RESUMO
Risk classification and clinical management of the DNA variant of unknown significance(VUS)in BRCA 1/2 remains unestablished. The Japanese hereditary breast and ovarian cancer(HBOC)consortium and myriad genetics reported that the VUS rate of BRCA is 6.5% in Japanese patients, but is <2% in the USA. The types of mutation supposedly differ between Asian and European ethnicities. Breast-conserving therapy(BCT)is not recommended in HBOC breast cancer, according to the 2017 Japanese guidelines by the Ministry of Health, because of the risk of ipsilateral breast recurrence(IBR)and carcinogenesis by radiation. In our hospital, we recommend an initial mastectomy and breast reconstruction with an implant for patients with HBOC breast cancer, considering future surgery on the contralateral side and symmetry of the reconstructed breast. However, the risk of IBR after BCT is not significantly high in patients with HBOC breast cancer, and BCT is a reasonable option even for definite HBOC breast cancer under low risk conditions. Hence, BCT is feasible for treating breast cancer in carriers of VUS following decision-making and informed consent from the patients.
Assuntos
Neoplasias da Mama , Neoplasias da Mama/genética , Neoplasias da Mama/cirurgia , Feminino , Humanos , Japão , Mastectomia , Mastectomia Segmentar , Recidiva Local de NeoplasiaRESUMO
Background and study aims Snare devices play an important role in treatment of intestinal polyps. However, there are no objective measurements for the characteristics of the various types of snare devices. Materials and methods Seven types of snare devices from four manufacturers were evaluated based on original measurements. The evaluated factors were stiffness, cutting quality, and change in force required for cutting depending on sheath shape. The latter two factors were evaluated by measuring the force required to cut 20â% gelatin cylinders, which simulated intestinal polyps. The cutting sharpness was evaluated by observing the sectional surface of cut gelatin cylinders using a stereomicroscope. The correlations between these measurements and characteristics of the snare devices were investigated. Results A strong positive correlation, with an R 2 value of 0.863, was shown between the force required to cut gelatin cylinders and loop wire diameter. Loop wire diameter also had a strong correlation, with an R 2 value of 0.7997, with the change in force required for cutting gelatin cylinders depending on sheath shape. No correlations were detected between loop stiffness and characteristics of snare devices. The edge-enhanced image revealed that the rougher surfaces of the gelatin cylinders were cut by snares with a thicker diameter. Conclusions Thinner loop wire may provide higher performance in cold snare polypectomy in an experimental model.