivaled a hand-sewn anastomosis was the one with 6 EndoAnchors. A circumferential distribution of EndoAnchors with small distances between EndoAnchors should be pursued, if possible. This study provides a quantification of different EndoAnchor configurations that clinicians may have to adopt in clinical practice, which can help them make a measured decision on where to deploy EndoAnchors to ensure good endograft fixation.


Subject(s)
Aorta/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Hemodynamics , Aorta/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endoleak/physiopathology , Endovascular Procedures/adverse effects , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Humans , Materials Testing , Models, Anatomic , Models, Cardiovascular , Prosthesis Design , Regional Blood Flow , Stress, Mechanical , Video Recording
5.
J Endovasc Ther ; 26(2): 250-257, 2019 04.
Article in English | MEDLINE | ID: mdl-30898071

ABSTRACT

PURPOSE: To use computational simulations to compare the hemodynamic characteristics of a classic bifurcated stent-graft to an equally long endograft design with "dog bone"-shaped limbs (DB), which have large diameter proximal and distal ends and significant narrowing at the midsection to accommodate aneurysms with an extremely narrow bifurcation. MATERIALS AND METHODS: A 3-dimensional model was constructed using commercially available validated software. Inlet and outlet diameters were 28 and 14 mm, respectively. The total length of both models was kept constant to 180 mm, but the main body of the DB model was 20 mm shorter than the bifurcated endograft. The iliac limbs of the DB model had a 9-mm stenosis over a 30-mm segmental length in the midsection. Flow was quantified by time-averaged wall shear stress, oscillatory shear index (OSI), and relative residence time (RRT). The displacement forces in newtons (N) and maximum wall shear stress (WSS) in pascals (Pa) were compared during a cardiac cycle at 3 segments (main body, bifurcation, and iliac limbs) of both models with computational fluid dynamics analysis. RESULTS: The DB accommodation was associated with higher forces at the main body (range 3.15-4.9 Ν) compared with the classic configuration (1.56-2.34 N). On the contrary, the forces at the bifurcation (3.81-5.98 vs 3.76-5.54 N) and at the iliac limbs (0.34-0.85 vs 0.49-0.74 N) were comparable for both models. Accordingly, maximum WSS was detected at the iliac sites for both models throughout the cardiac cycle. The highest values were detected at peak systole and equaled 26.6 and 12 Pa for the DB and bifurcated configurations, respectively. The narrow segments in the DB model displayed high stress values but low OSI and very low RRT. CONCLUSION: The DB accommodation seems to correlate with higher displacement forces at the main body and higher stresses at the iliac limbs. Consequently, regular imaging follow-up of the DB design deems necessary to delineate its mid- and long-term clinical performance.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Computer Simulation , Endovascular Procedures/instrumentation , Hemodynamics , Models, Cardiovascular , Stents , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Prosthesis Design , Prosthesis Failure , Risk Factors , Stress, Mechanical , Thrombosis/etiology , Thrombosis/physiopathology
6.
J Endovasc Ther ; 26(6): 771-778, 2019 12.
Article in English | MEDLINE | ID: mdl-31364458

ABSTRACT

Purpose: To investigate the association between the bird-beak configuration (BBC), a wedge-shaped gap between the undersurface of a thoracic endograft and the lesser curvature of the arch after thoracic endovascular aortic repair (TEVAR), and postoperative outcome after TEVAR. Methods: The study was performed according to the PRISMA guidelines. The PubMed, EMBASE, and Cochrane databases were searched to identify all case series reporting BBC after TEVAR between 2006 and April 2018. Data analysis was performed considering the difference in the risk of complications for presence vs absence of BBC. After screening 1633 articles, 21 studies were identified that matched the selection criteria; 12 of these reported detailed information to investigate the postoperative outcome using proportion meta-analysis with a random effects model. The pooled risk difference is reported with the 95% confidence interval (CI). Heterogeneity of the included studies was assessed with the I2 statistic (low 25%, medium 50%, high 75%). Results: Complications occurred within a range of 0 to 72 months in 14.7% (95% CI 7.4% to 27.3%) of patients with BBC and in 6.3% (95% CI 2.5% to 15.4%) of patients without BBC. A cumulative incidence could not be assessed. The summary risk difference was 11.1% (95% CI -0.1% to 22.3%, p=0.052). There was significant heterogeneity (I2=85.6%). The Egger test did not show evidence of publication bias (p=0.975). When specifically considering type Ia endoleak and endograft migration, the risk difference between BBC and non-BBC patients was 8.2% (95% CI 0.3% to 16.1%, p=0.042; I2=69.0%). The specific risk difference for endograft collapse/infolding and thrombosis was 3.7% (95% CI -3.5% to 11.1%, p=0.308; I2=10.2%). Conclusion: At present the literature does not provide statistical evidence to establish an overall prognostic value of the BBC. Nevertheless, the BBC appears to be associated with a high risk of type Ia endoleak and endograft migration, which warrants specific and long-term surveillance. Clinically relevant values for BBC grading should be established to perhaps define indications for preemptive treatment based on the presence of BBC only.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Diseases/diagnostic imaging , Aortic Diseases/physiopathology , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/etiology , Endoleak/physiopathology , Endovascular Procedures/adverse effects , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Hemodynamics , Humans , Prosthesis Design , Risk Assessment , Risk Factors , Treatment Outcome
7.
J Pak Med Assoc ; 68(9): 1418-1420, 2018 Sep.
Article in English | MEDLINE | ID: mdl-30317283

ABSTRACT

Foreign body (FB) ingestion is one of the most common complaint in the emergency room and, extra-intestinal migration of penetrating sharp FBs is one of the most overlooked aspect of medical research. We report a case of accidental ingestion of a sewing needle which was recovered from the mesentery. The 28-year-old female presented to our hospital with abdominal pain and one-month's history of needle ingestion. Initially laparoscopy was performed, which was inconclusive. Afterward, through laparotomy, the needle was successfully removed from the mesentery of small bowel.


Subject(s)
Foreign Bodies , Foreign-Body Migration , Intestine, Small , Laparoscopy/methods , Mesentery , Needles , Abdominal Pain/diagnosis , Abdominal Pain/etiology , Adult , Eating , Female , Foreign Bodies/diagnosis , Foreign Bodies/physiopathology , Foreign Bodies/surgery , Foreign-Body Migration/diagnosis , Foreign-Body Migration/physiopathology , Foreign-Body Migration/surgery , Humans , Reoperation , Tomography, X-Ray Computed/methods , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 90(2): 346-349, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-27143657

ABSTRACT

An 84-year-old woman with a history of hemorrhagic stroke was admitted for a new cerebral ischemic event. While in hospital, she was diagnosed with paroxysmal atrial fibrillation. Owing to her high thromboembolic risk (CHA2 DS2 -VASc score of 6) we performed left atrial appendage (LAA) closure using a 22-mm AMPLATZER™ Amulet™. The procedure was successful. Systematic follow-up with transthoracic echocardiography 8 hr later revealed that the LAA occluder had migrated and become entrapped in the mitral subvalvular apparatus. At this time, the patient was asymptomatic. The device was recovered percutaneously using a loop-snare catheter, with no further complications. © 2016 Wiley Periodicals, Inc.


Subject(s)
Atrial Appendage , Atrial Fibrillation/therapy , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Foreign-Body Migration/etiology , Mitral Valve , Septal Occluder Device , Aged, 80 and over , Asymptomatic Diseases , Atrial Appendage/diagnostic imaging , Atrial Appendage/physiopathology , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Device Removal , Echocardiography, Transesophageal , Female , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/physiopathology , Foreign-Body Migration/therapy , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Prosthesis Design , Tomography, X-Ray Computed , Treatment Outcome
9.
J Endovasc Ther ; 24(5): 656-660, 2017 10.
Article in English | MEDLINE | ID: mdl-28689484

ABSTRACT

PURPOSE: To report emergent transcatheter aortic valve implantation (TAVI) to treat acute severe aortic regurgitation caused by valve cusp dysfunction following proximal migration of an endograft implanted in the ascending aorta during endovascular arch repair. CASE REPORT: A 65-year-old man had been previously treated with thoracic and fenestrated endografts in a 2-stage procedure for a chronic type B dissection. At 2-year follow-up, aneurysmal evolution of the distal arch led to development of a proximal type Ia endoleak. The patient was deemed unfit for open repair because of severe nonrevascularizable coronary artery disease. A custom-made endograft was designed consisting of a double inner branch arch endograft with a proximal component to reline the ascending aorta to avoid iatrogenic type A dissection. The first component was successfully deployed. However, this device migrated toward the aortic valve when the delivery system of the branch device was advanced through the aortic valve. Aortography and transesophageal echography showed acute aortic regurgitation due to obstruction of the left coronary valve cusp. An emergency bailout TAVI procedure was performed to successfully treat the aortic regurgitation. CONCLUSION: TAVI can be used as a bailout procedure for acute aortic valve dysfunction during endovascular arch or ascending aorta repair.


Subject(s)
Aortic Valve Insufficiency/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/surgery , Endovascular Procedures/instrumentation , Foreign-Body Migration/etiology , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Echocardiography, Transesophageal , Endoleak/diagnostic imaging , Endoleak/physiopathology , Endovascular Procedures/adverse effects , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/physiopathology , Humans , Male , Prosthesis Design , Treatment Outcome
10.
BMC Ophthalmol ; 17(1): 122, 2017 Jul 11.
Article in English | MEDLINE | ID: mdl-28693457

ABSTRACT

BACKGROUND: To assess the constants and formula for aphakia correction with iris-claw IOLs to achieve the best refractive status in cases of late in-the-bag IOL complex dislocation. METHODS: A literature search was performed. The following data were obtained: Iris-claw IOL model, Iridal or retroiridal enclavation, A-constant, ultrasound or optical biometry, formula employed and refractive outcomes. Acceptable emmetropia was considered if the resulting spherical equivalent (SE) was within ±1.00 D. RESULTS: The majority of the studies used SRK/T formula (66.6%). The 88.9% of the reports obtained a SE within ±1.00 D. Using A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, the emmetropia (±1.00 D) of SE, was able to get near 100% of reported cases over the pupil implantation. However, the emmetropia decreased to 80% when the enclavation is retropupilar using the same formula. The A-constant can vary from 116.7 to 117.5 for retropupilar enclavation. CONCLUSIONS: Using A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, ±1.00 D of SE, is able to get near 100% of cases. Nevertheless, ±1.00 D of SE decreased to 80% of the cases when the enclavation is retropupilar.


Subject(s)
Aphakia/surgery , Foreign-Body Migration/surgery , Iris/surgery , Lenses, Intraocular , Refraction, Ocular/physiology , Visual Acuity , Aphakia/physiopathology , Biometry/methods , Foreign-Body Migration/physiopathology , Humans , Prosthesis Design , Reoperation
11.
J Vasc Surg ; 63(3): 815-8, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25080881

ABSTRACT

Proximal displacement of thoracic aortic endografts is a catastrophic adverse event, which rarely occurs but is associated with extremely high morbidity and mortality. We describe herein the case of a patient with accidental proximal displacement of a thoracic endograft with occlusion of all supra-aortic branches, successfully rescued by the combination of three advanced endovascular techniques: (1) aggressive pull-back maneuver with a compliant balloon; (2) establishment of an arterio-arterial temporary shunt to the occluded carotid artery over sheaths; and (3) in-situ fenestration of the occluded carotid artery.


Subject(s)
Angioplasty, Balloon , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis/adverse effects , Carotid Artery, Common/surgery , Carotid Stenosis/therapy , Endovascular Procedures/adverse effects , Foreign-Body Migration/therapy , Stents/adverse effects , Aortic Dissection/diagnosis , Aortic Dissection/physiopathology , Aortic Aneurysm, Thoracic/diagnosis , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/instrumentation , Carotid Artery, Common/diagnostic imaging , Carotid Artery, Common/physiopathology , Carotid Stenosis/diagnosis , Carotid Stenosis/etiology , Carotid Stenosis/physiopathology , Carotid Stenosis/surgery , Endovascular Procedures/instrumentation , Foreign-Body Migration/diagnosis , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Foreign-Body Migration/surgery , Humans , Male , Middle Aged , Regional Blood Flow , Reoperation , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency
12.
J Endovasc Ther ; 23(4): 666-9, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27099287

ABSTRACT

PURPOSE: To report an uncommon case of chimney stent-graft migration in the aortic arch. CASE REPORT: A 29-year-old man presented with chronic left arm hyposthenia after late displacement and thrombosis of a left subclavian artery (LSA) chimney graft that migrated retrogradely into the innominate artery 2 years after deployment. The self-expanding LSA chimney was placed during a redo procedure to repair a pseudoaneurysm and type I endoleak after an index emergency thoracic endovascular aortic repair for traumatic aortic rupture 1 year earlier. The patient was successfully treated in an elective procedure via a median sternotomy, with arch aortotomy under circulatory arrest to remove the proximal end of the thrombosed chimney graft from the ostium of the innominate trunk. Three months later, a left carotid-to-subclavian bypass was performed to restore flow to the left arm. CONCLUSION: Migration of the proximal end of an overly long chimney graft that moved freely in the aortic arch exposed the patient to a high risk of stroke and death. Because of the high-risk situation, open repair under circulatory arrest was elected to remove the proximal end of the chimney graft, with no major complications.


Subject(s)
Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Brachiocephalic Trunk , Endovascular Procedures/instrumentation , Foreign-Body Migration/etiology , Stents , Subclavian Artery/surgery , Adult , Aorta, Thoracic/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Brachiocephalic Trunk/diagnostic imaging , Brachiocephalic Trunk/physiopathology , Brachiocephalic Trunk/surgery , Computed Tomography Angiography , Device Removal , Endovascular Procedures/adverse effects , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/physiopathology , Foreign-Body Migration/surgery , Hemodynamics , Humans , Male , Prosthesis Design , Regional Blood Flow , Reoperation , Subclavian Artery/diagnostic imaging , Subclavian Artery/physiopathology , Time Factors , Treatment Outcome
13.
J Endovasc Ther ; 23(1): 172-81, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26496956

ABSTRACT

PURPOSE: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. METHODS: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. RESULTS: The bird-beak configuration with the greatest protrusion extension exhibited the maximum TAG device displacement (1.66 mm), while the lowest protrusion extension configuration led to the minimum amount of both displacement and rotation parameters (0.25 mm and 0.6°, respectively). A positive relationship was found between the infolding parameters and the flow circulating in the aorta and left subclavian artery. Similarly, TAG device displacement was positively and significantly (p<0.05) correlated with the pulse pressure for all bird-beak configurations and device sizes. However, no collapse was observed under chronic perfusion testing maintained for 30 days and pulse pressure of 100 mm Hg. CONCLUSION: These findings suggest that endograft infolding depends primarily on the amount of aortic pulsatility and flow rate and that physiological flows do not necessarily engender hemodynamic loads on the proximal bird-beak segment sufficient to cause TAG collapse. Hemodynamic variables may allow for identification of patients at high risk of endograft infolding and help guide preventive intervention to avert its occurrence.


Subject(s)
Aorta, Thoracic/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Hemodynamics , Models, Anatomic , Models, Cardiovascular , Prosthesis Failure , Stents , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortography , Endovascular Procedures/adverse effects , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Prosthesis Design , Pulsatile Flow , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
14.
J Endovasc Ther ; 23(2): 297-301, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26868482

ABSTRACT

PURPOSE: To examine the changes in distraction force following relining of a conventional abdominal aortic stent-graft with a type IIIb endoleak using the Nellix endovascular sealing device compared to a unilateral stent-graft. METHODS: Relining is often used to repair type IIIb endoleaks, but the consequences to graft stability are unknown. A mathematical model was constructed based on pressure and volume flow through the stent-grafts, incorporating recognized distraction force equations. Steady flow was presumed at peak systolic pressures to calculate the maximum distraction force, with gravity ignored. Distraction forces for 28- to 36-mm-diameter stent-graft bodies with 16-mm limbs were calculated and compared to forces following relining with single and double Nellix devices or the Renu unilateral device. RESULTS: Distraction forces for the 28-, 32-, and 36-mm stent-grafts prior to relining were 5.99, 10.21, and 14.99 N, respectively. Similar forces were reported after relining with bilateral Nellix devices (5.86, 10.08, and 14.86 N, respectively). However, use of a unilateral Nellix increased the distraction forces to 9.92, 14.14, and 18.92 N, respectively. These were comparable to the increase observed after relining with a Renu unilateral stent-graft (9.87, 14.09, and 18.86 N, respectively). The proportional increase in distraction force for a unilateral relining ranged from 26% to 66%, with the greatest increase noted in the smaller diameter main bodies. CONCLUSION: Relining a stent-graft with a type IIIb endoleak using bilateral Nellix devices does not increase the distraction force. However, a unilateral Nellix device or the Renu system could theoretically increase the distraction force by up to 66%, potentially risking migration and type Ia endoleak. In clinical practice, these results suggest that a relining with bilateral Nellix may have benefits over the Renu unilateral stent-graft.


Subject(s)
Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/surgery , Endovascular Procedures/instrumentation , Hemodynamics , Models, Cardiovascular , Stents , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/physiopathology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Computed Tomography Angiography , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/physiopathology , Endovascular Procedures/adverse effects , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Humans , Prosthesis Design , Regional Blood Flow , Reoperation , Stress, Mechanical , Treatment Outcome
16.
J Vasc Surg ; 62(3): 578-84, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26087878

ABSTRACT

OBJECTIVE: The aim of this study was the evaluation of the clinical and radiologic outcomes of parallel grafts in the treatment of patients with failed prior endovascular aneurysm repair and type Ia endoleak. METHODS: Prospectively collected clinical and radiologic data of consecutive patients with prior endovascular aneurysm repair and evidence of type Ia endoleak were analyzed. All patients were treated between January 2009 and November 2014 by use of parallel grafts, ie, chimney/snorkel or periscope grafts and abdominal endovascular devices. Primary outcome of the study was the technical success. Secondary outcomes were patency of the chimney grafts and shrinkage of aneurysm morphology. RESULTS: Technical success was 94.4% (17 of 18). One patient showed evidence of persistent type Ia endoleak after triple chimney graft placement and treated by Onyx embolization (Covidien, Plymouth, Minn) successfully. The mean preoperative and postoperative aneurysm diameters were 7.1 ± 1.7 and 7.0 ± 2 cm. Primary patency of the chimney grafts was 96.7% and assisted patency was 100% after successful retrograde recanalization of an acute occlusion of the superior mesenteric artery from the celiac trunk and the gastroduodenal artery. One patient who had undergone the sandwich technique with transfemoral placement of the flexible Viabahn (W. L. Gore & Associates, Flagstaff, Ariz) due to impossible catheterization of the target vessel from the upper extremity presented with contained rupture caused by gutter-associated endoleak and underwent urgent embolization with Onyx successfully. No procedure-related death or open conversion was observed in the entire follow-up period. CONCLUSIONS: Use of parallel grafts showed midterm safety and feasibility with low incidence of persistent endoleaks requiring intervention or progression of aneurysm diameter. Reproducible results from other vascular centers will establish the chimney technique in the treatment of type I endoleaks as a viable endovascular modality.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endoleak/surgery , Endovascular Procedures/instrumentation , Foreign-Body Migration/surgery , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/physiopathology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnosis , Endoleak/etiology , Endoleak/physiopathology , Endovascular Procedures/adverse effects , Female , Foreign-Body Migration/diagnosis , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Humans , Kaplan-Meier Estimate , Male , Prospective Studies , Prosthesis Design , Reoperation , Risk Factors , Time Factors , Tomography, X-Ray Computed , Treatment Failure , Vascular Patency
17.
Br J Neurosurg ; 29(4): 585-6, 2015.
Article in English | MEDLINE | ID: mdl-25825326

ABSTRACT

Bullet injuries to the spine can cause significant damage to surrounding tissues and cause serious neurological sequelae. These cases are often associated with neurological deficits. We present a case of a gunshot injury to the spine with a migrating intrathecal bullet which subsequently developed neurological deficits. Initially, the patient did not exhibit any neurological symptoms when first assessed soon after the injury. Subsequently, the patient developed signs of neurological injury as a result of spinal intrathecal migration of the projectile.


Subject(s)
Foreign-Body Migration/pathology , Spinal Injuries/pathology , Wounds, Gunshot/pathology , Adult , Foreign-Body Migration/physiopathology , Foreign-Body Migration/surgery , Humans , Male , Spinal Injuries/physiopathology , Spinal Injuries/surgery , Wounds, Gunshot/physiopathology , Wounds, Gunshot/surgery
18.
Ir Med J ; 108(5): 149-50, 2015 May.
Article in English | MEDLINE | ID: mdl-26062243

ABSTRACT

Magnetic foreign body ingestion can have a very serious sequale if multiple or combined with another metal object inside the abdomen. We report 2 cases of ingestion of rare-earth magnets with a very different consequences. This adds to the world's literature on this topic.


Subject(s)
Digestive System Surgical Procedures/methods , Foreign-Body Migration , Intestinal Perforation , Intestines/diagnostic imaging , Magnets , Play and Playthings/injuries , Child , Child, Preschool , Female , Foreign-Body Migration/complications , Foreign-Body Migration/diagnosis , Foreign-Body Migration/physiopathology , Foreign-Body Migration/surgery , Humans , Intestinal Perforation/diagnostic imaging , Intestinal Perforation/etiology , Intestinal Perforation/surgery , Male , Metals, Rare Earth , Radiography , Treatment Outcome
19.
J Vasc Surg ; 60(6): 1648-56.e1, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25454107

ABSTRACT

OBJECTIVE: Secure fixation of endovascular stent grafts is essential for successful endovascular aneurysm repair. Hemodynamic distraction forces are generated by blood pressure and blood flow and act against fixation force to encourage migration that may eventually lead to late stent graft failure. The aim of this in silico study was to determine which morphologic features were associated with greater distraction force. METHODS: Computer models of 54 in situ fenestrated stent grafts were constructed from postoperative computed tomography scans by use of image processing software. Computational fluid dynamic analysis was then performed by use of a commercial finite volume solver with boundary conditions representative of peak systole. Distraction force results were obtained for each component of the stent graft. Distraction force was correlated with lumen cross-sectional area (XSA) at the inlet and outlet of components and was compared between groups of components, depending on the magnitude of four predefined angles within the aortoiliac territory that we describe in detail. RESULTS: Median total resultant distraction force (RDF) acting on the fenestrated proximal bodies was 4.8 N (1.3-15.7 N); bifurcated distal bodies, 5.6N (1.0-8.0 N); and limb extensions, 1.7 N (0.6-8.4N). Inlet XSA exhibited strong, positive correlation with total RDF in proximal body and distal body components (Spearman correlation coefficient ρ, 0.883 and 0.802, respectively). Outlet XSA exhibited a similarly strong, positive correlation with total RDF in limb extension components (ρ, 0.822). Outlet angulation ≥ 45 degrees was associated with greater total RDF in the limb extension components only (P = .004). CONCLUSIONS: For a given blood pressure, XSA was the most important morphologic determinant of total RDF. Angulation within the aorta was not large enough to influence this, whereas iliac angulation affecting outlet angulation of limb extension components was associated with significantly greater total RDF.


Subject(s)
Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Computer Simulation , Endovascular Procedures/instrumentation , Hemodynamics , Models, Cardiovascular , Stents , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/physiopathology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortography/methods , Arterial Pressure , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Foreign-Body Migration/etiology , Foreign-Body Migration/physiopathology , Humans , Prosthesis Design , Prosthesis Failure , Stress, Mechanical , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL