Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(5): 814-822, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37676058

RESUMO

BACKGROUND: Indications and outcomes for percutaneous ventricular assist device (pVAD) use in surgically ineligible patients undergoing percutaneous coronary intervention (PCI) remain poorly characterized. AIMS: We sought to describe the use and timing of pVAD and outcome in surgically ineligible patients. METHODS: Among 726 patients enrolled in the prospective OPTIMUM study, clinical and health status outcomes were assessed in patients who underwent pVAD-assisted PCI and those without pVAD. RESULTS: Compared with patients not receiving pVAD (N = 579), those treated with pVAD (N = 142) more likely had heart failure, lower left ventricular ejection fraction (30.7 ± 13.6 vs. 45.9 ± 15.5, p < 0.01), and higher STS 30-day predicted mortality (4.2 [2.1-8.0] vs. 3.3 [1.7-6.6], p = 0.01) and SYNTAX scores (36.1 ± 12.2, vs. 31.5 ± 12.1, p < 0.01). While the pVAD group had higher in-hospital (5.6% vs. 2.2%, p = 0.046), 30-day (9.0% vs. 4.0%, p = 0.01) and 6-month (20.4% vs. 11.7%, p < 0.01) mortality compared to patients without pVAD, this difference appeared to be largely driven by significantly higher mortality among the 20 (14%) patients with unplanned pVAD use (30% in-hospital mortality with unplanned PVAD vs. 1.6% with planned, p < 0.01; 30-day mortality, 38.1% vs. 4.5%, p < 0.01). The degree of 6-month health status improvement among survivors was similar between groups. CONCLUSION: Surgically ineligible patients with pVAD-assisted PCI had more complex baseline characteristics compared with those without pVAD. Higher mortality in the pVAD group appeared to be driven by very poor outcomes by patients with unplanned, rescue pVAD.


Assuntos
Coração Auxiliar , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Volume Sistólico , Estudos Prospectivos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Choque Cardiogênico/terapia
2.
Am Heart J ; 228: 57-64, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32828047

RESUMO

AIMS: Data regarding outcomes for patients with severe aortic stenosis (AS) with concomitant aortic insufficiency (AI), undergoing transcatheter aortic valve replacement (TAVR) are limited. This study aimed to analyze the prevalence of severe AS with concomitant AI among patients undergoing TAVR and outcomes of TAVR in this patient group. METHODS AND RESULTS: Using data from the STS/ACC-TVT Registry, we identified patients with severe AS with or without concomitant AI who underwent TAVR between 2011 and 2016. Patients were categorized based on the severity of pre-procedural AI. Multivariable proportional hazards regression models were used to examine all-cause mortality and heart failure (HF) hospitalization at 1-year. Among 54,535 patients undergoing TAVR, 42,568 (78.1%) had severe AS with concomitant AI. Device success was lower in patients with severe AS with concomitant AI as compared with isolated AS. The presence of baseline AI was associated with lower 1 year mortality (HR 0.94 per 1 grade increase in AI severity; 95% CI, 0.91-0.98, P < .001) and HF hospitalization (HR 0.87 per 1 grade increase in AI severity; 95% CI, 0.84-0.91, P < .001). CONCLUSIONS: Severe AS with concomitant AI is common among patients undergoing TAVR, and is associated with lower 1 year mortality and HF hospitalization. Future studies are warranted to better understand the mechanisms underlying this benefit. SHORT ABSTRACT: In this nationally representative analysis from the United States, 78.1% of patients undergoing TAVR had severe AS with concomitant AI. Device success was lower in patients with severe AS with concomitant AI as compared with isolated AS. The presence of baseline AI was associated with lower 1 year mortality (HR 0.94 per 1 grade increase in AI severity; 95% CI, 0.91-0.98, P < .001) and HF hospitalization (HR 0.87 per 1 grade increase in AI severity; 95% CI, 0.84-0.91, P < .001).


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Valva Aórtica , Insuficiência Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Próteses Valvulares Cardíacas , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Sistema de Registros/estatística & dados numéricos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estados Unidos/epidemiologia
3.
Catheter Cardiovasc Interv ; 96(2): E187-E195, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31566873

RESUMO

OBJECTIVES: We undertook an independent bench test assessing the performance of the TRUE dilatation (TD) balloon valvuloplasty catheter (Bard Vascular Inc., Tempe, AZ) beyond its rated burst pressure (RBP). BACKGROUND: The TD balloon has a RBP of six atmospheres (atm), and its performance beyond this RBP is poorly understood. Techniques such as bioprosthetic valve fracture require inflation pressures beyond manufacturer recommendations. METHODS: A 20, 22, 24, 26, and 28 mm TD balloon were inflated to increasing pressures in increments of 3 atm until balloon failure. Measurements were performed at the proximal, middle, and distal balloon segments with scientific digital calipers. Z-MED balloons (Braun Interventional Systems Inc., Bethlehem, PA) were used as a comparator. RESULTS: The mean diameter at the middle of the 20, 22, 24, 26, and 28 mm TD balloon at nominal pressure (3 atm) was 20.02 ± 0.09, 21.77 ± 0.07, 23.9 ± 0.06, 25.82 ± 0.08, and 27.62 ± 0.08 mm, respectively. The maximal mean diameter at the middle of the 20, 22, 24, 26, and 28 mm TD balloon was 20.39 ± 0.03 mm (15 atm), 22.35 ± 0.03 mm (15 atm), 24.55 ± 0.02 mm (15 atm), 26.48 ± 0.02 mm (12 atm), and 28.39 ± 0.03 mm (12 atm), respectively. The 20/22/24 and 26/28 mm balloon failed when inflated beyond 15 atm and 12 atm, respectively. Failure was due to either leakage or longitudinal balloon rupture. TD balloons were more likely to maintain dimensions similar to their labeled size and less likely to fail at higher pressures as compared to Z-MED balloons. CONCLUSION: The TD balloon catheter maintains a similar diameter to its labeled size, when inflated beyond its RBP. When inflated beyond 12 atm, the TD balloon can fail due to either leakage or rupture. This has implications for percutaneous structural heart interventions.


Assuntos
Valvuloplastia com Balão/instrumentação , Cateteres Cardíacos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Pressão
4.
Curr Cardiol Rep ; 20(10): 95, 2018 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-30135999

RESUMO

PURPOSE OF REVIEW: This review aims to summarize data regarding bioprosthetic valve fracture (BVF), a novel technique that involves fracturing the surgical valve sewing ring to allow for further expansion of the transcatheter heart valve in patients undergoing valve in valve transcatheter aortic valve replacement (VIV TAVR). RECENT FINDINGS: Bench testing and clinical experience have demonstrated that most, but not all, bioprosthetic surgical valves can be fractured. BVF in patients with small- and intermediate-sized surgical valves results in a lower residual valve gradient and larger final valve effective orifice area as compared with standard VIV TAVR. However, whether patients with larger bioprothetic valves benefit from BVF, and whether the hemodynamic benefits of BVF translate into improved clinical outcomes, is unknown. BVF improves the hemodynamic results of VIV TAVR in small surgical valves. However, further research is needed to determine whether BVF is beneficial for patients with larger surgical valves, and whether the hemodynamic benefits of BVF result in improved clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Echocardiography ; 34(1): 128-130, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27862233

RESUMO

Left atrial appendage closure with the WATCHMAN device is an alternative to chronic oral anticoagulation for thromboembolic prophylaxis in atrial fibrillation patients. Left atrial device-related thrombus (DRT) has been described in the first year after implant with an incidence of ~6%. A 79-year-old man underwent WATCHMAN device placement in 2006. Routine protocol specified follow-up transesophageal echocardiograms (TEE) at 6 weeks, 6 months, and 1 year following implant showed no evidence for DRT or peri-device flow. A decade after device implant, the patient presented with severe symptomatic aortic stenosis and underwent repeat TEE, which revealed a 21 mm × 18 mm DRT on the LA aspect of the WATCHMAN device. He was prescribed apixaban 5 mg po BID. A TEE performed 111 days later demonstrated marked diminution in the DRT (9 mm in diameter). This case demonstrates that WATCHMAN DRT may occur late following implantation.


Assuntos
Apêndice Atrial/cirurgia , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Dispositivos de Proteção Embólica/efeitos adversos , Previsões , Cardiopatias/diagnóstico , Trombose/diagnóstico , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Seguimentos , Cardiopatias/etiologia , Humanos , Masculino , Falha de Prótese , Trombose/etiologia
6.
Catheter Cardiovasc Interv ; 86(4): 768-72, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25640823

RESUMO

Thoracic endovascular aortic repair (TEVAR) of acute ascending aortic pathology is feasible; however, the unique features of this aortic segment in addition to access challenges restricts its use to a select, high-risk subset of patients. With the advent of TAVR, large device delivery using transapical access has become a well-defined technique. We report a patient with critical aortic stenosis and an acute ascending aortic penetrating ulcer with tamponade managed successfully utilizing transapical TAVR and TEVAR. To our knowledge, this is the first reported case of a hybrid single-stage TAVR and ascending aortic TEVAR using transapical access.


Assuntos
Aorta/cirurgia , Doenças da Aorta/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Substituição da Valva Aórtica Transcateter/métodos , Úlcera/cirurgia , Idoso de 80 Anos ou mais , Doenças da Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Cateterismo Cardíaco/métodos , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/cirurgia , Terapia Combinada , Estado Terminal , Ecocardiografia Transesofagiana/métodos , Procedimentos Endovasculares/métodos , Feminino , Fluoroscopia/métodos , Seguimentos , Humanos , Imageamento Tridimensional , Desenho de Prótese , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Úlcera/diagnóstico por imagem
7.
Ann Vasc Surg ; 29(2): 362.e3-4, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25462540

RESUMO

Radial artery pseudoaneurysms occur infrequently and are most commonly associated with medical interventions such as arterial lines or cardiac catheterization procedures. Animal bites, particularly cat bites, as a cause for radial artery pseudoaneurysms are extremely rare with only 1 previously reported case in the literature. A unique case of digital micro emboli from a radial artery pseudoaneurysm caused by a cat bite to the wrist is presented.


Assuntos
Falso Aneurisma/cirurgia , Mordeduras e Picadas/complicações , Artéria Radial/lesões , Falso Aneurisma/etiologia , Animais , Gatos , Feminino , Humanos , Pessoa de Meia-Idade , Artéria Radial/cirurgia , Traumatismos do Punho/etiologia
8.
Ann Surg ; 260(2): 402-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24368640

RESUMO

OBJECTIVE: To evaluate angiographic and clinical outcomes associated with open and closed dissection tunnel endoscopic vein harvesting (EVH) devices. BACKGROUND: A previous PREVENT-IV (PRoject of Ex-vivo Vein graft ENgineering via Transfection IV) analysis reported that EVH for coronary artery bypass graft surgery was associated with worse outcomes than with traditional vein harvesting; however, outcomes by EVH device type were not available. METHODS: Using data from the PREVENT-IV trial, we compared 1549 patients from 75 surgical sites who underwent EVH with open (n = 390) or closed (n = 1159) harvest tunnel devices. Outcomes included the incidence of vein graft failure at 12 to 18 months and a composite of death, myocardial infarction, and revascularization through 5 years. RESULTS: Among patients undergoing open and closed tunnel EVH, no difference in the per-patient incidence of vein graft failure (43.8% vs 47.1%; adjusted odds ratio, 0.91; 95% confidence interval, 0.53-1.55; P = 0.724) or per-graft incidence of vein graft failure (25.5% vs 25.9%; adjusted odds ratio, 0.96; 95% confidence interval, 0.59-1.55; P = 0.847) was observed. At 5 years, no difference was observed in the primary composite clinical outcome between patients who underwent open and closed system EVH (21.5% vs 23.9%; adjusted hazard ratio, 0.85; 95% confidence interval, 0.66-1.10; P = 0.221). CONCLUSIONS: No differences in angiographic or clinical outcomes were observed among patients who underwent open versus closed tunnel endoscopic harvesting for coronary bypass surgery. These findings suggest that the risks associated with EVH that were reported in a previous PREVENT-IV analysis are not related to a specific EVH device.


Assuntos
Ponte de Artéria Coronária , Endoscopia/instrumentação , Veia Safena/transplante , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Método Duplo-Cego , Endoscopia/métodos , Feminino , Oclusão de Enxerto Vascular/epidemiologia , Sobrevivência de Enxerto , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Estados Unidos/epidemiologia , Procedimentos Cirúrgicos Vasculares
9.
J Am Coll Cardiol ; 83(17): 1656-1668, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38658105

RESUMO

BACKGROUND: Tricuspid valve annuloplasty (TA) during mitral valve repair (MVr) is associated with increased risk of permanent pacemaker (PPM) implantation, but the magnitude of risk and long-term clinical consequences have not been firmly established. OBJECTIVES: This study assesses the incidence rates of PPM implantation after isolated MVr and following MVr with TA as well as the associated long-term clinical consequences of PPM implantation. METHODS: State-mandated hospital discharge databases of New York and California were queried for patients undergoing MVr (isolated or with concomitant TA) between 2004 and 2019. Patients were stratified by whether or not they received a PPM within 90 days of index surgery. After weighting by propensity score, survival, heart failure hospitalizations (HFHs), endocarditis, stroke, and reoperation were compared between patients with or without PPM. RESULTS: A total of 32,736 patients underwent isolated MVr (n = 28,003) or MVr + TA (n = 4,733). Annual MVr + TA volumes increased throughout the study period (P < 0.001, trend), and PPM rates decreased (P < 0.001, trend). The incidence of PPM implantation <90 days after surgery was 7.7% for MVr and 14.0% for MVr + TA. In 90-day conditional landmark-weighted analyses, PPMs were associated with reduced long-term survival among MVr (HR: 1.96; 95% CI: 1.75-2.19; P < 0.001) and MVr + TA recipients (HR: 1.65; 95% CI: 1.28-2.14; P < 0.001). In both surgical groups, PPMs were also associated with an increased risk of HFH (HR: 1.56; 95% CI: 1.27-1.90; P < 0.001) and endocarditis (HR: 1.95; 95% CI: 1.52-2.51; P < 0.001), but not with stroke or reoperation. CONCLUSIONS: Compared to isolated MVr, adding TA to MVr was associated with a higher risk of 90-day PPM implantation. In both surgical groups, PPM implantation was associated with an increase in mortality, HFH, and endocarditis.


Assuntos
Marca-Passo Artificial , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/cirurgia , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estudos Retrospectivos , Anuloplastia da Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
10.
Circulation ; 125(6): 749-56, 2012 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-22238227

RESUMO

BACKGROUND: Vein graft failure (VGF) is common after coronary artery bypass graft surgery, but its relationship with long-term clinical outcomes is unknown. In this retrospective analysis, we examined the relationship between VGF, assessed by coronary angiography 12 to 18 months after coronary artery bypass graft surgery, and subsequent clinical outcomes. METHODS AND RESULTS: Using the Project of Ex Vivo Vein Graft Engineering via Transfection IV (PREVENT IV) trial database, we studied data from 1829 patients who underwent coronary artery bypass graft surgery and had an angiogram performed up to 18 months after surgery. The main outcome measure was death, myocardial infarction, and repeat revascularization through 4 years after angiography. VGF occurred in 787 of 1829 patients (43%). Clinical follow-up was completed in 97% of patients with angiographic follow-up. The composite of death, myocardial infarction, or revascularization occurred more frequently among patients who had any VGF compared with those who had none (adjusted hazard ratio, 1.58; 95% confidence interval, 1.21-2.06; P=0.008). This was due mainly to more frequent revascularization with no differences in death (adjusted hazard ratio, 1.04; 95% confidence interval, 0.71-1.52; P=0.85) or death or myocardial infarction (adjusted hazard ratio, 1.08; 95% confidence interval, 0.77-1.53; P=0.65). CONCLUSIONS: VGF is common after coronary artery bypass graft surgery and is associated with repeat revascularization but not with death and/or myocardial infarction. Further investigations are needed to evaluate therapies and strategies for decreasing VGF to improve outcomes in patients undergoing coronary artery bypass graft surgery.


Assuntos
Ponte de Artéria Coronária , Veia Safena/transplante , Idoso , Ensaios Clínicos Fase III como Assunto/estatística & dados numéricos , Angiografia Coronária , Método Duplo-Cego , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto/estatística & dados numéricos , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/cirurgia , Modelos de Riscos Proporcionais , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Recidiva , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Análise de Sobrevida , Falha de Tratamento , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
JAMA ; 309(13): 1368-78, 2013 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-23549582

RESUMO

IMPORTANCE: Infections due to Staphylococcus aureus are serious complications of cardiothoracic surgery. A novel vaccine candidate (V710) containing the highly conserved S. aureus iron surface determinant B is immunogenic and generally well tolerated in volunteers. OBJECTIVE: To evaluate the efficacy and safety of preoperative vaccination in preventing serious postoperative S. aureus infection in patients undergoing cardiothoracic surgery. DESIGN, SETTING, AND PARTICIPANTS: Double-blind, randomized, event-driven trial conducted between December 2007 and August 2011 among 8031 patients aged 18 years or older who were scheduled for full median sternotomy within 14 to 60 days of vaccination at 165 sites in 26 countries. INTERVENTION: Participants were randomly assigned to receive a single 0.5-mL intramuscular injection of either V710 vaccine, 60 µg (n = 4015), or placebo (n = 4016). MAIN OUTCOME MEASURES: The primary efficacy end point was prevention of S. aureus bacteremia and/or deep sternal wound infection (including mediastinitis) through postoperative day 90. Secondary end points included all S. aureus surgical site and invasive infections through postoperative day 90. Three interim analyses with futility assessments were planned. RESULTS: The independent data monitoring committee recommended termination of the study after the second interim analysis because of safety concerns and low efficacy. At the end of the study, the V710 vaccine was not significantly more efficacious than placebo in preventing either the primary end points (22/3528 V710 vaccine recipients [2.6 per 100 person-years] vs 27/3517 placebo recipients [3.2 per 100 person-years]; relative risk, 0.81; 95% CI, 0.44-1.48; P = .58) or secondary end points despite eliciting robust antibody responses. Compared with placebo, the V710 vaccine was associated with more adverse experiences during the first 14 days after vaccination (1219/3958 vaccine recipients [30.8%; 95% CI, 29.4%-32.3%] and 866/3967 placebo recipients [21.8%; 95% CI, 20.6%-23.1%], including 797 [20.1%; 95% CI, 18.9%-21.4%] and 378 [9.5%; 95% CI, 8.6%-10.5%] with injection site reactions and 66 [1.7%; 95% CI, 1.3%-2.1%] and 51 [1.3%; 95% CI, 1.0%-1.7%] with serious adverse events, respectively) and a significantly higher rate of multiorgan failure during the entire study (31 vs 17 events; 0.9 [95% CI, 0.6-1.2] vs 0.5 [95% CI, 0.3-0.8] events per 100 person-years; P = .04). Although the overall incidence of vaccine-related serious adverse events (1 in each group) and the all-cause mortality rate (201/3958 vs 177/3967; 5.7 [95% CI, 4.9-6.5] vs 5.0 [95% CI, 4.3-5.7] deaths per 100 person-years; P = .20) were not statistically different between groups, the mortality rate in patients with staphylococcal infections was significantly higher among V710 vaccine than placebo recipients (15/73 vs 4/96; 23.0 [95% CI, 12.9-37.9] vs 4.2 [95% CI, 1.2-10.8] per 100 person-years; difference, 18.8 [95% CI, 8.0-34.1] per 100 person-years). CONCLUSIONS AND RELEVANCE: Among patients undergoing cardiothoracic surgery with median sternotomy, the use of a vaccine against S. aureus compared with placebo did not reduce the rate of serious postoperative S. aureus infections and was associated with increased mortality among patients who developed S. aureus infections. These findings do not support the use of the V710 vaccine for patients undergoing surgical interventions. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00518687.


Assuntos
Bacteriemia/prevenção & controle , Infecções Estafilocócicas/prevenção & controle , Vacinas Antiestafilocócicas/administração & dosagem , Vacinas Antiestafilocócicas/efeitos adversos , Esternotomia/efeitos adversos , Infecção da Ferida Cirúrgica/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/mortalidade , Procedimentos Cirúrgicos Cardiovasculares , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Infecções Estafilocócicas/mortalidade , Staphylococcus aureus , Procedimentos Cirúrgicos Torácicos/efeitos adversos , Vacinação , Adulto Jovem
12.
JTCVS Tech ; 21: 45-55, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37854813

RESUMO

Transaxillary access has been the most frequently used nonfemoral access route for transcatheter aortic valve replacement (TAVR) with a self-expanding valve. Use of transcarotid TAVR is increasing; however, comparative data on these methods are limited. We compared outcomes following transcarotid or transaxillary TAVR with a self-expanding, supra-annular valve. Methods: The Transcatheter Valve Therapy Registry was queried for TAVR procedures using transaxillary and transcarotid access between July 2015 and June 2021. Patients received a self-expanding Evolut R, PRO, or PRO + valve (Medtronic) and had 1-year follow-up. Thirty-day and 1-year outcomes were compared in transcarotid and transaxillary groups after 1:2 propensity score-matching. Multivariable regression models were fitted to identify predictors of key end points. Results: The propensity score-matched cohort included 576 patients receiving transcarotid and 1142 receiving transaxillary access. Median procedure time (99 vs 118 minutes; P < .001) and hospital stay (2 vs 3 days; P < .001) were shorter with transcarotid versus transaxillary access. At 30 days, patients with transcarotid access had similar mortality (Kaplan-Meier estimates 3.7% vs 4.3%, P = .57) but significantly lower stroke (3.1% vs 5.9%; P = .017) and mortality or stroke (6.0% vs 8.9%; P = .033) compared with patients receiving transaxillary access. Similar differences were observed at 1 year. Transaxillary access was associated with increased risk of 30-day stroke (hazard ratio, 2.14; 95% confidence interval, 1.27-3.58) by multivariable regression analysis. Conclusions: Transcarotid versus transaxillary access for TAVR using a self-expanding valve is associated with procedural benefits and significantly lower stroke and mortality or stroke at 30 days. In patients with unsuitable femoral anatomy, transcarotid access may be the preferred delivery route for self-expanding valves.

13.
JACC Cardiovasc Interv ; 16(5): 530-539, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36922038

RESUMO

BACKGROUND: Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) is increasingly used to treat degenerated surgical bioprostheses. Bioprosthetic valve fracture (BVF) has been shown to improve hemodynamic status in VIV TAVR in case series. However, the safety and efficacy of BVF are unknown. OBJECTIVES: The primary objective of this study was to assess the safety and efficacy of VIV TAVR using SAPIEN 3 and SAPIEN 3 Ultra valves with or without BVF using data from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry. METHODS: The primary outcome was in-hospital mortality. Secondary outcomes included echocardiography-derived valve gradient and aortic valve area. Inverse probability of treatment weighting was used to adjust for baseline characteristics. RESULTS: A total of 2,975 patients underwent VIV TAVR from December 15, 2020, to March 31, 2022. BVF was attempted in 619 patients (21%). In adjusted analyses, attempted BVF was associated with higher in-hospital mortality (OR: 2.51; 95% CI: 1.30-4.84) and life-threatening bleeding (OR: 2.55; 95% CI: 1.44-4.50). At discharge, VIV TAVR with attempted BVF was associated with larger aortic valve area (1.6 cm2 vs 1.4 cm2; P < 0.01) and lower mean gradient (16.3 mm Hg vs 19.2 mm Hg; P < 0.01). When BVF was compared with no BVF according to timing (before vs after transcatheter heart valve implantation), BVF after transcatheter heart valve implantation was associated with improved hemodynamic status and similar mortality. CONCLUSIONS: BVF as an adjunct to VIV TAVR with the SAPIEN 3 and SAPIEN 3 Ultra valves is associated with a higher risk for in-hospital mortality and significant bleeding and modest improvements in echocardiography-derived hemodynamic status. The timing of BVF is an important determinant of safety and efficacy.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Falha de Prótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco
14.
JTCVS Tech ; 20: 24-29, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37555046

RESUMO

Objective: HAART 300 300 (BioStable Science and Engineering, Inc) aortic annuloplasty rings restore physiologic annular geometry during aortic valve repair. Transcatheter valve-in-ring implantation is appealing for recurrent valve dysfunction but may necessitate balloon fracture of downsized annuloplasty rings. We characterized the feasibility of ring fracture and changes in ring geometry preceding fracture. Methods: The 19-mm, 21-mm, and 23-mm HAART 300 annuloplasty rings were obtained, and 23-mm, 24-mm, 25-mm, and 26-mm valvuloplasty balloons were obtained. Under continuous fluoroscopy and video recording, a 23-mm balloon was inflated within a 19-mm ring at 1 atm/s until ring fracture or balloon failure occurred. If balloon failure occurred, experiments were sequentially repeated with 1-mm upsized balloons until ring fracture occurred or no larger-sized balloons were available. Results: Upon balloon inflation, all rings exhibited an irreversible conformational change from an elliptical, annular geometry to a circular shape with ring posts flaring outward. A 23-mm balloon burst at 21 atm without fracturing the 19-mm ring. The 24-mm balloon fractured the 19-mm ring at 15 atm. Likewise, a 24-mm balloon ruptured at 18 atm without fracturing the 21-mm annuloplasty ring. A 25-mm balloon fractured the 21-mm ring at 18 atm. Finally, a 26-mm balloon burst at 20 atm without fracturing a 23-mm annuloplasty ring, but it did elicit the confirmational changes described. All fractures occurred along the upslope of a ring post. The exposed metal frame was visible after the 21-mm ring fracture. Conclusions: Fracture of HAART 300 aortic annuloplasty rings is possible with an oversized, high-pressure balloon. However, the geometrical changes in the ring and subsequent rupture of its fabric covering may be obstacles to safe, in vivo ring fracture.

15.
Struct Heart ; 7(6): 100202, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38046858

RESUMO

Background: The effectiveness of cerebral embolic protection devices (CEPD) in mitigating stroke after transcatheter aortic valve implantation (TAVI) remains uncertain, and therefore CEPD may be utilized differently across US hospitals. This study aims to characterize the hospital-level pattern of CEPD use during TAVI in the US and its association with outcomes. Methods: Patients treated with nontransapical TAVI in the 2019 Nationwide Readmissions Database were included. Hospitals were categorized as CEPD non-users and CEPD users. The following outcomes were compared: the composite of in-hospital stroke or transient ischemic attack (TIA), in-hospital ischemic stroke, death, and cost of hospitalization. Logistic regression models were used for risk adjustment of clinical outcomes. Results: Of 41,822 TAVI encounters, CEPD was used in 10.6% (n = 4422). Out of 392 hospitals, 65.8% were CEPD non-user hospitals and 34.2% were CEPD users. No difference was observed between CEPD non-users and CEPD users in the risk of in-hospital stroke or TIA (adjusted odds ratio (OR) = 0.99 [0.86-1.15]), ischemic stroke (adjusted OR = 1.00 [0.85-1.18]), or in-hospital death (adjusted OR = 0.86 [0.71-1.03]). The cost of hospitalization was lower in CEPD non-users. Conclusions: Two-thirds of hospitals in the US do not use CEPD for TAVI, and no significant difference was observed in neurologic outcomes among patients treated at CEPD non-user and CEPD user hospitals.

16.
JACC Cardiovasc Interv ; 16(3): 261-273, 2023 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-36792252

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is increasingly used to revascularize patients ineligible for CABG, but few studies describe these patients and their outcomes. OBJECTIVES: This study sought to describe characteristics, utility of risk prediction, and outcomes of patients with left main or multivessel coronary artery disease ineligible for coronary bypass grafting (CABG). METHODS: Patients with complex coronary artery disease ineligible for CABG were enrolled in a prospective registry of medical therapy + PCI. Angiograms were evaluated by an independent core laboratory. Observed-to-expected 30-day mortality ratios were calculated using The Society for Thoracic Surgeons (STS) and EuroSCORE (European System for Cardiac Operative Risk Evaluation) II scores, surgeon-estimated 30-day mortality, and the National Cardiovascular Data Registry (NCDR) CathPCI model. Health status was assessed at baseline, 1 month, and 6 months. RESULTS: A total of 726 patients were enrolled from 22 programs. The mean SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score was 32.4 ± 12.2 before and 15.0 ± 11.7 after PCI. All-cause mortality was 5.6% at 30 days and 12.3% at 6 months. Observed-to-expected mortality ratios were 1.06 (95% CI: 0.71-1.36) with The Society for Thoracic Surgeons score, 0.99 (95% CI: 0.71-1.27) with the EuroSCORE II, 0.59 (95% CI: 0.42-0.77) using cardiac surgeons' estimates, and 4.46 (95% CI: 2.35-7.99) using the NCDR CathPCI score. Health status improved significantly from baseline to 6 months: SAQ summary score (65.9 ± 22.5 vs 86.5 ± 15.1; P < 0.0001), Kansas City Cardiomyopathy Questionnaire summary score (54.1 ± 27.2 vs 82.6 ± 19.7; P < 0.0001). CONCLUSIONS: Patients ineligible for CABG who undergo PCI have complex clinical profiles and high disease burden. Following PCI, short-term mortality is considerably lower than surgeons' estimates, similar to surgical risk model predictions but is over 4-fold higher than estimated by the NCDR CathPCI model. Patients' health status improved significantly through 6 months.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Fatores de Risco
17.
JACC Cardiovasc Interv ; 16(13): 1594-1608, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37294230

RESUMO

BACKGROUND: There are limited data on the effect of bioprosthetic valve remodeling (BVR) on transcatheter heart valve (THV) expansion and function following valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) in a nonfracturable surgical heart valve (SHV). OBJECTIVES: This study sought to assess the impact of BVR of nonfracturable SHVs on THVs after VIV implantation. METHODS: VIV TAVR was performed using 23-mm SAPIEN3 (S3, Edwards Lifesciences) or 23/26-mm Evolut Pro (Medtronic) THVs implanted in 21/23-mm Trifecta (Abbott Structural Heart) and 21/23-mm Hancock (Medtronic) SHVs with BVR performed with a noncompliant TRUE balloon (Bard Peripheral Vascular Inc). Hydrodynamic assessment was performed, and multimodality imaging including micro-computed tomography was performed before and after BVR to assess THV and SHV expansion. RESULTS: BVR resulted in limited improvement of THV expansion. The largest gain in expansion was observed for the S3 in the 21-mm Trifecta with up to a 12.7% increase in expansion at the outflow of the valve. Minimal change was observed at the level of the sewing ring. The Hancock was less amenable to BVR with lower final expansion dimensions than the Trifecta. BVR also resulted in notable surgical post flaring of up to 17.6°, which was generally more marked with the S3 than with the Evolut Pro. Finally, BVR resulted in very limited improvement in hydrodynamic function. Severe pinwheeling was observed with the S3, which improved slightly but persisted despite BVR. CONCLUSIONS: When performing VIV TAVR inside a Trifecta and Hancock SHV, BVR had a limited impact on THV expansion and resulted in SHV post flaring with unknown consequences on coronary obstruction risk and long-term THV function.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hidrodinâmica , Microtomografia por Raio-X , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia
18.
EuroIntervention ; 18(14): 1165-1177, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36534495

RESUMO

BACKGROUND: Bioprosthetic valve fracture (BVF) can be used to improve transcatheter heart valve (THV) haemodynamics following a valve-in-valve (ViV) intervention. However, whether BVF should be performed before or after THV deployment and the implications on durability are unknown.  Aims: We sought to assess the impact of BVF timing on long-term THV durability. METHODS: The impact of BVF timing was assessed using small ACURATE neo (ACn) or 23 mm SAPIEN 3 (S3) THV deployed in 21 mm Mitroflow valves compared to no-BVF controls. Valves underwent accelerated wear testing up to 200 million (M) cycles (equivalent to 5 years). At 200M cycles, THV were evaluated by hydrodynamic testing, second-harmonic generation (SHG) microscopy, scanning electron microscopy (SEM) and histology. RESULTS: At 200M cycles, the regurgitant fraction (RF) and effective orifice area (EOA) for the ACn were 8.03±0.30%/1.74±0.01 cm2 (no BVF), 12.48±0.70%/1.97±0.02 cm2 (BVF before ViV) and 9.29±0.38%/2.21±0.0 cm2 (BVF after ViV), respectively. For the S3 these values were 2.63±0.51%/1.26±0.01 cm2, 2.03±0.42%/1.65±0.01 cm2, and 1.62±0.38%/2.22±0.01 cm2, respectively. Further, SHG and SEM revealed a higher degree of superficial leaflet damage when BVF was performed after ViV for the ACn and S3. However, the histological analysis revealed significantly less damage, as determined by matrix density analysis, through the entire leaflet thickness when BVF was performed after ViV with the S3 and a similar but non-significant trend with the ACn.  Conclusions: BVF performed after ViV appears to offer superior long-term EOA without increased RF. Ultrastructure leaflet analysis reveals that the timing of BVF can differentially impact leaflets, with more superficial damage but greater preservation of overall leaflet structure when BVF is performed after ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Desenho de Prótese , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
19.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988439

RESUMO

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Desenho de Prótese
20.
N Engl J Med ; 361(3): 235-44, 2009 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-19605828

RESUMO

BACKGROUND: Vein-graft harvesting with the use of endoscopy (endoscopic harvesting) is a technique that is widely used to reduce postoperative wound complications after coronary-artery bypass grafting (CABG), but the long-term effects on the rate of vein-graft failure and on clinical outcomes are unknown. METHODS: We studied the outcomes in patients who underwent endoscopic harvesting (1753 patients) as compared with those who underwent graft harvesting under direct vision, termed open harvesting (1247 patients), in a secondary analysis of 3000 patients undergoing CABG. The method of graft harvesting was determined by the surgeon. Vein-graft failure was defined as stenosis of at least 75% of the diameter of the graft on angiography 12 to 18 months after surgery (data were available in an angiographic subgroup of 1817 patients and 4290 grafts). Clinical outcomes included death, myocardial infarction, and repeat revascularization. Generalized estimating equations were used to adjust for baseline covariates associated with vein-graft failure and to account for the potential correlation between grafts within a patient. Cox proportional-hazards modeling was used to assess long-term clinical outcomes. RESULTS: The baseline characteristics were similar between patients who underwent endoscopic harvesting and those who underwent open harvesting. Patients who underwent endoscopic harvesting had higher rates of vein-graft failure at 12 to 18 months than patients who underwent open harvesting (46.7% vs. 38.0%, P<0.001). At 3 years, endoscopic harvesting was also associated with higher rates of death, myocardial infarction, or repeat revascularization (20.2% vs. 17.4%; adjusted hazard ratio, 1.22; 95% confidence interval [CI], 1.01 to 1.47; P=0.04), death or myocardial infarction (9.3% vs. 7.6%; adjusted hazard ratio, 1.38; 95% CI, 1.07 to 1.77; P=0.01), and death (7.4% vs. 5.8%; adjusted hazard ratio, 1.52; 95% CI, 1.13 to 2.04; P=0.005). CONCLUSIONS: Endoscopic vein-graft harvesting is independently associated with vein-graft failure and adverse clinical outcomes. Randomized clinical trials are needed to further evaluate the safety and effectiveness of this harvesting technique.


Assuntos
Ponte de Artéria Coronária/métodos , Endoscopia , Veia Safena/transplante , Idoso , Angiografia Coronária , Doença das Coronárias/mortalidade , Doença das Coronárias/cirurgia , Método Duplo-Cego , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Modelos de Riscos Proporcionais , Reoperação , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA