Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38736245

RESUMO

BACKGROUND: Malnutrition is associated with poor prognosis in several cardiovascular diseases; however, its role in patients with secondary mitral regurgitation (SMR) is poorly known. AIMS: To evaluate the impact of nutritional status, assessed using different scores, on clinical outcomes in patients with SMR undergoing transcatheter edge-to-edge repair (TEER) in a real-world setting. METHODS: A total of 658 patients with SMR and complete nutritional data were identified from the MIVNUT registry. Nutritional status has been assessed using controlling nutritional status index (CONUT), prognostic nutritional index (PNI), and geriatric nutritional risk index (GNRI) scores. Outcomes of interest were all-cause mortality and all-cause mortality or heart failure (HF) hospitalization. RESULTS: Any malnutrition grade was observed in 79.4%, 16.7%, and 47.9% of patients by using CONUT, PNI, and GNRI, respectively, while moderate to severe malnutrition was noted in 24.7%, 16.7%, and 25.6% of patients, respectively. At a median follow-up of 2.2 years, 212 patients (32.2%) died. Moderate-severe malnutrition was associated with a higher rate of all-cause mortality (HR: 2.46 [95% CI: 1.69-3.58], HR: 2.18 [95% CI: 1.46-3.26], HR: 1.97 [95% CI: 1.41-2.74] for CONUT, PNI, and GNRI scores, respectively). The combined secondary endpoint of all-cause mortality and HF rehospitalization occurred in 306 patients (46.5%). Patients with moderate-severe malnutrition had a higher risk of the composite endpoint (HR: 1.56 [95% CI: 1.20-2.28], HR: 1.55 [95% CI: 1.01-2.19], HR: 1.36 [95% CI: 1.02-1.80] for CONUT, PNI, and GNRI scores, respectively). After adjustment for multiple confounders, moderate-severe malnutrition remained independently associated with clinical outcomes. CONCLUSIONS: Moderate-severe malnutrition was common in patients with SMR undergoing TEER. It was independently associated with poor prognosis regardless of the different scores used.

2.
Eur Heart J ; 43(7): 641-650, 2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-34463727

RESUMO

AIMS: Severe mitral regurgitation (MR) following acute myocardial infarction (MI) is associated with high mortality rates and has inconclusive recommendations in clinical guidelines. We aimed to report the international experience of patients with secondary MR following acute MI and compare the outcomes of those treated conservatively, surgically, and percutaneously. METHODS AND RESULTS: Retrospective international registry of consecutive patients with at least moderate-to-severe MR following MI treated in 21 centres in North America, Europe, and the Middle East. The registry included patients treated conservatively and those having surgical mitral valve repair or replacement (SMVR) or percutaneous mitral valve repair (PMVR) using edge-to-edge repair. The primary endpoint was in-hospital mortality. A total of 471 patients were included (43% female, age 73 ± 11 years): 205 underwent interventions, of whom 106 were SMVR and 99 PMVR. Patients who underwent mitral valve intervention were in a worse clinical state (Killip class ≥3 in 60% vs. 43%, P < 0.01), but yet had lower in-hospital and 1-year mortality compared with those treated conservatively [11% vs. 27%, P < 0.01 and 16% vs. 35%, P < 0.01; adjusted hazard ratio (HR) 0.28, 95% confidence interval (CI) 0.18-0.46, P < 0.01]. Surgical mitral valve repair or replacement was performed earlier than PMVR [median of 12 days from MI date (interquartile range 5-19) vs. 19 days (10-40), P < 0.01]. The immediate procedural success did not differ between SMVR and PMVR (92% vs. 93%, P = 0.53). However, in-hospital and 1-year mortality rates were significantly higher in SMVR than in PMVR (16% vs. 6%, P = 0.03 and 31% vs. 17%, P = 0.04; adjusted HR 3.75, 95% CI 1.55-9.07, P < 0.01). CONCLUSIONS: Early intervention may mitigate the poor prognosis associated with conservative therapy in patients with post-MI MR. Percutaneous mitral valve repair can serve as an alternative for surgery in reducing MR for high-risk patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 99(5): 1619-1625, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35043543

RESUMO

BACKGROUND AND OBJECTIVES: Evidence regarding redo percutaneous interventions for recurrent mitral regurgitation is scarce. We ought to evaluate procedural and clinical outcomes of repeated edge-to-edge transcatheter mitral valve repair (TMVR) interventions. METHODS: This multicenter study collected individual data from eight high-volume TMVR Centers in Spain. Between 2012 and 2020, all patients undergoing a second edge-to-edge TMVR intervention (Redo) were included in the study. RESULTS: Among a total of 1028 procedures, 31 patients (3%) with residual MR ≥ 3 at follow-up underwent a second procedure (Redo). Redo intervention was mainly conducted between the first and second year after the first procedure. The most common cause of MR progression was partial detachment (46.7%) followed by LV remodeling (35.5%). Procedural success was achieved in 87% of cases. After a mean follow-up of 1.75 ± 1.54 years, all-cause and cardiovascular mortality were 48.1% and 25%, respectively. Nearly half of the patients (48.1%) required at least one hospital admission for CHF within the follow-up period. However, most of the patients presented symptomatic improvement as depicted by an NYHA class ≤2. Elective mitral surgery was conducted in only one patient at follow-up due to insufficient MR reduction. CONCLUSIONS: According to our findings, redo edge-to-edge TMVR interventions were feasible and safe with a high procedural success rate. Clinical and echocardiographic follow-up showed however modest long-term results in this specific setting.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 97(7): E1025-E1032, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33580751

RESUMO

OBJECTIVES: To describe imaging assessment, procedural and follow-up outcome of patients undergoing left atrial appendage (LAA) occlusion (LAAO) using a "sandwich" technique. BACKGROUND: The presence of a LAA with chicken wing morphology constitutes a challenge that sometimes requires specific occlusion strategies like the "sandwich" technique. However, procedural and follow-up data focusing on this implanting strategy is scarce. METHODS: This multicenter study collected individual data from eight centers between 2012 and 2019. Consecutive patients with chicken-wing LAAs defined as an early (<20 mm from the ostium) and severe bend (>90°) who underwent LAAO with Amplatzer devices and using the "sandwich" technique were included in the analysis. RESULTS: Overall, 190 subjects were enrolled in the study. Procedures were done with the Amulet device (85%) and the Amplatzer Cardiac Plug (15%). Successful implantation was achieved in 99.5% with ≤1 partial recapture in 80% of cases. Single (46.2%) and dual antiplatelet therapy (39.4%) were the most used antithrombotic therapies after LAAO. In-hospital major adverse events rate was 1.5% with no deaths. One patient (0.5%) had cardiac tamponade requiring percutaneous drainage. With a mean follow-up of 19.6 ± 14.8 months, the mortality and stroke rates were 7.7%/year and 2.5%/year, respectively. Follow-up transesophageal echocardiography (TEE) at 2-3 months showed device-related thrombosis in 2.8% and peri-device leak ≥3 mm in 1.2% of patients. CONCLUSIONS: In a large series of patients with chicken wing LAA anatomies undergoing LAAO, the use of the "sandwich" technique was feasible and safe. Preprocedural imaging was a key-factor to determine specific measurements.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 97(6): 1259-1267, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33600072

RESUMO

OBJECTIVES: To assess outcomes in patients with acute mitral regurgitation (MR) following acute myocardial infarction (AMI) who received percutaneous mitral valve repair (PMVR) with the MitraClip device and to compare outcomes of patients who developed cardiogenic shock (CS) to those who did not (non-CS). BACKGROUND: Acute MR after AMI may lead to CS and is associated with high mortality. METHODS: This registry analyzed patients with MR after AMI who were treated with MitraClip at 18 centers within eight countries between January 2016 and February 2020. Patients were stratified into CS and non-CS groups. Primary outcomes were mortality and rehospitalization due to heart failure. Secondary outcomes were acute procedural success, functional improvement, and MR reduction. Multivariable Cox regression analysis evaluated association of CS with clinical outcomes. RESULTS: Among 93 patients analyzed (age 70.3 ± 10.2 years), 50 patients (53.8%) experienced CS before PMVR. Mortality at 30 days (10% CS vs. 2.3% non-CS; p = .212) did not differ between groups. After median follow-up of 7 months (IQR 2.5-17 months), the combined event mortality/re-hospitalization was similar (28% CS vs. 25.6% non-CS; p = .793). Likewise, immediate procedural success (90% CS vs. 93% non-CS; p = .793) and need for reintervention (CS 6% vs. non-CS 2.3%, p = .621) or re-admission due to HF (CS 13% vs. NCS 23%, p = .253) at 3 months did not differ. CS was not independently associated with the combined end-point (hazard ratio 1.1; 95% CI, 0.3-4.6; p = .889). CONCLUSIONS: Patients found to have significant MR during their index hospitalization for AMI had similar clinical outcomes with PMVR whether they presented in or out of cardiogenic shock, provided initial hemodynamic stabilization was first achieved before PMVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Infarto do Miocárdio , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Sistema de Registros , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 44(7): 1216-1223, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34110038

RESUMO

BACKGROUND: Gastrointestinal bleeding (GIB) is associated with a high recurrence rate and a prior GIB episode is common in real-world left atrial appendage closure (LAAC) recipients. The present study sought to evaluate the clinical characteristics and outcomes of patients with prior GIB undergoing LAAC, and to determine the factors associated with and clinical impact of GIB recurrence. METHODS: Multicenter study including 277 consecutive patients who underwent percutaneous LAAC and had prior GIB. All-cause death, all bleeding, GIB recurrence, and clinical ischemic stroke were recorded. RESULTS: After a median follow-up of 17 (interquartile range: 6-37) months post-LAAC, the rates of death, bleeding, GIB recurrence, and ischemic stroke were 14.0 per 100 person-year (PY), 29.3 per 100 PY, 17.7 per 100 PY, and 1.1 per 100 PY, respectively. GIB recurrence occurred within 3 months post-LAAC in 55.8% of patients. A previous lower GIB (vs. upper or unclassified) (HR: 1.76; 95% CI: 1.09-2.82; p = .020) and eGFR < 45 mL/min (HR: 1.70; 95% CI:1.04-2.67; p = .033) determined an increased risk of GIB recurrence. By multivariable analysis, eGFR < 45 mL/min (HR: 2.72; 95% CI: 1.70-4.34; p < .001), GIB recurrence following LAAC (HR: 2.15; 95% CI: 1.33-3.46; p = .002), diabetes mellitus (HR: 1.77; 95% CI: 1.10-2.84; p = .018), and age (HR: 1.06; 95% CI: 1.03-1.10; p < .001) were associated with an increased mortality. CONCLUSIONS: Patients with prior GIB undergoing LAAC exhibited a relatively low rate of GIB recurrence, and prior lower GIB and moderate-to-severe chronic kidney disease determined an increased risk. GIB recurrence was associated with an increased mortality.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Hemorragia Gastrointestinal/complicações , Hemorragia Gastrointestinal/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Recidiva , Resultado do Tratamento
7.
J Heart Valve Dis ; 26(2): 169-174, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28820546

RESUMO

BACKGROUND: Atrial fibrillation is present in 30-50% of patients undergoing percutaneous mitral valve repair. The presence of a formal contraindication to oral anticoagulation is also very common in these patients. In this context, percutaneous left atrial appendage occlusion (LAAO) may be a valid alternative for these patients. The study aim was to assess the feasibility, safety, and technical considerations of the combination of percutaneous mitral valve repair using the MitraClip system and LAAO. The present study describes the multicenter experience of combined MitraClip and LAAO procedures. METHODS: Between April 2012 and April 2016, six patients were successfully treated with the combined procedure. RESULTS: In all patients, mitral valve repair was performed before LAAO. Both procedures were successfully performed in all cases without any relevant procedural complication or mortality. CONCLUSIONS: According to the results of the present study, a combination of both techniques appears to be feasible and safe, with favorable in-hospital outcomes.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/terapia , Valva Mitral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Fatores de Risco , Índice de Gravidade de Doença , Espanha , Fatores de Tempo , Resultado do Tratamento
9.
Expert Rev Med Devices ; 21(3): 187-196, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38155555

RESUMO

INTRODUCTION: Over the last two decades, mitral transcatheter edge-to-edge repair (M-TEER) has become a safe and effective therapy for severe mitral regurgitation in patients deemed at high surgical risk. AREAS COVERED: This review aims to encompass the most relevant and updated evidence in the field of M-TEER from its inception, focusing on clinical and anatomical features for proper patient and device selection. EXPERT OPINION: Growing operator experience and device iterations have resulted in improved clinical outcomes and an expansion of the therapy to patients with complex anatomies and clinical scenarios. Future investigations are warranted to determine the best management options and the most suitable device for every patient with MR.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seleção de Pacientes , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-39023452

RESUMO

BACKGROUND: Patients treated with left atrial appendage occlusion (LAAO) are at high bleeding risk. Intensive antithrombotic treatment is recommended after the procedure to prevent device-related thrombosis. OBJECTIVES: This study sought to evaluate the incidence, consequences, and predictors of early nonprocedural bleeding after LAAO. METHODS: This was a multicenter study including 1,649 patients undergoing LAAO in 9 centers. Early nonprocedural bleeding was defined as bleeding unrelated to the procedure occurring within 3 months after device implantation. The severity of bleeding was defined by the Valve Academic Research Consortium-2 classification. A sensitivity analysis was performed at 45 days. RESULTS: A total of 121 (7.3%) patients experienced early nonprocedural bleeding events, and 69 (57.0%) were classified as major bleeding (4.2% of patients). Independent predictors of early nonprocedural bleeding were dual antiplatelet therapy (DAPT) at discharge (adjusted HR [aHR]: 1.61; 95% CI: 1.12-2.33; P = 0.01), prior gastrointestinal bleeding (aHR: 2.15; 95% CI: 1.38-3.35; P < 0.001), and multiple locations of prior bleeding (aHR: 2.33; 95% CI: 1.34-4.05; P < 0.001). DAPT at discharge was predictive of both all and major nonprocedural bleeding at 3 months and 45 days. After a median follow-up of 2.3 years (Q1-Q3: 1.1-4.1 years), early nonprocedural bleeding was independently associated with an increased risk of all-cause death (aHR: 1.53; 95% CI: 1.15-2.06; P < 0.001). This heightened mortality risk was similar at 45 days. CONCLUSIONS: Early nonprocedural bleeding after LAAO occurred in ∼7% of patients within 3 months, with more than one-half being classified as major bleeding. Regardless of severity, early nonprocedural bleeding was associated with increased mortality. DAPT at discharge determined an increased risk of early nonprocedural bleeding after LAAO. These results emphasize the importance of bleeding risk for determining antithrombotic strategies after LAAO.

11.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629416

RESUMO

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Ventrículos do Coração , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Clínicos como Assunto
12.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38763211

RESUMO

INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.

13.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38795093

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Assuntos
Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Contraindicações de Medicamentos , AVC Isquêmico , Sistema de Registros , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/mortalidade , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Feminino , Masculino , Anticoagulantes/efeitos adversos , Anticoagulantes/administração & dosagem , Idoso , Fatores de Risco , Medição de Risco , Idoso de 80 Anos ou mais , Fatores de Tempo , Administração Oral , AVC Isquêmico/prevenção & controle , AVC Isquêmico/mortalidade , AVC Isquêmico/diagnóstico , AVC Isquêmico/etiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Falha de Tratamento , Hemorragia/induzido quimicamente , Recidiva , Pessoa de Meia-Idade , Estudos Retrospectivos , Europa (Continente)
14.
Catheter Cardiovasc Interv ; 82(6): E831-4, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-23729270

RESUMO

We present a case report of an 80-year-old frail woman with hemolytic anemia and cardiac failure secondary to mitral severe paravalvular regurgitation. Her clinical history was significant for mitral valve replacement that was complicated with a paravalvular leak two months after surgery. The leak was closed percutaneously with an Amplatzer Vascular Plug III single device. A year later she is readmitted with heart failure and the transesophageal echocardiogram revealed a severe paravalvular leak beside the Vascular Plug III device that seemed to be dislodged and rocking. During a new attempt of percutaneous leak closure, while trying to lasso the old device, it embolized to the iliac bifurcation. The old device could be removed from the right femoral artery and the leak could be closed with two new Vascular Plug III devices deployed simultaneously. To our knowledge this is the first reported case of a late embolization of a Vascular Plug III device.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Embolia/etiologia , Migração de Corpo Estranho/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/terapia , Valva Mitral/cirurgia , Idoso de 80 Anos ou mais , Anemia Hemolítica/diagnóstico , Anemia Hemolítica/etiologia , Remoção de Dispositivo , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Embolia/diagnóstico , Embolia/terapia , Desenho de Equipamento , Feminino , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/terapia , Idoso Fragilizado , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Fatores de Tempo , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 82(2): 193-200, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21805615

RESUMO

AIM: Thrombosis of stents and of saphenous vein grafts (SVG) remains a severe complication of either revascularization techniques that often are present as ST elevation myocardial infarction (STEMI). The aim of this longitudinal cohort study was to compare the 1-year clinical outcomes among STEMI patients requiring primary PCI due to stent thrombosis and graft occlusion presenting with STEMI. METHODS AND RESULTS: We prospectively collected data on all patients undergoing primary PCI at the Montreal Heart Institute between April 1, 2007 and March 30, 2008. Study patients were grouped according to the etiology of the STEMI: stent thrombosis, graft thrombosis, or atherosclerosis-related STEMIs (control group). The primary combined end-point, major adverse cardiac events (MACE), was defined as death, myocardial infarction, and target vessel revascularization within 12 months as primary end point. Of the 489 STEMI patients included in the study, 23 were due to stent thrombosis, 22 to graft thrombosis, and 444 in the control group. Stent and graft thromboses were associated with a higher MACE rates, 26.1 and 22.7%, respectively, compared to the control group, 9.3% (P = 0.004). Moreover, only stent thrombosis was associated with an increased risk of MACE (HR 2.57, confidence interval 95% 1.08-6.08. CONCLUSION: Patients with stent thrombosis present with higher rate of reinfarction while graft thrombosis is associated with an increase in 1-year cardiac mortality. Using multivariate analysis, higher MACE rates were associated with stent thrombosis as compared to graft thrombosis.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Trombose Coronária/etiologia , Oclusão de Enxerto Vascular/etiologia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Veia Safena/transplante , Stents , Trombose Venosa/etiologia , Idoso , Distribuição de Qui-Quadrado , Ponte de Artéria Coronária/mortalidade , Trombose Coronária/mortalidade , Trombose Coronária/fisiopatologia , Trombose Coronária/terapia , Feminino , Oclusão de Enxerto Vascular/mortalidade , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/terapia , Humanos , Estimativa de Kaplan-Meier , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Quebeque , Recidiva , Sistema de Registros , Fatores de Risco , Veia Safena/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Trombose Venosa/mortalidade , Trombose Venosa/fisiopatologia , Trombose Venosa/terapia
16.
Card Electrophysiol Clin ; 15(2): 193-200, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37076231

RESUMO

Left atrial appendage closure aims to eliminate the stasis component of Virchow triad by eliminating a cul-de-sac that favors thrombosis, particularly when atrial contractility becomes inefficient, such as in atrial fibrillation. Left atrial appendage closure devices have a common objective of sealing the appendage completely, with device stability and avoidance of device thrombosis. Two main device designs have been used to perform left atrial appendage closure: those that use a pacifier design (lobe + disk) and those that use a plug (single lobe) design. This review highlights the potential features and benefits of the single-lobe devices.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Seguimentos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Fibrilação Atrial/cirurgia , Trombose/prevenção & controle , Cateterismo Cardíaco
17.
JACC Cardiovasc Interv ; 16(6): 643-651, 2023 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-36764917

RESUMO

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used to guide left atrial appendage closure (LAAC). OBJECTIVES: The aim of this study was to investigate the efficacy and safety of ICE-guided LAAC with the Watchman FLX device. METHODS: The ICE LAA (I Can See Left Atrial Appendage) study was a prospective, multicenter study with independent adjudication of echocardiographic data by a core laboratory and clinical events by a clinical events committee. Patients with atrial fibrillation with CHA2DS2-VASc scores ≥2 and clinical indications for LAAC were eligible. Preplanning with either cardiac computed tomography or transesophageal echocardiography (TEE) within 7 days prior to LAAC was mandatory. Intraprocedural ICE was carried out from the left atrium. The primary outcome was the rate of significant peridevice leaks (>5 mm) at 45-day TEE. RESULTS: A total of 100 patients were enrolled. The mean age was 76 ± 8 years, the mean CHA2DS2-VASc score was 4.0 ± 1.5, and the mean HAS-BLED score was 2.5 ± 0.9. The incidence of the primary outcome of significant peridevice leak (>5 mm) was 0%; all patients evaluated by TEE at 45 days had effective LAAC. All patients received Watchman FLX devices, and technical success was 100%. The number of devices per case was 1.0 ± 0.1. ICE successfully guided the assessment of device release criteria, including device compression (19.2% ± 7.1%; recommended range: 10%-30%). No subject required conversion to TEE. Procedural complications were 4 access-site bleeds. There was no stroke, transient ischemic attack, systemic embolization, pericardial effusion, device embolization, or device-related thrombus during the procedure or 45-day follow-up. CONCLUSIONS: ICE can be used to successfully guide LAAC with the Watchman FLX, with excellent procedural success, a high rate of effective LAAC, and minimal periprocedural complications. (I Can See Left Atrial Appendage [ICELAA] Clinical Study; NCT04196335).


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cateterismo Cardíaco
18.
Expert Rev Cardiovasc Ther ; 21(10): 703-712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37815845

RESUMO

INTRODUCTION: With the expanding indications of transcatheter aortic valve replacement (TAVR) to younger and low-risk patients, the life expectancy of patients currently undergoing TAVR will likely outlive the durability of transcatheter bioprosthesis. Consequently, the number of failed transcatheter bioprosthesis requiring surgical valve explant or redo TAVR is expected to increase. AREAS COVERED: The aim of this review is to provide an updated overview of redo TAVR for treating degenerated transcatheter bioprosthesis, focusing on pre-procedural planning, potential challenges of coronary reaccess during TAVR-in-TAVR and main outcomes of TAVR explant and redo TAVR. EXPERT OPINION: Patient-tailored device selection and individualized implantation height should be carefully assessed during the index TAVR procedure (weighting between pacemaker avoidance and the potential risk of coronary occlusion in future TAVR-in-TAVR). Future prospective studies comparing safety and clinical outcomes between redo TAVR vs TAVR explant are eagerly awaited.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
19.
Rev Esp Cardiol (Engl Ed) ; 76(10): 767-773, 2023 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36804557

RESUMO

INTRODUCTION AND OBJECTIVES: The cusp overlap technique (COT) has been proposed to reduce conduction disturbances (CD) after transcatheter aortic valve implantation (TAVI) with self-expanding supra-annular devices, but there are scarce data on COT with intra-annular valves. The aim of this study was to determine whether the use of the COT during Portico implantation results in higher valve implantation and lower rates of CD. METHODS: We included 85 patients undergoing TAVI with the Portico FlexNav system: 43 retrospective patients using the standard 3-cusp view and 42 prospective patients with the COT. Primary endpoints were implantation depth and new-onset CD (composite outcome of new-onset left bundle branch block and new permanent pacemaker implantation). RESULTS: COT resulted in a higher implantation depth (noncoronary cusp: 4.9±3.9 vs 7.4±3.0; P=.005) and lower new-onset CD (31.0% vs 58.1%; P=.012), with a tendency toward a lower need for permanent pacemaker implantation (14.3% vs 30.2%, P=.078; 7.7% vs 31.0%; P=.011 in patients without pre-existing right bundle branch block). Transvalvular aortic gradients were slightly lower with COT (8.7±3.7 vs 11.0±6.1; P=.044). There were no differences in technical success or major procedure-related complications. On multivariate analysis, COT use was associated with a lower risk of new-onset CD. CONCLUSIONS: Use of the COT during Portico implantation is feasible and facilitates a higher valve implant, which in turn may help to reduce rates of new-onset CD.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estudos Prospectivos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
20.
Int J Bioprint ; 9(1): 640, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36636130

RESUMO

Advanced visual computing solutions and three-dimensional (3D) printing are moving from engineering to clinical pipelines for training, planning, and guidance of complex interventions. 3D imaging and rendering, virtual reality (VR), and in-silico simulations, as well as 3D printing technologies provide complementary information to better understand the structure and function of the organs, thereby improving and personalizing clinical decisions. In this study, we evaluated several advanced visual computing solutions, such as web-based 3D imaging visualization, VR, and computational fluid simulations, together with 3D printing, for the planning of the left atrial appendage occluder (LAAO) device implantations. Six cardiologists tested different technologies in pre-operative data of five patients to identify the usability, limitations, and requirements for the clinical translation of each technology through a qualitative questionnaire. The obtained results demonstrate the potential impact of advanced visual computing solutions and 3D printing to improve the planning of LAAO interventions as well as the need for their integration into a single workflow to be used in a clinical environment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA