Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38782788

RESUMO

OBJECTIVES: To assess the role of CT venography (CTV) in the diagnosis of venous thromboembolism (VTE) during the postpartum period. MATERIALS AND METHODS: This multicenter prospective cohort study was conducted between April 2016 and April 2020 in 14 university hospitals. All women referred for CT pulmonary angiography (CTPA) for suspected pulmonary embolism (PE) within the first 6 weeks postpartum were eligible. All CTPAs were performed on multidetector CT machines with the usual parameters and followed by CTV of the abdomen, pelvis, and proximal lower limbs. On-site reports were compared to expert consensus reading, and the added value of CTV was assessed for both. RESULTS: The final study population consisted of 123 women. On-site CTPA reports mentioned PE in seven women (7/123, 5.7%), all confirmed following expert consensus reading, three involving proximal pulmonary arteries and four limited to distal arteries. Positive CTV was reported on-site in nine women, five of whom had negative and two indeterminate CTPAs, bringing the VTE detection rate to 11.4% (14/123) (95%CI: 6.4-18.4, p = 0.03). Expert consensus reading confirmed all positive on-site CTV results, but detected a periuterine vein thrombosis in an additional woman who had a negative CTPA, increasing the VTE detection rate to 12.2% (15/123) (95%CI: 7.0-19.3, p = 0.008). Follow-up at 3 months revealed no adverse events in this woman, who was left untreated. Median Dose-Length-Product was 117 mGy.cm for CTPA and 675 mGy.cm for CTPA + CTV. CONCLUSION: Performing CTV in women suspected of postpartum PE doubles the detection of venous thromboembolism, at the cost of increased radiation exposure. CLINICAL RELEVANCE STATEMENT: CTV can help in the decision-making process concerning curative anticoagulation in women with suspected postpartum PE, particularly those whose CTPA results are indeterminate or whose PE is limited to the subsegmental level. KEY POINTS: Postpartum women are at risk of pulmonary embolism, and CT pulmonary angiography can give equivocal results. CT venography (CTV) positivity increased the venous thromboembolism detection rate from 5.7 to 11.4%. CTV may help clinical decision-making, especially in women with indeterminate CTPA results or subsegmental emboli.

2.
J Cereb Blood Flow Metab ; : 271678X241232197, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38340789

RESUMO

Preterm birth is associated with cerebrovascular development disruption and can induce white matter injuries (WMI). Transfontanellar ultrasound Doppler is the most widely used clinical imaging technique to monitor neonatal cerebral vascularisation and haemodynamics based on vascular indexes such as the resistivity index (RI); however, it has poor predictive value for brain damage. Indeed, these RI measurements are currently limited to large vessels, leading to a very limited probing of the brain's vascularisation, which may hinder prognosis. Here we show that ultrafast Doppler imaging (UfD) enables simultaneous quantification, in the whole field of view, of the local RI and vessel diameter, even in small vessels. Combining both pieces of information, we defined two new comprehensive resistivity parameters of the vascular trees. First, we showed that our technique is more sensitive in the early characterisation of the RI modifications between term and preterm neonates and for the first time we could show that the RI depends both on the vessel diameter and vascular territory. We then showed that our parameters can be used for early prediction of WMI. Our results demonstrate the potential of UfD to provide new biomarkers and pave the way for continuous monitoring of neonatal brain resistivity.

3.
Eur J Obstet Gynecol Reprod Biol ; 298: 91-97, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38735121

RESUMO

OBJECTIVE: Show a prognostic value of brain changes in fetuses with intra uterine growth restriction (IUGR) on early neonatal outcome. STUDY DESIGN: We prospectively recruited pregnant women whose fetuses presented fetal weight < 5th centile. A brain MRI was performed between 28 and 32 weeks of gestation (WG). Several brain biometrics were measured (as fronto-occipital diameter (FOD) and transverse cerebellar diameter (TCD)). Neonatal prognosis was evaluated according to a composite criterion. RESULTS: Of the 78 patients included, 62 had a fetal brain MRI. The mean centile value of FOD was lower in the unfavorable outcome group (n = 9) compared to the favorable outcome group (n = 53) (24.5 ± 16.8 vs. 8.6 ± 13.2, p = 0.004). The ROC curve for predicting risk of unfavorable neonatal outcome based on FOD presented an area under the curve of 0.81 (95 % CI, [0.63---0.99]) and a threshold determined at the 3rd centile was associated with sensitivity of 0.78 and a specificity of 0.89. In multivariate analysis, a FOD less than the 3rd centile was significantly associated with an unfavorable neonatal risk. There also was a reduction in TCD (25.5 ± 21.5 vs. 10.4 ± 10.4, p = 0.03) in the unfavorable neonatal outcome group. CONCLUSION: We found an association between a reduction in FOD and TCD in fetal MRIs conducted between 28 and 32 WG in fetuses monitored for IUGR with an unfavorable neonatal outcome. Our results suggest that these biometric changes could constitute markers of poor neonatal prognosis.


Assuntos
Encéfalo , Retardo do Crescimento Fetal , Imageamento por Ressonância Magnética , Humanos , Feminino , Gravidez , Retardo do Crescimento Fetal/diagnóstico por imagem , Estudos Prospectivos , Adulto , Prognóstico , Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Biometria , Recém-Nascido
4.
Neonatology ; 121(4): 478-484, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38522417

RESUMO

INTRODUCTION: Neonatal portal vein thrombosis (PVT) is frequently related to umbilical venous catheterization (UVC), but risk factors remain unclear. This study aims to analyze the variables associated to PVT in near- to full-term newborns with UVC, with a focus on newborns exposed to controlled therapeutic hypothermia (CTH) for hypoxic ischemic encephalopathy (HIE). METHODS: This is retrospective cohort study of infants delivered at or after 36 weeks and with a birthweight over 1,500 g. All infants were assessed for UVC location and PVT using ultrasonography performed between day 5 and day 10 after catheterization. RESULTS: Among 213 eligible patients, PVT was diagnosed in 57 (27%); among them, 54 (95%) were localized in the left portal vein branch. With all significant factors in univariate analysis considered, higher gestational age at birth (adjusted OR 1.35; 95% CI: 1.12-1.64, p = 0.002) and duration of UVC placement (adjusted OR 1.36; 95% CI: 1.11-1.67, p = 0.004) were the main risk factors of PVT. Among 87 infants who were cooled for HIE, 31 (36%) had PVT compared to 26 (21%) in infants without CTH. Using a multivariate model including variables linked to treatment procedures only, an increased PVT incidence was statistically associated with UVC duration (adjusted OR 1.33; 95% CI: 1.08; 1.63, p = 0.01) and CTH (adjusted OR 1.94; 95% CI: 1.04-3.65, p = 0.04). CONCLUSION: Left PVT was frequently observed in near- to full-term neonates with UVC. Among factors linked to treatment procedures, both duration of UVC and CTH exposure for HIE were found to be independent risk factors of PVT.


Assuntos
Asfixia Neonatal , Idade Gestacional , Hipotermia Induzida , Veia Porta , Veias Umbilicais , Trombose Venosa , Humanos , Recém-Nascido , Estudos Retrospectivos , Feminino , Veia Porta/diagnóstico por imagem , Veias Umbilicais/diagnóstico por imagem , Masculino , Trombose Venosa/etiologia , Trombose Venosa/epidemiologia , Fatores de Risco , Asfixia Neonatal/terapia , Asfixia Neonatal/complicações , Hipotermia Induzida/efeitos adversos , Hipóxia-Isquemia Encefálica/etiologia , Hipóxia-Isquemia Encefálica/terapia , Ultrassonografia , Cateterismo Periférico/efeitos adversos
5.
Sci Rep ; 14(1): 11827, 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38782968

RESUMO

Cerebral white matter damage (WMD) is the most frequent brain lesion observed in infants surviving premature birth. Qualitative B-mode cranial ultrasound (cUS) is widely used to assess brain integrity at bedside. Its limitations include lower discriminatory power to predict long-term outcomes compared to magnetic resonance imaging (MRI). Shear wave elastography (SWE), a promising ultrasound imaging modality, might improve this limitation by detecting quantitative differences in tissue stiffness. The study enrolled 90 neonates (52% female, mean gestational age = 30.1 ± 4.5 weeks), including 78 preterm and 12 term controls. Preterm neonates underwent B-mode and SWE assessments in frontal white matter (WM), parietal WM, and thalami on day of life (DOL) 3, DOL8, DOL21, 40 weeks, and MRI at term equivalent age (TEA). Term infants were assessed on DOL3 only. Our data revealed that brain stiffness increased with gestational age in preterm infants but remained lower at TEA compared to the control group. In the frontal WM, elasticity values were lower in preterm infants with WMD detected on B-mode or MRI at TEA and show a good predictive value at DOL3. Thus, brain stiffness measurement using SWE could be a useful screening method for early identification of preterm infants at high WMD risk.Registration numbers: EudraCT number ID-RCB: 2012-A01530-43, ClinicalTrial.gov number NCT02042716.


Assuntos
Técnicas de Imagem por Elasticidade , Recém-Nascido Prematuro , Substância Branca , Humanos , Técnicas de Imagem por Elasticidade/métodos , Feminino , Recém-Nascido , Masculino , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Idade Gestacional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA