Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(8): 5228-5238, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38244046

RESUMO

OBJECTIVE: To determine the inter-reader reliability and diagnostic performance of classification and severity scales of Neuropathy Score Reporting And Data System (NS-RADS) among readers of differing experience levels after limited teaching of the scoring system. METHODS: This is a multi-institutional, cross-sectional, retrospective study of MRI cases of proven peripheral neuropathy (PN) conditions. Thirty-two radiology readers with varying experience levels were recruited from different institutions. Each reader attended and received a structured presentation that described the NS-RADS classification system containing examples and reviewed published articles on this subject. The readers were then asked to perform NS-RADS scoring with recording of category, subcategory, and most likely diagnosis. Inter-reader agreements were evaluated by Conger's kappa and diagnostic accuracy was calculated for each reader as percent correct diagnosis. A linear mixed model was used to estimate and compare accuracy between trainees and attendings. RESULTS: Across all readers, agreement was good for NS-RADS category and moderate for subcategory. Inter-reader agreement of trainees was comparable to attendings (0.65 vs 0.65). Reader accuracy for attendings was 75% (95% CI 73%, 77%), slightly higher than for trainees (71% (69%, 72%), p = 0.0006) for nerves and comparable for muscles (attendings, 87.5% (95% CI 86.1-88.8%) and trainees, 86.6% (95% CI 85.2-87.9%), p = 0.4). NS-RADS accuracy was also higher than average accuracy for the most plausible diagnosis for attending radiologists at 67% (95% CI 63%, 71%) and for trainees at 65% (95% CI 60%, 69%) (p = 0.036). CONCLUSION: Non-expert radiologists interpreted PN conditions with good accuracy and moderate-to-good inter-reader reliability using the NS-RADS scoring system. CLINICAL RELEVANCE STATEMENT: The Neuropathy Score Reporting And Data System (NS-RADS) is an accurate and reliable MRI-based image scoring system for practical use for the diagnosis and grading of severity of peripheral neuromuscular disorders by both experienced and general radiologists. KEY POINTS: • The Neuropathy Score Reporting And Data System (NS-RADS) can be used effectively by non-expert radiologists to categorize peripheral neuropathy. • Across 32 different experience-level readers, the agreement was good for NS-RADS category and moderate for NS-RADS subcategory. • NS-RADS accuracy was higher than the average accuracy for the most plausible diagnosis for both attending radiologists and trainees (at 75%, 71% and 65%, 65%, respectively).


Assuntos
Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Doenças do Sistema Nervoso Periférico , Humanos , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Transversais , Estudos Retrospectivos , Reprodutibilidade dos Testes , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Índice de Gravidade de Doença , Radiologistas , Competência Clínica , Radiologia/educação
2.
AJR Am J Roentgenol ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38775432

RESUMO

Peripheral nerve imaging provides information that can be critical to the diagnosis, staging, and management of peripheral neuropathies. MRI and ultrasound are the imaging modalities of choice for clinical evaluation of the peripheral nerves given their high soft tissue contrast and high resolution, respectively. This AJR Expert Panel Narrative Review describes MRI- and ultrasound-based techniques for peripheral nerve imaging; highlights considerations for imaging in the settings of trauma, entrapment syndromes, diffuse inflammatory neuropathies, and tumor; and discusses image-guided nerve interventions, focusing on nerve blocks and ablation.

3.
Ann Neurol ; 92(2): 184-194, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35599442

RESUMO

OBJECTIVE: To examine rates of intravenous thrombolysis (IVT), mechanical thrombectomy (MT), door-to-needle (DTN) time, door-to-puncture (DTP) time, and functional outcome between patients with admission magnetic resonance imaging (MRI) versus computed tomography (CT). METHODS: An observational cohort study of consecutive patients using a target trial design within the nationwide Swiss-Stroke-Registry from January 2014 to August 2020 was carried out. Exclusion criteria included MRI contraindications, transferred patients, and unstable or frail patients. Multilevel mixed-effects logistic regression with multiple imputation was used to calculate adjusted odds ratios with 95% confidence intervals for IVT, MT, DTN, DTP, and good functional outcome (mRS 0-2) at 90 days. RESULTS: Of the 11,049 patients included (mean [SD] age, 71 [15] years; 4,811 [44%] women; 69% ischemic stroke, 16% transient ischemic attack, 8% stroke mimics, 6% intracranial hemorrhage), 3,741 (34%) received MRI and 7,308 (66%) CT. Patients undergoing MRI had lower National Institutes of Health Stroke Scale (median [interquartile range] 2 [0-6] vs 4 [1-11]), and presented later after symptom onset (150 vs 123 min, p < 0.001). Admission MRI was associated with: lower adjusted odds of IVT (aOR 0.83, 0.73-0.96), but not with MT (aOR 1.11, 0.93-1.34); longer adjusted DTN (+22 min [13-30]), but not with longer DTP times; and higher adjusted odds of favorable outcome (aOR 1.54, 1.30-1.81). INTERPRETATION: We found an association of MRI with lower rates of IVT and a significant delay in DTN, but not in DTP and rates of MT. Given the delays in workflow metrics, prospective trials are required to show that tissue-based benefits of baseline MRI compensate for the temporal benefits of CT. ANN NEUROL 2022;92:184-194.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Idoso , Isquemia Encefálica/complicações , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Feminino , Fibrinolíticos/uso terapêutico , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Terapia Trombolítica/métodos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Fluxo de Trabalho
4.
Ther Umsch ; 80(4): 204-208, 2023.
Artigo em Alemão | MEDLINE | ID: mdl-37122179

RESUMO

An MRI for Every Patient with Back Pain? Abstract. Imaging in spinal disorders has changed in the past years. Improved MRI techniques allow for better image interpretation. Unchanged, however, close correlation between clinical evaluation and imaging results remains crucial for correct diagnoses and subsequent therapeutical decisions. Reimbursement cuts have made MRI more affordable in Switzerland while being widely available. This allows - if used according to guidelines - for optimal treatment of patients with spinal disorders.


Assuntos
Dor nas Costas , Imageamento por Ressonância Magnética , Humanos , Dor nas Costas/diagnóstico por imagem , Suíça
5.
AJR Am J Roentgenol ; 219(2): 279-291, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35234483

RESUMO

BACKGROUND. A standardized guideline and scoring system would improve evaluation and reporting of peripheral neuropathy (PN) on MRI. OBJECTIVE. The objective of this study was to create and validate a neuropathy classification and grading system, which we named the Neuropathy Score Reporting and Data System (NS-RADS). METHODS. This retrospective study included 100 patients with nerve imaging studies and known clinical diagnoses. Experts crafted NS-RADS using mutually agreed-on qualitative criteria for the classification and grading of PN. Different classes were created to account for the spectrum of underlying pathologies: unremarkable (U), injury (I), neoplasia (N), entrapment (E), diffuse neuropathy (D), not otherwise specified (NOS), and postintervention state (PI). Subclasses were established to describe the severity or extent of the lesions. Validation testing was performed by 11 readers from 10 institutions with experience levels ranging from 3 to 18 years after residency. After initial reader training, cases were presented to readers who were blinded to the final clinical diagnoses. Interobserver agreement was assessed using correlation coefficients and the Conger kappa, and accuracy testing was performed. RESULTS. Final clinical diagnoses included normal (n = 5), nerve injury (n = 25), entrapment (n = 15), neoplasia (n = 33), diffuse neuropathy (n = 18), and persistent neuropathy after intervention (n = 4). The miscategorization rate for NS-RADS classes was 1.8%. Final diagnoses were correctly identified by readers in 71-88% of cases. Excellent inter-reader agreement was found on the NS-RADS pathology categorization (κ = 0.96; 95% CI, 0.93-0.98) as well as muscle pathology categorization (κ = 0.76; 95% CI, 0.68-0.82). The accuracy for determining milder versus more severe categories per radiologist ranged from 88% to 97% for nerve lesions and from 86% to 94% for muscle abnormalities. CONCLUSION. The proposed NS-RADS classification is accurate and reliable across different reader experience levels and a spectrum of PN conditions. CLINICAL IMPACT. NS-RADS can be used as a standardized guideline for reporting PN and improved multidisciplinary communications.


Assuntos
Imageamento por Ressonância Magnética , Doenças do Sistema Nervoso Periférico , Humanos , Imageamento por Ressonância Magnética/métodos , Variações Dependentes do Observador , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Estudos Retrospectivos
6.
Skeletal Radiol ; 51(10): 1909-1922, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35478047

RESUMO

A standardized guideline and scoring system should be used for the MR imaging diagnosis of peripheral neuropathy. The MR imaging-based Neuropathy Score Reporting and Data System (NS-RADS) is a newly devised classification system (in press in AJR) that can be used to communicate both type and severity of peripheral neuropathy in the light of clinical history and examination findings. The spectrum of neuropathic conditions and peripheral nerve disorders covered in this system includes nerve injury, entrapment, neoplasm, diffuse neuropathy, and post-interventional states. This classification system also describes the temporal MR imaging appearances of regional muscle denervation changes. This review article is based on the multicenter validation study pre-published in American journal of Roentgenology and discusses technical considerations of optimal MR imaging for peripheral nerve evaluation and discusses the NS-RADS classification and its severity scales with illustration of conditions that fall under each classification. The readers can gain knowledge of the NS-RADS classification system and learn to apply it in their practices for improved inter-disciplinary communications and timely patient management.


Assuntos
Imageamento por Ressonância Magnética , Doenças do Sistema Nervoso Periférico , Humanos , Imageamento por Ressonância Magnética/métodos , Estudos Multicêntricos como Assunto , Nervos Periféricos , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem
7.
Eur Radiol ; 28(2): 698-707, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28710579

RESUMO

Magnetic resonance neurography (also called MRN or MR neurography) refers to MR imaging dedicated to the peripheral nerves. It is a technique that enhances selective multiplanar visualisation of the peripheral nerve and pathology by encompassing a combination of two-dimensional, three-dimensional and diffusion imaging pulse sequences. Referring physicians who seek imaging techniques that can depict and diagnose peripheral nerve pathologies superior to conventional MR imaging are driving the demand for MRN. This article reviews the pathophysiology of peripheral nerves in common practice scenarios, technical considerations of MRN, current indications of MRN, normal and abnormal neuromuscular appearances, and imaging pitfalls. Finally, the emerging utility of diffusion-weighted and diffusion tensor imaging is discussed and future directions are highlighted. KEY POINTS: • Lesion relationship to neural architecture is more conspicuous on MRN than MRI. • 3D multiplanar imaging technique is essential for pre-surgical planning. • Nerve injuries can be classified on MRN using Sunderland's classification. • DTI provides quantitative information and insight into intraneural integrity and pathophysiology.


Assuntos
Imagem de Tensor de Difusão/métodos , Imageamento Tridimensional , Nervos Periféricos/patologia , Doenças do Sistema Nervoso Periférico/diagnóstico , Humanos
8.
Semin Musculoskelet Radiol ; 22(3): 334-343, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29791961

RESUMO

This article provides a review of magnetic resonance neurography (MRN) and how to get started. It explains step by step how to establish MRN at an institution: how to set up MRN protocols, how to train technicians, what a report needs to contain, and how relevant findings should be communicated to the referring physician. Advanced imaging techniques such as diffusion tensor imaging are only briefly discussed at the end of the article because most of those techniques are difficult for beginners and are still not considered standard in the clinical routine.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Serviço Hospitalar de Radiologia/organização & administração , Radiologia/educação , Protocolos Clínicos , Humanos
9.
Skeletal Radiol ; 47(9): 1269-1275, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29651713

RESUMO

OBJECTIVE: To investigate whether upright radiographs can predict lumbar spinal canal stenosis using supine lumbar magnetic resonance imaging (MRI) and to investigate the detection performance for spondylolisthesis on upright radiographs compared with supine MRI in patients with suspected lumbar spinal canal stenosis (LSS). MATERIALS AND METHODS: In this retrospective study, conventional radiographs and MR images of 143 consecutive patients with suspected LSS (75 female, mean age 72 years) were evaluated. The presence and extent of listhesis (median ± interquartile range) were assessed on upright radiographs and supine MRI of L4/5. In addition, the grade of central spinal stenosis of the same level was evaluated on MRI according to the classification of Schizas and correlated with the severity/grading of anterolisthesis on radiographs. RESULTS: Anterolisthesis was detected in significantly more patients on radiographs (n = 54; 38%) compared with MRI (n = 28; 20%), p < 0.001. Pairwise comparison demonstrated a significantly larger extent of anterolisthesis on radiographs (9 ± 5 mm) compared with MRI (5 ± 3 mm), p < 0.001. A positive correlation was found regarding the extent of anterolisthesis measured on radiographs and the grade of stenosis on MRI (r = 0.563, p < 0.001). Applying a cutoff value of ≥5 mm anterolisthesis on radiographs results in a specificity of 90% and a positive predictive value of 78% for the detection of patients with LSS, as defined by the Schizas classification. CONCLUSION: Upright radiographs demonstrated more and larger extents of anterolisthesis compared with supine MRI. In addition, in patients with suspected LSS, the extent of anterolisthesis on radiographs (particularly ≥5 mm) is indicative of LSS and warrants lumbar spine MRI.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Posicionamento do Paciente/métodos , Radiografia/métodos , Estenose Espinal/diagnóstico por imagem , Espondilolistese/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Canal Medular/diagnóstico por imagem , Posição Ortostática , Decúbito Dorsal , Suíça
10.
Neuroimage ; 152: 340-347, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28263927

RESUMO

The intra-voxel incoherent motion (IVIM) model assumes that blood flowing in isotropically distributed capillary segments induces a phase dispersion of the MR signal, which increases the signal attenuation in diffusion-weighted images. However, in most tissue types the capillary network has an anisotropic micro-architecture. In this study, we investigated the possibility to indirectly infer the anisotropy of the capillary network in the healthy cerebral gray matter by evaluating the dependence of the IVIM signal from the direction of the diffusion-encoding. Perfusion-related indices and self-diffusion were modelled as symmetric rank 2 tensors. The geometry of the tensors was quantified pixel-wise by decomposing the tensor in sphere-like, plane-like, and line-like components. Additionally, trace and fractional anisotropy of the tensors were computed. While the self-diffusion tensor is dominated by a spherical geometry with a residual contribution of the non-spherical components, both, fraction of perfusion and pseudo-diffusion, present a substantial (in the order of 30%) contribution of planar and linear components to the tensor metrics. This study shows that the IVIM perfusion estimates in the cerebral gray matter present a detectable deviation from the spherical model. These non-spherical components may reflect the direction-dependent morphology of the microcirculation. Therefore, the tensor generalization of the IVIM model may provide a tool for the non-invasive monitoring of cerebral capillary micro-architecture during development, aging or in pathologies.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebral/anatomia & histologia , Córtex Cerebral/irrigação sanguínea , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/irrigação sanguínea , Adulto , Anisotropia , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Imagem Ecoplanar , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Microcirculação , Processamento de Sinais Assistido por Computador , Adulto Jovem
11.
J Magn Reson Imaging ; 46(3): 663-677, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28067973

RESUMO

PURPOSE: To assess the feasibility of diffusion tensor imaging (DTI) using simultaneous multislice (SMS) acquisition with blipped controlled aliasing in parallel imaging (CAIPI) for accelerated readout-segmented echo planar imaging (rs-EPI) of the mandibular nerves. DTI of the mandibular nerves using EPI is challenging due to susceptibility artifacts. Rs-EPI is less prone to artifacts but associated with longer scan durations. MATERIALS AND METHODS: Eight asymptomatic volunteers were imaged at 3T using a 64-channel head/neck coil. Conventional, 2-fold (2xSMS) and 3-fold (3xSMS) slice-accelerated rs-EPI sequences were acquired. Tractography of the mandibular nerves was performed. Signal-to-noise ratio (SNR), fractional anisotropy (FA), mean diffusivity (MD), and number of tracts were calculated. Artifacts were evaluated qualitatively on Likert scales. Parameters were compared statistically. Clinical feasibility of 2xSMS rs-EPI was tested in four patients. RESULTS: SNR was similar for conventional (mean ± SD; 8.55 ± 3.90) and 2xSMS rs-EPI (7.83 ± 3.15) but lower for 3xSMS rs-EPI (5.42 ± 2.93; analysis of variance, P = 0.004). FA was similar for all sequences (rs-EPI, 0.42 ± 0.08; 2xSMS rs-EPI, 0.43 ± 0.08; 3xSMS rs-EPI, 0.44 ± 0.06), while 3xSMS rs-EPI showed lower MD (rs-EPI, 0.0015 ± 0.0003; 2xSMS rs-EPI, 0.0014 ± 0.0001; 3xSMS rs-EPI, 0.0013 ± 0.0003) and lower number of tracts (rs-EPI, 66.56 ± 51.31; 2xSMS rs-EPI, 65.75 ± 55.40; 3xSMS rs-EPI, 37.93 ± 52.42) compared to rs-EPI and 2xSMS rs-EPI. Additionally, 2xSMS rs-EPI was feasible in four clinical patients and provided robust imaging results. CONCLUSION: 2xSMS rs-EPI yielded similar SNR, FA, and MD values compared to conventional rs-EPI at reduced scan time and is feasible in clinical patients. These findings suggest the potential clinical applicability of rs-EPI for DTI of the mandibular nerve. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:663-677.


Assuntos
Imagem de Tensor de Difusão/métodos , Imagem Ecoplanar/métodos , Processamento de Imagem Assistida por Computador/métodos , Nervo Mandibular/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
12.
Eur Radiol ; 27(1): 393-403, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27097792

RESUMO

OBJECTIVES: To determine the association between traumatic bone marrow abnormalities, the knee injury mechanism, and associated soft tissue injuries in a larger cohort than those in the published literature. METHOD: Retrospective study including 220 patients with traumatic knee injuries. Knee MRIs were evaluated for trauma mechanism, soft tissue injury, and the location of bone marrow abnormalities. The locations of the abnormalities were correlated with trauma mechanisms and soft tissue injuries using the chi-square test with Bonferroni correction. RESULTS: One hundred and forty-four valgus injuries, 39 pivot shift injuries, 25 lateral patellar dislocations, 8 hyperextensions, and 4 dashboard injuries were included. Valgus and pivot shift injuries showed traumatic bone marrow abnormalities in the posterolateral regions of the tibia. Abnormalities after patellar dislocation were found in the anterolateral and centrolateral femur and patella. Hyperextension injuries were associated with abnormalities in almost all regions, and dashboard injuries were associated with changes in the anterior regions of the tibia and femur. CONCLUSIONS: Our study provides evidence of associations between traumatic bone marrow abnormality patterns and different trauma mechanisms in acute knee injury, and reveals some overlap, especially of the two most common trauma mechanisms (valgus and pivot shift), in a large patient cohort. KEY POINTS: • Specific bone marrow oedema patterns after knee trauma were confirmed. • New associations between bone marrow oedema patterns and knee trauma were shown. • Bone marrow oedema patterns help in identifying associated soft tissue injuries.


Assuntos
Medula Óssea/diagnóstico por imagem , Medula Óssea/lesões , Traumatismos do Joelho/complicações , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
13.
Eur Radiol ; 27(2): 454-463, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27221562

RESUMO

OBJECTIVES: To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. METHODS: Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. RESULTS: Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between к = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. CONCLUSION: Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. KEY POINTS: • FPCT shoulder arthrography is feasible with fluoroscopy and CT in one workflow. • A 5-s FPCT protocol applies a lower radiation dose than MDCT. • A 20-s FPCT protocol is moderately sensitive for cartilage and tendon pathology.


Assuntos
Artrografia/instrumentação , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas
14.
AJR Am J Roentgenol ; 208(1): 159-164, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27762599

RESUMO

OBJECTIVE: The purpose of this study was to quantitatively and qualitatively determine the impact of radiation dose reduction on the image noise and quality of tomosynthesis studies of the wrist. MATERIALS AND METHODS: Imaging of six cadaver wrists was performed with tomosynthesis in anteroposterior position at a tube voltage of 60 kV and tube current of 80 mA and subsequently at 60 or 50 kV with different tube currents of 80, 40, or 32 mA. Dose-area products (DAP) were obtained from the electronically logged protocol. Image noise was measured with an ROI. Two independent and blinded readers evaluated all images. Interreader agreement was measured with a Cohen kappa. Readers assessed overall quality and delineation of soft tissue, cortical bone, and trabecular bone on a 4-point Likert scale. RESULTS: The highest DAP (3.892 ± 0.432 Gy · cm2) was recorded for images obtained with 60 kV and 80 mA; the lowest (0.857 ± 0.178 Gy · cm2) was recorded for images obtained with 50 kV and 32 mA. Noise was highest when a combination of 50 kV and 32 mA (389 ± 26.6) was used and lowest when a combination of 60 kV and 80 mA (218 ± 12.3) was used. The amount of noise on images acquired using 60 kV and 80 mA was statistically significantly different from the amount measured on all other images (p < 0.0001). Interreader agreement was excellent (κ = 0.93). Delineation of anatomy and overall quality were scored best on images obtained with 60 kV and 80 mA and worst on images obtained with 50 kV and 32 mA. The difference in delineation and quality on images obtained using 50 kV and 40 mA was not statistically significantly different compared with images obtained using 60 kV and 80 mA. CONCLUSION: Significant dose reduction for tomosynthesis of the wrist is possible while image quality and delineation of anatomic structures remain preserved.


Assuntos
Doses de Radiação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Articulação do Punho/diagnóstico por imagem , Punho/diagnóstico por imagem , Idoso , Cadáver , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego
15.
Eur Spine J ; 26(2): 353-361, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27334492

RESUMO

PURPOSE: To assess the inter- and intra-reader agreement of commonly used quantitative and qualitative image parameters for the assessment of degenerative lumbar spinal canal stenosis (LSS) by magnetic resonance imaging (MRI). METHODS: In this ethical board approved cross-sectional multicenter study, MRI of 100 randomly selected patients (median age 72.5 years, 48 % female) of the prospective Lumbar Stenosis Outcome Study (LSOS) were evaluated by two independent readers. A set of five previously published core imaging parameters as well as nine qualitative and five quantitative additional parameters regarding LSS and degenerative changes of the lumbar spine were assessed to calculate κ and intraclass correlation coefficients (ICC) for the inter-reader agreement. Additional repeated image evaluations were performed by one reader to calculate the intra-reader agreement. RESULTS: κ values for the core image parameters ranged between 0.42 (compromise of the foraminal zone) and 0.77 (relation between fluid and cauda equina) for inter-reader agreement and between 0.59 (compromise of the foraminal zone) and 0.8 (compromise of the central zone) for intra-reader agreement. The inter-reader agreement for the non-core parameters showed κ values of 0.27-0.69 and ICC values of 0.46-0.85. The intra-reader agreement showed κ values of 0.53-0.69 and ICC values of 0.81-0.88. CONCLUSIONS: The inter- and intra-reader agreement of commonly used quantitative and qualitative image parameters for the assessment of LSS showed quite a variability with previously defined core parameters having good to excellent inter- and intra-reader agreements.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estenose Espinal/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
16.
Ann Plast Surg ; 78(1): 67-72, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27801698

RESUMO

The primary goal of the surgical treatment of upper brachial plexus injuries is to restore active elbow flexion. Accordingly, Oberlin's transfer has been frequently performed since 1994 and has influenced the development of other nerve transfers. However, the window of opportunity for nerve transfers remains a subject of controversy. The objective of this study was to assess magnetic resonance (MR) neurographic, clinical and electrophysiological long-term results after Oberlin's transfer. For this purpose, we performed a retrospective follow-up study. Six patients with upper brachial plexus or musculocutaneous nerve injuries were assessed; 2 were iatrogenic nerve injuries following shoulder arthroscopy or neurofibroma resection. Direct and indirect signs of neuropathy were objectified with MR neurography. Moreover, clinical and electrodiagnostic follow-up was performed and all patients completed the Disabilities of Arm, Shoulder and Hand score. Mean follow-up was 48 ± 21.9 (range, 20-73) months. Mean age was 40 ± 11.3 years and mean delay to surgery was 9 ± 3.2 months. All patients were satisfied with the functional results and the median Disabilities of Arm, Shoulder and Hand score was 21 (range, 1-57). Biceps strength was improved in 5 patients from Medical Research Council grade M0 to M4-5 and in one patient to M2-3. The donor nerve showed normal motor and sensory action potentials. Follow-up MR neurography demonstrated biceps reinnervation. Taken together, this study reports good long-term results after Oberlin's transfer. MR neurography represents an excellent, noninvasive preoperative planning tool and can be of high value in selected postoperative cases. The combined evaluation of nerves and muscles may help to indicate nerve transfers in delayed cases.


Assuntos
Plexo Braquial/lesões , Imageamento por Ressonância Magnética , Transferência de Nervo/métodos , Traumatismos dos Nervos Periféricos/cirurgia , Adulto , Plexo Braquial/diagnóstico por imagem , Plexo Braquial/fisiopatologia , Plexo Braquial/cirurgia , Eletromiografia , Feminino , Seguimentos , Músculos Isquiossurais/inervação , Músculos Isquiossurais/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
19.
J Magn Reson Imaging ; 44(2): 393-400, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26854879

RESUMO

PURPOSE: Panoramical radiographs or cone-beam computed tomography (CT) are the standard-of-care in dental imaging to assess teeth, mandible, and mandibular canal pathologies, but do not allow assessment of the inferior alveolar nerve itself nor of its branches. We propose a new technique for "MR neurographic orthopantomograms" exploiting ultrashort echo-time (UTE) imaging of bone and teeth complemented with high-resolution morphological and functional MR neurography. MATERIALS AND METHODS: The Institutional Review Board approved the study in 10 healthy volunteers. Imaging of the subjects mandibles at 3.0T (Magnetom Skyra, Siemens-Healthcare) using a 64-channel head coil with isotropic spatial resolution for subsequent multiplanar reformatting, was performed. Bone images were acquired using a 3D PETRA sequence (TE, 0.07 msec). Morphological nerve imaging was performed using a dedicated 3D PSIF and 3D SPACE STIR sequence. Functional MR neurography was accomplished using a new accelerated diffusion-tensor-imaging (DTI) prototype sequence (2D SMS-accelerated RESOLVE). Qualitative and quantitative image analysis was performed and descriptive statistics are provided. RESULTS: Image acquisition and subsequent postprocessing into the MR neurographic orthopantomogram by overlay of morphological and functional images were feasible in all 10 volunteers without artifacts. All mandibular bones and mandibular nerves were assessable and considered normal. Fiber tractography with quantitative evaluation of physiological diffusion properties of mandibular nerves yielded the following mean ± SD values: fractional anisotropy, 0.43 ± 0.07; mean diffusivity (mm(2) /s), 0.0014 ± 0.0002; axial diffusivity, 0.0020 ± 0.0002, and radial diffusivity, 0.0011 ± 0.0001. CONCLUSION: The proposed technique of MR neurographic orthopantomogram exploiting UTE imaging complemented with high-resolution morphological and functional MR neurography was feasible and allowed comprehensive assessment of osseous texture and neural microarchitecture in a single examination. J. Magn. Reson. Imaging 2016;44:393-400.


Assuntos
Imageamento por Ressonância Magnética/métodos , Mandíbula/diagnóstico por imagem , Mandíbula/inervação , Neuroimagem/métodos , Radiografia Panorâmica/métodos , Dente/diagnóstico por imagem , Dente/inervação , Adulto , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
20.
Eur Radiol ; 26(11): 3989-3999, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26847043

RESUMO

OBJECTIVES: To determine the diagnostic and therapeutic impact of dual-energy computed tomography (DECT) in gout. METHODS: Forty-three patients with (n = 20) and without a history of gout (n = 23) showing non-specific soft tissue deposits underwent DECT after unrewarding arthrocentesis. Two blinded, independent readers evaluated DECT for the presence of urate crystals. Clinical diagnosis, clinically suspected urate crystal locations, diagnostic thinking and therapeutic decisions were noted before and after DECT. Clinical 1-month follow-up was obtained. RESULTS: DECT showed urate in 26/43 patients (60 %). After DECT, clinical diagnosis of gout was withdrawn in 17/43 (40 %) and was maintained in 16/43 patients (37 %). In 10/43 patients (23 %) the diagnosis was maintained, but DECT revealed urate in clinically unsuspected locations. In 23/43 patients (53 %), a treatment-change based on DECT occurred. Changes in diagnostic thinking occurred more frequently in patients without a history of gout (p < 0.001), changes in therapeutic decisions more frequently in patients with a history of gout (p = 0.014). Clinical follow-up indicated beneficial effects of DECT-based diagnoses in 83 % of patients. CONCLUSIONS: In patients with or without a history of gout and a recent suspicion for gouty arthritis with an unrewarding arthrocentesis, DECT has a marked diagnostic and therapeutic impact when hyperdense soft-tissue deposits are present. KEY POINTS: • This study evaluates the concept of evidence-based radiology • In patients with suspected gout, DECT can help clinicians make the diagnosis • DECT has a marked impact on therapy • Clinical follow-up after 1 month indicated reliable results of DECT.


Assuntos
Artrite Gotosa/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ácido Úrico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA