Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 103(3): 417-424, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38297989

RESUMO

BACKGROUND: Optimal stent deployment in left main (LM) bifurcation is paramount, and incomplete stent apposition may cause major adverse cardiac events (MACE). Bench studies show that the proximal optimization technique (POT) provides the best stent apposition. AIMS: We aimed to investigate the impact of POT on clinical outcomes in patients treated for unprotected LM (ULM) disease at our institution. METHODS: We identified 162 patients who underwent percutaneous coronary intervention (PCI) for ULM coronary disease in the Cardio-FR database. Out of these, 99 (61%) had undergone POT, while 63 patients were treated without POT. The primary outcome was the bifurcation-oriented composite endpoint (BOCE) of cardiac death, target-bifurcation myocardial infarction and target-bifurcation revascularization at maximal follow-up. RESULTS: Mean age was 76 years, and 69% presented with acute coronary syndrome. Mean follow-up was 2.25 years (822 days). The BOCE occurred in 43 (27%) of which 20 (20%) in the POT group and 23 (37%) in the no-POT group (p = 0.009). Cardiac death occurred in 15 (15%) patients in the POT- and 17 (27%) in no-POT group (p = 0.26). Target bifurcation revascularization occurred in 4 (4%) patients in the POT- and 6 (10%) patients in the no-POT group (p = 0.19). POT In the multivariate analysis, POT was the strongest parameter and was associated with BOCE, cardiac death, occurrence of any revascularization and all-cause mortality. CONCLUSION: The POT improves clinical outcomes. These findings strongly support the systematic use of POT in patients undergoing ULM-PCI.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Resultado do Tratamento , Morte , Angiografia Coronária , Fatores de Risco
2.
Front Cardiovasc Med ; 11: 1384222, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38911518

RESUMO

Introduction: Intravascular imaging, especially optical coherence tomography (OCT), has significantly improved percutaneous coronary intervention (PCI), yet its routine clinical application faces challenges. This case series introduces the Gentuity® High-Frequency Optical Coherence Tomography (HF-OCT), a novel device designed to enhance intracoronary imaging with a significantly faster pullback and smaller catheter size, potentially offering enhanced navigability in complex lesions. We aimed to assess the image quality of Gentuity® HF-OCT in complex vessel conditions, as well as presenting a case series to illustrate the application of the device in various clinical scenarios. Methods: In this case series, we included all patients who underwent intracoronary HF-OCT imaging at our center. The primary endpoint was image quality assessed by clear image length (CIL). Image quality was assessed in relation to (1) lesion severity assessed by minimum lumen area (MLA); (2) vessel size, differentiating between larger (diameter ≥ 4 mm) and smaller vessel segments; (3) pre- vs. post-PCI conditions, and (4) vessel tortuosity, categorized into none, moderate, and severe. Results: Twenty-four HF-OCT runs from 14 patients were included. No significant differences in CIL were observed across lesion severity terciles (p = 0.449), between small and large vessel segments [mean CIL% difference 1.3%; confidence interval (CI), -9.3 to 11.8; p = 0.802], and pre- vs. post-PCI conditions (mean CIL difference -3.9 mm; CI, -14.0 to 6.1; p = 0.373). Vessel tortuosity significantly impacted image quality, with clear reductions in CIL observed in cases of moderate (74.8; CI, 73.5 to 76.0; vs. 63.9; CI, 56.2 to 71.5; p = 0.043) and severe tortuosity (74.8; CI, 73.5 to 76.0; vs. 65.0; CI, 62.1 to 67.9; p = 0.002) compared to vessels with no tortuosity. Overall, the HF-OCT demonstrated excellent catheter deliverability and crossability, with very satisfactory image quality and no significant adverse events. Conclusion: The Gentuity® HF-OCT is a new OCT device capable of navigating both small- and large-diameter vessels, with similar image quality, but vessel tortuosity seems to have an impact on image quality. It appears to be as usable as conventional OCT for pre-PCI diagnosis and OCT-guided PCI, potentially bringing additional benefits in terms of deliverability, lesion crossover and ease of use in routine clinical practice.

3.
Tex Heart Inst J ; 51(2)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38982874

RESUMO

BACKGROUND: Various scoring systems have been developed to assess the risk of bleeding in medical settings. HAS-BLED and HEMORR2HAGES risk scores are commonly used to estimate bleeding risk in patients receiving anticoagulation for atrial fibrillation, but data on their predictive value in patients undergoing percutaneous coronary intervention (PCI) are limited. METHODS: This study evaluated and compared the predictive abilities of the HAS-BLED and HEMORR2HAGES bleeding risk scores in all-comer patients undergoing PCI. The PARIS score, specifically designed for patients undergoing PCI, was used as a comparator. The scores were calculated at baseline and compared with the occurrence of events during a 2-year clinical follow-up period. Between 2015 and 2017, all consecutive patients undergoing PCI we re prospectively enrolled and divided into risk tertiles based on bleeding risk scores. The primary end points were hierarchical major bleeding events, defined by Bleeding Academic Research Consortium types 3 through 5, and patient-oriented composite end points according to Bleeding Academic Research Consortium classification, which were assessed during the 2-year follow-up period. RESULTS: A total of 1,080 patients completed the follow-up period. Two years after index, 189 patients (17.5%) had experienced any bleeding, with 48 events (4.4%) classified as Bleeding Academic Research Consortium types 3 to 5. All bleeding risk scores showed statistically significant predictive ability for bleeding events. The HEMORR2HAGES score (C statistic, 0.73) was more effective than the HAS-BLED score (C statistic, 0.66; P = .07) and the PARIS score (C statistic, 0.66; P = .06) in predicting risk of major bleeding. Patients in high-risk bleeding groups also experienced a higher incidence of patient-oriented composite end points. CONCLUSIONS: The HEMORR2HAGES, HAS-BLED, and PARIS risk scores exhibited good predictive abilities for bleeding events following PCI. Patients at high risk of bleeding also demonstrated increased ischemic risk and higher mortality during the 2-year follow-up period.


Assuntos
Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Masculino , Feminino , Medição de Risco/métodos , Fatores de Risco , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Seguimentos , Incidência , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/diagnóstico , Fatores de Tempo , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA