Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
World J Urol ; 38(11): 2971-2979, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31993735

RESUMO

PURPOSE: To assess a novel low-dose CT-protocol, combining a 150 kV spectral filtration unenhanced protocol (Sn150 kVp) and a stone-targeted dual-energy CT (DECT) in patients with urolithiasis. METHODS: 232 (151 male, 49 ± 16.4 years) patients with urolithiasis received a low-dose non-contrast enhanced CT (NCCT) for suspected urinary stones either on a third-generation dual-source CT system (DSCT) using Sn150 kVp (n = 116, group 1), or on a second-generation DSCT (n = 116 group 2) using single energy (SE) 120 kVp. For group 1, a subsequent dual-energy CT (DECT) with a short stone-targeted scan range was performed. Objective and subjective image qualities were assessed. Radiation metrics were compared. RESULTS: 534 stones (group 1: n = 242 stones; group 2: n = 292 stones) were found. In group 1, all 215 stones within the stone-targeted DECT-scan range were identified. DE analysis was able to distinguish between UA and non-UA calculi in all collected stones. 11 calculi (5.12%) were labeled as uric acid (UA) while 204 (94.88%) were labeled as non-UA calculi. There was no significant difference in overall Signal-to-noise-ratio between group 1 and group 2 (p = 0.819). On subjective analysis both protocols achieved a median Likert rating of 2 (p = 0.171). Mean effective dose was significantly lower for combined Sn150 kVp and stone-targeted DECT (3.34 ± 1.84 mSv) compared to single energy 120 kVp NCCT (4.45 ± 2.89 mSv) (p < 0.001), equaling a 24.9% dose reduction. CONCLUSION: The evaluated novel low-dose stone composition protocol allows substantial radiation dose reduction with consistent high diagnostic image quality.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
2.
Eur Radiol ; 29(7): 3617-3625, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30888484

RESUMO

OBJECTIVES: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC). METHODS: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient. RESULTS: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement. CONCLUSION: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC. KEY POINTS: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.


Assuntos
Algoritmos , Carcinoma Ductal Pancreático/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Realidade Virtual , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1552-1561, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-29881885

RESUMO

PURPOSE: To evaluate the influence of different scan parameters for single-energy CT and dual-energy CT, as well as the impact of different material used in a TKA prosthesis on image quality and the extent of metal artifacts. METHODS: Eight pairs of TKA prostheses from different vendors were examined in a phantom set-up. Each pair consisted of a conventional CoCr prosthesis and the corresponding anti-allergic prosthesis (full titanium, ceramic, or ceramic-coated) from the same vendor. Nine different (seven dual-energy CT and two single-energy CT) scan protocols with different characteristics were used to determine the most suitable CT protocol for TKA imaging. Quantitative image analysis included assessment of blooming artifacts (metal implants appear thicker on CT than they are, given as virtual growth in mm in this paper) and streak artifacts (thick dark lines around metal). Qualitative image analysis was used to investigate the bone-prosthesis interface. RESULTS: The full titanium prosthesis and full ceramic knee showed significantly fewer blooming artifacts compared to the standard CoCr prosthesis (mean virtual growth 0.6-2.2 mm compared to 2.9-4.6 mm, p < 0.001). Dual-energy CT protocols showed less blooming (range 3.3-3.8 mm) compared to single-energy protocols (4.6-5.5 mm). The full titanium and full ceramic prostheses showed significantly fewer streak artifacts (mean standard deviation 77-86 Hounsfield unit (HU)) compared to the standard CoCr prosthesis (277-334 HU, p < 0.001). All dual-energy CT protocols had fewer metal streak artifacts (215-296 HU compared to single-energy CT protocols (392-497 HU)). Full titanium and ceramic prostheses were ranked superior with regard to the image quality at the bone/prosthesis interface compared to a standard CoCr prosthesis, and all dual-energy CT protocols were ranked better than single-energy protocols. CONCLUSIONS: Dual-energy CT and ceramic or titanium prostheses reduce CT artifacts and provide superior image quality of total knee arthroplasty at the bone/prosthesis interface. These findings support the use of dual-energy CT as a solid imaging base for clinical decision-making and the use of full-titanium or ceramic prostheses to allow for better CT visualization of the bone-prosthesis interface.


Assuntos
Artroplastia do Joelho , Artefatos , Metais/química , Interpretação de Imagem Radiográfica Assistida por Computador , Titânio/química , Cerâmica/química , Ligas de Cromo/química , Materiais Revestidos Biocompatíveis/química , Simulação por Computador , Humanos , Imagens de Fantasmas , Próteses e Implantes , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
4.
Eur Radiol ; 28(7): 3097-3104, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29404770

RESUMO

OBJECTIVES: To investigate diagnostic accuracy and radiation dose of high-pitch CT coronary artery calcium scoring (CACS) with tin filtration (Sn100kVp) versus standard 120kVp high-pitch acquisition. METHODS: 78 patients (58% male, 61.5±9.1 years) were prospectively enrolled. Subjects underwent clinical 120kVp high-pitch CACS using third-generation dual-source CT followed by additional high-pitch Sn100kVp acquisition. Agatston scores, calcium volume scores, Agatston score categories, percentile-based risk categorization and radiation metrics were compared. RESULTS: 61/78 patients showed coronary calcifications. Median Agatston scores were 34.9 [0.7-197.1] and 41.7 [0.7-207.2] and calcium volume scores were 34.1 [0.7-218.0] for Sn100kVp and 35.7 [1.1-221.0] for 120kVp acquisitions, respectively (both p<0.0001). Bland-Altman analysis revealed underestimated Agatston scores and calcium volume scores with Sn100kVp versus 120kVp acquisitions (mean difference: 16.4 and 11.5). However, Agatston score categories and percentile-based risk categories showed excellent agreement (ĸ=0.98 and ĸ=0.99). Image noise was 25.8±4.4HU and 16.6±2.9HU in Sn100kVp and 120kVp scans, respectively (p<0.0001). Dose-length-product was 9.9±4.8mGy*cm and 40.9±14.4mGy*cm with Sn100kVp and 120kVp scans, respectively (p<0.0001). This resulted in significant effective radiation dose reduction (0.13±0.07mSv vs. 0.57±0.2mSv, p<0.0001) for Sn100kVp acquisitions. CONCLUSION: CACS using high-pitch low-voltage tin-filtered acquisitions demonstrates excellent agreement in Agatston score and percentile-based cardiac risk categorization with standard 120kVp high-pitch acquisitions. Furthermore, radiation dose was significantly reduced by 78% while maintaining accurate risk prediction. KEY POINTS: • Coronary artery calcium scoring with tin filtration reduces radiation dose by 78%. • There is excellent correlation between high-pitch Sn100kVp and standard 120kVp acquisitions. • Excellent agreement regarding Agatston score categories and percentile-based risk categorization was achieved. • No cardiac risk reclassifications were observed using Sn100kVp coronary artery calcium scoring.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Cálcio , Feminino , Filtração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco/métodos , Estanho
5.
Eur Radiol ; 28(11): 4766-4774, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29761359

RESUMO

OBJECTIVES: To assess whether electronic cleansing (EC) of tagged residue and different computed tomography (CT) windows influence the size of colorectal polyps in CT colonography (CTC). METHODS: A database of 894 colonoscopy-validated CTC datasets of a low-prevalence cohort was retrospectively reviewed to identify patients with polyps ≥6 mm that were entirely submerged in tagged residue. Ten radiologists independently measured the largest diameter of each polyp, two-dimensionally, before and after EC in colon, bone, and soft-tissue-windows, in randomised order. Differences in size and polyp count before and after EC were calculated for size categories ≥6 mm and ≥10 mm. Statistical testing involved 95% confidence interval, intraclass correlation and mixed-model ANOVA. RESULTS: Thirty-seven patients with 48 polyps were included. Mean polyp size before EC was 9.8 mm in colon, 9.9 mm in bone and 8.2 mm in soft-tissue windows. After EC, the mean polyp size decreased significantly to 9.4 mm in colon, 9.1 mm in bone and 7.1 mm in soft-tissue windows. Compared to unsubtracted colon windows, EC, performed in colon, bone and soft-tissue windows, led to a shift of 6 (12,5%), 10 (20.8%) and 25 (52.1%) polyps ≥6 mm into the next smaller size category, thus affecting patient risk stratification. CONCLUSIONS: EC and narrow CT windows significantly reduce the size of polyps submerged in tagged residue. Polyp measurements should be performed in unsubtracted colon windows. KEY POINTS: • EC significantly reduces the size of polyps submerged in tagged residue. • Abdominal CT-window settings significantly underestimate 2D sizes of submerged polyps. • Size reduction in EC is significantly greater in narrow than wide windows. • Underestimation of polyp size due to EC may lead to inadequate treatment. • Polyp measurements should be performed in unsubtracted images using a colon window.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Idoso , Algoritmos , Análise de Variância , Colonografia Tomográfica Computadorizada/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Eur Radiol ; 27(6): 2292-2297, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27686566

RESUMO

OBJECTIVES: To investigate the relationship between image quality and patient size at 100 kilovoltage (kV) compared to 120 kV ECG-gated Triple-Rule-Out CT angiography (TRO-CTA). METHODS: We retrospectively included 73 patients (age 64 ± 14 years) who underwent retrospective ECG-gated chest CTA. 40 patients were scanned with 100 kV while 33 patients with 120 kV. Body mass index (BMI), patients' chest circumference (PC) and thoracic surface area (TSA) were recorded. Quantitative image quality was assessed as vascular attenuation in the ascending aorta (AA), pulmonary trunk (PA) and left coronary artery (LCA) and the signal-to-noise ratio (SNR) in the AA. RESULTS: There was no significant difference in BMI (26.0 ± 4.6 vs. 28.0 ± 6.7 kg/m2), PC (103 ± 7 vs. 104 ± 10 cm2) and TSA (92 ± 15 vs. 91 ± 19 cm2) between 100 kV and 120 kV group. Mean vascular attenuation was significantly higher in the 100 kV compared to the 120 kV group (AA 438 vs. 354 HU, PA 460 vs. 349 HU, LCA 370 vs. 299 HU all p < 0.001). SNR was not significantly different, even after adjusting for patient size. Radiation dose was significantly lower in the 100 kV group (10.7 ± 4.1 vs. 20.7 ± 10.7 mSv; p < 0.001). CONCLUSIONS: 100 kV TRO-CTA is feasible in normal-to-overweight patients while maintaining image quality and achieving substantial dose reduction. KEY POINTS: • 100 kV protocols result in a significantly lower radiation dose. • Mean vascular attenuation is significantly higher using 100 kV. • SNR and CNR are not significantly different between 100 kV and 120 kV. • 100 kV CTA is feasible regardless of patient size while maintaining image quality.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Sobrepeso/diagnóstico por imagem , Aorta/diagnóstico por imagem , Índice de Massa Corporal , Tamanho Corporal , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído
8.
Radiology ; 270(2): 387-93, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24471388

RESUMO

PURPOSE: To investigate in vitro and in vivo the use of image-based and raw data-based iterative reconstruction algorithms for quantification of coronary artery calcium by using the Agatston score and subsequent cardiac risk stratification. MATERIALS AND METHODS: In vitro data were obtained by using a moving anthropomorphic cardiac phantom containing calcium inserts of different concentrations and sizes. With institutional review board approval and HIPAA compliance, coronary calcium imaging data of 110 consecutive patients (mean age ± standard deviation, 58.2 years ± 9.8; 48 men) were reconstructed with filtered back projection (FBP), iterative reconstruction in image space (IRIS), and sinogram-affirmed iterative reconstruction (SAFIRE). Image noise was measured and the Agatston score was obtained for all reconstructions. Assignment to Agatston scores and percentile-based cardiac risk categories was compared. Statistical analysis included the Cohen κ coefficient and Friedman and Wilcoxon testing. RESULTS: In vitro, mean Agatston scores ± standard deviation for FBP (638.9 ± 9.6), IRIS (622.7 ± 15.2), and SAFIRE (631.4 ± 17.6) were comparable (P = .30). The smallest phantom calcifications were more frequently detected when iterative reconstruction techniques were used. The Agatston scores in the patient cohort were not significantly different among FBP, IRIS, and SAFIRE in paired comparisons (median Agatston score [25th and 75th percentiles]: 76.0 [20.6, 243.9], 76.4 [22, 249.3], and 75.7 [21.5, 49.1], respectively; P = .20 each). Comparison of categorization based on Agatston score percentiles showed excellent agreement for both IRIS and SAFIRE with FBP (κ = 0.975 [0.942-1.00] and κ = 0.963 [0.922-1.00], respectively). The mean effective dose was 1.02 mSv ± 0.51. Mean image noise was significantly (P < .001) higher with FBP than that with iterative reconstructions. CONCLUSION: In comparison with FBP, iterative reconstruction techniques do not have a profound effect on the reproducible quantification of coronary calcium according to Agatston score and subsequent cardiac risk classification, although risk reclassification may occur in a small subset of subjects.


Assuntos
Algoritmos , Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Medição de Risco
9.
Eur Radiol ; 24(2): 519-26, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24192980

RESUMO

OBJECTIVES: This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). METHODS: cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFVM segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFVA calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. RESULTS: The final EFVA (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). CONCLUSIONS: Automated EFVA quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. KEY POINTS: • Manual epicardial fat volume quantification correlates with risk factors but is time-consuming. • The novel software prototype automates measurement of epicardial fat volume with good accuracy. • This novel approach is less time-consuming and could be incorporated into clinical workflow.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Design de Software
10.
Cancers (Basel) ; 16(8)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38672601

RESUMO

BACKGROUND: The reproducibility of radiomics features extracted from CT and MRI examinations depends on several physiological and technical factors. The aim was to evaluate the impact of contrast agent timing on the stability of radiomics features using dynamic contrast-enhanced perfusion CT (dceCT) or MRI (dceMRI) in prostate and lung cancers. METHODS: Radiomics features were extracted from dceCT or dceMRI images in patients with biopsy-proven peripheral prostate cancer (pzPC) or biopsy-proven non-small cell lung cancer (NSCLC), respectively. Features that showed significant differences between contrast phases were identified using linear mixed models. An L2-penalized logistic regression classifier was used to predict class labels for pzPC and unaffected prostate regions-of-interest (ROIs). RESULTS: Nine pzPC and 28 NSCLC patients, who were imaged with dceCT and/or dceMRI, were included in this study. After normalizing for individual enhancement patterns by defining seven individual phases based on a reference vessel, 19, 467 and 128 out of 1204 CT features showed significant temporal dynamics in healthy prostate parenchyma, prostate tumors and lung tumors, respectively. CT radiomics-based classification accuracy of healthy and tumor ROIs was highly dependent on contrast agent phase. For dceMRI, 899 and 1027 out of 1118 features were significantly dependent on time after contrast agent injection for prostate and lung tumors. CONCLUSIONS: CT and MRI radiomics features in both prostate and lung tumors are significantly affected by interindividual differences in contrast agent dynamics.

11.
Eur Radiol ; 23(5): 1306-15, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23207869

RESUMO

OBJECTIVES: To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reductions. METHODS: Forty neonates and children underwent low radiation CTA with or without ECG synchronisation. Data were reconstructed with FBP, IRIS and SAFIRE. For ECG-synchronised studies, half-dose image acquisitions were simulated. Signal noise was measured and IQ graded. Effective dose (ED) was estimated. RESULTS: Mean absolute and relative image noise with IRIS and full-dose SAFIRE was lower than with FBP (P < 0.001), while SNR and CNR were higher (P < 0.001). Image noise was also lower and SNR and CNR higher in half-dose SAFIRE studies compared with full-and half-dose FBP studies (P < 0.001). IQ scores were higher for IRIS, full-dose SAFIRE and half-dose SAFIRE than for full-dose FBP and higher for half-dose SAFIRE than for half-dose FBP (P < 0.05). Median weight-specific ED was 0.3 mSv without and 1.36 mSv with ECG synchronisation. The estimated ED of half-dose SAFIRE studies was 0.68 mSv. CONCLUSIONS: IR improves image noise, SNR, CNR and subjective IQ compared with FBP in low-radiation-dose paediatric CTA and allows further dose reductions without compromising diagnostic IQ. KEY POINTS: • Iterative reconstruction techniques significantly improve non-invasive cardiovascular CT in children. • Using half traditional radiation dose image quality is higher with iterative reconstruction. • Iterative reconstruction techniques may allow further radiation reductions in paediatric cardiovascular CT.


Assuntos
Doenças Cardiovasculares/congênito , Doenças Cardiovasculares/diagnóstico por imagem , Angiografia Coronária/métodos , Doses de Radiação , Proteção Radiológica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Eur Radiol ; 23(1): 125-32, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22777622

RESUMO

OBJECTIVES: Comparison of coronary artery stent assessment with cardiac CT angiography (cCTA) using traditional filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE), in both full- and half-radiation dose image data. METHODS: Dual-source cCTA studies of 37 implanted stents were reconstructed at full- and half-radiation dose with FBP and SAFIRE. Half-dose data were based on projections from one DSCT detector. In-stent noise, signal-to-noise ratio (SNR), and stent-lumen attenuation increase ratio (SAIR) were measured and image quality graded. Stent volumes were measured to gauge severity of beam hardening artefacts. RESULTS: Full-dose SAFIRE reconstructions were superior to full-dose FBP vis-à-vis in-stent noise (21.2 ± 6.6 vs. 35.7 ± 17.5; P < 0.05), SNR (22.1 ± 8.6 vs. 14.3 ± 6.7; P < 0.05), SAIR (19.6 ± 17.6 vs. 33.4 ± 20.4%; P < 0.05), and image quality (4.2 ± 0.86 vs. 3.5 ± 1.0; P < 0.05). Stent volumes were lower measured with SAFIRE (119.9 ± 53.7 vs. 129.8 ± 65.0 mm(3); P > 0.05). Comparing half-dose SAFIRE with full-dose FBP, in-stent noise (26.7 ± 13.0 vs. 35.7 ± 17.5; P < 0.05) and SNR (18.2 ± 6.9 vs. 14.3 ± 6.7; P < 0.05) improved significantly. SAIR (31.6 ± 24.3 vs. 33.4 ± 20.4%; P > 0.05), stent volume (129.6 ± 57.3 vs. 129.8 ± 65.0 mm(3); P > 0.05), and image quality (3.5 ± 1.0 vs. 3.7 ± 1.1; P > 0.05) did not differ. Radiation dose decreased from 8.7 ± 5.2 to 4.3 ± 2.6 mSv. CONCLUSIONS: Iterative reconstruction significantly improves imaging of coronary artery stents by CT compared with FBP, even with half-radiation-dose data.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Distribuição de Qui-Quadrado , Comorbidade , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Estatísticas não Paramétricas
13.
EClinicalMedicine ; 65: 102267, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37876998

RESUMO

Background: Ultra-low-dose CT (ULDCT) examinations of the chest at only twice the radiation dose of a chest X-ray (CXR) now offer a valuable imaging alternative to CXR. This trial prospectively compares ULDCT and CXR for the detection rate of diagnoses and their clinical relevance in a low-prevalence cohort of non-traumatic emergency department patients. Methods: In this prospective crossover cohort trial, 294 non-traumatic emergency department patients with a clinically indicated CXR were included between May 2nd and November 26th of 2019 (www.clinicaltrials.gov: NCT03922516). All participants received both CXR and ULDCT, and were randomized into two arms with inverse reporting order. The detection rate of CXR was calculated from 'arm CXR' (n = 147; CXR first), and of ULDCT from 'arm ULDCT' (n = 147; ULDCT first). Additional information reported by the second exam in each arm was documented. From all available clinical and imaging data, expert radiologists and emergency physicians built a compound reference standard, including radiologically undetectable diagnoses, and assigned each finding to one of five clinical relevance categories for the respective patient. Findings: Detection rates for main diagnoses by CXR and ULDCT (mean effective dose: 0.22 mSv) were 9.1% (CI [5.2, 15.5]; 11/121) and 20.1% (CI [14.2, 27.7]; 27/134; P = 0.016), respectively. As an additional imaging modality, ULDCT added 9.1% (CI [5.2, 15.5]; 11/121) of main diagnoses to prior CXRs, whereas CXRs did not add a single main diagnosis (0/134; P < 0.001). Notably, ULDCT also offered higher detection rates than CXR for all other clinical relevance categories, including findings clinically irrelevant for the respective emergency department visit with 78.5% (CI [74.0, 82.5]; 278/354) vs. 16.2% (CI [12.7, 20.3]; 58/359) as a primary modality and 68.2% (CI [63.3, 72.8]; 245/359) vs. 2.5% (CI [1.3, 4.7]; 9/354) as an additional imaging modality. Interpretation: In non-traumatic emergency department patients, ULDCT of the chest offered more than twice the detection rate for main diagnoses compared to CXR. Funding: The Department of Biomedical Imaging and Image-guided Therapy of Medical University of Vienna received funding from Siemens Healthineers (Erlangen, Germany) to employ two research assistants for one year.

14.
AJR Am J Roentgenol ; 198(5): W466-74, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528928

RESUMO

OBJECTIVE: The purpose of this article is to review the normal anatomy of the aortic arch and the most common variations of congenital aortic arch anomalies using low-radiation-dose, defined as a dose-length product of 7-15 mGy × cm, MDCT angiography. CONCLUSION: Radiologists should be prepared to fully describe congenital aortic arch anomalies; recognize them on CT angiography, especially the presence or absence of vascular rings or aberrant arteries; and explain their association with the trachea and esophagus.


Assuntos
Angiografia/métodos , Síndromes do Arco Aórtico/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Criança , Pré-Escolar , Humanos , Imageamento Tridimensional , Lactente , Recém-Nascido , Doses de Radiação
15.
AJR Am J Roentgenol ; 199(6): 1402-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23169737

RESUMO

OBJECTIVE: The objective of our study was to evaluate radiation dose and quantitative image quality parameters at high-pitch CT angiography (CTA) of the aorta compared with conventional CTA. MATERIALS AND METHODS: We studied the examinations of 110 patients (65 men and 45 women; mean age ± SD, 64 ± 15 years) who had undergone CTA of the entire aorta on a second-generation dual-source CT system; 50 examinations were performed in high-pitch mode. The mean arterial attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) were calculated for the high-pitch CTA and conventional CTA groups. Radiation exposures were compared. RESULTS: All studies were considered of diagnostic quality. At high-pitch CTA, the mean tube voltage and tube current-exposure time product were 118 ± 7 kV (SD) and 197 ± 78 mAs compared with 120 ± 1 kV and 258 ± 78 mAs, respectively, at conventional CTA (p < 0.05). The mean volume CT dose index, dose-length product, and effective dose were 8.1 ± 2.4 mGy, 561.1 ± 178.6 mGy × cm, and 9.6 ± 3.0 mSv at high-pitch CTA and 18.3 ± 7.7 mGy, 1162.6 ± 480.1 mGy × cm, and 19.8 ± 8.2 mSv at conventional CTA (p < 0.001). Attenuation was similar for both protocols, whereas significantly less contrast medium was injected for high-pitch CTA than for standard-pitch CTA (87.3 ± 16 mL vs 97.9 ± 16 mL, respectively; p < 0.01). The SNR and CNR were significantly lower in the high-pitch CTA examinations (p < 0.01), whereas the FOM was nonsignificantly higher. Twenty patients underwent both high-pitch CTA and conventional CTA, with a 45% reduction in radiation dose (p < 0.001). CONCLUSION: High-pitch CTA of the aorta yields 45-50% reduction of radiation exposure as well as contrast medium savings with maintained vessel attenuation.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Angiografia Digital , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Humanos , Iohexol , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Razão Sinal-Ruído
16.
AJR Am J Roentgenol ; 198(4): 939-45, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22451564

RESUMO

OBJECTIVE: The purpose of this article is to assess aortic root and iliofemoral vessel anatomy and the frequency of clinically significant incidental findings on aortoiliac CT angiography (CTA) performed for planning of transcutaneous aortic valve implantation. MATERIALS AND METHODS: Aortoiliac CTA studies of 207 patients scheduled for transcutaneous aortic valve implantation were analyzed. Anatomic dimensions relevant to the interventional procedure, including diameter of the aortic annulus and sinus of Valsalva, distance between aortic annulus and coronary ostia, coronary leaflet length, left ventricular outflow tract diameter, and vessel diameter of iliac arteries, were analyzed. Clinically significant incidental findings were recorded. RESULTS: The mean (± SD) maximum and minimum diameters of the aortic annulus were 29 ± 3.9 mm and 23.5 ± 4.1 mm, respectively. The mean distances between aortic annulus and the ostium of the left and right coronary artery were 13.5 ± 3.2 mm and 14.8 ± 3.9 mm, respectively. The mean maximum and minimum diameters of the left ventricular outflow tract were 27 ± 4 mm and 1.9 ± 4 mm, respectively. The mean diameter of the sinus of Valsalva was 33.4 ± 5.1 mm. The mean diameters of the right and left external iliac artery were 8 ± 1 and 8 ± 2 mm, respectively. Almost half the patients (101/207) had clinically significant incidental findings, including noncalcified pulmonary nodules larger than 8 mm (n = 7), pulmonary embolism (n = 3), or aortic aneurysm (n = 12). CONCLUSION: Aortoiliac CTA provides relevant information on aortic root and iliofemoral vessel anatomy for preinterventional planning. CTA reveals clinically significant incidental findings in a high number of patients considered for transcutaneous aortic valve implantation, which may have a significant impact on patient selection.


Assuntos
Angiografia/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Artéria Ilíaca/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Aortografia , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Masculino , Planejamento de Assistência ao Paciente , Cuidados Pré-Operatórios , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
17.
In Vivo ; 36(3): 1354-1359, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35478124

RESUMO

BACKGROUND/AIM: Various neurological disorders are associated with lesions predominantly or exclusively affecting the splenium of the corpus callosum (CC), such as Marchiafava-Bignami syndrome (MBS), reversible splenium lesion (RSL), and ischemic stroke (IS). The spectrum of symptoms is broad and clinical presentations may be indistinguishable. Therefore, we aimed to investigate the additional value of diffusion-weighted imaging (DWI) findings of splenial lesions in patients with MBS, RSL, and IS. PATIENTS AND METHODS: Overall, 23 patients (4 patients with MBS, 10 patients with RSL, and 9 patients with isolated IS in the splenium) were identified from a magnetic resonance imaging report database and analyzed with focus on lesion localization, shape, and size on DWI, as well as relative apparent diffusion coefficient (ADC). RESULTS: A focal hyperintensity in the splenium was observed on DWI in all patients. In MBS symmetrical boomerang-shaped lesions, in RSL central oval or round lesions, and in IS eccentric irregular lesions in the splenium were found. The median lesion size in MBS [6.25 (IQR=2.04-8.62) ml] was significantly larger than that in RSL [0.38 (IQR=0.09-0.92) ml, p=0.01], and in IS [0.09 (IQR=0.05-0.94) ml; p=0.01]. Regarding relative ADC values, no significant differences between MBS [0.32 (IQR=0.19-0.62)], RSL [0.22 (IQR=0.14-0.30)], and IS [0.27 (IQR=0.20-1.19)] were found. CONCLUSION: Diffusion restricted lesions in the splenium of the CC are best classified by localization, shape, and size, whereas relative ADC values are of limited value for differentiation of different neurological disorders.


Assuntos
Encefalopatias , Corpo Caloso , Encefalopatias/patologia , Corpo Caloso/diagnóstico por imagem , Corpo Caloso/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Humanos
18.
JTCVS Open ; 10: 62-72, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36004247

RESUMO

Objectives: The ratio of pulmonary artery (PA) and ascending aorta (AA) diameters has recently been shown to be a useful indicator for disease severity and predictor of outcome in patients with pulmonary hypertension and heart failure. This study aimed at evaluating the applicability of this ratio for perioperative risk assessment of patients with chronic thromboembolic pulmonary hypertension undergoing pulmonary endarterectomy. Methods: In this retrospective cohort study on 149 patients undergoing pulmonary endarterectomy between 2013 and 2020, the preoperative PA to AA ratio was analyzed on axial computed tomography. Variables of pulmonary hemodynamic status were assessed during preoperative right heart catheterization and postoperative Swan-Ganz catheter measurements. Perioperative survival was analyzed by Kaplan-Meier method and log-rank tests. Results: Preoperative computed tomography measurements showed a median AA diameter of 31 mm (range, 19-47 mm), and a median PA diameter of 36 mm (range, 25-55 mm). The calculated median PA to AA ratio was 1.13 (range, 0.79-1.80). PA to AA ratio correlated positively with PA pressure (systolic, r = 0.352 [P < .001]; diastolic, r = 0.406 [P < .001]; mean, r = 0.318 [P < .001]) and inversely with age (r = -0.484 [P < .001]). Univariable Cox regression analysis identified PA diameter (P = .008) as a preoperative parameter predictive of survival. There was a significant difference (log-rank P = .037) in 30-day survival probability for patients with lower PA to AA ratios (<1.136; survival probability, 97.4%) compared with patients with higher ratios (>1.136; survival probability, 88.9%). Conclusions: PA to AA ratio shows a correlation with other variables associated with pulmonary hypertension. In addition, patients with higher PA to AA ratios have lower survival probabilities after PEA. Further analysis of PA to AA ratio on the selection of chronic thromboembolic pulmonary hypertension for different treatment modalities-pulmonary endarterectomy, medical therapy, and or balloon pulmonary angioplasty-is warranted.

19.
Clin Neuroradiol ; 31(3): 827-831, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32865598

RESUMO

PURPOSE: Occlusion or significant stenosis of the internal carotid artery (ICA) in the cervical segment is commonly associated with a poststenotic decrease in the downstream blood flow and perfusion. Fluid attenuated inversion recovery (FLAIR) vascular hyperintensities (FVH) are a phenomenon that represents slow arterial blood flow. In this study, we investigated the frequency and extent of FVH in the distal ICA in patients with proximal ICA stenosis. METHODS: We analyzed the magnetic resonance imaging (MRI) findings in 51 patients with a total of 60 cervical ICA stenoses with special focus on the frequency and extent of FVH in the area of the petrous segment of the ICA on FLAIR images and correlated these with Doppler/duplex sonography results. RESULTS: In 46 (76.7%) patients with ICA stenosis, FVH could be detected in the petrous segment of the ICA: in 19 (41.3%) patients a thin hyperintense rim near the vessel wall (grade 1), in 24 (52.2%) patients a strong hyperintense rim near the vessel wall (grade 2), and in 3 (6.5%) patients a hyperintense filling of the entire lumen (grade 3) was observed. The extent of FVH in the ICA in the petrous segment showed a high negative correlation with the poststenotic flow velocity (Spearman correlation, R = -0.75, p < 0.001), and moderate correlation with the degree of ICA stenosis (Spearman correlation, R = 0.51, p< 0.001). CONCLUSION: An FVH in the petrous ICA is commonly seen among patients with steno-occlusive disease in proximal ICA and could therefore be useful to recognize a proximal ICA stenosis even on FLAIR images.


Assuntos
Estenose das Carótidas , Angiografia por Ressonância Magnética , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética
20.
Front Oncol ; 11: 637804, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33889546

RESUMO

Background: Immune checkpoint inhibitor efficacy in advanced cancer patients remains difficult to predict. Imaging is the only technique available that can non-invasively provide whole body information of a patient's response to treatment. We hypothesize that quantitative whole-body prognostic information can be extracted by leveraging artificial intelligence (AI) for treatment monitoring, superior and complementary to the current response evaluation methods. Methods: To test this, a cohort of 74 stage-IV urothelial cancer patients (37 in the discovery set, 37 in the independent test, 1087 CTs), who received anti-PD1 or anti-PDL1 were retrospectively collected. We designed an AI system [named prognostic AI-monitor (PAM)] able to identify morphological changes in chest and abdominal CT scans acquired during follow-up, and link them to survival. Results: Our findings showed significant performance of PAM in the independent test set to predict 1-year overall survival from the date of image acquisition, with an average area under the curve (AUC) of 0.73 (p < 0.001) for abdominal imaging, and 0.67 AUC (p < 0.001) for chest imaging. Subanalysis revealed higher accuracy of abdominal imaging around and in the first 6 months of treatment, reaching an AUC of 0.82 (p < 0.001). Similar accuracy was found by chest imaging, 5-11 months after start of treatment. Univariate comparison with current monitoring methods (laboratory results and radiological assessments) revealed higher or similar prognostic performance. In multivariate analysis, PAM remained significant against all other methods (p < 0.001), suggesting its complementary value in current clinical settings. Conclusions: Our study demonstrates that a comprehensive AI-based method such as PAM, can provide prognostic information in advanced urothelial cancer patients receiving immunotherapy, leveraging morphological changes not only in tumor lesions, but also tumor spread, and side-effects. Further investigations should focus beyond anatomical imaging. Prospective studies are warranted to test and validate our findings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA