Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pediatr Cardiol ; 44(1): 132-140, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36029321

RESUMEN

The aim of the study was to determine the variables associated with high-quality (HQ) versus low-quality (LQ) three-dimensional rotational angiography (3DRA) and create guides for optimization of approach to 3DRA in congenital cardiac catheterization (CCC). CCC has adopted 3DRA as a mainstay, but there has not been systematic analysis of approach to and factors associated with HQ 3DRA. This was a single-center, retrospective study of 3DRAs using Canon Infinix-I platform. Reconstructions were graded by 3 interventionalists. Quality was dichotomized into HQ and LQ. Univariable analyses and multivariable logistic regression models were performed. From 8/2016 to 12/2018, 208 3DRAs were performed in 195 CCCs; median age 7 years (2, 16), weight 23 kg (12, 57). The majority of 3DRAs were performed in patients with biventricular physiology (N = 137, 66%) and in pulsatile sites (N = 144, 69%). HQ 3DRA (N = 182, 88%) was associated with greater total injection volume [2.20 mL/kg (1.44, 3.29) vs. 1.62 mL/kg (1.10, 1.98), p = 0.005] and more dilute contrast solution [60% (50, 100) vs. 100% (60, 100), p = 0.007], but not with contrast volume administered (p = 0.2) on univariable analysis. On multivariable logistic regression, HQ 3DRA was significantly associated with patient weight [OR 0.97 (95% CI (0.94, 0.99), p = 0.018], total injection volume [OR 1.04 (95% CI 1.01, 1.07) p = 0.011], and percent contrast solution [OR 0.97 (95% CI 0.95, 1.00), p = 0.022]. These data resulted in creation of scatter plots and a novel 3DRA Nomogram for estimating the probability of HQ 3DRA. This is the first study to create evidence-based contrast dose guides and nomogram for 3DRA in CCC. HQ 3DRA was associated with lower weight, higher total injection volumes, and more dilute contrast solution.


Asunto(s)
Imagenología Tridimensional , Procedimientos de Cirugía Plástica , Humanos , Niño , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Angiografía/métodos , Cateterismo Cardíaco/métodos
2.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36995404

RESUMEN

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Asunto(s)
Conducto Arterioso Permeable , Dispositivo Oclusor Septal , Lactante , Humanos , Conducto Arterioso Permeable/cirugía , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Sistema de Registros , Factores de Tiempo , Estudios Retrospectivos
3.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34743224

RESUMEN

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Asunto(s)
Defectos del Tabique Interatrial , Exposición a la Radiación , Dispositivo Oclusor Septal , Cateterismo Cardíaco/métodos , Fluoroscopía/métodos , Defectos del Tabique Interatrial/cirugía , Humanos , Mejoramiento de la Calidad , Dosis de Radiación , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento
4.
Cardiol Young ; 32(12): 1952-1956, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35152927

RESUMEN

BACKGROUND: Recurrent laryngeal nerve injury leading to vocal cord paralysis is a known complication of cardiothoracic surgery. Its occurrence during interventional catheterisation procedures has been documented in case reports, but there have been no studies to determine an incidence. OBJECTIVE: To establish the incidence of left recurrent laryngeal nerve injury leading to vocal cord paralysis after left pulmonary artery stenting, patent ductus arteriosus device closure and the combination of the procedures either consecutively or simultaneously. METHODS: Members of the Congenital Cardiovascular Interventional Study Consortium were asked to perform a retrospective analysis to identify cases of recurrent laryngeal nerve injury after the aforementioned procedures. Twelve institutions participated in the analysis. They also contributed the total number of each procedure performed at their respective institutions for statistical purposes. RESULTS: Of the 1337 patients who underwent left pulmonary artery stent placement, six patients (0.45%) had confirmed vocal cord paralysis. 4001 patients underwent patent ductus arteriosus device closure, and two patients (0.05%) developed left vocal cord paralysis. Patients who underwent both left pulmonary artery stent placement and patent ductus arteriosus device closure had the highest incidence of vocal cord paralysis which occurred in 4 of the 26 patients (15.4%). Overall, 92% of affected patients in our study population had resolution of symptoms. CONCLUSION: Recurrent laryngeal nerve injury is a rare complication of left pulmonary artery stent placement or patent ductus arteriosus device closure. However, the incidence is highest in patients undergoing both procedures either consecutively or simultaneously. Additional research is necessary to determine contributing factors that might reduce the risk of recurrent laryngeal nerve injury.


Asunto(s)
Conducto Arterioso Permeable , Traumatismos del Nervio Laríngeo Recurrente , Parálisis de los Pliegues Vocales , Humanos , Traumatismos del Nervio Laríngeo Recurrente/etiología , Traumatismos del Nervio Laríngeo Recurrente/complicaciones , Parálisis de los Pliegues Vocales/epidemiología , Parálisis de los Pliegues Vocales/etiología , Conducto Arterioso Permeable/epidemiología , Conducto Arterioso Permeable/cirugía , Conducto Arterioso Permeable/complicaciones , Incidencia , Estudios Retrospectivos , Cateterismo/efectos adversos
5.
Cardiol Young ; 31(9): 1407-1411, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33597057

RESUMEN

BACKGROUND: Three-dimensional printing is increasingly utilised for congenital heart defect procedural planning. CT or MR datasets are typically used for printing, but similar datasets can be obtained from three-dimensional rotational angiography. We sought to assess the feasibility and accuracy of printing three-dimensional models of CHD from rotational angiography datasets. METHODS: Retrospective review of CHD catheterisations using rotational angiography was performed, and patient and procedural details were collected. Imaging data from rotational angiography were segmented, cleaned, and printed with polylactic acid on a Dremel® 3D Idea Builder (Dremel, Mount Prospect, IL, USA). Printing time and materials' costs were captured. CT scans of printed models were compared objectively to the original virtual models. Two independent, non-interventional paediatric cardiologists provided subjective ratings of the quality and accuracy of the printed models. RESULTS: Rotational angiography data from 15 catheterisations on vascular structures were printed. Median print time was 3.83 hours, and material costs were $2.84. The CT scans of the printed models highly matched with the original digital models (root mean square for Hausdorff distance 0.013 ± 0.003 mesh units). Independent reviewers correctly described 80 and 87% of the models (p = 0.334) and reported high quality and accuracy (5 versus 5, p = NS; κ = 0.615). CONCLUSION: Imaging data from rotational angiography can be converted into accurate three-dimensional-printed models of CHD. The cost of printing the models was negligible, but the print time was prohibitive for real-time use. As the speed of three-dimensional printing technology increases, novel future applications may allow for printing patient-specific devices based on rotational angiography datasets.


Asunto(s)
Cardiopatías Congénitas , Impresión Tridimensional , Angiografía , Cateterismo Cardíaco , Niño , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Modelos Anatómicos , Estudios Retrospectivos
6.
Catheter Cardiovasc Interv ; 95(2): 270-279, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31609082

RESUMEN

OBJECTIVE: We describe the technical considerations of transcatheter implantation of the CardioMEMS™ HF System (Abbott, Abbott Park, IL) in adult patients with complex palliated congenital heart disease (CHD) and advanced heart failure (HF). BACKGROUND: Ambulatory pulmonary artery (PA) pressure monitoring with implantable hemodynamic monitors (IHMs) has been shown to reduce HF-related hospital admissions in non-CHD populations. HF is a common late cardiovascular complication in adult CHD necessitating better understanding of IHM application in this population. METHODS: We analyzed adults with complex CHD and advanced HF who were referred for CardioMEMS™ device implantation (2015-2018). Feasibility of device implantation, defined by successful device implantation and calibration, and procedural outcomes were evaluated. RESULTS: CardioMEMS™ was successfully implanted in all 14 adults (35.5 ± 9.2 years old, 72 ± 12 kg) with complex CHD (single ventricle/Fontan, n = 8 [57%]; d-transposition of the great arteries/atrial switch, n = 6 [43%]). The device was delivered via femoral venous access in 13 (93%) patients and implanted in the left PA in 12 (86%). A long sheath was used in 8 (57%) patients, including 5/6 with an atrial switch operation. There was one device migration that did not require retrieval. CONCLUSIONS: Transcatheter implantation of an IHM is feasible in select complex adult CHD patients with advanced HF. Further studies evaluating integration of ambulatory hemodynamics and the impact on clinical care are needed. This technology has the potential to improve medical management of advanced HF in patients with Fontan and atrial switch physiologies and provide new insights into their ambulatory hemodynamics.


Asunto(s)
Presión Arterial , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitores de Presión Sanguínea , Cardiopatías Congénitas/terapia , Insuficiencia Cardíaca/diagnóstico , Cuidados Paliativos , Arteria Pulmonar/fisiopatología , Tecnología de Sensores Remotos/instrumentación , Adulto , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
7.
J Pediatr ; 212: 144-150.e3, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31262530

RESUMEN

OBJECTIVES: To describe longer term outcomes for infants <6 kg undergoing percutaneous occlusion of the patent ductus arteriosus (PDA). STUDY DESIGN: This was a retrospective cohort study of infants <6 kg who underwent isolated percutaneous closure of the PDA at a single, tertiary center (2003-2017). Cardiopulmonary outcomes and device-related complications (eg, left pulmonary artery obstruction) were examined for differences across weight thresholds (very low weight, <3 kg; low weight, 3-<6 kg). We assessed composite measures of respiratory status during and beyond the initial hospitalization using linear mixed effects models. RESULTS: In this cohort of lower weight infants, 92 of 106 percutaneous occlusion procedures were successful. Median age and weight at procedure were 3.0 months (range, 0.5-11.1 months) and 3.7 kg (range, 1.4-5.9 kg), respectively. Among infants with pulmonary artery obstruction on initial postprocedural echocardiograms (n = 20 [22%]), obstruction persisted through hospital discharge in 3 infants. No measured variables were associated with device-related complications. Rates of oxygenation failure (28% vs 8%; P < .01) and decreased left ventricular systolic function (29% vs 5%; P < .01) were higher among very low weight than low weight infants. Pulmonary scores decreased (indicating improved respiratory status) following percutaneous PDA closure. CONCLUSIONS: Percutaneous PDA occlusion among lower weight infants is associated with potential longer term improvements in respiratory health. Risks of device-related complications and adverse cardiopulmonary outcomes, particularly among very low weight infants, underscore the need for continued device modification. Before widespread use, clinical trials comparing percutaneous occlusion vs alternative treatments are needed.


Asunto(s)
Conducto Arterioso Permeable/terapia , Oclusión Terapéutica , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido de Bajo Peso , Recién Nacido , Masculino , Estudios Retrospectivos , Oclusión Terapéutica/métodos , Factores de Tiempo , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 87(4): 768-72, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26152592

RESUMEN

Transcatheter pulmonary valves are being used off-label to treat pulmonary insufficiency in patched right ventricular outflow tracts (RVOTs). We describe the first reported cases of patched RVOT rupture, during balloon sizing for percutaneous pulmonary valve implantation, in two patients with tetralogy of Fallot status post repair. Both RVOTs were too large for subsequent catheter-based intervention. The ruptures remained stable over time, and both patients were managed conservatively with follow-up imaging.


Asunto(s)
Valvuloplastia con Balón , Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar/terapia , Válvula Pulmonar , Tetralogía de Fallot/cirugía , Obstrucción del Flujo Ventricular Externo/terapia , Adolescente , Cateterismo Cardíaco/métodos , Niño , Angiografía Coronaria , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Lactante , Recién Nacido , Masculino , Diseño de Prótesis , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Tetralogía de Fallot/diagnóstico , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología
9.
Catheter Cardiovasc Interv ; 88(7): 1113-1117, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27184689

RESUMEN

A 28-year-old male with single ventricular heart disease status post Fontan palliation and subsequent placement of left ventricle to ascending aorta (LV-AAo) valved conduit developed ascites and edema. Diagnostic catheterization revealed elevated ventricular end diastolic pressures (EDP) secondary to severe LV-AAo conduit regurgitation. Given the unique anatomy, surgical access via the right axillary artery provided optimal route for transcatheter valve implantation within the conduit. The procedure resulted in significant hemodynamic improvement with no complications. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Bioprótesis , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Cardíaco/instrumentación , Procedimientos Endovasculares/instrumentación , Procedimiento de Fontan/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Válvula Pulmonar/trasplante , Función Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo/cirugía , Adulto , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Cateterismo Cardíaco/métodos , Procedimientos Endovasculares/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Cuidados Paliativos , Etiquetado de Productos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Reoperación , Factores de Riesgo , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología
10.
Pediatr Cardiol ; 37(8): 1525-1533, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27567910

RESUMEN

We sought to describe the use and outcomes of small, medium and large premounted stents in patients with congenital heart disease, including incidence of and risk factors for re-intervention and development of in-stent stenosis. Premounted stents offer several advantages over traditional manually crimped bare-metal stents, especially in small patients. There are no data describing the medium-term effectiveness and outcomes of premounted stents in congenital heart disease. We performed a single-center retrospective review of all small, medium and large premounted stents implanted over an 8-year period. Premounted stents were implanted in 71 vessels within 59 patients with a 97 % success rate. Regardless of implantation site, premounted stent implantation resulted in significant improvements in vessel size and pressure gradient (p < 0.0001). Over a median follow-up duration of 3.1 years [interquartile range (IQR) 1.3-5.2], 25 patients (43 %) required re-intervention (18 catheter based, 3 surgical and 4 hybrid) at a median time of 1.4 years (IQR 0.9-3.0) from implant. Factors associated with re-intervention included age ≤1.9 years [hazard ratio (HR) 2.4, p = 0.03], weight ≤11.5 kg (HR 2.5, p = 0.03) and bare-metal premounted stents compared to covered premounted stents (HR 4.2, p = 0.001). In-stent stenosis was diagnosed in 42 % of premounted stents which underwent follow-up angiography. No identified characteristics were associated with in-stent stenosis, including "oversizing" the premounted stent. Small, medium and large premounted stents are effective in treating vascular stenosis in congenital heart disease. Frequent follow-up is required, especially in smaller patients with expected somatic growth, and to evaluate for in-stent stenosis which occurs in nearly half of premounted stents.


Asunto(s)
Cardiopatías Congénitas , Niño , Constricción Patológica , Humanos , Estudios Retrospectivos , Stents , Resultado del Tratamiento
11.
Pediatr Crit Care Med ; 16(8): 726-32, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26132744

RESUMEN

OBJECTIVES: Patients with congenital heart disease may have limited venous access routes as a result of multiple central venous catheters, surgical interventions, and catheterization procedures. Unconventional venous access includes transhepatic central venous catheter. We evaluated transhepatic central venous catheter placed in patients with congenital heart disease and risk factors associated with complications and outcomes. DESIGN: Demographic, procedural, and complication data were retrospectively collected on all patients who underwent transhepatic central venous catheter placement at our center over the past 10 years. SETTING: This study was completed in a tertiary congenital heart center. PATIENTS: A total of 92 transhepatic central venous catheters were placed in 54 patients (63% male patients). The median age and weight of the patient population was 5.7 months and 5.5 kg, respectively. INTERVENTIONS: Placement of a transhepatic central venous catheter. MEASUREMENTS AND MAIN RESULTS: Successful catheter placement occurred in 96% of cases with median procedure time of 54 minutes with a procedural complication rate of 14%. A total of 86 complications occurred in 54 catheters placed during 2,166 catheter-days (39.7 complications per 1,000 catheter-days). Individual complication rates per 1,000 catheter-days included catheter dysfunction (14.8), dislodgement (8.8), systemic infection (5.1), thrombosis (4.2), local infection (3.7), and bleeding (3.2). Two complications contributed to patient deaths. Factors associated with developing complications included polyurethane central venous catheters (p = 0.03) and catheter duration at least 21 days (p = 0.004). The overall mortality in this population was 50% with median length of hospitalization of 49 days (interquartile range, 33-97). CONCLUSIONS: Transhepatic central venous catheters represent a viable option for patients with limited access. Polyurethane catheters and catheter duration at least 21 days are associated with increased transhepatic central venous catheter complications. Although complication rates are higher than more traditional forms of central venous catheters, the long duration of hospitalization and high mortality rates in this patient population attest to their risks for poor outcomes irrespective of venous access.


Asunto(s)
Cateterismo Venoso Central/métodos , Catéteres Venosos Centrales/efectos adversos , Cardiopatías Congénitas/cirugía , Venas Hepáticas/cirugía , Femenino , Humanos , Lactante , Masculino , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Tiempo
12.
J Innov Card Rhythm Manag ; 15(8): 5990-5996, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39193536

RESUMEN

Current leadless pacemaker (LP) systems, which have been developed and used in patients with normal cardiac anatomy, are rare and technically even more challenging to implant in patients with congenital heart diseases, especially with univentricular physiology and Fontan palliation. We report two cases of percutaneous LP implantation in an adult and a child, respectively, highlighting the unconventional approaches, different challenges, and use of multimodality imaging in patients who underwent a Fontan operation.

13.
Circ Cardiovasc Interv ; 17(7): e013729, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38666384

RESUMEN

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.


Asunto(s)
Angioplastia de Balón , Aorta Torácica , Diseño de Prótesis , Stents , Humanos , Estudios Retrospectivos , Masculino , Femenino , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aorta Torácica/fisiopatología , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Adolescente , Adulto Joven , Angioplastia de Balón/instrumentación , Angioplastia de Balón/efectos adversos , Niño , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/terapia , Enfermedades de la Aorta/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/terapia , Constricción Patológica , Estados Unidos , Aortografía
14.
JTCVS Open ; 15: 433-445, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37808023

RESUMEN

Objectives: Palliative treatment of cyanotic congenital heart disease (CCHD) uses systemic-to-pulmonary conduits, often a modified Blalock-Taussig-Thomas shunt (mBTTs). Expanded polytetrafluoroethylene (ePTFE) mBTTs have associated risks for thrombosis and infection. The Human Acellular Vessel (HAV) (Humacyte, Inc) is a decellularized tissue-engineered blood vessel currently in clinical trials in adults for vascular trauma, peripheral artery disease, and end-stage renal disease requiring hemodialysis. In addition to restoring blood flow, the engineered HAV demonstrates the capacity for host cellular remodeling into native-like vasculature. Here we report preclinical evaluation of a small-diameter (3.5 mm) HAV as a mBTTs in a non-human primate model. Methods: We implanted 3.5 mm HAVs as right subclavian artery to pulmonary artery mBTTs in non-immunosuppressed juvenile rhesus macaques (n = 5). HAV patency, structure, and blood flow were assessed by postoperative imaging from 1 week to 6 months. Histology of HAVs and surrounding tissues was performed. Results: Surgical procedures were well tolerated, with satisfactory anastomoses, showing feasibility of using the 3.5 mm HAV as a mBTTs. All macaques had some immunological reactivity to the human extracellular matrix, as expected in this xenogeneic model. HAV mBTTs remained patent for up to 6 months in animals, exhibiting mild immunoreactivity. Two macaques displaying more severe immunoreactivity to the human HAV material developed midgraft dilatation without bleeding or rupture. HAV repopulation by host cells expressing smooth muscle and endothelial markers was observed in all animals. Conclusions: These findings may support use of 3.5 mm HAVs as mBTTs in CCHD and potentially other pediatric vascular indications.

15.
J Soc Cardiovasc Angiogr Interv ; 2(6Part A): 101119, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-39129900

RESUMEN

Background: Safety events and technical success (TS) have been previously reported for aortic and pulmonary valvuloplasty, but a composite performance measure as a novel, patient-centered strategy has neither been developed nor been studied. This study aims to refine a procedural performance (PP) variable, a composite of TS and procedural safety, for isolated, standard-risk aortic and pulmonary valvuloplasty. Methods: A multicenter review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes registry. Data were collected for all cases of isolated balloon aortic and pulmonary valvuloplasty from 2014 through 2017. Patients were excluded if they were aged <1 month, were inpatient at the time of the procedure, or had significant comorbidities, such as Williams or Noonan syndrome. Criteria for TS were developed and categorized (optimal, satisfactory, and unsatisfactory) by expert consensus based on previous outcome research. Adverse events (AE) were categorized by severity (level 1-5) using established criteria. Level 4 and 5 severity AE were considered high-severity AE. Using criteria of TS and AE severity, PP was divided into 3 composite outcome classes. Factors correlating with class III (suboptimal) PP were analyzed. Results: There were 169 cases of aortic and 270 cases of pulmonary valvuloplasty in the cohorts. In the aortic valvuloplasty cohort, a suboptimal PP (class III) occurred in 14% of cases, mostly due to high-severity AE (7%). No significant correlation between patient or case characteristics and PP was demonstrated. In the pulmonary valvuloplasty cohort, class III PP occurred in 9% of cases, predominantly due to residual valve gradient, which correlated with lower weight (P = .02). Conclusions: We designed a composite variable of PP consisting of TS and safety as a comprehensive measure of outcome. Incorporating both TS and AE may better reflect patient outcome than each metric measured separately. PP indices may identify areas for further investigation and quality improvement.

16.
JACC Cardiovasc Interv ; 16(15): 1917-1928, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37278682

RESUMEN

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is the first U.S. Food and Drug Administration-approved device for severe pulmonary regurgitation (PR) in the native or surgically repaired right ventricular outflow tract (RVOT). OBJECTIVES: One-year safety and effectiveness of the Harmony TPV were evaluated in patients from the Harmony Native Outflow Tract Early Feasibility Study, Harmony TPV Pivotal Study, and Continued Access Study, representing the largest cohort to date of Harmony TPV recipients. METHODS: Eligible patients had severe PR by echocardiography or PR fraction ≥ 30% by cardiac magnetic resonance imaging and clinical indications for pulmonary valve replacement. The primary analysis included 87 patients who received a commercially available TPV22 (n = 42) or TPV25 (n = 45) device; 19 patients who received an early device iteration prior to its discontinuation were evaluated separately. RESULTS: In the primary analysis, median patient age at treatment was 26 years (IQR: 18-37 years) in the TPV22 group and 29 years (IQR: 19-42 years) in the TPV25 group. At 1 year, there were no deaths; 98% of TPV22 and 91% of TPV25 patients were free from the composite of PR, stenosis, and reintervention (moderate or worse PR, mean RVOT gradient >40 mmHg, device-related RVOT reoperation, and catheter reintervention). Nonsustained ventricular tachycardia occurred in 16% of patients. Most patients had none/trace or mild PR (98% of TPV22 patients, 97% of TPV25 patients). Outcomes with the discontinued device are reported separately. CONCLUSIONS: The Harmony TPV device demonstrated favorable clinical and hemodynamic outcomes across studies and valve types through 1 year. Further follow-up will continue to assess long-term valve performance and durability.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Obstrucción del Flujo Ventricular Externo , Humanos , Cateterismo Cardíaco , Estudios Prospectivos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/etiología
17.
JACC Adv ; 1(5): 100143, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36471862

RESUMEN

Background: The COVID-19 pandemic has posed tremendous stress on the health care system. Its effects on pediatric/congenital catheterization program practice and performance have not been described. Objectives: The purpose of this study was to evaluate how case volumes, risk-profile, and outcomes of pediatric/congenital catheterization procedures changed in response to the first wave of COVID-19 and after that wave. Methods: A multicenter retrospective observational study was performed using Congenital Cardiac Catheterization Project on Outcomes Registry (C3PO) data to study changes in volume, case mix, and outcomes (high-severity adverse events [HSAEs]) during the first wave of COVID (March 1, 2020, to May 31, 2020) in comparison to the period prior to (January 1, 2019, to February 28, 2020) and after (June 1, 2020, to December 31, 2020) the first wave. Multivariable analyses adjusting for case type, hemodynamic vulnerability, and age group were performed. Hospital responses to the first wave were captured with an electronic study instrument. Results: During the study period, 12,557 cases were performed at 14 C3PO hospitals (with 8% performed during the first wave of COVID and 32% in the postperiod). Center case volumes decreased from a median 32.1 cases/month (IQR: 20.7-49.0 cases/month) before COVID to 22 cases/month (IQR: 13-31 cases/month) during the first wave (P = 0.001). The proportion of cases with risk factors for HSAE increased during the first wave, specifically proportions of infants and neonates (P < 0.001) and subjects with renal insufficiency (P = 0.02), recent cardiac surgery (P < 0.001), and a higher hemodynamic vulnerability score (P = 0.02). The observed HSAE risk did not change significantly (P = 0.13). In multivariable analyses, odds of HSAE during the first wave of COVID (odds ratio: 0.75) appeared to be lower than that before COVID, but the difference was not significant (P = 0.09). Conclusions: Despite increased case-mix complexity, C3PO programs maintained, if not improved, their performance in terms of HSAE. Exploratory analyses of practice changes may inform future harm-reduction efforts.

18.
JACC Cardiovasc Interv ; 15(9): 979-988, 2022 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-35512922

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the accuracy of cardiac magnetic resonance (CMR) in predicting coronary artery (CA) compression during transcatheter pulmonary valve implantation (TPVi). BACKGROUND: TPVi is a widely available option to treat dysfunctional right ventricle (RV)-to-pulmonary artery (PA) conduits, but CA compression is an absolute contraindication. CMR can evaluate coronary anatomy, but its utility in predicting CA compression is not well established. METHODS: After Institutional Review Board approval was obtained, all patients at 9 centers with attempted TPVi in RV-PA conduits and recent CMR (≤12 months) were analyzed. A core laboratory reviewed all CMR studies for the shortest orthogonal distance from a CA to the conduit, the shortest distance from a CA to the most stenotic area of the conduit, and subjective assessment of CA compression risk. RESULTS: Among 231 patients, TPVi was successful in 198 (86%); in 24 (10%), balloon testing precluded implantation (documented CA compression or high risk). Distance to the RV-PA conduit ≤2.1 mm (area under the curve [AUC]: 0.70) and distance to most stenotic area ≤13.1 mm (AUC: 0.69) predicted CA compression. Subjective assessment had the highest AUC (0.78), with 96% negative predictive value. Both distances and qualitative assessment remained independently associated with CA compression when controlling for abnormal coronary anatomy or degree of conduit calcification. CONCLUSIONS: CMR can help predict the risk for CA compression during TPVi in RV-PA conduits but cannot completely exclude CA compression. CMR may assist in patient selection and counseling families prior to TPVi, although balloon testing remains essential.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Válvula Pulmonar , Cateterismo Cardíaco/efectos adversos , Vasos Coronarios , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Espectroscopía de Resonancia Magnética , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
19.
Commun Med (Lond) ; 2: 3, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35603301

RESUMEN

Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid-structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.

20.
Biomedicines ; 9(5)2021 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-33925558

RESUMEN

Bioabsorbable materials made from polymeric compounds have been used in many fields of regenerative medicine to promote tissue regeneration. These materials replace autologous tissue and, due to their growth potential, make excellent substitutes for cardiovascular applications in the treatment of congenital heart disease. However, there remains a sizable gap between their theoretical advantages and actual clinical application within pediatric cardiovascular surgery. This review will focus on four areas of regenerative medicine in which bioabsorbable materials have the potential to alleviate the burden where current treatment options have been unable to within the field of pediatric cardiovascular surgery. These four areas include tissue-engineered pulmonary valves, tissue-engineered patches, regenerative medicine options for treatment of pulmonary vein stenosis and tissue-engineered vascular grafts. We will discuss the research and development of biocompatible materials reported to date, the evaluation of materials in vitro, and the results of studies that have progressed to clinical trials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA