Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 269: 56-71, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38109985

RESUMO

BACKGROUND: To date, there are no randomized, double-blinded clinical trials comparing catheter ablation to DC cardioversion (DCCV) with medical therapy in patients with persistent atrial fibrillation (PersAF). Conducting a large-scale trial to address this question presents considerable challenges, including recruitment, blinding, and implementation. We conducted a pilot study to evaluate the feasibility of conducting a definitive placebo-controlled trial. METHODS: This prospective trial was carried out at Barts Heart Centre, United Kingdom, employing a randomized, double-blinded, placebo-controlled design. Twenty patients with PersAF (duration <2 years) were recruited, representing 10% of the proposed larger trial as determined by a power calculation. The patients were randomized in a 1:1 ratio to receive either PVI ± DCCV (PVI group) or DCCV + Placebo (DCCV group). The primary endpoint of this feasibility study was to evaluate patient blinding. Patients remained unaware of their treatment allocation until end of study. RESULTS: During the study, 35% of patients experienced recurrence of PersAF prior to completion of 12 months follow-up. Blinding was successfully maintained amongst both patients and medical staff. The DCCV group had a trend to higher recurrence and repeat procedure rate compared to the PVI group (recurrence of PersAF 60% vs 30%; p = .07 and repeat procedure 70% vs 40%; p = .4). The quality of life experienced by individuals in the PVI group showed improvement, as evidenced by enhanced scores on the AF specific questionnaire (AF PROMS) (3 [±4] vs 21 [±8]) and SF-12 mental-component raw score (51.4 [±7] vs 43.24 [±15]) in patients who maintained sinus rhythm at 12 months. CONCLUSION: This feasibility study establishes the potential for conducting a blinded, placebo-controlled trial to evaluate the efficacy of PVI versus DCCV in patients with PersAF.


Assuntos
Angina Estável , Fibrilação Atrial , Ablação por Cateter , Intervenção Coronária Percutânea , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos de Viabilidade , Qualidade de Vida , Estudos Prospectivos , Angina Estável/cirurgia , Projetos Piloto , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
2.
J Cardiovasc Electrophysiol ; 34(6): 1350-1359, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36598422

RESUMO

INTRODUCTION: The Heliostar™ ablation system is a novel RF balloon ablation technology with an integrated three-dimensional mapping system. Here, we describe our early experience and procedural outcomes using this technology for atrial fibrillation catheter ablation. METHODS: We sought to comprehensively assess the first 60 consecutive patients undergoing pulmonary vein isolation using the novel HELISOTAR™ RF balloon technology including procedural outcomes. A comparison of the workflow between two different anaesthetic modalities (conscious sedation [CS] vs. general anaesthesia [GA]) was made. Procedural data were collected prospectively from two high-volume centers (Barts Heart Centre, UK and University Hospital of Zurich, Zurich). A standardized approach for catheter ablation was employed. RESULTS: A total of 35 patients had the procedure under CS and the remaining under GA. Mean procedural and fluoroscopy times were 84 ± 33 min and 1.1 min. The median duration of RF energy application was 7 (5-9.8) mins per patient. All veins were successfully isolated, and the median isolation time was 10 (7-15) seconds. Our cohort's rate of procedural complications was low, with no mortality within 30 days postprocedure. CONCLUSION: Our early experience shows that catheter ablation using the Heliostar™ technology can be performed efficiently and safely; however, long-term data is yet to be established. Low fluoroscopy requirements, short learning curves and use of this technology with CS is possible, including the use of an oesophageal temperature probe.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Europa (Continente) , Eletrodos , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
J Cardiovasc Electrophysiol ; 33(3): 510-526, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34921464

RESUMO

INTRODUCTION: Ethanol ablation (EA) is an alternative option for subjects with ventricular arrhythmias (VAs) refractory to conventional medical and ablative treatment. However, data on the efficacy and safety of EA remain sparse. METHODS: A systematic literature search was conducted. The primary outcomes were 1) freedom from the targeted VA and 2) freedom from any VAs post-EA. Additional safety outcomes were also analyzed. RESULTS: Ten studies were selected accounting for a population of 174 patients (62.3 ± 12.5 years, 94% male) undergoing 185 procedures. The overall acute success rate of EA was 72.4% (confidence interval [CI95% ]: 65.6-78.4). After a mean follow-up of 11.3 ± 5.5 months, the incidence of relapse of the targeted VA was 24.4% (CI95% : 17.1-32.8), while any VAs post-EA occurred in 41.3% (CI95% : 33.7-49.1). The overall incidence of procedural complications was 14.1% (CI95% : 9.8-19.8), with pericardial complications and complete atrioventricular block being the most frequent. An anterograde transarterial approach was associated with a higher rate of VA recurrences and complications compared to a retrograde transvenous route; however, differences in the baseline population characteristics and in the targeted ventricular areas should be accounted. CONCLUSION: EA is a valuable therapeutic option for VAs refractory to conventional treatment and can result in 1-year freedom from VA recurrence in 60%-75% of the patients. However, anatomical or technical challenges preclude acute success in almost 30% of the candidates and the rate of complication is not insignificant, highlighting the importance of well-informed patient selection. The certainty of the evidence is low, and further research is necessary.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Etanol/efeitos adversos , Feminino , Ventrículos do Coração , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
4.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35737685

RESUMO

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 44(6): 1039-1046, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33782987

RESUMO

BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2  = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2  = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , Masculino
6.
J Cardiovasc Electrophysiol ; 31(8): 2192-2205, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32495462

RESUMO

AIMS: We sought out to make comparisons between all atrial fibrillation (AF) catheter ablation technologies using randomized controlled trial data. Our comparisons were freedom from AF, procedural duration, and fluoroscopy duration. METHODS: Searches were made of EMBASE, MEDLINE, and CENTRAL databases, and studies were selected which had cryoballoon, conventional radiofrequency (RF), multipolar RF catheters, and laser technology as an arm in the study and were identified as randomized controlled trials (RCTs). These studies were analyzed for direct comparisons using conventional meta-analysis and a combination of indirect and direct comparisons via a network meta-analysis (NMA). RESULTS: With respect to freedom from AF both direct comparisons and NMA did not demonstrate any significant difference. However in analysis of procedural and fluoroscopy duration (minutes) for the pulmonary vein ablation catheter (PVAC), both conventional analysis and NMA revealed significantly shorter procedure times, RF vs PVAC (conventional: 61.99 [38.03-85.94], P <.00001; NMA: 54.76 [36.64-72.88], P < .0001) and fluoroscopy times, RF vs PVAC (conventional: 12.96 [6.40-19.53], P = .0001; NMA: 8.89 [3.27-14.51], P < .01). The procedural duration was also shorter for the cryoballoon with NMA, RF vs CRYO (20.56 [3.47-37.65], P = .02). DISCUSSION: Our analysis demonstrated that while there was no difference in the efficacy of the individual catheter technologies, there are significant differences in the procedural duration for the PVAC and the cryoballoon. While they may seem an attractive solution for high-volume centers, further RCTs of next-generation technologies should be examined.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Metanálise em Rede , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Tecnologia , Resultado do Tratamento
7.
Glia ; 66(6): 1185-1199, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29274121

RESUMO

Astrocytes support neuronal function by providing essential structural and nutritional support, neurotransmitter trafficking and recycling and may also contribute to brain information processing. In this article we review published results and report new data suggesting that astrocytes function as versatile metabolic sensors of central nervous system (CNS) milieu and play an important role in the maintenance of brain metabolic homeostasis. We discuss anatomical and functional features of astrocytes that allow them to detect and respond to changes in the brain parenchymal levels of metabolic substrates (oxygen and glucose), and metabolic waste products (carbon dioxide). We report data suggesting that astrocytes are also sensitive to circulating endocrine signals-hormones like ghrelin, glucagon-like peptide-1 and leptin, that have a major impact on the CNS mechanisms controlling food intake and energy balance. We discuss signaling mechanisms that mediate communication between astrocytes and neurons and consider how these mechanisms are recruited by astrocytes activated in response to various metabolic challenges. We review experimental data suggesting that astrocytes modulate the activities of the respiratory and autonomic neuronal networks that ensure adaptive changes in breathing and sympathetic drive in order to support the physiological and behavioral demands of the organism in ever-changing environmental conditions. Finally, we discuss evidence suggesting that altered astroglial function may contribute to the pathogenesis of disparate neurological, respiratory and cardiovascular disorders such as Rett syndrome and systemic arterial hypertension.


Assuntos
Astrócitos/metabolismo , Encéfalo/metabolismo , Animais , Humanos
8.
Small ; 12(14): 1909-19, 2016 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-26917414

RESUMO

Circulating tumor cells (CTCs) offer tremendous potential for the detection and characterization of cancer. A key challenge for their isolation and subsequent analysis is the extreme rarity of these cells in circulation. Here, a novel label-free method is described to enrich viable CTCs directly from whole blood based on their distinct deformability relative to hematological cells. This mechanism leverages the deformation of single cells through tapered micrometer scale constrictions using oscillatory flow in order to generate a ratcheting effect that produces distinct flow paths for CTCs, leukocytes, and erythrocytes. A label-free separation of circulating tumor cells from whole blood is demonstrated, where target cells can be separated from background cells based on deformability despite their nearly identical size. In doping experiments, this microfluidic device is able to capture >90% of cancer cells from unprocessed whole blood to achieve 10(4) -fold enrichment of target cells relative to leukocytes. In patients with metastatic castration-resistant prostate cancer, where CTCs are not significantly larger than leukocytes, CTCs can be captured based on deformability at 25× greater yield than with the conventional CellSearch system. Finally, the CTCs separated using this approach are collected in suspension and are available for downstream molecular characterization.


Assuntos
Microfluídica/instrumentação , Células Neoplásicas Circulantes , Humanos
9.
Curr Cardiol Rep ; 17(9): 631, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26266757

RESUMO

Catheter ablation is superior to antiarrhythmic drugs in maintaining sinus rhythm for patients with atrial fibrillation (AF). Pulmonary vein (PV) isolation is the cornerstone of any AF ablation procedure. Conventionally, this is achieved by performing point by point lesions using radiofrequency (RF) energy. However, this is technically challenging, time consuming and is associated with a number of complications. Long-term durability of PV isolation is also a concern. To address these issues, 'one-shot' energy delivery systems and alternative energy sources have been developed. The cryoballoon system has emerged as the most commonly used alternative to point by point RF technology. In this paper, we compare the technology, biophysics and clinical data of cryoballoon to conventional RF ablation for AF. The safety and efficacy of cryoballoon compared to RF ablation is critically reviewed. We conclude by looking at future applications of this technology.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/patologia , Fibrilação Atrial/fisiopatologia , Humanos , Veias Pulmonares/inervação , Resultado do Tratamento
11.
Am J Physiol Regul Integr Comp Physiol ; 305(4): R435-42, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23697798

RESUMO

Reciprocal physiological modulation of heart rate is controlled by the sympathetic and parasympathetic systems acting on the sinoatrial (SA) node. However, there is little direct in vivo work examining the role of stimulatory and inhibitory G protein signaling in the SA node. Thus, we designed a study to examine the role of the stimulatory (Gαs) and inhibitory G protein (Gαi2) in in vivo heart rate regulation in the SA node in the mouse. We studied mice with conditional deletion of Gαs and Gαi2 in the conduction system using cre-loxP technology. We crossed mice in which cre recombinase expression was driven by a tamoxifen-inducible conduction system-specific construct with "Gαs floxed" and "Gαi2 floxed" mice. We studied the heart rate responses of adult mice compared with littermate controls by using radiotelemetry before and after administration of tamoxifen. The mice with conditional deletion of Gαs and Gαi2 had a loss of diurnal variation and were bradycardic or tachycardic, respectively, in the daytime. In mice with conditional deletion of Gαs, there was a selective loss of low-frequency power, while with deletion of Gαi2, there was a loss of high-frequency power in power spectral analysis of heart rate variability. There was no evidence of pathological arrhythmia. Pharmacological modulation of heart rate by isoprenaline was impaired in the Gαs mice, but a muscarinic agonist was still able to slow the heart rate in Gαi2 mice. We conclude that Gαs- and Gαi2-mediated signaling in the sinoatrial node is important in the reciprocal regulation of heart rate through the autonomic nervous system.


Assuntos
Subunidade alfa Gi2 de Proteína de Ligação ao GTP/metabolismo , Subunidades alfa Gs de Proteínas de Ligação ao GTP/metabolismo , Frequência Cardíaca , Nó Sinoatrial/metabolismo , Agonistas Adrenérgicos beta/farmacologia , Animais , Sistema Nervoso Autônomo/metabolismo , Sistema Nervoso Autônomo/fisiopatologia , Bradicardia/metabolismo , Bradicardia/fisiopatologia , Cromograninas , Ritmo Circadiano , Eletrocardiografia Ambulatorial/métodos , Subunidade alfa Gi2 de Proteína de Ligação ao GTP/deficiência , Subunidade alfa Gi2 de Proteína de Ligação ao GTP/genética , Subunidades alfa Gs de Proteínas de Ligação ao GTP/deficiência , Subunidades alfa Gs de Proteínas de Ligação ao GTP/genética , Frequência Cardíaca/efeitos dos fármacos , Integrases/genética , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Transgênicos , Agonistas Muscarínicos/farmacologia , Transdução de Sinais , Nó Sinoatrial/efeitos dos fármacos , Nó Sinoatrial/inervação , Nó Sinoatrial/fisiopatologia , Taquicardia/metabolismo , Taquicardia/fisiopatologia , Telemetria , Fatores de Tempo
12.
Eur Heart J Case Rep ; 7(9): ytad411, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37743895

RESUMO

Background: Coronary compromise is a serious potential complication following catheter ablation; however, procedural details in the literature are often lacking, preventing the identification of learning opportunities. Case summary: We report two cases of right coronary compromise following catheter ablation for symptomatic supraventricular tachycardia. After radiofrequency energy delivery at the coronary sinus ostium in both cases, inferior lead ST-elevation was observed. Diagnostic coronary angiography identified an occluded posterior left ventricular branch of the coronary artery, and optical coherence tomography demonstrated a high thrombus burden at this location. Electrocardiographic ST-segments settled with implantation of a drug-eluting stent. Discussion: Coronary compromise was likely secondary to energy delivery during catheter ablation. This case series highlights the need for electrophysiologist to understand coronary anatomy relative to anatomical landmarks, to anticipate the risk of vascular injury as physical distance from the site of ablation is likely important. Risk for coronary compromise, while a rare complication, needs to be discussed with patients during the consenting process. We also demonstrate the importance of an efficient multi-disciplinary team process for managing acute procedural complications.

13.
J Interv Card Electrophysiol ; 63(2): 259-266, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33638777

RESUMO

PURPOSE: A significant proportion of patients undergoing catheter ablation for atrial fibrillation (AF) experience arrhythmia recurrence. This is mostly due to pulmonary vein reconnection (PVR). Whether mapping using High-Density Wave (HDW) technology is superior to standard bipolar (SB) configuration at detecting PVR is unknown. We aimed to evaluate the efficacy of HDW technology compared to SB mapping in identifying PVR. METHODS: High-Density (HD) multipolar Grid catheters were used to create left atrial geometries and voltage maps in 36 patients undergoing catheter ablation for AF (either due to recurrence of an atrial arrhythmia from previous AF ablation or de novo AF ablation). Nineteen SB maps were also created and compared. Ablation was performed until pulmonary vein isolation was achieved. RESULTS: Median time of mapping with HDW was 22.3 [IQR: 8.2] min. The number of points collected with HDW (13299.6±1362.8 vs 6952.8±841.9, p<0.001) and used (2337.3±158.0 vs 1727.5±163.8, p<0.001) was significantly higher compared to SB. Moreover, HDW was able to identify more sleeves (16 for right and 8 for left veins), where these were confirmed electrically silent by SB, with significantly increased PVR sleeve size as identified by HDW (p<0.001 for both right and left veins). Importantly, with the use of HDW, the ablation strategy changed in 23 patients (64% of targeted veins) with a significantly increased number of lesions required as compared to SB for right (p=0.005) and left veins (p=0.003). CONCLUSION: HDW technology is superior to SB in detecting pulmonary vein reconnections. This could potentially result into a significant change in ablation strategy and possibly to increased success rate following pulmonary vein isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Técnicas Eletrofisiológicas Cardíacas , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
15.
Europace ; 12(12): 1691-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20823042

RESUMO

AIMS: To investigate the impact of variant pulmonary vein (PV) anatomy and the use of three-dimensional image integration (3D-II) on long-term efficacy of catheter ablation for atrial fibrillation (AF). METHODS: Consecutive procedures from 2002 to 2007 were analysed from a prospective database. All patients underwent wide area circumferential ablation, with linear lesions added and complex fractionated electrograms targeted for persistent AF. Imaging was segmented on Carto to assess PV anatomy. RESULTS: Three hundred and fifty patients underwent 1.9 ± 0.9 procedures. The mean age was 57 ± 11 years, 73% males, and 55% paroxysmal AF. Freedom from AF/atrial tachycardia was 42% for paroxysmal AF and 20% for persistent AF at 3.1 years after the first procedure, or 86 and 66%, respectively, at 2.5 years after the last procedure. The Kaplan-Meier analysis showed a trend towards improved single-procedure efficacy with 3D-II (8.9% difference, P = 0.087) and a reduction in the number of procedures per patient from 2.1 ± 1.1 to 1.8 ± 0.9 (P < 0.0001). The use of 3D-II improved single-procedure efficacy with Carto (13.3% difference, P = 0.018), but not with Ensite NavX. Variant PV anatomy was identified in 28% and was associated with a lower single-procedure efficacy (10.0% difference, P = 0.024) but with no effect on final outcome. Multivariate analysis confirmed the impact of 3D-II [hazard ratio (HR) for recurrence of AF 0.67, P = 0.020] and variant PV anatomy (HR 1.37, P = 0.044). CONCLUSION: The use of 3D-II improves single-procedure efficacy of PV isolation for AF. Variant PV anatomy was associated with a lower single-procedure success rate.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Imageamento Tridimensional/métodos , Veias Pulmonares/patologia , Idoso , Fibrilação Atrial/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
16.
Front Physiol ; 11: 236, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32256390

RESUMO

Sudden cardiac death caused by ventricular arrhythmias is among the leading causes of mortality, with approximately half of all deaths attributed to heart disease worldwide. Periodic repolarization dynamics (PRD) is a novel marker of repolarization instability and strong predictor of death in patients post-myocardial infarction that is believed to occur in association with low-frequency oscillations in sympathetic nerve activity. However, this hypothesis is based on associations of PRD with indices of sympathetic activity that are not directly linked to cardiac function, such as muscle vasoconstrictor activity and the variability of cardiovascular autospectra. In this review article, we critically evaluate existing scientific evidence obtained primarily in experimental animal models, with the aim of identifying the neuronal networks responsible for the generation of low-frequency sympathetic rhythms along the neurocardiac axis. We discuss the functional significance of rhythmic sympathetic activity on neurotransmission efficacy and explore its role in the pathogenesis of ventricular repolarization instability. Most importantly, we discuss important gaps in our knowledge that require further investigation in order to confirm the hypothesis that low frequency cardiac sympathetic oscillations play a causative role in the generation of PRD.

17.
J Mol Med (Berl) ; 98(8): 1149-1160, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32632751

RESUMO

KATP channels in the vasculature composed of Kir6.1 regulate vascular tone and may contribute to the pathogenesis of endotoxemia. We used mice with cell-specific deletion of Kir6.1 in smooth muscle (smKO) and endothelium (eKO) to investigate this question. We found that smKO mice had a significant survival disadvantage compared with their littermate controls when treated with a sub-lethal dose of lipopolysaccharide (LPS). All cohorts of mice became hypotensive following bacterial LPS administration; however, mean arterial pressure in WT mice recovered to normal levels, whereas smKO struggled to overcome LPS-induced hypotension. In vivo and ex vivo investigations revealed pronounced cardiac dysfunction in LPS-treated smKO, but not in eKO mice. Similar results were observed in a cecal slurry injection model. Metabolomic profiling of hearts revealed significantly reduced levels of metabolites involved in redox/energetics, TCA cycle, lipid/fatty acid and amino acid metabolism. Vascular smooth muscle-localised KATP channels have a critical role in the response to systemic infection by normalising cardiac function and haemodynamics through metabolic homeostasis. KEY MESSAGES: • Mice lacking vascular KATP channels are more susceptible to death from infection. • Absence of smooth muscle KATP channels depresses cardiac function during infection. • Cardiac dysfunction is accompanied by profound changes in cellular metabolites. • Findings from this study suggest a protective role for vascular KATP channels in response to systemic infection.


Assuntos
Endotoxemia/etiologia , Endotoxemia/metabolismo , Metabolismo Energético , Canais KATP/metabolismo , Miocárdio/metabolismo , Animais , Modelos Animais de Doenças , Suscetibilidade a Doenças , Endotoxemia/complicações , Cardiopatias/etiologia , Cardiopatias/metabolismo , Cardiopatias/fisiopatologia , Testes de Função Cardíaca , Canais KATP/genética , Lipopolissacarídeos/efeitos adversos , Camundongos , Camundongos Knockout , Modelos Biológicos , Músculo Liso Vascular/metabolismo , Miócitos Cardíacos/metabolismo
18.
JACC Clin Electrophysiol ; 6(14): 1783-1793, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357574

RESUMO

OBJECTIVES: The goal of this study was to evaluate the role of dynamic substrate changes in facilitating conduction delay and re-entry in ventricular tachycardia (VT) circuits. BACKGROUND: The presence of dynamic substrate changes facilitate functional block and re-entry in VT but are rarely studied as part of clinical VT mapping. METHODS: Thirty patients (age 67 ± 9 years; 27 male subjects) underwent ablation. Mapping was performed with the Advisor HD Grid multipolar catheter. A bipolar voltage map was obtained during sinus rhythm (SR) and right ventricular sense protocol (SP) single extra pacing. SR and SP maps of late potentials (LP) and local abnormal ventricular activity (LAVA) were made and compared with critical sites for ablation, defined as sites of best entrainment or pace mapping. Ablation was then performed to critical sites, and LP/LAVA identified by the SP. RESULTS: At a median follow-up of 12 months, 90% of patients were free from antitachycardia pacing (ATP) or implantable cardioverter-defibrillator shocks. SP pacing resulted in a larger area of LP identified for ablation (19.3 mm2 vs. 6.4 mm2) during SR mapping (p = 0.001), with a sensitivity of 87% and a specificity of 96%, compared with 78% and 65%, respectively, in SR. CONCLUSIONS: LP and LAVA observed during the SP were able to identify regions critical for ablation in VT with a greater accuracy than SR mapping. This may improve substrate characterization in VT ablation. The combination of ablation to critical sites and SP-derived LP/LAVA requires further assessment in a randomized comparator study.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ventrículos do Coração/cirurgia , Humanos , Masculino , Taquicardia Ventricular/cirurgia
19.
J Cereb Blood Flow Metab ; 39(10): 2089-2095, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-29862863

RESUMO

KIR6.1 (KCNJ8) is a subunit of ATP sensitive potassium channel (KATP) that plays an important role in the control of peripheral vascular tone and is highly expressed in brain contractile cells (vascular smooth muscle cells and pericytes). This study determined the effect of global deletion of the KIR6.1 subunit on cerebral blood flow, neurovascular coupling and cerebral oxygenation in mice. In KIR6.1 deficient mice resting cerebral blood flow and brain parenchymal partial pressure of oxygen (PO2) were found to be markedly lower compared to that in their wildtype littermates. However, cortical blood oxygen level dependent responses triggered by visual stimuli were not affected in conditions of KIR6.1 deficiency. These data suggest that KATP channels containing KIR6.1 subunit are critically important for the maintenance of normal cerebral perfusion and parenchymal PO2 but play no significant role in the mechanisms underlying functional changes in brain blood flow.


Assuntos
Encéfalo/metabolismo , Circulação Cerebrovascular , Canais KATP/metabolismo , Oxigênio/metabolismo , Trifosfato de Adenosina/metabolismo , Animais , Encéfalo/irrigação sanguínea , Masculino , Camundongos , Oxigênio/sangue
20.
J Cardiovasc Dev Dis ; 5(4)2018 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-30249045

RESUMO

Haploinsufficiency of the T-box transcription factor TBX1 is responsible for many features of 22q11.2 deletion syndrome. Tbx1 is expressed dynamically in the pharyngeal apparatus during mouse development and Tbx1 homozygous mutants display numerous severe defects including abnormal cranial ganglion formation and neural crest cell defects. These abnormalities prompted us to investigate whether parasympathetic (vagal) innervation of the heart was affected in Tbx1 mutant embryos. In this report, we used an allelic series of Tbx1 mouse mutants, embryo tissue explants and cardiac electrophysiology to characterise, in detail, the function of Tbx1 in vagal innervation of the heart. We found that total nerve branch length was significantly reduced in Tbx1+/- and Tbx1neo2/- mutant hearts expressing 50% and 15% levels of Tbx1. We also found that neural crest cells migrated normally to the heart of Tbx1+/-, but not in Tbx1neo2 mutant embryos. In addition, we showed that cranial ganglia IXth and Xth were fused in Tbx1neo2/- but neuronal differentiation appeared intact. Finally, we used telemetry to monitor heart response to carbachol, a cholinergic receptor agonist, and found that heart rate recovered more quickly in Tbx1+/- animals versus controls. We speculate that this condition of decreased parasympathetic drive could result in a pro-arrhythmic substrate in some 22q11.2DS patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA