Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 34(5): 1141-1151, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36808788

RESUMO

INTRODUCTION: Preliminary data suggest that high power short duration (HPSD) ablation for pulmonary vein isolation (PVI) are safe. Limited data are available on its effectiveness. Aim was to evaluate HPSD ablation in atrial fibrillation ablation using a novel Qdot Micro catheter. METHODS AND RESULTS: Prospective multicenter study evaluating safety and efficacy of PVI with HPSD ablation. First pass isolation (FPI) and sustained PVI was assessed. If FPI was not achieved additional ablation index (AI)-guided ablation with 45 W was performed and metrics predictive of this were determined. Sixty-five patients and 260 veins were treated. Procedural and LA dwell time was 93.9 ± 30.4 and 60.5 ± 23.1 min, respectively. FPI was achieved in 47 (72.3%) patients and 231 veins (88.8%) with an ablation duration of 4.6 ± 1.0 min. Twenty-nine veins required additional AI-guided ablation to achieve initial PVI with 24 anatomical sites ablated with the right posterior carina being the most common site (37.5%). A contact force of ≥8 g (area under the curve [AUC]: 0.81; p < 0.001) and catheter position variation of ≤1.2 mm (AUC: 0.79; p < 0.001) with HPSD were strongly predictive of not requiring additional AI-guided ablation. Out of the 260 veins, only 5 (1.9%) veins showed acute reconnection. HPSD ablation was associated with shorter procedure times (93.9 vs. 159.4 min; p < 0.001), ablation times (6.1 vs. 27.7 min; p < 0.001), and lower rates of PV reconnection (9.2% vs. 30.8%; p = 0.004) compared to moderate power cohort. CONCLUSIONS: HPSD ablation is an effective ablation modality which results in effective PVI whilst maintaining a safety profile. Its superiority needs to be evaluated in randomized controlled trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Estudos Prospectivos , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
2.
J Cardiovasc Electrophysiol ; 34(6): 1350-1359, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36598422

RESUMO

INTRODUCTION: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation. METHODS: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes. A comparison of the workflow between two different anaesthetic modalities (conscious sedation [CS] vs. general anaesthesia [GA]) was made. Procedural data were collected prospectively from two high-volume centers (Barts Heart Centre, UK and University Hospital of Zurich, Zurich). A standardized approach for catheter ablation was employed. RESULTS: A total of 35 patients had the procedure under CS and the remaining under GA. Mean procedural and fluoroscopy times were 84 ± 33 min and 1.1 min. The median duration of RF energy application was 7 (5-9.8) mins per patient. All veins were successfully isolated, and the median isolation time was 10 (7-15) seconds. Our cohort's rate of procedural complications was low, with no mortality within 30 days postprocedure. CONCLUSION: Our early experience shows that catheter ablation using the Heliostar™ technology can be performed efficiently and safely; however, long-term data is yet to be established. Low fluoroscopy requirements, short learning curves and use of this technology with CS is possible, including the use of an oesophageal temperature probe.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Europa (Continente) , Eletrodos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37001913

RESUMO

AIMS: The SMART Pass™ (SP) algorithm is a high-pass filter that aims to reduce inappropriate therapy (IT) in subcutaneous internal cardiac defibrillator (S-ICD), but SP can deactivate due to low amplitude sensed R waves or asystole. The association between IT and SP deactivation and management strategies were evaluated, hypothesizing SP deactivation increases the risk of IT and device re-programming, or lead/generator re-positioning could reduce this risk. METHODS AND RESULTS: Retrospective single-centre audit of Emblem™ S-ICD devices implanted 2016 to 2020 utilizing health records and remote monitoring data. Cox regression models evaluated associations between SP deactivation and IT. A total of 348 patients (27 ± 16.6 months follow-up) were studied: 73% primary prevention. Thirty-eight patients (11.8%) received 83 shocks with 27 patients (7.8%) receiving a total of 44 IT. Causes of IT were oversensing (98%) and aberrantly conducted atrial fibrillation (2%). SP deactivation occurred in 32 of 348 patients (9%) and was significantly associated with increased risk of IT (hazard ratio 5.36, 95% CI 2.37-12.13). SP deactivation was due to low amplitude R waves (94%), associated with a higher defibrillation threshold at implant and presence of arrhythmogenic right ventricular cardiomyopathy. No further IT occurred 16 ± 15.5 months after corrective interventions, with changing the sensing vector being successful in 59% of cases. CONCLUSION: To reduce the risk of IT, the cause of the SP deactivation should be investigated, and appropriate reprogramming, device, or lead modifications made. Utilizing the alert for SP deactivation and electrograms could pro-actively prevent IT.


Assuntos
Displasia Arritmogênica Ventricular Direita , Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Cardioversão Elétrica , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Displasia Arritmogênica Ventricular Direita/terapia
4.
J Cardiovasc Electrophysiol ; 33(8): 1747-1755, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35671359

RESUMO

AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.


Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Humanos , Punções/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
5.
Ann Vasc Surg ; 83: 305-312, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34954041

RESUMO

OBJECTIVES: The association between socioeconomic status (SES) and chronic venous insufficiency has not been rigorously studied. This study aimed to determine the influence of SES on the clinical stage of patients presenting for chronic venous disease therapy. METHODS: We performed a retrospective study of a prospectively collected data from the Vascular Quality Initiative Varicose Vein Registry at our tertiary referral center. Medical records of patients who underwent therapy for chronic venous disease between January 2015 and June 2019 were queried. SES was quantified using the neighborhood deprivation index (NDI), which summarizes 8 domains of socioeconomic deprivation and is based on census tract data derived from the patients' addresses at the time of the treatment. High NDI scores correspond with lower SES. The association between SES and severity of vein disease at presentation was assessed with bivariate analysis of variance and linear regression analysis. RESULTS: A total of 449 patients with complete SES and clinical-etiology-anatomy-pathophysiology (CEAP) class data were included in the study. The mean age was 58 years, 67% were female, and 60% were White. CEAP classes were distributed as follows C2, 22%; C3, 50%; C4, 15%; C5, 5%; and C6, 8%. Patients with lower SES (higher NDI score) tended to have a higher CEAP class at presentation (P < 0.05). SES was not associated with history of deep venous thrombosis, use of compression therapy, or venous clinical severity score. CONCLUSIONS: At our institution, patients with more advanced venous disease tended to belong to a lower SES group. This may reflect that patient with a lower SES have a longer time to presentation due to delay in seeking medical help for venous disease.


Assuntos
Varizes , Insuficiência Venosa , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Classe Social , Resultado do Tratamento , Varizes/diagnóstico por imagem , Varizes/terapia , Insuficiência Venosa/diagnóstico por imagem , Insuficiência Venosa/terapia
6.
AAPS PharmSciTech ; 23(1): 59, 2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-35059893

RESUMO

Drying of wet granules in a fluidized bed dryer is an important part of the pharmaceutical tablet manufacturing process. Complicated gas-solid flow patterns appear in the fluidized bed dryer, and interphase momentum, heat, and mass transfer happen during the drying process. A coupled computational fluid dynamics (CFD)-discrete element method (DEM)-based approach was used to model the drying process of pharmaceutical wet granules in a fluidized bed dryer. The evaporation of water from the surfaces of the particles and the cohesion force between the particles due to the formation of liquid bridges between the particles were also considered in this model. The model was validated by comparing the model predictions with the experimental data available from the literatures. The validated model was used to investigate the drying kinetics of the wet granules in the fluidized bed dryer. The results from numerical simulations showed that the dynamics and rate of increase of temperature of wet particles were considerably different from those of dry particles. Finally, the model was used to investigate the effects of inlet air velocity and inlet air temperature on the drying process. The model predicted increase in drying rate with the increase of inlet air velocity and inlet air temperature. This model can help not only to understand the multiphase multicomponent flow in fluidized bed dryer but also to optimize the drying process in the fluidized bed dryer.


Assuntos
Dessecação , Hidrodinâmica , Simulação por Computador , Comprimidos , Temperatura
7.
Rev Cardiovasc Med ; 22(2): 415-428, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34258908

RESUMO

Heart failure (HF) is a complex clinical syndrome characterised by significant morbidity and mortality worldwide. Evidence-based therapies for the management of HF include several well-established neurohormonal antagonists and antiarrhythmic drug therapy to mitigate the onset of cardiac arrhythmia. However, the degree of rate and rhythm control achieved is often suboptimal and mortality rates continue to remain high. Implantable cardioverter-defibrillators (ICDs), cardiac resynchronization (CRT), and combined (CRT-D) therapies have emerged as integral and rapidly expanding technologies in the management of select patients with heart failure with reduced ejection fraction (HFrEF). ICDs treat ventricular arrhythmia and are used as primary prophylaxis for sudden cardiac death, while CRT resynchronizes ventricular contraction to improve left ventricular systolic function. Left ventricular assist device therapy has also been shown to provide clinically meaningful survival benefits in patients with advanced HF, and His-bundle pacing has more recently emerged as a safe, viable, and promising pacing modality for patients with CRT indication. Catheter ablation is another important and well-established strategy for managing cardiac arrhythmia in HF, demonstrating superior efficacy when compared with antiarrhythmic drug therapy alone. In this article, we provide a comprehensive and in-depth evaluation of the role of implantable devices and catheter ablation in patients with HFrEF, outlining current applications, recent advances, and future directions in practice.


Assuntos
Terapia de Ressincronização Cardíaca , Ablação por Cateter , Desfibriladores Implantáveis , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Ablação por Cateter/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 44(6): 1039-1046, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33782987

RESUMO

BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2  = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2  = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , Masculino
9.
J Neurooncol ; 146(2): 229-238, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31894519

RESUMO

PURPOSE: Minimizing post-operational neurological deficits as a result of brain surgery has been one of the most pertinent endeavours of neurosurgical research. Studies have utilised fMRIs, EEGs and MEGs in order to delineate and establish eloquent areas, however, these methods have not been utilized by the wider neurosurgical community due to a lack of clinical endpoints. We sought to ascertain if there is a correlation between graph theory metrics and the neurosurgical notion of eloquent brain regions. We also wanted to establish which graph theory based nodal centrality measure performs the best in predicting eloquent areas. METHODS: We obtained diffusion neuroimaging data from the Human Connectome Project (HCP) and applied a parcellation scheme to it. This enabled us to construct a weighted adjacency matrix which we then analysed. Our analysis looked at the correlation between PageRank centrality and eloquent areas. We then compared PageRank centrality to eigenvector centrality and degree centrality to see what the best measure of empirical neurosurgical eloquence was. RESULTS: Areas that are considered neurosurgically eloquent tended to be predicted by high PageRank centrality. By using summary scores for the three nodal centrality measures we found that PageRank centrality best correlated to empirical neurosurgical eloquence. CONCLUSION: The notion of eloquent areas is important to neurosurgery and graph theory provides a mathematical framework to predict these areas. PageRank centrality is able to consistently find areas that we consider eloquent. It is able to do so better than eigenvector and degree central measures.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/cirurgia , Planejamento em Saúde/métodos , Neuroimagem/métodos , Neurocirurgia/métodos , Neurocirurgia/normas , Neoplasias Supratentoriais/cirurgia , Adulto , Idoso , Encéfalo/anatomia & histologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Vias Neurais , Neoplasias Supratentoriais/patologia , Adulto Jovem
10.
Europace ; 22(11): 1659-1671, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32862230

RESUMO

AIMS: Despite recent advances in catheter ablation for atrial fibrillation (AF), pulmonary vein reconnection (PVR), and AF recurrence remain significantly high. Ablation index (AI) is a new method incorporating contact force, time, and power that should optimize procedural outcomes. We aimed to evaluate the efficacy and safety of AI-guided catheter ablation compared to a non-AI-guided approach. METHODS AND RESULTS: A systematic search was performed on MEDLINE (via PubMED), EMBASE, COCHRANE, and European Society of Cardiology (ESC) databases (from inception to 1 July 2019). We included only studies that compared AI-guided with non-AI-guided catheter ablation of AF. Eleven studies reporting on 2306 patients were identified. Median follow-up period was 12 months. Ablation index-guided ablation had a significant shorter procedural time (141.0 vs. 152.8 min, P = 0.01; I2 = 90%), ablation time (21.8 vs. 32.0 min, P < 0.00001; I2 = 0%), achieved first-pass isolation more frequently [odds ratio (OR) = 0.09, 95%CI 0.04-0.21; 93.4% vs. 62.9%, P < 0.001; I2 = 58%] and was less frequently associated with acute PVR (OR = 0.37, 95%CI 0.18-0.75; 18.0% vs 35.0%; P = 0.006; I2 = 0%). Importantly, atrial arrhythmia relapse post-blanking was significantly lower in AI compared to non-AI catheter ablation (OR = 0.41, 95%CI 0.25-0.66; 11.8% vs. 24.9%, P = 0.0003; I2 = 35%). Finally, there was no difference in complication rate between AI and non-AI ablation, with the number of cardiac tamponade events in the AI group less being numerically lower (OR = 0.69, 95%CI 0.30-1.60, 1.6% vs. 2.5%, P = 0.39; I2 = 0%). CONCLUSIONS: These data suggest that AI-guided catheter ablation is associated with increased efficacy of AF ablation, while preserving a comparable safety profile to non-AI catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
11.
Cytopathology ; 31(6): 514-524, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32301536

RESUMO

INTRODUCTION: In the UK, guidelines from the Royal College of Pathologists (RCPath) facilitate consistent and reproducible reporting and classification of fine needle aspiration cytology (FNAC) thyroid specimens. The aim was to audit our department against RCPath guidelines to refine and improve our reporting process. METHODS: Two-cycle retrospective observational audit of all patients undergoing thyroid FNAC over a 2-year period (1 year for each cycle). Final histology was correlated. The positive predictive value (PPV) for malignant neoplastic lesions was calculated; for Thy1, Thy1c, Thy2 and Thy2c all cases without final histology were assumed to be benign, while for Thy3a, Thy3f, Thy4 and Thy5 samples the PPV calculation was based only on those cytology samples with corresponding histology. False positive and false negative cases were reviewed. RESULTS: In total, 288 cytology samples were included in the first cycle; 96 (33.3%) had corresponding histology. There were 287 samples included in the second cycle; 119 (41.5%) had follow-up histology. The rate of non-diagnostic samples (Thy1/1c) decreased from 39.6% to 30.0%. The PPV for malignant neoplastic lesions was Thy1/1c 2.6%, Thy2/2c 0.0%, Thy3a 40.0%, Thy3f 19.4%, Thy4 75.0%, Thy5 100.0% (first cycle); Thy1/1c 4.7%, Thy2/2c 0.7%, Thy3a 13.3%, Thy3f, 7.7%, Thy4, 50.0%, Thy5 100.0% (second cycle). CONCLUSIONS: Our department was able to reduce the rate of non-diagnostic FNAC samples and improve the diagnostic accuracy of FNAC. Auditing local outcomes helps refine and improve the reporting process. Review of false positive and false negative cases helps examine potential pitfalls of cytology.


Assuntos
Biópsia por Agulha Fina/métodos , Citodiagnóstico , Neoplasias da Glândula Tireoide/diagnóstico , Nódulo da Glândula Tireoide/diagnóstico , Biópsia por Agulha Fina/normas , Feminino , Guias como Assunto , Humanos , Masculino , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/classificação , Neoplasias da Glândula Tireoide/epidemiologia , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/classificação , Nódulo da Glândula Tireoide/epidemiologia , Nódulo da Glândula Tireoide/patologia
12.
Sensors (Basel) ; 20(21)2020 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-33142855

RESUMO

Detecting changes in the dielectric properties of tissues at microwave frequencies can offer simple and cost effective tools for cancer detection. These changes can be enhanced by the use of nanoparticles (NPs) that are characterised by both increased tumour uptake and high dielectric constant. This paper presents a two-port experimental setup to assess the impact of contrast enhancement on microwave signals. The study focuses on carbon nanotubes, as they have been previously shown to induce high microwave dielectric contrast. We investigate multiwall carbon nanotubes (MWNT) and their -OH functionalised version (MWNT-OH) dispersed in tissue phantoms as contrast enhancing NPs, as well as salt (NaCl) solutions as reference mixtures which can be easily dissolved inside water mixtures and thus induce dielectric contrast changes reliably. MWNT and MWNT-OH are characterised by atomic force microscopy, and their dielectric properties are measured when dispersed in 60% glycerol-water mixtures. Salt concentrations between 10 and 50 mg/mL in 60% glycerol mixtures are also studied as homogeneous samples known to affect the dielectric constant. Contrast enhancement is then evaluated using a simplified two-port microwave system to identify the impact on microwave signals with respect to dielectric contrast. Numerical simulations are also conducted to compare results with the experimental findings. Our results suggest that this approach can be used as a reliable method to screen and assess contrast enhancing materials with regards to a microwave system's ability to detect their impact on a target.

13.
Sensors (Basel) ; 20(3)2020 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-32033241

RESUMO

We present an initial experimental validation of a microwave tomography (MWT) prototypefor brain stroke detection and classification using the distorted Born iterative method, two-stepiterative shrinkage thresholding (DBIM-TwIST) algorithm. The validation study consists of firstpreparing and characterizing gel phantoms which mimic the structure and the dielectric propertiesof a simplified brain model with a haemorrhagic or ischemic stroke target. Then, we measure theS-parameters of the phantoms in our experimental prototype and process the scattered signals from 0.5to 2.5 GHz using the DBIM-TwIST algorithm to estimate the dielectric properties of the reconstructiondomain. Our results demonstrate that we are able to detect the stroke target in scenarios where theinitial guess of the inverse problem is only an approximation of the true experimental phantom.Moreover, the prototype can differentiate between haemorrhagic and ischemic strokes based on theestimation of their dielectric properties.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento de Micro-Ondas , Micro-Ondas , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia/métodos , Algoritmos , Isquemia Encefálica/diagnóstico por imagem , Géis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imagens de Fantasmas , Reprodutibilidade dos Testes , Espalhamento de Radiação , Processamento de Sinais Assistido por Computador
14.
J Pak Med Assoc ; 70(12(A)): 2260-2262, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33475608

RESUMO

In 2015, Karachi saw its first ever epidemic of severe heatrelated illnesses that resulted in an extraordinary number of hospital admissions, especially in the intensive care, for fatal heat stroke within-hospital mortality of 3.7%.We conducted this study to elucidate the patient-related factors that lead to an increase in hospital admissions with heat-related illnesses in a tertiary care hospital. It was a descriptive case series conducted in the department of medicine at the Aga Khan University in June 2015. A total of 134 patients were admitted with heat-related illnesses of which 76(56.7%) were males. The mean age of the patients was 66 ±14.5 years. Heatstroke was present in 86 (64.2%) patients, followed by heat exhaustion in 48 (35.8%) and in-hospital mortality from heat-related illnesses was 5(3.7%). Hypertension (OR 2(95 % CI 1.0, 3.6) and insufficient sleep or food or water intake (OR 1.7(95 % CI 0.8, 3.8) was associated with severe heat-related illnesses. The effects remained even after adjusting for type and area of residence.


Assuntos
Transtornos de Estresse por Calor , Golpe de Calor , Idoso , Idoso de 80 Anos ou mais , Feminino , Transtornos de Estresse por Calor/epidemiologia , Golpe de Calor/epidemiologia , Mortalidade Hospitalar , Hospitais , Temperatura Alta , Humanos , Masculino , Pessoa de Meia-Idade
15.
J Cardiovasc Electrophysiol ; 30(12): 2900-2906, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31578806

RESUMO

INTRODUCTION: Implantable loop recorders (ILR) are predominantly implanted by cardiologists in the catheter laboratory. We developed a nurse-delivered service for the implantation of LINQ (Medtronic; Minnesota) ILRs in the outpatient setting. This study compared the safety and cost-effectiveness of the introduction of this nurse-delivered ILR service with contemporaneous physician-led procedures. METHODS: Consecutive patients undergoing an ILR at our institution between 1st July 2016 and 4th June 2018 were included. Data were prospectively entered into a computerized database, which was retrospectively analyzed. RESULTS: A total of 475 patients underwent ILR implantation, 271 (57%) of these were implanted by physicians in the catheter laboratory and 204 (43%) by nurses in the outpatient setting. Six complications occurred in physician-implants and two in nurse-implants (P = .3). Procedural time for physician-implants (13.4 ± 8.0 minutes) and nurse-implants (14.2 ± 10.1 minutes) were comparable (P = .98). The procedural cost was estimated as £576.02 for physician-implants against £279.95 with nurse-implants, equating to a 57.3% cost reduction. In our center, the total cost of ILR implantation in the catheter laboratory by physicians was £10 513.13 p.a. vs £6661.55 p.a. with a nurse-delivered model. When overheads for running, cleaning, and maintaining were accounted for, we estimated a saving of £68 685.75 was performed by moving to a nurse-delivered model for ILR implants. Over 133 catheter laboratory and implanting physician hours were saved and utilized for other more complex procedures. CONCLUSION: ILR implantation in the outpatient setting by suitably trained nurses is safe and leads to significant financial savings.


Assuntos
Assistência Ambulatorial/economia , Custos de Cuidados de Saúde , Monitorização Ambulatorial/economia , Monitorização Ambulatorial/enfermagem , Papel do Profissional de Enfermagem , Papel do Médico , Tecnologia de Sensoriamento Remoto/economia , Tecnologia de Sensoriamento Remoto/enfermagem , Adulto , Idoso , Competência Clínica/economia , Redução de Custos , Análise Custo-Benefício , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Valor Preditivo dos Testes , Tecnologia de Sensoriamento Remoto/instrumentação , Estudos Retrospectivos , Fluxo de Trabalho
16.
J Cardiovasc Electrophysiol ; 30(3): 357-365, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30556609

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. METHODS: Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. RESULTS: One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 Ω, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group ( P = 0.186). CONCLUSION: High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Potenciais de Ação , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Inglaterra , Feminino , Frequência Cardíaca , Humanos , Masculino , Duração da Cirurgia , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Europace ; 21(4): 616-625, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30500897

RESUMO

AIMS: Differences of action potential duration (APD) in regions of myocardial scar and their borderzones are poorly defined in the intact human heart. Heterogeneities in APD may play an important role in the generation of ventricular tachycardia (VT) by creating regions of functional block. We aimed to investigate the transmural and planar differences of APD in patients admitted for VT ablation. METHODS AND RESULTS: Six patients (median age 53 years, five male); (median ejection fraction 35%), were studied. Endocardial (Endo) and epicardial (Epi) 3D electroanatomic mapping was performed. A bipolar voltage of <0.5 mV was defined as dense scar, 0.5-1.5 mV as scar borderzone, and >1.5 mV as normal. Decapolar catheters were positioned transmurally across the scar borderzone to assess differences of APD and repolarization time (RT) during restitution pacing from Endo and Epi. Epi APD was 173 ms in normal tissue vs. 187 ms at scar borderzone and 210 ms in dense scar (P < 0.001). Endocardial APD was 210 ms in normal tissue vs. 222 ms in the scar borderzone and 238 ms in dense scar (P < 0.01). This resulted in significant transmural RT dispersion (ΔRT 22 ms across dense transmural scar vs. 5 ms in normal transmural tissue, P < 0.001), dependent on the scar characteristics in the Endo and Epi, and the pacing site. CONCLUSION: Areas of myocardial scar have prolonged APD compared with normal tissue. Heterogeneity of regional transmural and planar APD result in localized dispersion of repolarization, which may play an important role in initiating VT.


Assuntos
Potenciais de Ação , Ablação por Cateter , Cicatriz/fisiopatologia , Endocárdio/fisiopatologia , Pericárdio/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatias/complicações , Cicatriz/etiologia , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Miocardite/complicações , Miocárdio , Recidiva , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
19.
J Pak Med Assoc ; 69(1): 72-76, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30623916

RESUMO

OBJECTIVE: To identify potential shortcoming(s) in relevance to patient safety culture at dental clinics. METHODS: The cross-sectional study was conducted from March to June 2016 at two clinics of a dental teaching college in Riyadh, Saudi Arabia, and comprised subjects who had either direct or indirect contact with patients in the dental clinics. The subjects were handed over a questionnaire based on the Patient Safety Culture Hospital Questionnaire. SPSS 21 was used for data analysis. RESULTS: Of the 149 subjects, 96(64.4%) were male, and 130(87%) were in direct contact with patients, while 19(13%) were in indirect contact. Overall, 52(35%) subjects stated that their unit did not have enough staff to handle the workload, and 71(47.7%) said that not encountering serious errors in their unit was pure luck. An encouraging finding was that 104(69.8%) subjects said their managers appreciated them when they followed the established patient safety protocol. Conclusion: There was a variation in the perception of patient safety culture among professionals.


Assuntos
Clínicas Odontológicas , Educação em Odontologia , Segurança do Paciente/normas , Qualidade da Assistência à Saúde , Gestão da Segurança , Universidades , Adulto , Atitude do Pessoal de Saúde , Estudos Transversais , Clínicas Odontológicas/métodos , Clínicas Odontológicas/normas , Educação em Odontologia/métodos , Educação em Odontologia/normas , Feminino , Humanos , Masculino , Cultura Organizacional , Paquistão , Melhoria de Qualidade , Gestão da Segurança/métodos , Gestão da Segurança/organização & administração , Percepção Social , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA