1.
Transpl Int ; 37: 13030, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39155950

RESUMEN

Renal transplantation is common worldwide, with >25,000 procedures performed in 2022. Usage of prophylactic perinephric drains is variable in renal transplantation; drains are associated with risks, and there is a lack of consensus regarding benefit of routine drain placement in these patients. This meta-analysis assessed whether prophylactic drainage reduced need for reintervention postoperatively. This systematic review and meta-analysis was carried out using the Preferred Reporting Items in Systematic Reviews and Meta-Analysis, and prospectively registered on PROSPERO. Summary statistics for outcomes of interest underwent meta-analyses to a confidence interval (CI) of 95% and are presented as Forest Plots for Odds Ratio (OR). A systematic literature search in June 2023 revealed 1,540 unique articles across four databases. Of these, four retrospective cohort studies were selected. Meta-analysis of three studies showed no significant reduction in reintervention rate with pre-emptive drain placement, OR = 0.59 (95% CI: 0.16-2.23), p = 0.44. Meta-analysis did not show a significant reduction in perinephric collections with prophylactic drain insertion OR = 0.55 (95% CI: 0.13-2.37), p = 0.42. Finally, there is not good evidence that drain placement reduces superficial wound complications or improves 12-month graft survival. Further work is needed, including well-designed, prospective studies to assess the risks and benefits of drain placement in these patients. Systematic Review Registration: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42023422685, Identifier PROSPERO CRD42021255795.


Asunto(s)
Drenaje , Trasplante de Riñón , Humanos , Complicaciones Posoperatorias/prevención & control , Reoperación
2.
Transpl Int ; 34(4): 606-608, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33797146

RESUMEN

To keep the transplantation community informed about recently published level 1 evidence in organ transplantation ESOT and the Centre for Evidence in Transplantation have developed the Transplant Trial Watch. The Transplant Trial Watch is a monthly overview of 10 new randomised controlled trials (RCTs) and systematic reviews. This page of Transplant International offers commentaries on methodological issues and clinical implications on 2 articles article of particular interest from the CET Transplant Trial Watch monthly selection. For all high quality evidence in solid organ transplantation, visit the Transplant Library: www.transplantlibrary.com.


Asunto(s)
Trasplante de Órganos , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Revisiones Sistemáticas como Asunto
3.
Transpl Int ; 34(6): 996-998, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33949003

RESUMEN

To keep the transplantation community informed about recently published level 1 evidence in organ transplantation, ESOT (https://esot.org/) and the Centre for Evidence in Transplantation (https://www.transplantevidence.com/) have developed the Transplant Trial Watch. The Transplant Trial Watch is a monthly overview of 10 new randomized controlled trials (RCTs) and systematic reviews. This page of Transplant International offers commentaries on methodological issues and clinical implications on two articles of particular interest from the CET Transplant Trial Watch monthly selection. For all high-quality evidence in solid organ transplantation, visit the Transplant Library (www.transplantlibrary.com).


Asunto(s)
Trasplante de Órganos , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Transpl Int ; 34(8): 1335-1337, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34180561

RESUMEN

To keep the transplantation community informed about recently published level 1 evidence in organ transplantation ESOT (https://esot.org/) and the Centre for Evidence in Transplantation have developed the Transplant Trial Watch (www.transplantevidence.com). The Transplant Trial Watch is a monthly overview of 10 new randomized controlled trials (RCTs) and systematic reviews. This page of Transplant International offers commentaries on methodological issues and clinical implications on two articles of particular interest from the CET Transplant Trial Watch monthly selection. For all high quality evidence in solid organ transplantation, visit the Transplant Library: www.transplantlibrary.com.


Asunto(s)
Trasplante de Órganos , Humanos
5.
Transpl Int ; 34(10): 1751-1753, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34528333

RESUMEN

To keep the transplantation community informed about recently published level 1 evidence in organ transplantation ESOT (https://esot.org/) and the Centre for Evidence in Transplantation (www.transplantevidence.com) have developed the Transplant Trial Watch. The Transplant Trial Watch is a monthly overview of 10 new randomized controlled trials (RCTs) and systematic reviews. This page of Transplant International offers commentaries on methodological issues and clinical implications on two articles of particular interest from the CET Transplant Trial Watch monthly selection. For all high quality evidence in solid organ transplantation, visit the Transplant Library: www.transplantlibrary.com.


Asunto(s)
Trasplante de Órganos , Humanos
6.
Transpl Int ; 34(8): 1374-1385, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34062020

RESUMEN

There is limited evidence regarding the impact of allograft nephrectomy (AN) on the long-term outcome of subsequent kidney re-transplantation compared with no prior allograft nephrectomy. The aim of the present study was to conduct a systematic review and meta-analysis to estimate the accumulation of evidence over time. Primary outcomes were 5-year graft and patient survival. Cochrane library, Google scholar, PubMed, Medline and Embase were systematically searched. Meta-analysis was conducted using both fixed- and random-effects models. Study quality was assessed in duplicate using the Newcastle-Ottawa scale. Sixteen studies were included, with a total of 2256 patients. All included studies were retrospective and comparative. There was no significant difference in 5-year graft survival (GS) [Hazard Ratio (HR) = 1.11, 95% Confidence Intervals (CI): 0.89, 1.38, P = 0.37, I2  = 10%) or in 5-year patient survival (PS; HR = 0.70, 95% CI: 0.45, 1.10, P = 0.12, I2  = 0%]. Patients in the AN cohort were significantly younger than patients in the nonallograft nephrectomy (NAN) cohort by one year. Prior allograft nephrectomy was associated with a significantly higher risk of delayed graft function (DGF), acute rejection, primary nonfunction (PNF), per cent of panel reactive antibodies (% PRA) and allograft loss of the subsequent transplant. Although, DGF, % PRA, acute rejection and primary nonfunction rates were significantly higher in the AN cohort, allograft nephrectomy prior to re-transplantation had no significant association with five-year graft and patient survival.


Asunto(s)
Trasplante de Riñón , Aloinjertos , Rechazo de Injerto , Supervivencia de Injerto , Humanos , Nefrectomía , Estudios Retrospectivos
8.
Transpl Int ; 37: 12711, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38389709
10.
14.
Curr Opin Organ Transplant ; 24(4): 411-415, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31145158

RESUMEN

PURPOSE OF REVIEW: A key aspect of posttransplant management is to identify and treat graft injury before it becomes irreversible. The gold-standard for detection is histology, but biopsy is uncomfortable for the patient and carries a risk of complications. Detection of changes at a molecular level may preempt histological injury, and thereby identify injury earlier. RECENT FINDINGS: Indicators of immune system activation, such as candidate chemokines CXCL9 and CXCL10, and by-products of neutrophil activity, have been related to acute rejection and early allograft function. Transcriptomic studies of multiple-gene panels have identified candidate combinations that have proven very promising in risk-stratification and prediction of acute rejection, as well as diagnosis of both T-cell-mediated and antibody-mediated rejection. Serum and urine cell-free DNA is also a promising area of investigation, particularly in antibody-mediated rejection. SUMMARY: Noninvasive, rapid, and accurate tests for risk-prediction and diagnosis in renal transplant allografts are urgently required. The ideal candidate is one that can be measured in either urine or blood, is cheap, and is both sensitive and specific for the condition of interest. Numerous strategies have been proposed, with varying degrees of clinical and preclinical success. A few that meet the essential criteria have been evaluated; a few have made it as far as clinical testing.


Asunto(s)
Aloinjertos/fisiopatología , Biomarcadores/sangre , Rechazo de Injerto/sangre , Trasplante de Riñón/métodos , Humanos
16.
Transpl Int ; 36: 11045, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36713116
17.
Transpl Int ; 36: 11202, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37025500
19.
Transpl Int ; 36: 12256, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38020748
20.
Biomed Microdevices ; 20(1): 2, 2017 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-29159519

RESUMEN

Integration of microelectronics with microfluidics enables sophisticated lab-on-a-chip devices for sensing and actuation. In this paper, we investigate a novel method for in-situ microfluidics fabrication and packaging on wafer level. Two novel photo-patternable adhesive polymers were tested and compared, PA-S500H and DXL-009. The microfluidics fabrication method employs photo lithographical patterning of spin coated polymer films of PA or DXL and direct bonding of formed microfluidics to a top glass cover using die-to-wafer level bonding. These new adhesive materials remove the need for additional gluing layers. With this approach, we fabricated disposable microfluidic flow cytometers and evaluated the performance of those materials in the context of this application. DXL-009 exhibits lower autofluorescence compared to PA-S500H which improves detection sensitivity of fluorescently stained cells. Results obtained from the cytotoxicity test reveals that both materials are biocompatible. The functionality of these materials was demonstrated by detection of immunostained monocytes in microfluidic flow cytometers. The flexible, fully CMOS compatible fabrication process of these photo-patternable adhesive materials will simplify prototyping and mass manufacturing of sophisticated microfluidic devices with integrated microelectronics.


Asunto(s)
Adhesivos/química , Citometría de Flujo/instrumentación , Dispositivos Laboratorio en un Chip , Animales , Fibroblastos , Citometría de Flujo/métodos , Humanos , Ensayo de Materiales , Ratones , Polímeros/química , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS