1.
Int J Mol Sci ; 24(11)2023 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-37298388

RESUMEN

Traumatic brain injury (TBI) is an established risk factor for neurodegenerative diseases. In this study, we used the Closed Head Injury Model of Engineered Rotational Acceleration (CHIMERA) to investigate the effects of a single high-energy TBI in rTg4510 mice, a mouse model of tauopathy. Fifteen male rTg4510 mice (4 mo) were impacted at 4.0 J using interfaced CHIMERA and were compared to sham controls. Immediately after injury, the TBI mice showed significant mortality (7/15; 47%) and a prolonged duration of loss of the righting reflex. At 2 mo post-injury, surviving mice displayed significant microgliosis (Iba1) and axonal injury (Neurosilver). Western blotting indicated a reduced p-GSK-3ß (S9):GSK-3ß ratio in TBI mice, suggesting chronic activation of tau kinase. Although longitudinal analysis of plasma total tau suggested that TBI accelerates the appearance of tau in the circulation, there were no significant differences in brain total or p-tau levels, nor did we observe evidence of enhanced neurodegeneration in TBI mice compared to sham mice. In summary, we showed that a single high-energy head impact induces chronic white matter injury and altered GSK-3ß activity without an apparent change in post-injury tauopathy in rTg4510 mice.


Asunto(s)
Lesiones Traumáticas del Encéfalo , Traumatismos Cerrados de la Cabeza , Tauopatías , Ratones , Masculino , Animales , Glucógeno Sintasa Quinasa 3 beta/genética , Lesiones Traumáticas del Encéfalo/genética , Encéfalo/metabolismo , Tauopatías/genética , Modelos Animales de Enfermedad , Aceleración , Proteínas tau/genética , Proteínas tau/metabolismo
2.
J Biomech Eng ; 142(8)2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32006027

RESUMEN

Mild traumatic brain injuries are typically caused by nonpenetrating head impacts that accelerate the skull and result in deformation of the brain within the skull. The shear and compressive strains caused by these deformations damage neural and vascular structures and impair their function. Accurate head acceleration measurements are necessary to define the nature of the insult to the brain. A novel murine head tracking system was developed to improve the accuracy and efficiency of kinematic measurements obtained with high-speed videography. A three-dimensional (3D)-printed marker carrier was designed for rigid fixation to the upper jaw and incisors with an elastic strap around the snout. The system was evaluated by impacting cadaveric mice with the closed head impact model of engineered rotational acceleration (CHIMERA) system using an energy of 0.7 J (5.29 m/s). We compared the performance of the head-marker system to the previously used skin-tracking method and documented significant improvements in measurement repeatability (aggregate coefficient of variation (CV) within raters from 15.8 to 1.5 and between raters from 15.5 to 1.5), agreement (aggregate percentage error from 24.9 to 8.7), and temporal response (aggregate temporal curve agreement from 0.668 to 0.941). Additionally, the new system allows for automated software tracking, which dramatically decreases the analysis time required (74% reduction). This novel head tracking system for mice offers an efficient, reliable, and real-time method to measure head kinematics during high-speed impacts using CHIMERA or other rodent or small mammal head impact models.


Asunto(s)
Conmoción Encefálica , Aceleración , Fenómenos Biomecánicos , Rotación
3.
J Biomech Eng ; 142(10)2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32451551

RESUMEN

In contrast to sagittal plane spine biomechanics, little is known about the response of the cervical spine to axial compression with lateral eccentricity of the applied force. This study evaluated the effect of lateral eccentricity on the kinetics, kinematics, canal occlusion, injuries, and flexibility of the cervical spine in translationally constrained axial impacts. Eighteen functional spinal units were subjected to flexibility tests before and after an impact. Impact axial compression was applied at one of three lateral eccentricity levels based on percentage of vertebral body width (low = 5%, medium = 50%, high = 150%). Injuries were graded by dissection. Correlations between intrinsic specimen properties and injury scores were examined for each eccentricity group. Low lateral force eccentricity produced predominantly bone injuries, clinically recognized as compression injuries, while medium and high eccentricity produced mostly contralateral ligament and/or disc injuries, an asymmetric pattern typical of lateral loading. Mean compression force at injury decreased with increasing lateral eccentricity (low = 3098 N, medium = 2337 N, and high = 683 N). Mean ipsilateral bending moments at injury were higher at medium (28.3 N·m) and high (22.9 N·m) eccentricity compared to low eccentricity specimens (0.1 N·m), p < 0.05. Ipsilateral bony injury was related to vertebral body area (VBA) (r = -0.974, p = 0.001) and disc degeneration (r = 0.851, p = 0.032) at medium eccentricity. Facet degeneration was correlated with central bony injury at high eccentricity (r = 0.834, p = 0.036). These results deepen cervical spine biomechanics knowledge in circumstances with coronal plane loads.


Asunto(s)
Vértebras Cervicales , Fenómenos Biomecánicos , Degeneración del Disco Intervertebral , Presión
4.
J Biomech Eng ; 2019 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-30861063

RESUMEN

Standards for sports headgear were introduced as far back as the 1960s and many have remained substantially unchanged to present day. Since this time, headgear has virtually eliminated catastrophic head injuries such as skull fractures and changed the landscape of head injuries in sports. Mild traumatic brain injury (mTBI) is now a prevalent concern and the effectiveness of headgear in mitigating mTBI is inconclusive for most sports. Given that most current headgear standards are confined to attenuating linear head mechanics and recent brain injury studies have underscored the importance of angular mechanics in the genesis of mTBI, new or expanded standards are needed to foster headgear development and assess headgear performance that addresses all types of sport-related head and brain injuries. The aim of this review is to provide a basis for developing new sports headgear impact tests for standards by summarizing and critiquing: 1) impact testing procedures currently codified in published headgear standards for sports and 2) new or proposed headgear impact test procedures in published literature and/or relevant conferences. Research areas identified as needing further knowledge to support standards test development include defining sports-specific head impact conditions, establishing injury and age appropriate headgear assessment criteria, and the development of headgear specific head and neck surrogates for at-risk populations.

5.
Eur Spine J ; 24(1): 136-47, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25344091

RESUMEN

PURPOSE: Determine the effects of dynamic injurious axial compression applied at various lateral eccentricities (lateral distance to the centre of the spine) on mechanical flexibilities and structural injury patterns of the cervical spine. METHODS: 13 three-vertebra human cadaver cervical spine specimens (6 C3-5, 3 C4-6, 2 C5-7, 2 C6-T1) were subjected to pure moment flexibility tests (±1.5 Nm) before and after impact trauma was applied in two groups: low and high lateral eccentricity (1 and 150 % of the lateral diameter of the vertebral body, respectively). Relative range of motion (ROM) and relative neutral zone (NZ) were calculated as the ratio of post and pre-trauma values. Injuries were diagnosed by a spine surgeon and scored. Classification functions were developed using discriminant analysis. RESULTS: Low and high eccentric loading resulted in primarily bony fractures and soft tissue injuries, respectively. Axial impacts with high lateral eccentricities resulted in greater spinal motion in lateral bending [median relative ROM 3.5 (interquartile range, IQR 2.3) vs. 1.4 (IQR 0.5) and median relative NZ 4.7 (IQR 3.7) vs. 2.3 (IQR 1.1)] and in axial rotation [median relative ROM 5.3 (IQR 13.7) vs. 1.3 (IQR 0.5), p < 0.05 for all comparisons] than those that resulted from low eccentricity impacts. The developed classification functions had 92 % classification accuracy. CONCLUSIONS: Dynamic axial compression loading of the cervical spine with high lateral eccentricities produced primarily soft tissue injuries resulting in more post-injury spinal flexibility in lateral bending and axial rotation than that associated with the bony fractures resulting from low eccentricity impacts.


Asunto(s)
Vértebras Cervicales/lesiones , Vértebras Cervicales/fisiopatología , Anciano , Cadáver , Análisis Discriminante , Humanos , Rango del Movimiento Articular/fisiología , Traumatismos de los Tejidos Blandos/fisiopatología , Fracturas de la Columna Vertebral/fisiopatología , Soporte de Peso/fisiología
6.
Eur Spine J ; 24(4): 775-82, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25559294

RESUMEN

PURPOSE: Dynamic implants have been developed to address potential adjacent level effects due to rigid instrumentation. Rates of revision surgeries may be reduced by using improved implants in the primary surgery. Prior to clinical use, implants should be rigorously tested ex vivo. The objective of our study was to characterize the load-sharing and kinematic behavior of a novel low-stiffness spinal implant. METHODS: A human cadaveric model of degenerative spondylolisthesis was tested in shear. Lumbar functional spinal units (N = 15) were tested under a static 300 N axial compression force and a cyclic anterior shear force (5-250 N). Translation was tracked with a motion capture system. A novel implant was compared to three standard implants with shear stiffness ranging from low to high. All implants were instrumented with strain gauges to measure the supported shear force. Each implant was affixed to each specimen, and the specimens were tested intact and in two progressively destabilized states. RESULTS: Specimen condition and implant type affected implant load-sharing and specimen translation (p < 0.0001). Implant load-sharing increased across all degeneration-simulating specimen conditions and decreased across the three standard implants (high- to low-stiffness). Translation increased with the three standard implants (trend). The novel implant behaved similarly to the medium-stiffness implant (p > 0.2). CONCLUSIONS: The novel implant behaved similarly to the medium-stiffness implant in both load-sharing and translation despite having a different design and stiffness. Complex implant design and specimen-implant interaction necessitate pre-clinical testing of novel implants. Further in vitro testing in axial rotation and flexion-extension is recommended as they are highly relevant loading directions for non-rigid implants.


Asunto(s)
Vértebras Lumbares/cirugía , Prótesis e Implantes , Rango del Movimiento Articular/fisiología , Espondilolistesis/cirugía , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Teóricos , Diseño de Prótesis , Soporte de Peso
7.
BMC Musculoskelet Disord ; 16: 112, 2015 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-25958203

RESUMEN

BACKGROUND: Proximal humerus fractures are a common fragility fracture that significantly affects the independence of older adults. The outcomes of these fractures are frequently disappointing and previous systematic reviews are unable to guide clinical practice. Through an integrated knowledge user collaboration, we sought to map the breadth of literature available to guide the management of proximal humerus fractures. METHODS: We utilized a scoping review technique because of its novel ability to map research activity and identify knowledge gaps in fields with diverse treatments. Through multiple electronic database searches, we identified a comprehensive body of proximal humerus fracture literature that was classified into eight research themes. Meta-data from each study were abstracted and descriptive statistics were used to summarize the results. RESULTS: 1,051 studies met our inclusion criteria with the majority of research being performed in Europe (64%). The included literature consists primarily of surgical treatment studies (67%) and biomechanical fracture models (10%). Nearly half of all clinical studies are uncontrolled case series of a single treatment (48%). Non-randomized comparative studies represented 12% of the literature and only 3% of the studies were randomized controlled trials. Finally, studies with a primary outcome examining the effectiveness of non-operative treatment or using a prognostic study design were also uncommon (4% and 6%, respectively). CONCLUSIONS: The current study provides a comprehensive summary of the existing proximal humerus fracture literature using a thematic framework developed by a multi-disciplinary collaboration. Several knowledge gaps have been identified and have generated a roadmap for future research priorities.


Asunto(s)
Investigación Biomédica , Húmero , Ortopedia , Fracturas del Hombro , Factores de Edad , Anciano , Anciano de 80 o más Años , Bibliometría , Fenómenos Biomecánicos , Curación de Fractura , Anciano Frágil , Humanos , Húmero/fisiopatología , Húmero/cirugía , Bases del Conocimiento , Persona de Mediana Edad , Factores de Riesgo , Fracturas del Hombro/diagnóstico , Fracturas del Hombro/epidemiología , Fracturas del Hombro/fisiopatología , Fracturas del Hombro/cirugía , Resultado del Tratamiento
8.
BMC Musculoskelet Disord ; 16: 175, 2015 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-26223275

RESUMEN

BACKGROUND: Fixation failure is a relatively common sequela of surgical management of proximal humerus fractures (PHF). The purpose of this study is to understand the current state of the literature with regard to the biomechanical testing of proximal humerus fracture implants. METHODS: A scoping review of the proximal humerus fracture literature was performed, and studies testing the mechanical properties of a PHF treatment were included in this review. Descriptive statistics were used to summarize the characteristics and methods of the included studies. RESULTS: 1,051 proximal humerus fracture studies were reviewed; 67 studies met our inclusion criteria. The most common specimen used was cadaver bone (87%), followed by sawbones (7%) and animal bones (4%). A two-part fracture pattern was tested most frequently (68%), followed by three-part (23%), and four-part (8%). Implants tested included locking plates (52%), intramedullary devices (25%), and non-locking plates (25%). Hemi-arthroplasty was tested in 5 studies (7%), with no studies using reverse total shoulder arthroplasty (RTSA) implants. Torque was the most common mode of force applied (51%), followed by axial loading (45%), and cantilever bending (34%). Substantial testing diversity was observed across all studies. CONCLUSIONS: The biomechanical literature was found to be both diverse and heterogeneous. More complex fracture patterns and RTSA implants have not been adequately tested. These gaps in the current literature will need to be addressed to ensure that future biomechanical research is clinically relevant and capable of improving the outcomes of challenging proximal humerus fracture patterns.


Asunto(s)
Análisis de Falla de Equipo/métodos , Fijación Interna de Fracturas/métodos , Falla de Prótesis , Fracturas del Hombro/cirugía , Animales , Fenómenos Biomecánicos/fisiología , Análisis de Falla de Equipo/normas , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/normas , Humanos , Falla de Prótesis/efectos adversos , Fracturas del Hombro/diagnóstico
10.
BMC Public Health ; 14: 1205, 2014 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-25416928

RESUMEN

BACKGROUND: Widely varying crash circumstances have been reported for bicycling injuries, likely because of differing bicycling populations and environments. We used data from the Bicyclists' Injuries and the Cycling Environment Study in Vancouver and Toronto, Canada, to describe the crash circumstances of people injured while cycling for utilitarian and leisure purposes. We examined the association of crash circumstances with route type. METHODS: Adult cyclists injured and treated in a hospital emergency department described their crash circumstances. These were classified into major categories (collision vs. fall, motor vehicle involved vs. not) and subcategories. The distribution of circumstances was tallied for each of 14 route types defined in an earlier analysis. Ratios of observed vs. expected were tallied for each circumstance and route type combination. RESULTS: Of 690 crashes, 683 could be characterized for this analysis. Most (74%) were collisions. Collisions included those with motor vehicles (34%), streetcar (tram) or train tracks (14%), other surface features (10%), infrastructure (10%), and pedestrians, cyclists, or animals (6%). The remainder of the crashes were falls (26%), many as a result of collision avoidance manoeuvres. Motor vehicles were involved directly or indirectly with 48% of crashes. Crash circumstances were distributed differently by route type, for example, collisions with motor vehicles, including "doorings", were overrepresented on major streets with parked cars. Collisions involving streetcar tracks were overrepresented on major streets. Collisions involving infrastructure (curbs, posts, bollards, street furniture) were overrepresented on multiuse paths and bike paths. CONCLUSIONS: These data supplement our previous analyses of relative risks by route type by indicating the types of crashes that occur on each route type. This information can guide municipal engineers and planners towards improvements that would make cycling safer.


Asunto(s)
Accidentes de Tránsito/estadística & datos numéricos , Ciclismo/lesiones , Planificación Ambiental/estadística & datos numéricos , Características de la Residencia , Seguridad/estadística & datos numéricos , Adulto , Ciclismo/estadística & datos numéricos , Estudios Transversales , Humanos , Masculino , Ontario/epidemiología , Riesgo , Medición de Riesgo
11.
J Biomech Eng ; 136(12): 124505, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25322158

RESUMEN

The tolerance of the spine to bending moments, used for evaluation of injury prevention devices, is often determined through eccentric axial compression experiments using segments of the cadaver spine. Preliminary experiments in our laboratory demonstrated that eccentric axial compression resulted in "unexpected" (artifact) moments. The aim of this study was to evaluate the static and dynamic effects of test configuration on bending moments during eccentric axial compression typical in cadaver spine segment testing. Specific objectives were to create dynamic equilibrium equations for the loads measured inferior to the specimen, experimentally verify these equations, and compare moment responses from various test configurations using synthetic (rubber) and human cadaver specimens. The equilibrium equations were verified by performing quasi-static (5 mm/s) and dynamic experiments (0.4 m/s) on a rubber specimen and comparing calculated shear forces and bending moments to those measured using a six-axis load cell. Moment responses were compared for hinge joint, linear slider and hinge joint, and roller joint configurations tested at quasi-static and dynamic rates. Calculated shear force and bending moment curves had similar shapes to those measured. Calculated values in the first local minima differed from those measured by 3% and 15%, respectively, in the dynamic test, and these occurred within 1.5 ms of those measured. In the rubber specimen experiments, for the hinge joint (translation constrained), quasi-static and dynamic posterior eccentric compression resulted in flexion (unexpected) moments. For the slider and hinge joints and the roller joints (translation unconstrained), extension ("expected") moments were measured quasi-statically and initial flexion (unexpected) moments were measured dynamically. In the cadaver experiments with roller joints, anterior and posterior eccentricities resulted in extension moments, which were unexpected and expected, for those configurations, respectively. The unexpected moments were due to the inertia of the superior mounting structures. This study has shown that eccentric axial compression produces unexpected moments due to translation constraints at all loading rates and due to the inertia of the superior mounting structures in dynamic experiments. It may be incorrect to assume that bending moments are equal to the product of compression force and eccentricity, particularly where the test configuration involves translational constraints and where the experiments are dynamic. In order to reduce inertial moment artifacts, the mass, and moment of inertia of any loading jig structures that rotate with the specimen should be minimized. Also, the distance between these structures and the load cell should be reduced.


Asunto(s)
Artefactos , Fuerza Compresiva , Ensayo de Materiales/métodos , Columna Vertebral/fisiología , Soporte de Peso , Femenino , Humanos , Masculino
12.
Inj Epidemiol ; 11(1): 30, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38961502

RESUMEN

BACKGROUND: Rollover crashes continue to be a substantial public health issue in North America. Previous research has shown that the cervical spine is the most injured spine segment in rollovers, but much of the past research has focused on risk factors rather than the actual cervical spine injuries. We sought to examine how different types of cervical spine injuries (vertebral and/or cord injury) vary with different occupant-related factors in rollovers and to compare these with non-rollovers. METHODS: We obtained crash and injury information from the National Automotive Sampling System-Crashworthiness Data System (NASS-CDS) for 2005-2015 and Crash Investigation Sampling System (CISS) for 2017-2022. Based on weighted data, we calculated relative risks to assess how occupant sex, seat belt use, ejection status, and fatal outcome relate to the rate of different cervical spine injuries in rollovers and non-rollovers. RESULTS: In NASS-CDS occupants with cervical spine injuries (N = 111,040 weighted cases), about 91.5% experienced at least one vertebral injury whereas only 11.3% experienced a spinal cord injury (most of which had a concomitant vertebral fracture). All types of cervical spine injuries we examined were 3.4-5.2 times more likely to occur in rollovers compared to non-rollovers. These relative risks were similar for both sexes, belted and unbelted, non-ejected, and non-fatal occupants. The number of weighted CISS occupants with cervical spine injuries (N = 42,003) was smaller than in the NASS analysis, but cervical spine injuries remained 6.25 to 6.36 times more likely in rollovers compared to non-rollovers despite a more modern vehicle fleet. CONCLUSIONS: These findings underscore the continued need for rollover-specific safety countermeasures, especially those focused on cervical spine injury prevention, and elucidate the frequency, severity and other characteristics of the specific vertebral and spinal cord injuries being sustained in rollovers. Our findings suggest that countermeasures focused on preventing cervical vertebral fractures will also effectively prevent most cervical spinal cord injuries.

13.
JOR Spine ; 7(3): e1360, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39071861

RESUMEN

Background: Facet fractures are frequently associated with clinically observed cervical facet dislocations (CFDs); however, to date there has only been one experimental study, using functional spinal units (FSUs), which has systematically produced CFD with concomitant facet fracture. The role of axial compression and distraction on the mechanical response of the cervical facets under intervertebral motions associated with CFD in FSUs has previously been shown. The same has not been demonstrated in multi-segment lower cervical spine specimens under flexion loading (postulated to be the local injury vector associated with CFD). Methods: This study investigated the mechanical response of the bilateral inferior C6 facets of thirteen C5-C7 specimens (67±13 yr, 6 male) during non-destructive constrained flexion, superimposed with each of five axial conditions: (1) 50 N compression (simulating weight of the head); (2-4) 300, 500, and 1000 N compression (simulating the spectrum of intervertebral compression resulting from neck muscle bracing prior to head-first impact and/or externally applied compressive forces); and, (5) 2 mm of C6/C7 distraction (simulating the intervertebral distraction present during inertial loading of the cervical spine by the weight of the head). Linear mixed-effects models (α = 0.05) assessed the effect of axial condition. Results: Increasing amounts of intervertebral compression superimposed on flexion rotations, resulted in increased facet surface strains (range of estimated mean difference relative to Neutral: maximum principal = 77 to 110 µÎµ, minimum principal = 126 to 293 µÎµ, maximum shear = 203 to 375 µÎµ) and angular deflection of the bilateral inferior C6 facets relative to the C6 vertebral body (range of estimated mean difference relative to Neutral = 0.59° to 1.47°). Conclusions: These findings suggest increased facet engagement and higher load transfer through the facet joint, and potentially a higher likelihood of facet fracture under the compressed axial conditions.

14.
Inj Prev ; 19(5): 303-10, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23411678

RESUMEN

BACKGROUND: This study examined the impact of transportation infrastructure at intersection and non-intersection locations on bicycling injury risk. METHODS: In Vancouver and Toronto, we studied adult cyclists who were injured and treated at a hospital emergency department. A case-crossover design compared the infrastructure of injury and control sites within each injured bicyclist's route. Intersection injury sites (N=210) were compared to randomly selected intersection control sites (N=272). Non-intersection injury sites (N=478) were compared to randomly selected non-intersection control sites (N=801). RESULTS: At intersections, the types of routes meeting and the intersection design influenced safety. Intersections of two local streets (no demarcated traffic lanes) had approximately one-fifth the risk (adjusted OR 0.19, 95% CI 0.05 to 0.66) of intersections of two major streets (more than two traffic lanes). Motor vehicle speeds less than 30 km/h also reduced risk (adjusted OR 0.52, 95% CI 0.29 to 0.92). Traffic circles (small roundabouts) on local streets increased the risk of these otherwise safe intersections (adjusted OR 7.98, 95% CI 1.79 to 35.6). At non-intersection locations, very low risks were found for cycle tracks (bike lanes physically separated from motor vehicle traffic; adjusted OR 0.05, 95% CI 0.01 to 0.59) and local streets with diverters that reduce motor vehicle traffic (adjusted OR 0.04, 95% CI 0.003 to 0.60). Downhill grades increased risks at both intersections and non-intersections. CONCLUSIONS: These results provide guidance for transportation planners and engineers: at local street intersections, traditional stops are safer than traffic circles, and at non-intersections, cycle tracks alongside major streets and traffic diversion from local streets are safer than no bicycle infrastructure.


Asunto(s)
Accidentes de Tránsito/estadística & datos numéricos , Ciclismo/lesiones , Planificación Ambiental , Administración de la Seguridad/métodos , Accidentes de Tránsito/prevención & control , Adulto , Colombia Británica , Estudios de Casos y Controles , Estudios Cruzados , Femenino , Humanos , Modelos Logísticos , Masculino , Ontario
15.
J Biomech Eng ; 135(12): 121001, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24026221

RESUMEN

A new method for laboratory testing of human proximal femora in conditions simulating a sideways fall was developed. Additionally, in order to analyze the strain state in future cadaveric tests, digital image correlation (DIC) was validated as a tool for strain field measurement on the bone of the femoral neck. A fall simulator which included models for the body mass, combined lateral femur and pelvis mass, pelvis stiffness, and trochanteric soft tissue was designed. The characteristics of each element were derived and developed based on human data from the literature. The simulator was verified by loading a state-of-the-art surrogate femur and comparing the resulting force-time trace to published, human volunteer experiments. To validate the DIC, 20 human proximal femora were prepared with a strain rosette and speckle paint pattern, and loaded to 50% of their predicted failure load at a low compression rate. Strain rosettes were taken as the gold standard, and minimum principal strains from the DIC and the rosettes were compared using descriptive statistics. The initial slope of the force-time curve obtained in the fall simulator matched published human volunteer data, with local peaks superimposed in the model due to internal vibrations of the spring used to model the pelvis stiffness. Global force magnitude and temporal characteristics were within 2% of published volunteer experiments. The DIC minimum principal strains were found to be accurate to 127±239 µÉ›. These tools will allow more biofidelic laboratory simulation of falls to the side, and more detailed analysis of proximal femur failure mechanisms using human cadaver specimens.


Asunto(s)
Accidentes por Caídas , Fracturas del Fémur , Fenómenos Mecánicos , Modelos Biológicos , Fenómenos Biomecánicos , Humanos , Ensayo de Materiales
16.
J Biomech Eng ; 135(10): 101005, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23897000

RESUMEN

Despite considerable effort over the last four decades, research has failed to translate into consistently effective treatment options for spinal cord injury (SCI). This is partly attributed to differences between the injury response of humans and rodent models. Some of this difference could be because the cerebrospinal fluid (CSF) layer of the human spine is relatively large, while that of the rodents is extremely thin. We sought to characterize the fluid impulse induced in the CSF by experimental SCIs of moderate and high human-like severity, and to compare this with previous studies in which fluid impulse has been associated with neural tissue injury. We used a new in vivo pig model (n = 6 per injury group, mean age 124.5 days, 20.9 kg) incorporating four miniature pressure transducers that were implanted in pairs in the subarachnoid space, cranial, and caudal to the injury at 30 mm and 100 mm. Tissue sparing was assessed with Eriochrome Cyanine and Neutral Red staining. The median peak pressures near the injury were 522.5 and 868.8 mmHg (range 96.7-1430.0) and far from the injury were 7.6 and 36.3 mmHg (range 3.8-83.7), for the moderate and high injury severities, respectively. Pressure impulse (mmHg.ms), apparent wave speed, and apparent attenuation factor were also evaluated. The data indicates that the fluid pressure wave may be sufficient to affect the severity and extent of primary tissue damage close to the injury site. However, the CSF pressure was close to normal physiologic values at 100 mm from the injury. The high injury severity animals had less tissue sparing than the moderate injury severity animals; this difference was statistically significant only within 1.6 mm of the epicenter. These results indicate that future research seeking to elucidate the mechanical origins of primary tissue damage in SCI should consider the effects of CSF. This pig model provides advantages for basic and preclinical SCI research due to its similarities to human scale, including the existence of a human-like CSF fluid layer.


Asunto(s)
Traumatismos de la Médula Espinal/complicaciones , Traumatismos de la Médula Espinal/fisiopatología , Animales , Presión del Líquido Cefalorraquídeo , Modelos Animales de Enfermedad , Femenino , Traumatismos de la Médula Espinal/patología , Porcinos
17.
J Biomech Eng ; 135(11): 111003, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23775333

RESUMEN

Current understanding of the biomechanics of cervical spine injuries in head-first impact is based on decades of epidemiology, mathematical models, and in vitro experimental studies. Recent mathematical modeling suggests that muscle activation and muscle forces influence injury risk and mechanics in head-first impact. It is also known that muscle forces are central to the overall physiologic stability of the cervical spine. Despite this knowledge, the vast majority of in vitro head-first impact models do not incorporate musculature. We hypothesize that the simulation of the stabilizing mechanisms of musculature during head-first osteoligamentous cervical spine experiments will influence the resulting kinematics and injury mechanisms. Therefore, the objective of this study was to document differences in the kinematics, kinetics, and injuries of ex vivo osteoligamentous human cervical spine and surrogate head complexes that were instrumented with simulated musculature relative to specimens that were not instrumented with musculature. We simulated a head-first impact (3 m/s impact speed) using cervical spines and surrogate head specimens (n = 12). Six spines were instrumented with a follower load to simulate in vivo compressive muscle forces, while six were not. The principal finding was that the axial coupling of the cervical column between the head and the base of the cervical spine (T1) was increased in specimens with follower load. Increased axial coupling was indicated by a significantly reduced time between head impact and peak neck reaction force (p = 0.004) (and time to injury (p = 0.009)) in complexes with follower load relative to complexes without follower load. Kinematic reconstruction of vertebral motions indicated that all specimens experienced hyperextension and the spectrum of injuries in all specimens were consistent with a primary hyperextension injury mechanism. These preliminary results suggest that simulating follower load that may be similar to in vivo muscle forces results in significantly different impact kinetics than in similar biomechanical tests where musculature is not simulated.


Asunto(s)
Vértebras Cervicales/lesiones , Fuerza Compresiva , Cabeza , Modelos Biológicos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Humanos , Cinética , Masculino , Factores de Tiempo
18.
Ann Biomed Eng ; 51(11): 2544-2553, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37358713

RESUMEN

Porcine models in injury biomechanics research often involve measuring head or brain kinematics. Translation of data from porcine models to other biomechanical models requires geometric and inertial properties of the pig head and brain, and a translationally relevant anatomical coordinate system (ACS). In this study, the head and brain mass, center of mass (CoM), and mass moments of inertia (MoI) were characterized, and an ACS was proposed for the pre-adolescent domestic pig. Density-calibrated computed tomography scans were obtained for the heads of eleven Large White × Landrace pigs (18-48 kg) and were segmented. An ACS with a porcine-equivalent Frankfort plane was defined using externally palpable landmarks (right/left frontal process of the zygomatic bone and zygomatic process of the frontal bone). The head and brain constituted 7.80 ± 0.79% and 0.33 ± 0.08% of the body mass, respectively. The head and brain CoMs were primarily ventral and caudal to the ACS origin, respectively. The mean head and brain principal MoI (in the ACS with origin at respective CoM) ranged from 61.7 to 109.7 kg cm2, and 0.2 to 0.6 kg cm2, respectively. These data may aid the comparison of head and brain kinematics/kinetics data and the translation between porcine and human injury models.


Asunto(s)
Encéfalo , Cabeza , Adolescente , Humanos , Porcinos , Animales , Cabeza/diagnóstico por imagen , Fenómenos Biomecánicos , Encéfalo/diagnóstico por imagen , Cráneo , Tomografía Computarizada por Rayos X
19.
J Orthop Res ; 41(9): 1855-1862, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37249119

RESUMEN

Various femoral augmentation designs have been investigated over the past decade for the prevention of geriatric hip fracture. The experimental methods used to evaluate the efficacy of these augmentations have not been critically evaluated or compared in terms of biofidelity, robustness, or ease of application. Such parameters have significant relevance in characterizing future clinical success. In this study we aimed to use a scoping review to summarize the experimental studies that evaluate femoral augmentation approaches, and critically evaluate commonly applied protocols and identify areas for concordance with the clinical situation. We conducted a literature search targeting studies that used experimental test methods to evaluate femoral augmentation to prevent geriatric fragility fracture. A total of 25 studies met the eligibility criteria. The most commonly investigated augmentation to date is the injection of bone cement or another material that cured in situ, and a popular subsequent method for biomechanical evaluation was to load the augmented proximal femur until fracture in a sideways fall configuration. We noted limitations in the clinical relevance of sideways fall scenarios being modeled and large variance in the concordance of many of the studies identified. Our review brings about recommendations for enhancing the fidelity of experimental methods modeling clinical sideways falls, which include an improved representation of soft tissue effects, using outcome metrics beyond load-to-failure, and applying loads inertially. Effective augmentations are encouraging for their potential to reduce the burden of hip fracture; however, the likelihood of this success is only as strong as the methods used in their evaluation.


Asunto(s)
Fracturas de Cadera , Huesos Pélvicos , Humanos , Anciano , Fémur , Fracturas de Cadera/prevención & control , Fracturas de Cadera/cirugía , Cementos para Huesos/uso terapéutico , Fenómenos Biomecánicos
20.
Front Bioeng Biotechnol ; 11: 1079644, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36777252

RESUMEN

Femoral fractures due to sideways falls continue to be a major cause of concern for the elderly. Existing approaches for the prevention of these injuries have limited efficacy. Prophylactic femoral augmentation systems, particularly those involving the injection of ceramic-based bone cements, are gaining more attention as a potential alternative preventative approach. We evaluated the mechanical effectiveness of three variations of a bone cement injection pattern (basic ellipsoid, hollow ellipsoid, small ellipsoid) utilizing finite element simulations of sideways fall impacts. The basic augmentation pattern was tested with both high- and low-strength ceramic-based cements. The cement patterns were added to the finite element models (FEMs) of five cadaveric femurs, which were then subject to simulated sideways falls at seven impact velocities ranging from 1.0 m/s to 4.0 m/s. Peak impact forces and peak acetabular forces were examined, and failure was evaluated using a strain-based criterion. We found that the basic HA ellipsoid provided the highest increases in both the force at the acetabulum of the impacted femur ("acetabular force", 55.0% ± 22.0%) and at the force plate ("impact force", 37.4% ± 15.8%). Changing the cement to a weaker material, brushite, resulted in reduced strengthening of the femur (45.2% ± 19.4% acetabular and 30.4% ± 13.0% impact). Using a hollow version of the ellipsoid appeared to have no effect on the fracture outcome and only a minor effect on the other metrics (54.1% ± 22.3% acetabular force increase and 35.3% ± 16.0% impact force increase). However, when the outer two layers of the ellipsoid were removed (small ellipsoid), the force increases that were achieved were only 9.8% ± 5.5% acetabular force and 8.2% ± 4.1% impact force. These results demonstrate the importance of supporting the femoral neck cortex to prevent femoral fractures in a sideways fall, and provide plausible options for prophylactic femoral augmentation. As this is a preliminary study, the surgical technique, the possible effects of trabecular bone damage during the augmentation process, and the effect on the blood supply to the femoral head must be assessed further.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA