Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Opt Express ; 30(18): 31550-31566, 2022 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-36242235

RESUMEN

Turbid media, made of wavelength-scale inhomogeneous particles, can give rise to many significant imaging and spectroscopy challenges. The random variation of the refractive index within such media distorts the spherical wavefronts, resulting in smeared and speckly images. The scattering-induced artifacts can obscure the characteristic spectral fingerprints of the chemicals in a sample. This in turn prevents accurate chemical imaging and characterization of the materials cloaked with a diffusive medium. In this work, we present a novel computational technique for creating spatially- and spectrally-resolved chemical maps through a diffusive cloak using terahertz time-domain spectroscopy. We use the maximal overlap discrete wavelet transform to obtain a multiresolution spectral decomposition of THz extinction coefficients. We define a new spectroscopic concept dubbed the "bimodality coefficient spectrum" using the skewness and kurtosis of the spectral images. We demonstrate that broadband wavelet-based reconstruction of the bimodality coefficient spectrum can resolve the signature resonant frequencies through the scattering layers. Additionally, we show that our approach can achieve spectral images with diffraction-limited resolution. This technique can be used for stand-off characterization of materials and spectral imaging in nondestructive testing and biological applications.

2.
Sensors (Basel) ; 22(6)2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35336476

RESUMEN

Wavelet transform is an important tool in the computational signal processing of terahertz time-domain spectroscopy (THz-TDS) measurements. Despite its prevalence, the effects of using different forms of wavelet transforms in THz-TDS studies have not been investigated. In this paper, we explore the implications of using the maximal overlap discrete wavelet transform (MODWT) versus the well-known discrete wavelet transform (DWT). We demonstrate that the spectroscopic features extracted using DWT can vary over different overlapping frequency ranges. On the contrary, MODWT is translation-invariant and results in identical features, regardless of the spectral range used for its implementation.We also demonstrate that the details coefficients obtained by the multiresolution analysis (MRA) using MODWT are associated with zero-phase filters. In contrast, DWT details coefficients suffer from misalignments originated from the down- and upsampling operations in DWT pyramid algorithm. Such misalignments have adverse effects when it is critical to retain the exact location of the absorption lines. We study the differences of DWT and MODWT both analytically and experimentally, using reflection THz-TDS measurements of α-lactose monohydrate. This manuscript can guide the researchers to select the right wavelet analysis tool for their specific application of the THz spectroscopy.


Asunto(s)
Espectroscopía de Terahertz , Análisis de Ondículas , Algoritmos , Procesamiento de Señales Asistido por Computador
3.
Opt Express ; 28(18): 26612-26622, 2020 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-32906931

RESUMEN

We report on the development and performance characterization of a telecentric terahertz spectroscopic scanner using an f-θ objective lens and a single gimballed scanning mirror for image formation. We derived a beam steering transform to compensate for the intercoupling of the gimballed mirror axes and the distortions caused by an imperfect scanning lens. We characterize the optical performance of the system in both the time and spatial domains, demonstrating a constant diffraction-limited imaging resolution over the entire field of view. Finally, given the large depth of focus of the objective lens, we demonstrate the broadband imaging capability at different depths using a Boehler star target. This imaging setup has the potential to be miniaturized into portable form factors for field-deployable scenarios.

4.
Wound Repair Regen ; 28(6): 789-796, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32729128

RESUMEN

Whether the depth and healing of scalds and contact burns are similar is controversial. Due to water's greater heat capacity, we hypothesized that when exposed to similar temperatures and durations of exposure, burns caused by hot water would be deeper than those caused by contact with hot metal. Forty standardized burns were created in two anesthetized female domestic pigs using a brass bar or circulating heated water. In one pig, the temperature was kept constant (95°C) while the duration of exposure varied (5, 10, 15 seconds) In the second pig, the exposure time was kept constant (10 seconds) while the temperature of exposure varied (70°C, 80°C, 98°C). Periodic punch biopsies were taken to determine burn depth immediately after injury, percentage burns reepithelialized within 21 days, and depth of scar at 28 days. The analysis was performed using analysis of variance. When the temperature was held constant, duration of exposure (5, 10, and 15 seconds) was associated with scar depth (2.1 vs 3.8 vs 5.0 mm, respectively, P = 0.001) but not with burn depth (2.0 vs 2.2 vs 2.3 mm, respectively, P = 0.10). When exposure duration was held constant, temperature (70°C, 80°C, 98°C) was associated with scar depth (0.6 vs 1.7 vs 3.6, P < 0.001) but not with burn depth (1.2 vs 1.5 vs 1.7 mm, respectively, P = 0.21). Burn depths were greater for scald than contact burns although not significantly greater. After controlling for temperature, the difference in scar depth between scalds and contact burns was statistically significant (marginal means 3.0 for contact burns, 4.3 for scalds, P = 0.008). We conclude that burns created in swine with circulating hot water result in deeper scars than those created by contact with a brass bar when controlling for temperature and duration of exposure.


Asunto(s)
Quemaduras/diagnóstico , Cicatriz/diagnóstico , Repitelización/fisiología , Piel/lesiones , Cicatrización de Heridas/fisiología , Animales , Biopsia , Quemaduras/complicaciones , Cicatriz/etiología , Modelos Animales de Enfermedad , Femenino , Calor/efectos adversos , Estudios Prospectivos , Piel/patología , Porcinos , Índices de Gravedad del Trauma
5.
Biomed Opt Express ; 14(2): 918-931, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36874480

RESUMEN

The initial assessment of the depth of a burn injury during triage forms the basis for determination of the course of the clinical treatment plan. However, severe skin burns are highly dynamic and hard to predict. This results in a low accuracy rate of about 60 - 75% in the diagnosis of partial-thickness burns in the acute post-burn period. Terahertz time-domain spectroscopy (THz-TDS) has demonstrated a significant potential for non-invasive and timely estimation of the burn severity. Here, we describe a methodology for the measurement and numerical modeling of the dielectric permittivity of the in vivo porcine skin burns. We use the double Debye dielectric relaxation theory to model the permittivity of the burned tissue. We further investigate the origins of dielectric contrast between the burns of various severity, as determined histologically based on the percentage of the burned dermis, using the empirical Debye parameters. We demonstrate that the five parameters of the double Debye model can form an artificial neural network classification algorithm capable of automatic diagnosis of the severity of the burn injuries, and predicting its ultimate wound healing outcome by forecasting its re-epithelialization status in 28 days. Our results demonstrate that the Debye dielectric parameters provide a physics-based approach for the extraction of the biomedical diagnostic markers from the broadband THz pulses. This method can significantly boost dimensionality reduction of THz training data in artificial intelligence models and streamline machine learning algorithms.

6.
Biomed Opt Express ; 13(4): 1855-1868, 2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35519269

RESUMEN

Thermal injuries can occur due to direct exposure to hot objects or liquids, flames, electricity, solar energy and several other sources. If the resulting injury is a deep partial thickness burn, the accuracy of a physician's clinical assessment is as low as 50-76% in determining the healing outcome. In this study, we show that the Terahertz Portable Handheld Spectral Reflection (THz-PHASR) Scanner combined with a deep neural network classification algorithm can accurately differentiate between partial-, deep partial-, and full-thickness burns 1-hour post injury, regardless of the etiology, scanner geometry, or THz spectroscopy sampling method (ROC-AUC = 91%, 88%, and 86%, respectively). The neural network diagnostic method simplifies the classification process by directly using the pre-processed THz spectra and removing the need for any hyperspectral feature extraction. Our results show that deep learning methods based on THz time-domain spectroscopy (THz-TDS) measurements can be used to guide clinical treatment plans based on objective and accurate classification of burn injuries.

7.
J Biomed Opt ; 27(11)2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36348509

RESUMEN

Significance: Severe burn injuries cause significant hypermetabolic alterations that are highly dynamic, hard to predict, and require acute and critical care. The clinical assessments of the severity of burn injuries are highly subjective and have consistently been reported to be inaccurate. Therefore, the utilization of other imaging modalities is crucial to reaching an objective and accurate burn assessment modality. Aim: We describe a non-invasive technique using terahertz time-domain spectroscopy (THz-TDS) and the wavelet packet Shannon entropy to automatically estimate the burn depth and predict the wound healing outcome of thermal burn injuries. Approach: We created 40 burn injuries of different severity grades in two porcine models using scald and contact methods of infliction. We used our THz portable handheld spectral reflection (PHASR) scanner to obtain the in vivo THz-TDS images. We used the energy to Shannon entropy ratio of the wavelet packet coefficients of the THz-TDS waveforms on day 0 to create supervised support vector machine (SVM) classification models. Histological assessments of the burn biopsies serve as the ground truth. Results: We achieved an accuracy rate of 94.7% in predicting the wound healing outcome, as determined by histological measurement of the re-epithelialization rate on day 28 post-burn induction, using the THz-TDS measurements obtained on day 0. Furthermore, we report the accuracy rates of 89%, 87.1%, and 87.6% in automatic diagnosis of the superficial partial-thickness, deep partial-thickness, and full-thickness burns, respectively, using a multiclass SVM model. Conclusions: The THz PHASR scanner promises a robust, high-speed, and accurate diagnostic modality to improve the clinical triage of burns and their management.


Asunto(s)
Piel , Espectroscopía de Terahertz , Animales , Piel/patología , Máquina de Vectores de Soporte , Porcinos , Cicatrización de Heridas
8.
Sci Rep ; 12(1): 5096, 2022 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-35332207

RESUMEN

We present an automatic classification strategy for early and accurate assessment of burn injuries using terahertz (THz) time-domain spectroscopic imaging. Burn injuries of different severity grades, representing superficial partial-thickness (SPT), deep partial-thickness (DPT), and full-thickness (FT) wounds, were created by a standardized porcine scald model. THz spectroscopic imaging was performed using our new fiber-coupled Portable HAndheld Spectral Reflection Scanner, incorporating a telecentric beam steering configuration and an f-[Formula: see text] scanning lens. ASynchronous Optical Sampling in a dual-fiber-laser THz spectrometer with 100 MHz repetition rate enabled high-speed spectroscopic measurements. Given twenty-four different samples composed of ten scald and ten contact burns and four healthy samples, supervised machine learning algorithms using THz-TDS spectra achieved areas under the receiver operating characteristic curves of 0.88, 0.93, and 0.93 when differentiating between SPT, DPT, and FT burns, respectively, as determined by independent histological assessments. These results show the potential utility of our new broadband THz PHASR Scanner for early and accurate triage of burn injuries.


Asunto(s)
Quemaduras , Imágen por Terahertz , Espectroscopía de Terahertz , Algoritmos , Animales , Quemaduras/diagnóstico por imagen , Aprendizaje Automático Supervisado , Porcinos
9.
Adv Photonics Res ; 3(5)2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-36589697

RESUMEN

The accuracy of clinical assessment techniques in diagnosing partial-thickness burn injuries has remained as low as 50-76%. Depending on the burn depth and environmental factors in the wound, such as reactive oxygen species, inflammation, and autophagy, partial-thickness burns can heal spontaneously or require surgical intervention. Herein, it is demonstrated that terahertz time-domain spectral imaging (THz-TDSI) is a promising tool for in vivo quantitative assessment and monitoring of partial-thickness burn injuries in large animals. We used a novel handheld THz-TDSI scanner to characterize burn injuries in a porcine scald model with histopathological controls. Statistical analysis (n= 40) indicates that the THz-TDSI modality can accurately differentiate between partial-thickness and full-thickness burn injuries (1-way ANOVA, p< 0.05). THz-TDSI has the potential to improve burn care outcomes by helping surgeons in making objective decisions for early excision of the wound.

10.
IEEE Access ; 9: 29746-29754, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-35433152

RESUMEN

We present the development and implementation of a novel wavelet shrinkage technique for the retrieval of obscured characteristic resonant signatures in the scattered terahertz (THz) reflectivity of molecular crystals. In this implementation, the wavelet basis functions associated with the absorption features were identified using the second-order total variation of the wavelet coefficients. Additionally, wavelet coefficients at certain scales were modified using the phase function corrections and wavelet hard thresholding. Reconstruction of the original spectra using these modified wavelet coefficients yielded the exact resonant frequencies of the chemicals, which were otherwise unrecognizable in the spectral artifacts of the rough surface scattering. We examined the robustness of this method over controlled levels of rough surface scattering, validated using the Kirchhoff approximation, in spectroscopic targets made from α-lactose monohydrate and 4-aminobenzoic acid (PABA), which have close spectral lines. We successfully retrieved the spectral absorption fingerprints in both specular and off-specular reflection geometries. This technique can be utilized for stand-off material characterization using the THz reflection spectroscopy in uncontrolled environments and potentially can be adopted for other broadband spectroscopic modalities.

11.
Sci Rep ; 11(1): 22804, 2021 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-34815438

RESUMEN

Current terahertz (THz) spectroscopy techniques only use the coherent light beam for spectral imaging. In the presence of electromagnetic scattering, however, the scattering-mitigated incoherent beams allow for flexible emitter-detector geometries, which enable applications such as seeing through turbid media. Despite this potential, THz spectroscopy using diffuse waves has not been demonstrated. The main obstacles are the very poor signal to noise ratios of the diffused fields and the resonance-like spectral artifacts due to multiple Mie scattering events that obscure the material absorption signatures. In this work, we demonstrate diffuse THz spectroscopy of a heterogeneous sample through turbid media using a novel technique based on the wavelet multiresolution analysis and the bimodality coefficient spectrum, which we define here for the first time using the skewness and kurtosis of the spectral images. The proposed method yields broadband and simultaneous material characterization at detection angles as high as 90° with respect to the incident beam. We determined the accuracy of the wavelet-based diffuse spectroscopy at oblique detection angles, by evaluating the area under the receiver operating characteristic curves, to be higher than 95%. This technique is agnostic to any a priori information on the spectral signatures of the sample materials or the characteristics of the scattering medium, and can be expanded for other broadband spectroscopic modalities.


Asunto(s)
Emulsiones , Lactosa/análisis , Dispersión de Radiación , Espectroscopía de Terahertz/métodos , Análisis de Ondículas
12.
IEEE Trans Terahertz Sci Technol ; 10(6): 656-666, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33738125

RESUMEN

We describe the application of the Discrete Wavelet Transform (DWT) in extracting the characteristic absorption signatures of materials from terahertz reflection spectra. We compare the performance of different mother wavelets, including Daubechies, Least Asymmetric (LA), and Coiflet, based on their phase and gain functions and filter lengths. We show that the phase functions of the wavelet and scaling filters result in spectral shifts to the absorption lines in the wavelet domain. We provide a solution by calculating advancement coefficients necessary to achieve effective zero-phase-function DWT. We demonstrate the utility of this signal processing technique using α-lactose monohydrate/polyethylene samples with different levels of rough surface scattering. In all cases, the DWT-based algorithm successfully extracts resonant signatures at 0.53 and 1.38 THz, even when they are obscured by the rough surface scattering effects. The DWT analysis with accompanying phase corrections can be utilized as a robust technique for material identification in non-destructive evaluation (NDE) using terahertz spectroscopy.

13.
IEEE Access ; 8: 228024-228031, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-35433151

RESUMEN

We report on the development and characterization of a handheld terahertz (THz) time-domain spectroscopic scanner for broadband imaging between approximately 0.25 and 1.25 THz. We designed and fabricated a 3D-printed fiber-coupled housing which provides an alignment-free strategy for the placement and operation of the THz optics. Image formation is achieved through telecentric beam steering over a planar surface through a custom f-θ scanning lens. This design achieves a consistent resolution over the full 12 × 19 mm field of view. Broadband spectral imaging is demonstrated using a 1951 United States Air Force Resolution Test Target. The consistency of the resolution over the wide field is validated through Boehler Star resolution measurements. Finally, a practical scenario of subsurface imaging on a damaged section of an aircraft wing is demonstrated. The THz PHASR is a field-deployable imaging system with the versatility to be applied to a much broader range of targets and imaging scenarios than previously possible, from industrial non-destructive testing to clinical diagnostic imaging.

14.
AIP Adv ; 10(12): 125313, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33344001

RESUMEN

Telecentric beam scanning using f-θ lenses offers nearly uniform spot size, linear beam displacement, and normal incidence angle over a planar surface. These unique properties allow for the minimization of imaging distortion over a wide field-of-view. In this article, we present a numerical method for designing custom f-θ lenses in the THz regime. We fabricated three lenses made from different commonly used polymer materials in the THz optics. We demonstrated their optical performance metrics compared to a conventional plano-convex lens over the broadband 0.3 THz-1 THz range. We find that the f-θ lens designed using the optical properties of high-density polyethylene achieved superior performance by maintaining a constant phase over a wide field of view of about 34°. We demonstrate this isophase property by measuring a constant time of arrival of the THz time-domain pulses over a reference mirror with a standard deviation of ∼19 fs, in excellent agreement with simulation predictions. This work will pave the way for the design and implementation of highly precise and fast telecentric imaging systems in the THz frequencies.

SELECCIÓN DE REFERENCIAS