Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 101(1): 79-86, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36453459

RESUMO

OBJECTIVES: This clinical study evaluated the efficacy of a novel radiation shielding system for the cardiac catheterization laboratory designed to provide comprehensive protection that obviates the need for personal lead aprons. BACKGROUND: Invasive Cardiologists are exposed to occupational health hazards related directly to radiation exposure (RE) and indirectly to the orthopedic burden of wearing only partially protective lead aprons. Innovations to reduce these risks are warranted. A novel comprehensive shielding system (ProtegoTM , Image Diagnostics Inc, Fitchburg, Ma) has been validated in pre-clinical studies to provide excellent radiation protection, sufficient for the State of Michigan to certify it for use without need for personal lead aprons. METHODS: This clinical analysis measured RE to a single Physician operator utilizing the ProtegoTM shield (and not wearing personal lead apron) during routine cardiac catheterization procedures (diagnostic and interventional). RE was measured at both thyroid and waist level with a real-time dosimetry system (RaysafeTM , Billdal, Sweden), calculated on a median per case basis (mrems). Additional parameters collected included procedure type, access site, per case fluoroscopy time, and patient factors including body mass index. RESULTS: In n=98 cases (25% diagnostic, 75% interventional including 22% chronic total occlusions), median/case RE was 0.4 mrems (thyroid) and 0.2 mrems (waist). RE=0 in 12 cases. In no case did radiation exposure exceed 3.2 mrems. CONCLUSION: The ProtegoTM shield system provides excellent RE protection to the Physician operator, without the need for personal lead aprons and has the potential to reduce catheterization laboratory occupational health hazards.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Resultado do Tratamento , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Roupa de Proteção , Cateterismo Cardíaco/efeitos adversos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Radiografia Intervencionista/efeitos adversos
2.
Curr Cardiol Rep ; 24(10): 1417-1424, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35980565

RESUMO

PURPOSE OF REVIEW: Repeat surgery for failed mitral valve prostheses and repairs are fraught with high rates of morbidity and mortality. Therefore, clinicians have evolved transcatheter technology as an alternative therapy. This review serves as an update as the field has moved out of the early learning curve of treating postsurgical mitral valve failures. RECENT FINDINGS: Mitral valve-in-valve procedures have higher rates of technical success and better in-hospital and 1-year mortality rates than mitral valve-in-ring cases. The higher rates of complications, including left ventricular outflow tract obstruction, paravalvular leak, valve embolization, and need for a 2nd valve, may explain these outcomes. Mitral valve-in-ring procedures have attenuated outcomes as compared to valve-in-valve. Clinicians should be cognizant of the nuanced complexities and the potential for suboptimal outcomes in using balloon-expandable valves for mitral valve-in-ring procedures.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Falha de Prótese , Instrumentos Cirúrgicos , Resultado do Tratamento
3.
Am J Physiol Lung Cell Mol Physiol ; 320(3): L301-L330, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33237815

RESUMO

On March 11, 2020, the World Health Organization declared coronavirus disease 2019 (COVID-19) a pandemic, and the reality of the situation has finally caught up to the widespread reach of the disease. The presentation of the disease is highly variable, ranging from asymptomatic carriers to critical COVID-19. The availability of angiotensin-converting enzyme 2 (ACE2) receptors may reportedly increase the susceptibility and/or disease progression of COVID-19. Comorbidities and risk factors have also been noted to increase COVID-19 susceptibility. In this paper, we hereby review the evidence pertaining to ACE2's relationship to common comorbidities, risk factors, and therapies associated with the susceptibility and severity of COVID-19. We also highlight gaps of knowledge that require further investigation. The primary comorbidities of respiratory disease, cardiovascular disease, renal disease, diabetes, obesity, and hypertension had strong evidence. The secondary risk factors of age, sex, and race/genetics had limited-to-moderate evidence. The tertiary factors of ACE inhibitors and angiotensin II receptor blockers had limited-to-moderate evidence. Ibuprofen and thiazolidinediones had limited evidence.


Assuntos
Enzima de Conversão de Angiotensina 2/metabolismo , Tratamento Farmacológico da COVID-19 , SARS-CoV-2/isolamento & purificação , COVID-19/metabolismo , COVID-19/virologia , Comorbidade , Humanos
4.
Catheter Cardiovasc Interv ; 98(6): 1185-1192, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33984182

RESUMO

OBJECTIVE/BACKGROUND: Small balloon expandable valves have higher echocardiographic transvalvular gradients and rates of prosthesis-patient mismatch (PPM) compared to larger valves. However, the impact of these echocardiographic findings on clinical outcomes is unknown. We sought to determine the clinical outcomes of 20 mm SAPIEN 3 (S3 BEV) compared to larger S3 BEV in relation to echocardiographic hemodynamics. METHODS: Using the STS/ACC transcatheter valve registry, we performed a propensity-matched comparison of patients undergoing treatment of native aortic valve stenosis using transfemoral, balloon-expandable implantation of 20 mm and ≥ 23 mm S3 BEVs. Baseline and procedure characteristics, echocardiographic variables and survival were analyzed. Multivariable logistic regression was used to identify predictors of 1-year mortality. RESULTS: After propensity matching of the 20 mm and ≥ 23 mm SAPIEN 3 valves, 3,931 pairs with comparable baseline characteristics were identified. Small valves were associated with significantly higher echocardiographic gradients at discharge (15.7 ± 7.1 mmHg vs. 11.7 ± 5.5 mmHg, p < 0.0001) and severe PPM rates (21.5% vs. 9.7%, p < 0.0001). There was no significant difference in 1-year all-cause mortality (20 mm: 13.0% vs. ≥23 mm: 12.7%, p = 0.72) or other major adverse event rates and outcomes between the two cohorts. Based on a multivariable analysis, elevated discharge mean gradient (>20 mmHg), severe PPM and the use of 20 mm versus ≥23 mm were not independent predictors of 1-year mortality. CONCLUSION: SAPIEN 3 20 mm valves were associated with higher echocardiographic gradients, and severe PPM rates compared to larger valves but these factors were not associated with significant differences in 1-year all-cause mortality or rehospitalization.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Eur J Haematol ; 106(2): 165-174, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33043484

RESUMO

BACKGROUND: Hypercoagulability may contribute to COVID-19 pathogenicity. The role of anticoagulation (AC) at therapeutic (tAC) or prophylactic doses (pAC) is unclear. OBJECTIVES: We evaluated the impact on survival of different AC doses in COVID-19 patients. METHODS: Retrospective, multi-center cohort study of consecutive COVID-19 patients hospitalized between March 13 and May 5, 2020. RESULTS: A total of 3480 patients were included (mean age, 64.5 years [17.0]; 51.5% female; 52.1% black and 40.6% white). 18.5% (n = 642) required intensive care unit (ICU) stay. 60.9% received pAC (n = 2121), 28.7% received ≥3 days of tAC (n = 998), and 10.4% (n = 361) received no AC. Propensity score (PS) weighted Kaplan-Meier plot demonstrated different 25-day survival probability in the tAC and pAC groups (57.5% vs 50.7%). In a PS-weighted multivariate proportional hazards model, AC was associated with reduced risk of death at prophylactic (hazard ratio [HR] 0.35 [95% confidence interval {CI} 0.22-0.54]) and therapeutic doses (HR 0.14 [95% CI 0.05-0.23]) compared to no AC. Major bleeding occurred more frequently in tAC patients (81 [8.1%]) compared to no AC (20 [5.5%]) or pAC (46 [2.2%]) subjects. CONCLUSIONS: Higher doses of AC were associated with lower mortality in hospitalized COVID-19 patients. Prospective evaluation of efficacy and risk of AC in COVID-19 is warranted.


Assuntos
Anticoagulantes , Tratamento Farmacológico da COVID-19 , COVID-19 , Hemorragia , Mortalidade Hospitalar , Unidades de Terapia Intensiva , SARS-CoV-2/metabolismo , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , COVID-19/sangue , COVID-19/complicações , COVID-19/mortalidade , Intervalo Livre de Doença , Feminino , Hemorragia/sangue , Hemorragia/tratamento farmacológico , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos , Taxa de Sobrevida
6.
Echocardiography ; 37(5): 738-757, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32362021

RESUMO

Evaluating the hemodynamic performance of aortic valve prostheses has relied primarily on echocardiography. This involves calculating the trans-prosthetic valve mean gradient (MG) and aortic valve area (AVA), and assessing for valvular and paravalvular regurgitation in a fashion similar to the native aortic valve. In conjunction with other echocardiographic and nonechocardiographic parameters, MG and AVA are used to distinguish between prosthesis stenosis, prosthesis patient mismatch, pressure recovery, increased flow, and measurement errors. This review will discuss the principles and limitations of echocardiographic evaluation of aortic valve prosthesis following surgical, and transcatheter aortic valve replacement and in comparison to invasive hemodynamics through illustrative clinical cases.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Hemodinâmica , Humanos , Desenho de Prótese , Índice de Gravidade de Doença , Resultado do Tratamento
7.
Echocardiography ; 37(10): 1551-1556, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32949015

RESUMO

INTRODUCTION: Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-infected patients commonly have elevated troponin and D-dimer levels, but limited imaging exists to support most likely etiologies in efforts to avoid staff exposure. The purpose of this study was to report transthoracic echocardiographic (TTE) findings in SARS-CoV-2 patients with correlating troponin and D-dimer levels. METHODS: We identified 66 SARS-CoV-2 patients (mean age 60 ± 15.7 years) admitted within a large, eight-hospital healthcare system over a 6-week period with a TTE performed. TTE readers were blinded to laboratory data with intra-observer and inter-observer analysis assessed. RESULTS: Sixty-six of 1780 SARS-CoV-2 patients were included and represented a high-risk population as 38 (57.6%) were ICU-admitted, 47 (71.2%) had elevated D-dimer, 41 (62.1%) had elevated troponin, and 25 (37.9%) died. Right ventricular (RV) dilation was present in 49 (74.2%) patients. The incidence and average D-dimer elevation was similar between moderate/severe vs. mild/no RV dilation (69.6% vs 67.6%, P = 1.0; 3736 ± 2986 vs 4141 ± 3351 ng/mL, P = .679). Increased left ventricular (LV) wall thickness was present in 46 (69.7%) with similar incidence of elevated troponin and average troponin levels compared to normal wall thickness (66.7% vs 52.4%, P = .231; 0.88 ± 1.9 vs 1.36 ± 2.4 ng/mL, P = .772). LV dilation was rare (n = 6, 9.1%), as was newly reduced LV ejection fraction (n = 2, 3.0%). CONCLUSION: TTE in SARS-CoV-2 patients is scarce, technically difficult, and reserved for high-risk patients. RV dilation is common in SARS-CoV-2 but does not correlate with elevated D-dimer levels. Increased LV wall thickness is common, while newly reduced LV ejection fraction is rare, and neither correlates with troponin levels.


Assuntos
Betacoronavirus , Infecções por Coronavirus/epidemiologia , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Pneumonia Viral/epidemiologia , Disfunção Ventricular/diagnóstico , COVID-19 , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2 , Disfunção Ventricular/epidemiologia
8.
Catheter Cardiovasc Interv ; 93(5): 1002-1023, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30790429

RESUMO

Aortic stenosis (AS) has become an increasingly prevalent clinical condition, as a result of the "greying of the population", the widespread application of sophisticated diagnostic tools including non-invasive imaging and invasive techniques, and the advent of minimally invasive surgical and percutaneous valve therapies. The diagnosis of severe AS traditionally has relied on the assessment of the mean transvalvular gradient (ΔPmean ) and aortic valve area (AVA) by either echocardiography or catheterization. However, other hemodynamic variables as flow, pressure recovery, and jet eccentricity also play a major role in determining the final hemodynamic state of AS. Moreover, mismatch between ΔPmean and AVA as in low flow low gradient AS and discordance between catheterization and echocardiographic studies in grading severity of AS have increased the complexity of AS diagnosis. The present case-based treatise emphasizes a multi-modality approach to delineation of the hemodynamic pathophysiology of different AS states. KEY POINTS: Reduction in the aortic valve area, flow across the aortic valve, and direction of the aortic stenosis jet determine the pressure gradient generated across the aortic valve in patients with aortic stenosis. Discordance between echo and catheterization maximum gradients is related to the inherent temporal differences between the times of their acquisition. Discordance between echo and catheterization mean gradients is related to pressure recovery and assumptions in the application of Bernoulli equation to estimate the aortic valve gradient. Pressure recovery relates to the ratio of the aortic valve area and ascending aortic diameter as well as the jet direction. Mismatch between area and gradient criteria for aortic stenosis severity may occur with or without concordance between echocardiographic and catheterization data. Errors of measurement should be excluded prior to assuming any mismatch or discordance between the data. Area gradient mismatch occurs when the aortic valve area is in the severe range, while the gradient is in the non-severe range as in low flow low gradient aortic stenosis. Reverse area gradient mismatch occurs when the gradient is in the severe range, while the aortic valve area is in the non-severe range as in congenital aortic stenosis with an eccentric jet.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Ecocardiografia Doppler , Hemodinâmica , Algoritmos , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Técnicas de Apoio para a Decisão , Humanos , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
9.
Catheter Cardiovasc Interv ; 93(4): E211-E216, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30280480

RESUMO

OBJECTIVES: The objective of this study was to determine the long-term major adverse cardiac events (MACE) in patients treated with intracoronary brachytherapy (ICBT) for coronary in-stent restenosis (ISR). BACKGROUND: ICBT was commonly used to treat coronary ISR prior to the availability of drug-eluting stents (DES). The long-term outcomes of ICBT for ISR remain unknown. METHODS: Six hundred and eighty consecutive patients who underwent ICBT treated for ISR between September 1998 and April 2005 were included in the study. Clinical and angiographic data were collected and the long-term MACE were measured for all-cause death, myocardial infarction (MI), and target vessel revascularization (TVR) at 10-year follow-up. RESULTS: Patients were 63 ± 11 years old (66% male). The majority of patients were treated with a bare metal stent 670/680 (99%) prior to ICBT. Significant baseline clinical findings include high incidence of smokers 479/680 (70%), hyperlipidemia 638/680 (94%), and multivessel disease 526/680 (77%). The majority of target lesions were diffuse 407/680 (60%), and either in the left anterior descending 258/680 (38%) or right coronary artery 215/680 (32%). At 10-year follow-up, the rate of death was 25%, MI was 22.4%, and TVR was 48%. CONCLUSION: MACE at 10-year follow-up following ICBT for ISR indicates steady rate of death and MI and declining rate of TVR after 5 years.


Assuntos
Braquiterapia , Reestenose Coronária/radioterapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Braquiterapia/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 90(3): 461-470, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28303659

RESUMO

OBJECTIVES: We describe the characteristics of atherosclerotic plaque in patients with peripheral arterial disease (PAD) using near-infrared spectroscopy-intravascular ultrasound (NIRS-IVUS) BACKGROUND: Imaging and autopsy studies have described atherosclerotic plaque in different vascular beds, including varying degrees of lipid, fibrosis, and calcification. Recently, NIRS has been validated as an accurate method for detecting lipid-core plaque (LCP) in the coronary circulation. Invasive evaluation of plaque composition using NIRS-IVUS has not been reported in different peripheral arterial circulations. METHODS: We performed invasive angiography and NIRS-IVUS in consecutive PAD patients prior to percutaneous revascularization. Imaging evaluation included parameters from angiography, IVUS, and NIRS. NIRS-IVUS findings were compared among different vascular beds with regard to the presence and extent of calcification and LCP. RESULTS: One hundred and forty-nine lesions in 126 PAD patients were enrolled, including the internal carotid (n = 10), subclavian/axillary (n = 9), renal (n = 14), iliac (n = 35), femoropopliteal (n = 69), and infrapopliteal (n = 12) arteries. Plaque morphology was calcified in 132 lesions (89%) and fibrous in 17 lesions (11%). Calcification varied from 100% of renal artery stenoses to 55% of subclavian/axillary artery stenoses. LCP was present in 48 lesions (32%) and prevalence varied from 60% in carotid artery stenoses to 0% in renal artery stenoses (P < 0.005). LCP was only observed in fibrocalcific plaque, and was longitudinally and circumferentially surrounded by a more extensive degree of calcium. CONCLUSIONS: NIRS-IVUS in stable PAD patients demonstrates a high frequency of calcific plaque and statistically significant differences in the frequency of LCP in different arterial beds. LCP, when present in the peripheral circulation, is always associated with calcified plaque. The strong co-localization of calcified plaque and LCP in severe PAD lesions may provide plaque-stabilizing effects; further studies are needed. © 2017 Wiley Periodicals, Inc.


Assuntos
Doença Arterial Periférica/diagnóstico por imagem , Placa Aterosclerótica , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Ultrassonografia de Intervenção/métodos , Calcificação Vascular/diagnóstico por imagem , Idoso , Angiografia Digital , Feminino , Fibrose , Humanos , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/metabolismo , Doença Arterial Periférica/patologia , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Calcificação Vascular/metabolismo , Calcificação Vascular/patologia
11.
Echocardiography ; 34(10): 1417-1425, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28833458

RESUMO

BACKGROUND AND AIM: Dividing patients with heart failure (HF) based solely on ejection fraction (EF) may over simplify the hemodynamic states of these patients. We describe a novel echo-derived hemodynamic HF model based on flow (stroke volume index [SVI]) and left atrial pressure (E:E') correlates. METHODS: A retrospective analysis of patients admitted with HF with both reduced (HFrEF) and preserved EF (HFpEF). Patients were subdivided into four hemodynamic groups based on echocardiographic SVI (< or ≥35 mL/m2 ) and E/E' (≥ or <15). Group A: normal flow and normal filling pressure, Group B: normal flow but high filling pressure, Group C: low flow and low filling pressure, and Group D: low flow and high filling pressure. RESULTS: A total of 176 patients were enrolled, 123 patients had HFrEF and 53 patients had HFpEF. Baseline characteristics were not statistically significant in both groups. In HFrEF, most patients were in group D compared to a heterogeneous distribution in HFpEF (P<.0001). In HFrEF, there was a trend toward an increase in B-type natriuretic peptide levels with a decrease in SVI and increase in E/E' (P=.05) but not in HFpEF. There was no difference in death, major adverse cardiac events, but a higher readmissions rate in the HFpEF group at 30 days and 18 months. CONCLUSIONS: Hemodynamic subgroups differ between HFrEF and HFpEF. There is no difference in major adverse cardiovascular events between both groups with increased readmissions in HPpEF patients. Larger studies may help assess the impact of echo-derived hemodynamic state on clinical outcome.


Assuntos
Pressão Atrial/fisiologia , Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Volume Sistólico/fisiologia , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos
13.
Vasc Med ; 21(4): 337-44, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26957574

RESUMO

The purpose of this study is to characterize the plaque morphology of severe stenoses in the superficial femoral artery (SFA) employing combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS). Atherosclerosis is the most common cause of symptomatic peripheral arterial disease. Plaque composition of SFA stenoses has been characterized as primarily fibrous or fibrocalcific by non-invasive and autopsy studies. NIRS has been validated to detect lipid-core plaque (LCP) in the coronary circulation. We imaged severe SFA stenoses with NIRS-IVUS prior to revascularization in 31 patients (46 stenoses) with Rutherford claudication ⩾ class 3. Angiographic parameters included lesion location and stenosis severity. IVUS parameters included plaque burden and presence of calcium. NIRS images were analyzed for LCP and maximum lipid-core burden index in a 4-mm length of artery (maxLCBI4mm). By angiography, 38 (82.6%) lesions were calcified and 9 (19.6%) were chronic total occlusions. Baseline stenosis severity and lesion length were 86.0 ± 11.0% and 36.5 ± 46.5 mm, respectively. NIRS-IVUS identified calcium in 45 (97.8%) lesions and LCP in 17 (37.0%) lesions. MaxLCBI4mm was 433 ± 244. All lesions with LCP also contained calcium; there were no non-calcified lesions with LCP. In conclusion, this is the first study of combined NIRS-IVUS in patients with PAD. NIRS-IVUS demonstrates that nearly all patients with symptomatic severe SFA disease have fibrocalcific plaque, and one-third of such lesions contain LCP. These findings contrast with those in patients with acute coronary syndromes, and may have implications regarding the pathophysiology of atherosclerosis in different vascular beds.


Assuntos
Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Placa Aterosclerótica , Espectroscopia de Luz Próxima ao Infravermelho , Ultrassonografia de Intervenção , Idoso , Angiografia Digital , Constrição Patológica , Feminino , Artéria Femoral/química , Artéria Femoral/patologia , Fibrose , Humanos , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/metabolismo , Doença Arterial Periférica/patologia , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/patologia
14.
Echocardiography ; 32(2): 372-82, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25138664

RESUMO

In patients with aortic stenosis (AS) and eccentric transaortic flow, greater pressure loss occurs as the jet collides with the aortic wall together with delayed and diminished pressure recovery. This leads to the elevated transaortic valve pressure gradients noted on both Doppler and cardiac catheterization. Such situations may present a diagnostic dilemma where traditional measures of stenosis severity indicate severe AS, while imaging modalities of the aortic valve geometric aortic valve area (GOA) suggest less than severe stenosis. In this study, we present a series of cases exemplifying this clinical dilemma and demonstrate how color M-mode, 2D and 3D transthoracic (TTE) and transesophageal (TEE) echocardiography, cardiac computed tomography angiography (CTA), and magnetic resonance imaging (MRI), may be used to resolve such discrepancies.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Pressão Sanguínea/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Ecocardiografia Doppler , Feminino , Humanos , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Adulto Jovem
15.
Am J Cardiol ; 213: 140-145, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38134979

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a successful treatment option for severe aortic stenosis. However, the long-term outcomes of TAVR in nonagenarians is lacking. We aimed to examine the long-term mortality and quality of life in nonagenarians after TAVR. This is a multicenter, retrospective analysis on patients with severe aortic stenosis who underwent TAVR. Patients were divided into 2 groups: nonagenarians (age ≥90 years) and age <90 years. The Kansas City cardiomyopathy questionnaire (KCCQ) and New York Heart Association (NYHA) scores were compared before and after TAVR. All-cause mortality was compared between both groups at 30 days, 1 year, and 5 years after TAVR using the Cox proportional hazard model. A total of 6,896 patients were included, of whom 591 were nonagenarians. Nonagenarians had a higher Society of Thoracic Surgeons perioperative risk of mortality (8.1 ± 4.6% vs 5.4 ± 4.2%, p <0.001) before TAVR. Both groups were similar in KCCQ and NYHA scores at baseline. At 1 year after TAVR, there was no significant difference in improvement in the KCCQ overall score between those aged <90 years and nonagenarians (-4.76, 95% confidence interval [CI] -11.4 to 1.9, p = 0.161). Similarly, there was no statistically significant difference in improvement in NYHA class between the 2 groups at 1 year (odds ratio 1.07, 95% CI 0.85 to 1.25), p = 0.526). The unadjusted 30-day (3.2% vs 2.7%, hazard ratio 1.11, 95% CI 0.70 to 1.80, p = 0.667) and 5-year (28.0% vs 26.6%, hazard ratio 1.05, 95% CI 0.89 to 1.24, p = 0.60) all-cause mortality were similar between the 2 groups. In conclusion, this study demonstrates an excellent long-term mortality rate at 5 years after TAVR in nonagenarians, comparable to patients younger than 90 years. There is a significant and enduring improvement in functional status in nonagenarians, observed up to 1 year after TAVR.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Humanos , Qualidade de Vida , Nonagenários , Resultado do Tratamento , Estudos Retrospectivos , Valva Aórtica/cirurgia , Fatores de Risco
16.
Am J Cardiol ; 220: 49-55, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38580038

RESUMO

On July 31, 2023, the Trifecta valve was withdrawn from the market after concerns regarding early (≤5 years) structural valve deterioration (SVD), mainly as aortic regurgitation (AR). Our aim was to determine the timing, mechanism, and impact of bioprosthetic SVD in patients who underwent redo aortic valve replacement (redo-AVR) with either redo-SAVR or valve-in-valve transcatheter aortic valve replacement (TAVR) using Trifecta versus other bioprosthetic valves. Patients who underwent redo-AVR for SVD at our institution were categorized into 2 groups based on the valve type: Trifecta versus non-Trifecta. Multivariate Cox proportional hazard model and Kaplan-Meier curves were used to compare mortality. A total of 171 patients were included; 58 (34%) had previous SAVR with a Trifecta valve and 113 (66%) with non-Trifecta valve. A total of 103 patients (60%) underwent valve-in-valve TAVR and 68 redo-SAVR (40%). The age, gender, and Society of Thoracic Surgeons score were similar between Trifecta and non-Trifecta groups. In patients with bioprosthetic valves requiring redo-AVR, Trifecta valves had an earlier onset of greater than moderate AR (4.5 vs 11.9 years, p <0.001) and earlier time to redo-AVR (5.5 vs 12 years, p <0.001). AR was more common as the mechanism of SVD in Trifecta versus non-Trifecta valves (55.2% vs 30.1%, p = 0.006). All-cause adjusted mortality from index SAVR was higher in the Trifecta than in non-Trifecta group (hazard ratio 4.1, 95% confidence interval 1.5 to 11.5, p = 0.007). In conclusion, compared with non-Trifecta valves, Trifecta valves exhibit early SVD primarily as AR and progress rapidly to significant SVD requiring redo-AVR. Mortality is significantly higher with Trifecta than in non-Trifecta valves, potentially impacting the results of SAVR versus TAVR studies.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Reoperação , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/mortalidade , Masculino , Feminino , Reoperação/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Fatores de Tempo , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos
17.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938841

RESUMO

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

18.
Int J Cardiol ; 411: 132243, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851542

RESUMO

INTRODUCTION: Patients with a small aortic annulus (SAA) undergoing aortic valve replacement are at increased risk of patient-prosthesis mismatch (PPM), which adversely affects outcomes. Transcatheter aortic valve replacement (TAVR) has shown promise in mitigating PPM compared to surgical aortic valve replacement (SAVR). METHODS: We conducted a systematic review and meta-analysis following PRISMA guidelines to compare clinical outcomes, mortality, and PPM between SAA patients undergoing TAVR and SAVR. Eligible studies were identified through comprehensive literature searches and assessed for quality and relevance. RESULTS: Nine studies with a total of 2476 patients were included. There was no significant difference in 30-day Mortality between TAVR vs SAVR groups (OR = 0.65, 95% CI [ 0.09-4.61], P = 0.22). There was no difference between both groups regarding myocardial infarction at 30 days (OR = 0.63, 95% CI [0.1-3.89], P = 0.62). TAVR was associated with a significantly lower 30-day major bleeding and 2-year major bleeding, Pooled studies were homogeneous (OR = 0.44, 95% CI [0.31-0.64], P < 0.01, I2 = 0, P = 0.89), (OR = 0.4 ,95% CI [0.21-0.77], P = 0.03, I2 = 0%, P = 0.62) respectively. TAVR was associated with a lower rate of moderate PPM (OR = 0.6, 95% CI [ 0.44-0.84], p value = 0.01, i2 = 0%, p value = 0.44). The overall effect estimate did not favor any of the two groups regarding short-term Mild AR (OR = 5.44, 95% CI [1.02-28.91], P = 0.05) and Moderate/severe AR (OR = 4.08, 95% CI [ 0.79-21.02], P = 0.08, I2 = 0%, P = 0.59). CONCLUSION: Our findings suggest that both TAVR and SAVR are viable options for treating AS in patients with a small aortic annulus. TAVR offers advantages in reducing PPM and major bleeding, while SAVR performs better in terms of pacemaker implantation. Future studies should focus on comparing newer generation TAVR techniques and devices with SAVR. Consideration of patient characteristics is crucial in selecting the optimal treatment approach for AS.

19.
JACC Cardiovasc Interv ; 17(8): 1032-1044, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38456883

RESUMO

BACKGROUND: The fifth-generation SAPIEN 3 Ultra Resilia valve (S3UR) incorporates several design changes as compared with its predecessors, the SAPIEN 3 (S3) and SAPIEN 3 Ultra (S3U) valves, including bovine leaflets treated with a novel process intended to reduce structural valve deterioration via calcification, as well as a taller external skirt on the 29-mm valve size to reduce paravalvular leak (PVL). The clinical performance of S3UR compared with S3 and S3U in a large patient population has not been previously reported. OBJECTIVES: The aim of this study was to compare S3UR to S3/S3U for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Patients enrolled in the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between January 1, 2021, and June 30, 2023, who underwent TAVR with S3UR or S3U/S3 valve platforms were propensity-matched and evaluated for procedural, in-hospital, and 30-day clinical and echocardiographic outcomes. RESULTS: 10,314 S3UR patients were propensity matched with 10,314 patients among 150,539 S3U/S3 patients. At 30 days, there were no statistically significant differences in death, stroke, or bleeding, but a numerically higher hospital readmission rate in the S3UR cohort (8.5% vs 7.7%; P = 0.04). At discharge, S3UR patients exhibited significantly lower mean gradients (9.2 ± 4.6 mm Hg vs 12.0 ± 5.7 mm Hg; P < 0.0001) and larger aortic valve area (2.1 ± 0.7 cm2 vs 1.9 ± 0.6 cm2; P < 0.0001) than patients treated with S3/S3U. The 29-mm valve size exhibited significant reduction in mild PVL (5.3% vs 9.4%; P < 0.0001). CONCLUSIONS: S3UR TAVR is associated with lower mean gradients and lower rates of PVL than earlier generations of balloon expandable transcatheter heart valve platforms.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Próteses Valvulares Cardíacas , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Hemodinâmica , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
20.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38316377

RESUMO

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Humanos , Feminino , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Desenho de Prótese , Idoso de 80 Anos ou mais , Resultado do Tratamento , Ajuste de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA