Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Am Coll Cardiol ; 33(6): 1485-90, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10334412

RESUMO

OBJECTIVES: We sought to determine the comparative accuracy of supine bicycle exercise echocardiography (SBE) and posttreadmill exercise echocardiography (TME) in detecting myocardial ischemia in patients with known or suspected coronary artery disease (CAD). BACKGROUND: Supine bicycle echocardiography and TME have been used for evaluation of CAD. However, the comparative accuracy of these modalities in the detection of ischemia in the same patients is not known. METHODS: Seventy-four patients (age 59 +/- 9 years [mean +/- SD]) referred for evaluation of coronary disease underwent SBE (starting at 25 to 50 W with 25-W increment every 3 min) and post-TME (Bruce protocol) in a random sequence. Digitized images at baseline and maximal exercise were interpreted in a random and blinded fashion. RESULTS: Maximal heart rate was higher during TME, whereas systolic blood pressure was higher during SBE, resulting in a similar double product. At quantitative angiography (n = 67), 57 patients had coronary stenosis (>50%). During SBE, ischemia was detected in 47 patients compared with 38 patients by TME (p < 0.001). Wall motion score index at maximal exercise was higher with SBE than with TME (1.48 +/- 0.51 vs. 1.38 +/- 0.43; p < 0.001). The extent of myocardial ischemia (number of ischemic segments) was higher during SBE compared with TME (3.3 +/- 3.4 vs. 2.3 +/- 2.9 segments; p = 0.004), whereas severity of abnormal wall motion was similar. The sensitivity of SBE and TME for CAD was 82% and 75% with a specificity of 80% and 90%, respectively. Image quality was similar with both techniques. Patients and sonographers favored SBE over TME. CONCLUSIONS: During SBE and TME exercise, patients achieve a similar double product. During SBE, however, the detection of ischemia is more frequent and more extensive which, along with patient and sonographer preference, makes supine bicycle exercise a valuable stress echocardiographic modality.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ecocardiografia , Teste de Esforço/métodos , Isquemia Miocárdica/diagnóstico por imagem , Adulto , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
2.
J Am Coll Cardiol ; 37(3): 741-7, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11693746

RESUMO

OBJECTIVES: We sought to determine the feasibility and accuracy of real-time imaging of myocardial contrast echocardiography (MCE) in detecting myocardial perfusion defects during exercise echocardiography compared with radionuclide tomography. BACKGROUND: Ultrasound imaging at a low mechanical index and frame rate (10 to 20 Hz) after intravenous injections of perfluorocarbon containing microbubbles has the potential to evaluate myocardial perfusion and wall motion (WVM) simultaneously and in real time. METHODS: One hundred consecutive patients with intermediate-to-high probability of coronary artery disease underwent treadmill (n = 50) or supine bicycle (n = 50) exercise echocardiography. Segmental perfusion with MCE and WM w ere assessed in real time before and at peak exercise using low mechanical index (0.3) and frame rates of 10 to 20 Hz after 0.3 ml bolus injections of intravenous Optison (Mallinckrodt Inc., San Diego, California). All patients had a dual isotope (rest thallium-201, stress sestamibi) study performed during the same exercise session, and 44 patients had subsequent quantitative coronary angiography. RESULTS: In the 100 patients, agreement between MCE and single photon emission computed tomography (SPECT) was 76%, while it was 88% between MCE and WM assessment. Compared with quantitative angiography, sensitivity of MCE, SPECT and WM was comparable (75%), with a specificity ranging from 81% to 100%. The combination of MCE and WM had the best balance between sensitivity and specificity (86% and 88%,respectively) with the highest accuracy (86%). CONCLUSIONS: The real-time assessment of myocardial perfusion during exercise stress echocardiography can be achieved with imaging at low mechanical index and frame rates. The combination of WM and MCE correlates well with SPECT and is a promising important addition to conventional stress echocardiography.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ecocardiografia sob Estresse , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Albuminas/uso terapêutico , Meios de Contraste , Doença das Coronárias/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Estudos de Viabilidade , Feminino , Fluorocarbonos/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
Am J Cardiol ; 74(12): 1207-10, 1994 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-7977091

RESUMO

Side branch occlusion may occur in the course of percutaneous transluminal coronary angioplasty (PTCA), particularly if complicated by site dissection. Concern that the additional placement of a stent may further jeopardize side branches is logical. Consequently, this study analyzed pre-PTCA, post-PTCA, poststent, and 6-month follow-up angiograms of 100 consecutive patients in whom 103 Gianturco-Roubin stents were implanted for acute or threatened closure after PTCA. Side branches were defined as major (> 50% of the stented vessel diameter) and minor (< 50%). Minor branches, often < 1 mm in diameter, were assessed only for patency. One hundred eight major branches, of which 33 were diseased (> 50% stenosis), and 129 minor branches were analyzed. Seven major branches (6%), all of which were diseased before PTCA, and 23 minor branches (18%) were lost after PTCA. Immediately after stent insertion, only 1 additional major and 1 minor branch were lost, whereas 2 of 7 major (29%) and 9 of 23 minor (39%) branches reappeared. At follow-up angiography, 7 major branches (6%) were more stenosed and 6 (6%) were improved compared with the angiogram before PTCA. Only 2 major (2%) and 5 minor (4%) branches remained occluded. Additionally, 2 major and 1 minor branch, which were patent after PTCA and stenting, were occluded at follow-up as a result of total occlusion of the stented segment.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Angioplastia Coronária com Balão , Doença das Coronárias/terapia , Stents , Doença Aguda , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Constrição Patológica/terapia , Vasos Coronários/patologia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Coron Artery Dis ; 7(11): 851-61, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8993944

RESUMO

BACKGROUND: Thrombin-mediated vascular smooth muscle cell proliferation has been implicated in coronary restenosis. Attempts to inhibit this mitogenic activity have recently focused on non-physiologic direct thrombin inhibitors, whereas endogenous thrombin inhibitors such as antithrombin III (ATIII) have received little attention. ATIII is the main physiologic inhibitor of thrombin and may thus be a potential therapeutic agent for prevention of restenosis. METHODS: Human ATIII (125 U/kg) and heparin (200 U/kg) were administered to 12 atherosclerotic swine 30 min prior to inducing restenosis by oversized stent (left anterior descending and right coronary arteries; stent-to-artery ratio approximately 1.2) and balloon injury (circumflex; balloon artery ratio approximately 1.2). Eleven control swine received only heparin every 6 h for 24 h and were subjected to similar stent and balloon injury. Quantitative coronary angiography [change in minimal lumen diameter (delta MLD)] and morphometric analysis [percentage area stenosis (PAS)] were performed 4 weeks later. RESULTS: ATIII activity (mean +/- SD) of treated swine increased from a baseline of 103 +/- 10% to a peak of 266 +/- 48%, whereas trough levels were maintained at 259 +/- 55% for 72 h by drug infusions every 6 h. The delta MLD, the primary angiographic endpoint in the balloon injured vessel was -0.57 +/- 0.33 mm in heparin group versus -0.26 +/- 0.27 mm in the ATIII group (P < or = 0.03). For stented vessels the delta MLD was -0.61 +/- 0.33 mm in the heparin group versus -0.41 +/- 0.37 mm in the ATIII group (P < or = 0.06). The PAS for the balloon injured vessels was 30 +/- 12% in the heparin group versus 19 +/- 14 in the ATIII group (P < or = 0.06). In stented vessels the PAS was 45 +/- 16% in the heparin group versus 38 +/- 16% in the ATIII group (P < or = 0.1). CONCLUSION: Supraphysiologic ATIII levels in combination with heparin inhibits the reduction in MLD in coronary arteries subjected to oversized balloon injury and demonstrates a beneficial trend in arteries subjected to oversized stent injury. These data provide cautious optimism for further investigation with ATIII to prevent coronary restenosis.


Assuntos
Antitrombina III/administração & dosagem , Doença das Coronárias/tratamento farmacológico , Inibidores de Serina Proteinase/administração & dosagem , Túnica Íntima/patologia , Angioplastia com Balão/efeitos adversos , Animais , Antitrombina III/efeitos adversos , Arteriosclerose/sangue , Arteriosclerose/complicações , Arteriosclerose/patologia , Divisão Celular , Colesterol/sangue , Angiografia Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/etiologia , Vasos Coronários/lesões , Vasos Coronários/patologia , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Fibrinolíticos/administração & dosagem , Fibrinolíticos/efeitos adversos , Seguimentos , Heparina/administração & dosagem , Heparina/efeitos adversos , Infusões Intravenosas , Recidiva , Segurança , Inibidores de Serina Proteinase/efeitos adversos , Suínos , Porco Miniatura , Túnica Íntima/lesões
5.
Radiol Technol ; 61(6): 467-71, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2374807

RESUMO

Over the last few years, there has been a growing interest in digital processing of coronary angiograms to derive precise quantitative measurements on the severity of coronary stenoses. A reliable computer assisted, fully automated edge-detection technique has been developed to assess absolute coronary arterial dimensions from 35 mm cineangiograms. A region of interest to be analyzed is optically magnified and video-digitized prior to the automated contour detection. Contour positions are corrected for pin-cushion distortion.


Assuntos
Cineangiografia/métodos , Angiografia Coronária , Intensificação de Imagem Radiográfica , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes
7.
Am Heart J ; 119(1): 178-84, 1990 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2404387

RESUMO

Quantitative coronary angiographic measurements and visual estimates of coronary lesion severity were compared prospectively before, immediately following, and 6 months following percutaneous transluminal coronary angioplasty. Mean percent diameter stenosis before angioplasty was 87.9 +/- 9.9% by visual analysis and 64.6 +/- 9.2% by quantitative coronary angiography (p = 0.0001). Differences between these two techniques were also found immediately post-angioplasty (visual analysis 29.5 +/- 11.8%, quantitative coronary angiography 22.8 +/- 11.8%, p = 0.0002) and at 6 months (visual analysis 46.5 +/- 27.4%, quantitative coronary angiography 30.2 +/- 20.4%, p = 0.0001). These differences significantly affected the determination of restenosis by three definitions. (1) Lesion recurrence with greater than or equal to 50% stenosis at follow-up: 38 of 92 (41%) by visual analysis versus 20 of 92 (22%) by quantitative coronary angiography (p less than 0.01). (2) Increase of greater than or equal to 30% stenosis: 34 of 92 (37%) by visual analysis versus 20 of 92 (22%) by quantitative coronary angiography (p less than 0.01). (3) Loss of 50% of previous improvement: 31 of 92 (34%) by visual analysis versus 24 of 92 (26%) by quantitative coronary angiography (p = 0.08). In addition, determination of success or failure of percutaneous transluminal coronary angioplasty was affected by the interpretative technique, but these differences were not statistically significant. We conclude that visual estimates of lesion severity are consistently and significantly higher than quantitative measurements. Consequently, restenosis rates, using currently applied definitions, differ considerably depending on the method of analyzing lesion severity.


Assuntos
Angiografia/métodos , Angioplastia Coronária com Balão , Angiografia Coronária , Diagnóstico por Computador , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/terapia , Seguimentos , Humanos , Estudos Prospectivos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA