Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Fetal Diagn Ther ; 50(4): 225-235, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36948159

RESUMO

INTRODUCTION: Both tissue Doppler imaging (TDI) and pulsed wave Doppler (PWD) Myocardial Performance Indices (MPIs) have been proposed as tools for functional fetal cardiology. We wished to determine if there was any correlation between TDI-MPI and PWD-MPI. METHODS: A cohort of uncomplicated women with morphologically normal singleton fetuses between 22 and 39 weeks of gestation was recruited. A single sonologist acquired Doppler waveforms for evaluation of both left and right TDI-MPI and PWD-MPI. The PWD-MPI values were calculated using a previously published algorithm and the TDI-MPI time intervals were measured manually by a single operator. RESULTS: Achievability and repeatability were high for both modalities. TDI produced significantly lower right MPI values yet significantly higher left MPI values, potentially reflecting their evaluation of physiologically different events, blood flow versus myocardial contraction. CONCLUSION: This study demonstrates that MPIs measured from PWD and TDI have a weak correlation and cannot be used interchangeably, even with the exclusion of suboptimal TDI-MPI scans from the analysis. Given the lack of correlation between the two methods, the high variation in TDI waveform, and the lack of unified approach to TDI analysis, we feel further research is needed before adoption of this technique.


Assuntos
Ecocardiografia Doppler de Pulso , Função Ventricular Esquerda , Humanos , Feminino , Gravidez , Ecocardiografia Doppler de Pulso/métodos , Função Ventricular Esquerda/fisiologia , Contração Miocárdica/fisiologia , Ecocardiografia Doppler/métodos , Feto
2.
Fetal Diagn Ther ; 48(9): 651-659, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34710879

RESUMO

INTRODUCTION: Maternal hyperoxygenation effects on fetal cerebral hemodynamics are largely unknown. This study aimed to determine efficacy and reliability of a validated power Doppler ultrasound (US) index, fractional moving blood volume (FMBV), at measuring fetal cerebral vasculature changes during maternal hyperoxia. METHODS: The fetal cerebral effects of 10 min of hyperoxygenation at 2 flow rates (52%/60% FiO2) were evaluated in women in their third trimester of pregnancy. 2D-US and 3D-US in a transverse plane were performed before, during, and following maternal hyperoxygenation with FMBV estimation performed offline. RESULTS: Forty-five cases provided data for analysis. Mean intraobserver ICCs were 0.89 (3D-FMBV) and 0.84 (2D-FMBV). A significant difference in vascularity before and during and before and after 60% hyperoxia was observed (p < 0.05), whereas no significant differences were found at 52% hyperoxia (p > 0.05). Significant differences in vascularity were found between 2D-FMBV and 3D-FMBV (p < 0.01). CONCLUSION: Measurement of fetal cerebral vascularity by 3D-FMBV and 2D-FMBV was highly reproducible. The differing cerebral vascular changes seen with 60% but not 52% FiO2 suggest a possible "threshold effect" that may have influenced prior studies. Further studies are needed to assess cerebral effects of maternal hyperoxygenation on compromised fetuses.


Assuntos
Volume Sanguíneo , Ultrassonografia Doppler , Encéfalo/diagnóstico por imagem , Feminino , Humanos , Gravidez , Terceiro Trimestre da Gravidez , Reprodutibilidade dos Testes , Ultrassonografia Pré-Natal
3.
Fetal Diagn Ther ; 43(3): 208-217, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28614833

RESUMO

OBJECTIVES: To determine whether there are any fetal cardiac function changes, as measured by the myocardial performance index (MPI), in pregnancies complicated by decreased fetal movement (DFM). METHODS: We performed a prospective cross-sectional case-control study of 50 DFM and 50 uncomplicated third-trimester pregnancies matched within 2 gestational weeks. Routine ultrasound growth and well-being parameters as well as MPI were measured. Average MPI measurements and its component values were compared between the DFM and the control group, as were demographics, other ultrasound data, and perinatal outcomes. RESULTS: Average left MPI (LMPI) and right MPI (RMPI) was similar between groups (LMPI: 0.54 ± 0.08 [DFM], 0.53 ± 0.08 [controls], p = 0.76; RMPI: 0.60 ± 0.12 (DFM), 0.59 ± 0.11 [controls], p = 0.79). However, subgroup analysis of DFM fetuses with (n = 20) or without (n = 30) any adverse perinatal outcome demonstrated modestly higher average RMPI and LMPI in the adverse perinatal outcome group (RMPI: 0.64 ± 0.08 vs. 0.57 ± 0.13, p = 0.02; LMPI: 0.56 ± 0.07 vs. 0.52 ± 0.07, p = 0.052). CONCLUSION: The MPI did not demonstrate clinically usable differences between the overall DFM population and controls. However, higher LMPI and RMPI values in the exploratory subgroup of DFM fetuses with adverse perinatal outcomes may warrant further exploration of the MPI in DFM.


Assuntos
Coração Fetal/diagnóstico por imagem , Testes de Função Cardíaca , Adulto , Estudos de Casos e Controles , Feminino , Movimento Fetal , Humanos , Gravidez , Ultrassonografia Pré-Natal
4.
Fetal Diagn Ther ; 40(2): 81-93, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27379710

RESUMO

The aortic isthmus (AoI) is a unique fetal watershed with a waveform reflecting its complex haemodynamic physiology. The systolic component represents left and right ventricular systolic ejection, and the diastolic component represents comparative downstream vascular impedance between the brachiocephalic and subdiaphragmatic fetal circulations. Several indices have been devised to quantify different components of the waveform, including the pulsatility index, resistance index, isthmic flow index, and recently the isthmic systolic index. There have been promising preliminary studies applying these indices to both cardiac (congenital) and extracardiac pathologies, including intrauterine growth restriction and twin-twin transfusion syndrome. However, the waveform's multifactorial origin has proven to be challenging, and the difficulty in separating various components of the waveform could explain that AoI evaluation does not have a clear clinical utility. Further research is underway to realise the full potential of this vessel in fetal cardiac and haemodynamically compromised pathological conditions. In this review article we outline the physiological origin of this Doppler waveform, describe in detail the various published indices, summarise the published literature to date, and finally outline potential future research and hopefully clinical applications.


Assuntos
Aorta/embriologia , Coração Fetal/fisiologia , Hemodinâmica , Aorta/fisiologia , Circulação Sanguínea , Complicações do Diabetes , Feminino , Coração Fetal/fisiopatologia , Transfusão Feto-Fetal/fisiopatologia , Feto/anatomia & histologia , Feto/fisiologia , Idade Gestacional , Humanos , Gravidez , Fluxo Sanguíneo Regional
5.
Fetal Diagn Ther ; 38(4): 288-95, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25925661

RESUMO

INTRODUCTION: Fetal cardiac dysfunction may manifest itself unilaterally as right and left ventricles differing in design, function and load, measurable as differing in myocardial performance indices (MPIs). We wished to define this difference ('delta-MPI' or DMPI), present its normal range and pilot its use in pathological pregnancy. MATERIAL AND METHODS: Prospective cross-sectional study of 324 normal singleton fetuses (16-38 weeks of gestation). Left and right modified MPI (LMPI and RMPI) were performed during a single examination using the 'peak' valve click technique. Thirty-seven pathological singleton and monochorionic diamniotic twin pregnancies were compared as pilot data. RESULTS: Modified MPIs (mean ± SD) were 0.45 ± 0.06 (LMPI) and 0.47 ± 0.09 (RMPI), being similar at 18 weeks' gestation with DMPI increasing slightly throughout pregnancy (0.02 ± 0.08). Both singleton intrauterine growth restriction (IUGR) and recipient twin-twin transfusion syndrome (TTTS) showed significantly elevated RMPI, LMPI and DMPI, most pronounced for DMPI (450 and 500% increase, respectively; p < 0.01). DMPI acquisition rates were 83.3% normal and 87.0% pathological. DISCUSSION: We demonstrate for the first time differing intrafetal LMPI and RMPI in a large gestational cohort, with this difference increasing with gestational age. Pilot data confirm the potential for DMPI as a tool to assess unilateral myocardial function in singleton IUGR and recipient twins in TTTS, and further studies are under way to evaluate its clinical utility.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Doenças Fetais/diagnóstico por imagem , Coração Fetal/fisiologia , Ultrassonografia Pré-Natal/métodos , Cardiomiopatias/embriologia , Estudos de Coortes , Estudos Transversais , Feminino , Coração Fetal/fisiopatologia , Idade Gestacional , Humanos , Gravidez , Valores de Referência
6.
Fetal Diagn Ther ; 36(3): 183-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25096159

RESUMO

OBJECTIVE: To assess 2D and 3D frontomaxillary facial angle (FMFA) measurements in euploid and trisomy 21 fetuses. MATERIALS AND METHODS: Over a 2-year period, women with singleton pregnancies attending a private prenatal screening and diagnosis practice in Sydney, Australia, were invited to participate in this study where 2D images and 3D volumes of the fetal face were collected during routine first trimester screening. In pregnancies where trisomy 21 was confirmed, FMFA measurements were performed in 2D and 3D and compared with those from a euploid cohort. RESULTS: Overall, 250 women carrying euploid and 22 women carrying trisomy 21 fetuses participated. Trisomy 21 fetuses had significantly larger FMFA measurements than euploid fetuses in both 2D and 3D assessments. 95% of 3D and 100% of 2D FMFA measurements for the trisomy 21 fetuses were above the mean FMFA measurement of the euploid fetuses. There was no relationship between increasing crown-rump length and FMFA measurement. CONCLUSION: 2D and 3D FMFA measurements in trisomy 21 fetuses are statistically greater (p < 0.001) than those in euploid fetuses. This supports FMFA as a possible additional marker for trisomy 21 for first trimester screening.


Assuntos
Síndrome de Down/diagnóstico por imagem , Face/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Feminino , Humanos , Imageamento Tridimensional , Gravidez , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Adulto Jovem
7.
Fetal Diagn Ther ; 34(2): 90-5, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23751732

RESUMO

INTRODUCTION: The primary aim of this study was to assess the interobserver and intraobserver reproducibility of the first-trimester frontomaxillary facial angle (FMFA) measurement using both 2D and 3D ultrasound. Assessment of the relationship between crown-to-rump length (CRL) and FMFA measurement was also reviewed. MATERIALS AND METHODS: Two experienced operators imaged the same 30 patients over a 1-month period collecting both 2D static images and 3D volumes during nuchal translucency assessment at 11-14 weeks' gestation. The operators were blinded to each other's images and results. RESULTS: The mean 2D FMFA measurement was 88.0° and 88.4° for observer 1 and 2, respectively; while the mean 3D FMFA measurement was 87.8° and 88.0°, respectively. Intraclass correlation suggests good intraobserver and interobserver agreement with no statistically significant difference between operators in either 2D (p = 0.14) or 3D (p = 0.11) measurements. The FMFA was unchanged with increasing CRL. DISCUSSION: Both 2D and 3D FMFA measurements have been demonstrated to be equivalent and reliable. Strict image acquisition criteria must be followed for accurate and reproducible FMFA measurements. There was no change demonstrated in FMFA measurement with increasing CRL.


Assuntos
Síndrome de Down/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Aneuploidia , Estudos de Coortes , Estatura Cabeça-Cóccix , Feminino , Humanos , Imageamento Tridimensional/métodos , Medição da Translucência Nucal , Variações Dependentes do Observador , Gravidez , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Fetal Diagn Ther ; 28(1): 14-21, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20587987

RESUMO

INTRODUCTION: The aim of this study is to (i) directly compare both two-dimensional (2D) and three-dimensional (3D) frontomaxillary facial angle (FMFA) in first trimester, and (ii) to assess the ease with which both may be performed. MATERIALS AND METHODS: Both 3D volumes of the fetal head and 2D fetal profiles were collected from 251 consenting patients during routine first-trimester nuchal translucency (NT) screening. The FMFA in 2D was measured at the time of the NT screening. The 3D FMFA was measured offline. RESULTS: The 2D FMFA was systematically higher than the 3D FMFA. The difference in 3D-2D FMFA was statistically significant from 11+0 to 12+3 weeks. From 12+4 to 13+6 weeks the difference was no longer significant with p = 0.06. Performing the measurement did not unduly increase the time of the study. Even for the experienced sonographer the technique is technically difficult, relying on many factors for accurate caliper placement. DISCUSSION: The 2D FMFA is greater than the 3D angle. This was found in previous studies, but not thought to be statistically significant. The difference decreased with increasing gestational age. There is a learning curve associated with performing this measurement. Normative data for both 2D and 3D, incorporating ethnicity, may be necessary before inclusion in the first-trimester algorithm.


Assuntos
Síndrome de Down/diagnóstico por imagem , Face/diagnóstico por imagem , Imageamento Tridimensional , Ultrassonografia Pré-Natal , Fatores Etários , Face/embriologia , Feminino , Desenvolvimento Fetal , Idade Gestacional , Cabeça/diagnóstico por imagem , Cabeça/embriologia , Humanos , Gravidez , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade
9.
Placenta ; 94: 13-19, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32217266

RESUMO

BACKGROUND: Placental perfusion can be evaluated by 3D power Doppler ultrasound (3D PD-US), particularly using the validated tool 3D Fractional Moving Blood Volume (3D-FMBV); however regional variability and size limitations beyond the first trimester mean that multiple 3D PD-US volumes are required to evaluate the whole organ. PURPOSE: We assessed the feasibility of manual offline stitching of second trimester 3D PD-US volumes of the placenta to assess whole organ perfusion using 3D-FMBV. MATERIALS AND METHODS: This was a single-centre, prospective, observational cohort study of 36 normal second trimester singleton pregnancies with anterior placentas. 3D PD-US placental volumes were manually segmented offline and stitched together by rigid registration using manually selected, pair-wise coordinates. Data acquisition and offline volume segmentation and stitching were triplicated by a single observer with Dice similarity coefficient (DSC) and Hausdorff distance used to assess consistency. Intraclass correlation coefficient (ICC) was used to assess intra-observer repeatability of 3D-FMBV and placental volume. RESULTS: Acquisition and stitching success were 94% and 88%, respectively. Median time for acquisition, segmentation and stitching were 13 min, 40 min and 95 min, respectively. Median intra-observer DSCs were 0.94 and 0.88, and Hausdorff distances were 11.85 mm and 36.6 mm, for segmentations and stitching, respectively. CONCLUSION: 3D-ultrasound volume stitching of the placenta is technically feasible. Intra-observer repeatability was good to excellent for all measured parameters. This work demonstrates technical feasibility; further studies may provide the basis of an in-vivo assessment tool to measure the placenta in mid-to late pregnancy.


Assuntos
Imageamento Tridimensional/métodos , Placenta/irrigação sanguínea , Ultrassonografia Doppler/métodos , Ultrassonografia Pré-Natal/métodos , Adulto , Volume Sanguíneo , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Variações Dependentes do Observador , Gravidez , Segundo Trimestre da Gravidez , Estudos Prospectivos
10.
J Matern Fetal Neonatal Med ; 32(12): 2017-2029, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29301441

RESUMO

AIMS: Assess clinical utility of the foetal Myocardial Performance Index (MPI) in evaluation and management of monochorionic, diamniotic twin (MCDA) pregnancies. METHODS: Prospective cohort of (a) initially uncomplicated MCDA (b) Complicated MCDA, including twin-twin transfusion syndrome (TTTS), selective intrauterine growth restriction (sIUGR), and liquor and/or growth discordance (L/GD) not meeting TTTS or sIUGR criteria. TTTS and sIUGR were case-control matched. Routine Dopplers and MPI were taken and correlated to diagnosis and final outcome. RESULTS: Twenty-six always uncomplicated pairs, 51 always complicated pairs, and seven uncomplicated to pathological pairs were included. TTTS recipient (n = 25) left and right MPI and intertwin difference (ITD) were significantly elevated, however, were already elevated in Stage I (n = 10), and did not predict progression or pregnancy outcome. sIUGR MPI (n = 11) did not differ significantly from control. Of 15-L/GD pairs, two that progressed to TTTS had significantly higher left and right MPI values in the future recipient (0.61 and 0.72) versus future sIUGR larger twins (0.48 and 0.51) or stable L/GD (0.47 and 0.52): p < .01 for all comparisons. CONCLUSIONS: In this cohort, MPI did not add substantial diagnostic/prognostic information to current routine evaluation in established TTTS or sIUGR though potentially differentiated L/GD cases progressing to TTTS.


Assuntos
Coração Fetal/diagnóstico por imagem , Gravidez de Gêmeos , Gêmeos Monozigóticos , Ultrassonografia Pré-Natal/métodos , Estudos de Casos e Controles , Feminino , Retardo do Crescimento Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/diagnóstico por imagem , Humanos , Gravidez , Estudos Prospectivos
11.
Neonatology ; 116(2): 115-122, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31137032

RESUMO

BACKGROUND: There is currently no reliable non-invasive method of measuring cardiac output in neonatal intensive care. Spatiotemporal image correlation (STIC) is a novel four-dimensional (4D) ultrasound technique that was developed to assess the foetal heart, and it may be a useful way to assess neonatal haemodynamics. OBJECTIVE: This study aimed to evaluate the feasibility and reproducibility of determining neonatal cardiac output using STIC ultrasound in newborn infants. DESIGN: Infants were recruited opportunistically from a neonatal intensive care unit and then examined by 2 independent observers. STIC was used to obtain images of the heart. End-diastolic and end-systolic ventricular volumes were measured using virtual organ computer-aided analysis (VOCAL) and used to calculate cardiac output. Reproducibility was assessed with intraclass correlation coefficients (ICC) and agreement with Bland-Altman analysis. RESULTS: Twenty-four clinically stable infants of 34-43 weeks corrected gestational age were assessed. Both observers successfully acquired 4D STIC volumes in all infants. Left ventricular output showed good reproducibility, with an intra-observer ICC of 0.86 (0.69-0.94) and inter-observer ICC of 0.87 (0.70-0.95). Right ventricular output also showed good reproducibility, with an intra-observer ICC of 0.88 (0.70-95) and inter-observer ICC of 0.84 (0.63-0.93). CONCLUSIONS: Determining cardiac output using 4D STIC ultrasound is feasible and reproducible in well newborn infants. With further evaluation, this technique may provide valuable information about haemodynamic status in newborn infants requiring intensive care.


Assuntos
Débito Cardíaco , Ecocardiografia Quadridimensional/métodos , Ventrículos do Coração/diagnóstico por imagem , Triagem Neonatal/métodos , Estudos de Viabilidade , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Projetos Piloto , Reprodutibilidade dos Testes , Volume Sistólico
12.
Australas J Ultrasound Med ; 21(3): 169-178, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34760518

RESUMO

INTRODUCTION: Spatiotemporal image correlation (STIC) can evaluate fetal renal impedance using four-dimensional volumetric indices. We assessed repeatability of three-dimensional kidney segmentation and the repeatability of the resultant indices. METHODS: In each of 57 healthy pregnant women, three renal artery pulsed-wave Doppler (PWD) traces and three STIC volumes were acquired from the same fetal kidney and segmented by two observers. Vascularisation-flow index (VFI) and fractional moving blood volume (FMBV) were calculated for every STIC frame and used to determine the volumetric pulsatility index (vPI), volumetric resistance index (vRI) and volumetric systolic/diastolic ratio (vS/D). Segmentation performance was assessed using Dice similarity coefficients (DSCs), Hausdorff distances, coefficient of variation (CoV) and the intraclass correlation coefficient (ICC). Intra/Inter volumetric index repeatability was assessed using ICCs. RESULTS: Forty-eight cases (84%) provided full data. Mean intra- and interobserver DSCs were 0.90 and 0.81. Mean intra- and interobserver Hausdorff distances were 3.88 mm and 5.27 mm. Average kidney volumes for observers 1 and 2 were 9.88 mL and 8.54 mL (mean difference 16.1%). Mean intra-observer volumetric CoVs were 5.3% and 8.1%. Intra- and interobserver ICCs for kidney volume (same STIC volume) were 0.97 and 0.85. When assessing volume variation between STIC volumes, intra-observer ICC was 0.97. ICCs were 0.77-0.81 for VFI-derived volumetric indices and 0.61-0.62 for FMBV-derived indices; ICCs for all PWD indices were between 0.58 and 0.59. CONCLUSIONS: Periodical variation in vascularity was demonstrated in the fetal kidney, and three-dimensional segmentation was highly repeatable. Derived volumetric impedance indices show moderate variability but outperform corresponding two-dimensional PWD indices in terms of reproducibility.

13.
Obstet Gynecol Int ; 2013: 847293, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24288543

RESUMO

Objectives. To determine the existence and extent of ethnic differences in 2D or 3D fetal frontomaxillary facial angle (FMFA) measurements. Methods. During routine 11-14 weeks nuchal translucency screening undertaken in a private ultrasound practice in Sydney, Australia, 2D images and 3D volumes of the fetal profile were collected from consenting patients. FMFA was measured on a frozen 2D ultrasound image in the appropriate plane and, after a delay of at least 48 hours, was also measured on the reconstructed 3D ultrasound volume offline. Results. Overall 416 patients were included in the study; 220 Caucasian, 108 north Asian, 36 east Asian and 52 south Asian patients. Caucasians had significantly lower median FMFA measurements than Asians in both 2D (2.2°; P < 0.001) and 3D (3.4°; P < 0.001) images. Median 2D measurements were significantly higher than 3D measurements in the Caucasian and south Asian groups (P < 0.001 and P = 0.04), but not in north and east Asian groups (P = 0.08 and P = 0.41). Conclusions. Significant ethnic variations in both 2D and 3D FMFA measurements exist. These differences may indicate the need to establish ethnic-specific reference ranges for both 2D and 3D imaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA