Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Climacteric ; 16(5): 561-7, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23157491

RESUMO

BACKGROUND AND AIMS: The metabolic syndrome (MetS) is a constellation of risk factors increasing the risk of developing cardiovascular disease and diabetes. Little information is available on the association between MetS and menopausal status in Iranian women. Therefore, the purpose of the current study was to examine the prevalence and severity of MetS in pre- and postmenopausal women based on two commonly employed assessment criteria. METHODS: A total of 490 premenopausal and 434 postmenopausal women from the Shiraz Women's Health Cohort Study were included in the study. MetS was defined according to the criteria of the National Cholesterol Education Program-Adult Panel Treatment III (NCEP-ATPIII) and the International Diabetes Federation (IDF). Clinical, biochemical and anthropometric measures were collected from all study participants for determination of MetS. RESULTS: The majority of participants had at least two components of MetS. Postmenopausal women, compared to premenopausal women, had a higher prevalence of MetS. The prevalences of MetS were 60.2% and 59.4% based on the NCEP-ATPIII and IDF definitions, respectively. Waist circumference, waist-to-hip ratio, blood pressure, and levels of fasting plasma glucose, total cholesterol, low density lipoprotein cholesterol, and triglycerides were higher in postmenopausal women compared to premenopausal women. CONCLUSIONS: MetS is a major threat to women's health and an aging population, and longitudinal studies to determine the mechanism of postmenopausal MetS are required.


Assuntos
Síndrome Metabólica/epidemiologia , Pós-Menopausa , Pré-Menopausa , Adulto , Glicemia/análise , Pressão Sanguínea , Índice de Massa Corporal , Jejum , Feminino , Humanos , Irã (Geográfico)/epidemiologia , Lipídeos/sangue , Pessoa de Meia-Idade , Obesidade , Fatores de Risco , Triglicerídeos/sangue , Circunferência da Cintura , Relação Cintura-Quadril
2.
Public Health ; 127(8): 704-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23871394

RESUMO

OBJECTIVES: To determine the epidemiological characteristics of fatal traffic accidents in Fars province, Iran. STUDY DESIGN: This cross-sectional study included 3642 traffic accident deaths in Fars province, Iran between November 2009 and November 2011. The data source was the Fars Forensic Medicine Registry, which covers the entire province. According to Iranian law, all deaths resulting from injuries or accidents must be investigated to determine the exact cause of death by autopsy. All such deaths are referred to forensic medicine centres in each city, and all data are sent to the main centre in Shiraz, the capital city of Fars province. RESULTS: Males accounted for 78.3% of the decedents (sex ratio of almost 3.6:1), and the mean ± standard deviation age of all decedents was 32.2 ± 20.3 years. Autopsy reports indicated that head trauma was the most common cause of death. Most collisions were vehicle-vehicle crashes (52.3%), with cars and motorcycles being the most prevalent modes of transport (39.6% and 24.6%, respectively). Fatal accidents were most common during the summer. Most fatal injuries (61.4%) occurred on outer-city roads and 27.4% occurred on inner-city roads. Significant associations were found between decedent's status (car driver, motorcycle driver or passenger, pedestrian or passenger) and interval between injury and death, light conditions at the scene of the accident, place of death, site of injury and cause of death. CONCLUSION: Although the clinical management of trauma patients has improved in Iran, coordination between trauma system organizations is required to decrease the burden of injuries.


Assuntos
Acidentes de Trânsito/mortalidade , Acidentes de Trânsito/estatística & dados numéricos , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos Transversais , Feminino , Medicina Legal , Humanos , Lactente , Irã (Geográfico)/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Distribuição por Sexo , Adulto Jovem
3.
J Mech Behav Biomed Mater ; 132: 105291, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35660552

RESUMO

The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti-6Al-4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p < 0.05) in the mean stiffness, mean ultimate load, or mean ultimate displacement were detected between the LA- and TO-implant groups. No implant failures were observed during quasi-static or cyclic testing under masticatory loads that were substantially higher (>1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome.


Assuntos
Reconstrução Mandibular , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Estresse Mecânico , Titânio , Fluxo de Trabalho
4.
ACS Biomater Sci Eng ; 6(10): 5486-5492, 2020 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-33320546

RESUMO

The complex reconstructive surgeries for which patient-specific orthopedic, maxillofacial, or dental implants are used often necessitate wounds that are open for a considerable amount of time. Unsurprisingly, this allows bacteria to establish implant-associated infection, despite the scrupulous sterilization efforts made during surgery. Here, we developed a prophylactic bactericidal coating via electrophoretic deposition technology for two 3D-printed porous titanium implant designs. The surface characteristics, antibiotic release behavior, antibacterial properties, and impact on osteoblast cell proliferation of the optimized coatings were investigated. The results unequivocally confirmed the biofunctionality of the implants in vitro. This study reveals a new avenue for future antibacterial patient-specific implants.


Assuntos
Anti-Infecciosos , Materiais Revestidos Biocompatíveis , Antibacterianos/farmacologia , Humanos , Próteses e Implantes , Titânio
5.
Acta Biomater ; 83: 153-166, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30389577

RESUMO

Recently, lattice titanium manufactured by additive manufacturing (AM) techniques has been utilized in various applications, including biomedical. The effects of topological design and processing parameters on the fatigue behaviour of such meta-biomaterials have been studied before. Most studies show that the fatigue life of additively manufactured lattice structures is limited. Post-processing techniques could play a major role in improving the fatigue of these promising biomaterials. This study aims to provide an in-depth investigation into the effects of heat treatments, hot isostatic pressing (HIP), sand blasting, and chemical etching on the microstructure, surface morphology, strength and fatigue resistance of selective laser melted titanium meta-biomaterials. It was found that the combination of microstructural design and surface engineering, induced by HIP and sand blasting respectively, allows to increase the endurance limit of these lattice meta-biomaterials by a factor of two. HIP treatment substantially decreased the internal porosity and transformed the microstructure to a more ductile mixture of α +â€¯ß phases. Sand blasting allowed to eliminate surface imperfections and induced favourable compressive stress in the surface layer of the struts. STATEMENT OF SIGNIFICANCE: Additively manufactured metallic meta-biomaterials are progressively being used as bone replacement orthopedic implants. While there is a great amount of research related to topological designs and their effect on mechanical (e.g. stiffness), physical (e.g. mass transport), and biological (e.g. osseointegration) properties, fatigue lifetime of such structures remains limited. This study provides fundamental investigation into the combined effect of microstructural design and surface engineering of titanium meta-biomaterial, enabled through various post treatment methods ranging from heat treatments to physical and chemical surface modifications. The findings show that fatigue life is significantly improved by applying developed herein novel method, which effortlessly can be used on other bone-mimicking metallic meta-biomaterials.


Assuntos
Materiais Biocompatíveis/química , Substitutos Ósseos/química , Teste de Materiais , Titânio/química , Força Compressiva , Estresse Mecânico , Resistência à Tração
6.
J Biomed Mater Res A ; 106(7): 1798-1811, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29468807

RESUMO

Magnesium and its alloys have the intrinsic capability of degrading over time in vivo without leaving toxic degradation products. They are therefore suitable for use as biodegradable scaffolds that are replaced by the regenerated tissues. One of the main concerns for such applications, particularly in load-bearing areas, is the sufficient mechanical integrity of the scaffold before sufficient volumes of de novo tissue is generated. In the majority of the previous studies on the effects of biodegradation on the mechanical properties of porous biomaterials, the change in the elastic modulus has been studied. In this study, variations in the static and fatigue mechanical behavior of porous structures made of two different Mg alloys (AZ63 and M2) over different dissolution times ( 6, 12, and 24 h) have been investigated. The results showed an increase in the mechanical properties obtained from stress-strain curve (elastic modulus, yield stress, plateau stress, and energy absorption) after 6-12 h and a sharp decrease after 24 h. The initial increase in the mechanical properties may be attributed to the accumulation of corrosion products in the pores of the porous structure before degradation has considerably proceeded. The effects of mineral deposition was more pronounced for the elastic modulus as compared to other mechanical properties. That may be due to insufficient integration of the deposited particles in the structure of the magnesium alloys. While the bonding of the parts being combined in a composite-like material is of great importance in determining its yield stress, the effects of bonding strength of both parts is much lower in determining the elastic modulus. The results of the current study also showed that the dissolution rates of the studied Mg alloys were too high for direct use in human body. © 2018 Authors Journal of Biomedical Materials Research Part A Published by Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 1798-1811, 2018.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Magnésio/química , Estresse Mecânico , Módulo de Elasticidade , Porosidade , Espectrometria por Raios X , Fatores de Tempo , Microtomografia por Raio-X
7.
J Mech Behav Biomed Mater ; 79: 254-263, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29335192

RESUMO

In this study, we tried to quantify the isolated and modulated effects of topological design and material type on the mechanical properties of AM porous biomaterials. Towards this aim, we assembled a large dataset comprising the mechanical properties of AM porous biomaterials with different topological designs (i.e. different unit cell types and relative densities) and material types. Porous structures were additively manufactured from Co-Cr using a selective laser melting (SLM) machine and tested under quasi-static compression. The normalized mechanical properties obtained from those structures were compared with mechanical properties available from our previous studies for porous structures made from Ti-6Al-4V and pure titanium as well as with analytical solutions. The normalized values of elastic modulus and yield stress were found to be relatively close to each other as well as in agreement with analytical solutions regardless of material type. However, the material type was found to systematically affect the mechanical properties of AM porous biomaterials in general and the post-elastic/post-yield range (plateau stress and energy absorption capacity) in particular. To put this in perspective, topological design could cause up to 10-fold difference in the mechanical properties of AM porous biomaterials while up to 2-fold difference was observed as a consequence of changing the material type.


Assuntos
Materiais Biocompatíveis , Teste de Materiais , Módulo de Elasticidade , Porosidade , Estresse Mecânico
8.
Acta Biomater ; 65: 292-304, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29127065

RESUMO

Additive manufacturing (AM) techniques enable fabrication of bone-mimicking meta-biomaterials with unprecedented combinations of topological, mechanical, and mass transport properties. The mechanical performance of AM meta-biomaterials is a direct function of their topological design. It is, however, not clear to what extent the material type is important in determining the fatigue behavior of such biomaterials. We therefore aimed to determine the isolated and modulated effects of topological design and material type on the fatigue response of metallic meta-biomaterials fabricated with selective laser melting. Towards that end, we designed and additively manufactured Co-Cr meta-biomaterials with three types of repeating unit cells and three to four porosities per type of repeating unit cell. The AM meta-biomaterials were then mechanically tested to obtain their normalized S-N curves. The obtained S-N curves of Co-Cr meta-biomaterials were compared to those of meta-biomaterials with same topological designs but made from other materials, i.e. Ti-6Al-4V, tantalum, and pure titanium, available from our previous studies. We found the material type to be far more important than the topological design in determining the normalized fatigue strength of our AM metallic meta-biomaterials. This is the opposite of what we have found for the quasi-static mechanical properties of the same meta-biomaterials. The effects of material type, manufacturing imperfections, and topological design were different in the high and low cycle fatigue regions. That is likely because the cyclic response of meta-biomaterials depends not only on the static and fatigue strengths of the bulk material but also on other factors that may include strut roughness, distribution of the micro-pores created inside the struts during the AM process, and plasticity. STATEMENT OF SIGNIFICANCE: Meta-biomaterials are a special class of metamaterials with unusual or unprecedented combinations of mechanical, physical (e.g. mass transport), and biological properties. Topologically complex and additively manufactured meta-biomaterials have been shown to improve bone regeneration and osseointegration. The mechanical properties of such biomaterials are directly related to their topological design and material type. However, previous studies of such biomaterials have largely neglected the effects of material type, instead focusing on topological design. We show here that neglecting the effects of material type is unjustified. We studied the isolated and combined effects of topological design and material type on the normalized S-N curves of metallic bone-mimicking biomaterials and found them to be more strongly dependent on the material type than topological design.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Teste de Materiais , Estresse Mecânico , Cromo/química , Cobalto/química , Manufaturas , Microscopia Eletrônica de Varredura , Porosidade
9.
Acta Biomater ; 53: 572-584, 2017 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-28213101

RESUMO

Porous biomaterials that simultaneously mimic the topological, mechanical, and mass transport properties of bone are in great demand but are rarely found in the literature. In this study, we rationally designed and additively manufactured (AM) porous metallic biomaterials based on four different types of triply periodic minimal surfaces (TPMS) that mimic the properties of bone to an unprecedented level of multi-physics detail. Sixteen different types of porous biomaterials were rationally designed and fabricated using selective laser melting (SLM) from a titanium alloy (Ti-6Al-4V). The topology, quasi-static mechanical properties, fatigue resistance, and permeability of the developed biomaterials were then characterized. In terms of topology, the biomaterials resembled the morphological properties of trabecular bone including mean surface curvatures close to zero. The biomaterials showed a favorable but rare combination of relatively low elastic properties in the range of those observed for trabecular bone and high yield strengths exceeding those reported for cortical bone. This combination allows for simultaneously avoiding stress shielding, while providing ample mechanical support for bone tissue regeneration and osseointegration. Furthermore, as opposed to other AM porous biomaterials developed to date for which the fatigue endurance limit has been found to be ≈20% of their yield (or plateau) stress, some of the biomaterials developed in the current study show extremely high fatigue resistance with endurance limits up to 60% of their yield stress. It was also found that the permeability values measured for the developed biomaterials were in the range of values reported for trabecular bone. In summary, the developed porous metallic biomaterials based on TPMS mimic the topological, mechanical, and physical properties of trabecular bone to a great degree. These properties make them potential candidates to be applied as parts of orthopedic implants and/or as bone-substituting biomaterials. STATEMENT OF SIGNIFICANCE: Bone-substituting biomaterials aim to mimic bone properties. Although mimicking some of bone properties is feasible, biomaterials that could simultaneously mimic all or most of the relevant bone properties are rare. We used rational design and additive manufacturing to develop porous metallic biomaterials that exhibit an interesting combination of topological, mechanical, and mass transport properties. The topology of the developed biomaterials resembles that of trabecular bone including a mean curvature close to zero. Moreover, the developed biomaterials show an unusual combination of low elastic modulus to avoid stress shielding and high strength to provide mechanical support. The fatigue resistance of the developed biomaterials is also exceptionally high, while their permeability is in the range of values reported for bone.


Assuntos
Materiais Biomiméticos/síntese química , Substitutos Ósseos/síntese química , Metais/química , Titânio/química , Ligas , Força Compressiva , Módulo de Elasticidade , Permeabilidade , Porosidade , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
10.
J Mech Behav Biomed Mater ; 50: 180-91, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26143351

RESUMO

Since the advent of additive manufacturing techniques, regular porous biomaterials have emerged as promising candidates for tissue engineering scaffolds owing to their controllable pore architecture and feasibility in producing scaffolds from a variety of biomaterials. The architecture of scaffolds could be designed to achieve similar mechanical properties as in the host bone tissue, thereby avoiding issues such as stress shielding in bone replacement procedure. In this paper, the deformation and failure mechanisms of porous titanium (Ti6Al4V) biomaterials manufactured by selective laser melting from two different types of repeating unit cells, namely cubic and diamond lattice structures, with four different porosities are studied. The mechanical behavior of the above-mentioned porous biomaterials was studied using finite element models. The computational results were compared with the experimental findings from a previous study of ours. The Johnson-Cook plasticity and damage model was implemented in the finite element models to simulate the failure of the additively manufactured scaffolds under compression. The computationally predicted stress-strain curves were compared with the experimental ones. The computational models incorporating the Johnson-Cook damage model could predict the plateau stress and maximum stress at the first peak with less than 18% error. Moreover, the computationally predicted deformation modes were in good agreement with the results of scaling law analysis. A layer-by-layer failure mechanism was found for the stretch-dominated structures, i.e. structures made from the cubic unit cell, while the failure of the bending-dominated structures, i.e. structures made from the diamond unit cells, was accompanied by the shearing bands of 45°.


Assuntos
Materiais Biocompatíveis/química , Fenômenos Mecânicos , Ligas , Força Compressiva , Lasers , Modelos Moleculares , Conformação Molecular , Porosidade , Estresse Mecânico , Titânio/química
11.
J Mech Behav Biomed Mater ; 43: 91-100, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25579495

RESUMO

Meta-materials are structures when their small-scale properties are considered, but behave as materials when their homogenized macroscopic properties are studied. There is an intimate relationship between the design of the small-scale structure and the homogenized properties of such materials. In this article, we studied that relationship for meta-biomaterials that are aimed for biomedical applications, otherwise known as meta-biomaterials. Selective laser melted porous titanium (Ti6Al4V ELI) structures were manufactured based on three different types of repeating unit cells, namely cube, diamond, and truncated cuboctahedron, and with different porosities. The morphological features, static mechanical properties, and fatigue behavior of the porous biomaterials were studied with a focus on their fatigue behavior. It was observed that, in addition to static mechanical properties, the fatigue properties of the porous biomaterials are highly dependent on the type of unit cell as well as on porosity. None of the porous structures based on the cube unit cell failed after 10(6) loading cycles even when the applied stress reached 80% of their yield strengths. For both other unit cells, higher porosities resulted in shorter fatigue lives for the same level of applied stress. When normalized with respect to their yield stresses, the S-N data points of structures with different porosities very well (R(2)>0.8) conformed to one single power law specific to the type of the unit cell. For the same level of normalized applied stress, the truncated cuboctahedron unit cell resulted in a longer fatigue life as compared to the diamond unit cell. In a similar comparison, the fatigue lives of the porous structures based on both truncated cuboctahedron and diamond unit cells were longer than that of the porous structures based on the rhombic dodecahedron unit cell (determined in a previous study). The data presented in this study could serve as a basis for design of porous biomaterials as well as for corroboration of relevant analytical and computational models.


Assuntos
Materiais Biocompatíveis/química , Lasers , Teste de Materiais , Transição de Fase , Estresse Mecânico , Ligas , Modelos Moleculares , Conformação Molecular , Porosidade , Relação Estrutura-Atividade , Titânio/química
12.
J Mech Behav Biomed Mater ; 34: 106-15, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24566381

RESUMO

Cellular structures with highly controlled micro-architectures are promising materials for orthopedic applications that require bone-substituting biomaterials or implants. The availability of additive manufacturing techniques has enabled manufacturing of biomaterials made of one or multiple types of unit cells. The diamond lattice unit cell is one of the relatively new types of unit cells that are used in manufacturing of regular porous biomaterials. As opposed to many other types of unit cells, there is currently no analytical solution that could be used for prediction of the mechanical properties of cellular structures made of the diamond lattice unit cells. In this paper, we present new analytical solutions and closed-form relationships for predicting the elastic modulus, Poisson׳s ratio, critical buckling load, and yield (plateau) stress of cellular structures made of the diamond lattice unit cell. The mechanical properties predicted using the analytical solutions are compared with those obtained using finite element models. A number of solid and porous titanium (Ti6Al4V) specimens were manufactured using selective laser melting. A series of experiments were then performed to determine the mechanical properties of the matrix material and cellular structures. The experimentally measured mechanical properties were compared with those obtained using analytical solutions and finite element (FE) models. It has been shown that, for small apparent density values, the mechanical properties obtained using analytical and numerical solutions are in agreement with each other and with experimental observations. The properties estimated using an analytical solution based on the Euler-Bernoulli theory markedly deviated from experimental results for large apparent density values. The mechanical properties estimated using FE models and another analytical solution based on the Timoshenko beam theory better matched the experimental observations.


Assuntos
Materiais Biocompatíveis/química , Análise de Elementos Finitos , Fenômenos Mecânicos , Titânio/química , Ligas , Modelos Moleculares , Conformação Molecular , Porosidade
13.
J Biomech ; 47(11): 2700-8, 2014 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-24882739

RESUMO

Segmental bone defect animal models are often used for evaluating the bone regeneration performance of bone substituting biomaterials. Since bone regeneration is dependent on mechanical loading, it is important to determine mechanical load transfer after stabilization of the defect and to study the effects of biomaterial stiffness on the transmitted load. In this study, we assess the mechanical load transmitted over a 6mm femur defect that is stabilized with an internal PEEK fixation plate. Subsequently, three types of selective laser melted porous titanium implants with different stiffness values were used to graft the defect (five specimens per group). In one additional group, the defect was left empty. Micro strain gauges were used to measure strain values at four different locations of the fixation plate during external loading on the femoral head. The load sharing between the fixation plate and titanium implant was highly variable with standard deviations of measured strain values between 31 and 93% of the mean values. As a consequence, no significant differences were measured between the forces transmitted through the titanium implants with different elastic moduli. Only some non-significant trends were observed in the mean strain values that, consistent with the results of a previous finite element study, implied the force transmitted through the implant increases with the implant stiffness. The applied internal fixation method does not standardize mechanical loading over the defect to enable detecting small differences in bone regeneration performances of bone substituting biomaterials. In conclusion, the fixation method requires further optimization to reduce the effects of the operative procedure and make the mechanical loading more consistent and improve the overall sensitivity of this rat femur defect model.


Assuntos
Materiais Biocompatíveis , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fixadores Internos , Animais , Regeneração Óssea , Substitutos Ósseos , Módulo de Elasticidade , Fêmur/cirurgia , Análise de Elementos Finitos , Lasers , Masculino , Próteses e Implantes , Ratos , Ratos Wistar , Titânio
14.
J Mech Behav Biomed Mater ; 36: 109-19, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24831611

RESUMO

Bio-functionalizing surface treatments are often applied for improving the bioactivity of biomaterials that are based on otherwise bioinert titanium alloys. When applied on highly porous titanium alloy structures intended for orthopedic bone regeneration purposes, such surface treatments could significantly change the static and fatigue properties of these structures and, thus, affect the application of the biomaterial as bone substitute. Therefore, the interplay between biofunctionalizing surface treatments and mechanical behavior needs to be controlled. In this paper, we studied the effects of two bio-functionalizing surface treatments, namely alkali-acid heat treatment (AlAcH) and acid-alkali (AcAl), on the static and fatigue properties of three different highly porous titanium alloy implants manufactured using selective laser melting. It was found that AlAcH treatment results in minimal mass loss. The static and fatigue properties of AlAcH specimens were therefore not much different from as-manufactured (AsM) specimens. In contrast, AcAl resulted in substantial mass loss and also in significantly less static and fatigue properties particularly for porous structures with the highest porosity. The ratio of the static mechanical properties of AcAl specimens to that of AsM specimen was in the range of 1.5-6. The fatigue lives of AcAl specimens were much more severely affected by the applied surface treatments with fatigue lives up to 23 times smaller than that of AsM specimens particularly for the porous structures with the highest porosity. In conclusion, the fatigue properties of surface treated porous titanium are dependent not only on the type of applied surface treatment but also on the porosity of the biomaterial.


Assuntos
Materiais Revestidos Biocompatíveis/síntese química , Ácido Clorídrico/química , Hidróxido de Sódio/química , Ácidos Sulfúricos/química , Titânio/química , Ligas , Módulo de Elasticidade , Calefação , Teste de Materiais , Porosidade , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA