Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Radiol ; 25(1): 258-66, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25182631

RESUMO

OBJECTIVE: To assess whether the need for postnatal prosthetic patch repair of the diaphragmatic defect in neonates with a congenital diaphragmatic hernia (CDH) is associated with the antenatal measured observed-to-expected magnetic resonance fetal lung volume (o/e MR-FLV). METHODS: The o/e MR-FLV was calculated in 247 fetuses with isolated CDH. Logistic regression analysis was used to assess the prognostic value of the individual o/e MR-FLV for association with the need for postnatal patch repair. RESULTS: Seventy-seven percent (77%) of patients with a CDH (190/247) required prosthetic patch repair and the defect was closed primarily in 23% (57/247). Patients requiring a patch had a significantly lower o/e MR-FLV (27.7 ± 10.2%) than patients with primary repair (40.8 ± 13.8%, p < 0.001, AUC = 0.786). With an o/e MR-FLV of 20%, 92% of the patients required patch repair, compared to only 24% with an o/e MR-FLV of 60%. The need for a prosthetic patch was further influenced by the fetal liver position (herniation/no herniation) as determined by magnetic resonance imaging (MRI; p < 0.001). Fetal liver position, in addition to the o/e MR-FLV, improves prognostic accuracy (AUC = 0.827). CONCLUSION: Logistic regression analysis based on the o/e MR-FLV is useful for prenatal estimation of the prosthetic patch requirement in patients with a CDH. In addition to the o/e MR-FLV, the position of the liver as determined by fetal MRI helps improve prognostic accuracy. KEY POINTS: • The o/e MR-FLV is associated with the need for postnatal patch repair in CDH. • The need for a patch is associated with a significantly lower o/e MR-FLV (p < 0.001). • The patch requirement is also influenced by fetal liver position. • Fetal liver position, in addition to the o/e MR-FLV, improves prognostic accuracy. • CDH-fetuses with a high probability for patch requirement can be identified prenatally.


Assuntos
Hérnias Diafragmáticas Congênitas/diagnóstico , Herniorrafia/métodos , Medidas de Volume Pulmonar/métodos , Pulmão/embriologia , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Telas Cirúrgicas , Adulto , Feminino , Seguimentos , Hérnias Diafragmáticas Congênitas/cirurgia , Humanos , Recém-Nascido , Masculino , Gravidez , Prognóstico , Estudos Retrospectivos
2.
Eur Radiol ; 24(2): 312-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24096317

RESUMO

OBJECTIVE: To investigate individual changes in fetal lung volume (FLV) in fetuses with isolated congenital diaphragmatic hernia (CDH) and to calculate weekly growth rates of the FLV using serial MR examinations during pregnancy. METHODS: MR-FLV was measured in 89 fetuses with CDH. All fetuses received two MRIs. A mean weekly growth rate of the FLV was determined for each fetus and compared with the growth rate of healthy fetuses. RESULTS: Mean observed-to-expected MR-FLV (o/e MR-FLV) measured at the first MRI was 33.3 ± 12.2% and 29.5 ± 10.9% at the second MRI. In 61% of all fetuses (54/89) the o/e MR-FLV decreased during pregnancy, 26% (23/89) showed an increase in the o/e MR-FLV and 13 % (12/89) had stable values. First and last o/e MR-FLV values were significantly associated with mortality and neonatal extracorporeal membrane oxygenation (ECMO) requirement with a higher prognostic accuracy of MR-FLV measurements near delivery. Patients with CDH had lower weekly lung growth rates than healthy fetuses. There was a significant difference in the mean weekly growth rate between survivors and non-survivors and patients with and without ECMO requirement. CONCLUSION: Individual development of FLV in patients with CDH during pregnancy is extremely variable. Follow-up MR-FLV measurements are advisable before deciding upon pre- and postnatal therapeutic options. KEY POINTS: • Lung development in congenital diaphragmatic hernia (CDH) during pregnancy is extremely variable. • MRI demonstrates that lung growth rate is reduced in fetuses with CDH. • The final observed-to-expected fetal lung volume provides the best prognostic information. • Follow-up measurements are advisable before deciding upon therapeutic options.


Assuntos
Anormalidades Múltiplas/diagnóstico , Doenças Fetais/diagnóstico , Hérnias Diafragmáticas Congênitas , Pulmão/embriologia , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Anormalidades Múltiplas/embriologia , Diagnóstico Diferencial , Feminino , Seguimentos , Hérnia Diafragmática/diagnóstico , Hérnia Diafragmática/embriologia , Humanos , Recém-Nascido , Pulmão/anormalidades , Medidas de Volume Pulmonar , Masculino , Gravidez , Resultado da Gravidez , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
AJR Am J Roentgenol ; 202(6): 1330-6, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24848832

RESUMO

OBJECTIVE: The objective of our study was to evaluate the prognostic accuracy of the MRI-based ratio of fetal lung volume (FLV) to fetal body volume (FBV) for predicting survival and the need for extracorporeal membrane oxygenation (ECMO) therapy in fetuses with congenital diaphragmatic hernia (CDH). MATERIALS AND METHODS: MRI was performed in 96 fetuses (34 females and 62 males; mean gestational age, 33 ± 5 [SD] weeks; range, 23-39 weeks) with CDH and 44 healthy control subjects. FLV and FBV were measured for each fetus by one of three investigators, and we calculated the FLV/FBV ratio. Additionally, a subgroup analysis of growth-restricted fetuses was performed. Logistic regression analysis was used to model the dependence of survival and ECMO requirement on the FLV/FBV ratio. Prognostic accuracy was evaluated by applying the area under the curve (AUC). RESULTS: Seventy-eight of the 96 (81%) fetuses survived and 35 (36%) neonates needed ECMO therapy. The FLV/FBV ratio was significantly higher in fetuses who survived (p < 0.0001; AUC = 0.829). Neonates who received ECMO therapy showed a significantly lower prenatal FLV/FBV ratio (p = 0.0001; AUC = 0.811) than neonates who did not need ECMO therapy. A subgroup analysis (n = 13) showed a trend toward a higher FLV/FBV ratio of survivors in comparison with nonsurvivors (p = 0.065; AUC = 0.875). CONCLUSION: In our study, the MRI-based FLV/FBV ratio was able to predict neonatal survival and ECMO requirement in children with CDH with high accuracy. Unlike other prognostic parameters, FLV/FBV ratio is independent of a reference to a control group and may enhance prognostic accuracy particularly in growth-restricted neonatal patients.


Assuntos
Tamanho Corporal , Hérnias Diafragmáticas Congênitas , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Medidas de Volume Pulmonar/métodos , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Algoritmos , Feminino , Hérnia Diafragmática/diagnóstico , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Radiology ; 266(3): 887-95, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23238156

RESUMO

PURPOSE: To assess whether chronic lung disease (CLD) in surviving infants with congenital diaphragmatic hernia (CDH) is associated with lung hypoplasia on the basis of the results of antenatal observed-to-expected fetal lung volume (FLV) ratio measurement at magnetic resonance (MR) imaging. MATERIALS AND METHODS: The study received approval from the institutional review board, with waiver of informed consent for this retrospective review from patients who had previously given informed consent for prospective studies. The ratio of observed to expected FLV at MR imaging was calculated in 172 fetuses with CDH. At postpartum day 28, the need for supplemental oxygen implicated the diagnosis of CLD. At day 56, patients with CLD were assigned to one of three groups-those with mild, moderate, or severe CLD-according to their demand for oxygen. Logistic regression analysis was used to assess the prognostic value of the individual observed-to-expected FLV ratio for association with postnatal development of CLD. RESULTS: Children with CLD were found to have significantly smaller observed-to-expected FLV ratios at MR imaging than infants without CLD (P < .001). Grading of CLD revealed significant differences in observed-to-expected FLV ratio between patients with mild CLD and those with moderate (P = .012) or severe (P = .007) CLD. For an observed-to-expected FLV ratio of 5%, 99% of patients with CDH developed CLD, compared with less than 5% of fetuses with an observed-to-expected FLV ratio of 50%. Perinatally, development and grade of CLD were further influenced by the need for extracorporeal membrane oxygenation (ECMO) (P < .001) and gestational age at delivery (P = .009). CONCLUSION: Manifestation of CLD in surviving infants with CDH is associated with the prenatally determined observed-to-expected FLV ratio. Early neonatal therapeutic decisions can additionally be based on this ratio. Perinatally, ECMO requirement and gestational age at delivery are useful in further improving the estimated probability of CLD.


Assuntos
Hérnia Diafragmática/epidemiologia , Hérnia Diafragmática/patologia , Lesão Pulmonar/epidemiologia , Lesão Pulmonar/patologia , Medidas de Volume Pulmonar , Imageamento por Ressonância Magnética/estatística & dados numéricos , Diagnóstico Pré-Natal/métodos , Comorbidade , Feminino , Alemanha/epidemiologia , Hérnias Diafragmáticas Congênitas , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Prevalência , Prognóstico , Fatores de Risco , Sensibilidade e Especificidade
5.
AJR Am J Roentgenol ; 201(2): 419-26, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23883224

RESUMO

OBJECTIVE: The purpose of the study was to investigate the ability to predict survival, need for extracorporeal membrane oxygenation (ECMO), and incidence of chronic lung disease in patients with congenital diaphragmatic hernia in the context of a classification into three different times of gestation (< 28, 28-32, and > 32 weeks) by assessing the ratio between observed and expected MRI fetal lung volume. MATERIALS AND METHODS: The data analysis included 226 fetuses with congenital diaphragmatic hernia. MRI was performed at different times of gestation with a T2-weighted HASTE sequence. Receiver operating characteristic curve analysis was performed to investigate the prognostic value of assessment of the ratio between observed and expected MRI fetal lung volumes at different stages of fetal growth. RESULTS: For all reviewed times of gestation, the ratio between observed and expected MRI fetal lung volumes had almost equivalent statistically significant differences for neonatal survival (p ≤ 0.0029), need for ECMO therapy (p ≤ 0.0195), and development of chronic lung disease (p ≤ 0.0064). Results with high prognostic accuracy for early and for medium and late times in gestation also were obtained. Receiver operating characteristic analysis showed the highest area under the curve (≥ 0.819) for neonatal survival. CONCLUSION: In patients with congenital diaphragmatic hernia, the relation between observed and expected MRI fetal lung volume is a valuable prognostic parameter for predicting neonatal mortality, morbidity represented by the development of chronic lung disease, and the need for ECMO therapy in early gestation (< 28 weeks) as well as later gestation with no statistically significant differences.


Assuntos
Oxigenação por Membrana Extracorpórea , Hérnias Diafragmáticas Congênitas , Pneumopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Área Sob a Curva , Distribuição de Qui-Quadrado , Feminino , Hérnia Diafragmática/diagnóstico , Hérnia Diafragmática/terapia , Humanos , Recém-Nascido , Modelos Logísticos , Medidas de Volume Pulmonar , Masculino , Valor Preditivo dos Testes , Gravidez , Curva ROC , Índice de Gravidade de Doença , Taxa de Sobrevida
6.
Pediatr Crit Care Med ; 13(1): 66-71, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21478793

RESUMO

OBJECTIVE: To systematically investigate the impact of the location of the defect in congenital diaphragmatic hernia on neonatal mortality and morbidity with a special focus on survival at discharge, extracorporeal membrane oxygenation requirement, and the development of chronic lung disease. DESIGN: Retrospective tertiary care center study with a matched-pair analysis of all fetuses that were treated for congenital diaphragmatic hernia between 2004 and 2009. SETTING: A specialized tertiary care center for fetuses with congenital diaphragmatic hernia. PATIENTS: Complete sets of data were available for 106 patients with congenital diaphragmatic hernia. For 17 of 18 infants with right-sided congenital diaphragmatic hernia we were able to allocate infants with left-sided congenital diaphragmatic hernia with no relevant difference in previously described prognostic factors, such as pulmonary hypoplasia and liver herniation. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: There was a strong trend toward better survival in infants with right-sided congenital diaphragmatic hernia than with left-sided congenital diaphragmatic hernia (94% vs. 70%; p = .07). More neonates with left-sided congenital diaphragmatic hernia died of severe pulmonary hypertension despite extracorporeal membrane oxygenation. Fewer neonates with right-sided congenital diaphragmatic hernia died, yet higher degrees of pulmonary hypoplasia and oxygen requirement were observed despite extracorporeal membrane oxygenation. CONCLUSIONS: In congenital diaphragmatic hernia, the location of the defect has a substantial impact on postnatal survival and the development of chronic lung disease. In left-sided congenital diaphragmatic hernia, pulmonary hypertension resistant to therapeutic management, including extracorporeal membrane oxygenation, is more common and is associated with a higher rate of neonatal demise. Right-sided congenital diaphragmatic hernia infants have an increased benefit from extracorporeal membrane oxygenation but the better survival entails a higher rate of chronic lung disease.


Assuntos
Doenças Fetais/diagnóstico , Hérnias Diafragmáticas Congênitas , Toracoscopia/métodos , Estudos de Casos e Controles , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Seguimentos , Hérnia Diafragmática/mortalidade , Hérnia Diafragmática/patologia , Hérnia Diafragmática/cirurgia , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Gravidez , Diagnóstico Pré-Natal/métodos , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Toracoscopia/efeitos adversos , Resultado do Tratamento
7.
AJR Am J Roentgenol ; 192(1): 153-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19098195

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the prognostic accuracy of a new MRI-based relative lung-to-head ratio in regard to neonatal survival and need for extracorporeal membrane oxygenation (ECMO) in the care of fetuses with congenital diaphragmatic hernia (CDH) and to compare it with the previously described sonographic relative lung-to-head ratio and relative fetal lung volume assessed at antenatal MRI. MATERIALS AND METHODS: Sonographic lung-to-head ratio and MRI fetal lung volume were measured in 90 fetuses (mean gestational age, 31.4+/-4.1 weeks) with CDH. Sonographic relative lung-to-head ratio and MRI relative fetal lung volume were assessed by expressing the observed sonographic lung-to-head ratio and MRI fetal lung volume as a percentage of the expected parameter value. The new MRI relative lung-to-head ratio was assessed as a percentage of the expected MRI lung-to-head ratio based on MRI fetal lung volume and MRI head circumference measurements. Measurements for survival and ECMO requirement were determined with the area under the curve (AUC). Data were analyzed for left-sided defects, right-sided defects, and associated liver herniation. RESULTS: Among fetuses with left-sided CDH, all parameters were excellent in determining neonatal survival and need for ECMO therapy (p

Assuntos
Cabeça/patologia , Hérnia Diafragmática/patologia , Hérnias Diafragmáticas Congênitas , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Diagnóstico Pré-Natal/métodos , Feminino , Cabeça/diagnóstico por imagem , Hérnia Diafragmática/diagnóstico por imagem , Hérnia Diafragmática/embriologia , Humanos , Pulmão/diagnóstico por imagem , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
8.
Radiology ; 248(1): 233-9, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18566175

RESUMO

PURPOSE: To prospectively assess the results of logistic regression analysis that were based on magnetic resonance (MR) image fetal lung volume (FLV) measurements to predict survival and the corresponding need for extracorporeal membrane oxygenation (ECMO) therapy in fetuses with congenital diaphragmatic hernia (CDH) before and after 30 weeks gestation. MATERIALS AND METHODS: Written informed consent was obtained and the study was approved by the local research ethics committee. FLV was measured on MR images in 95 fetuses (52 female neonates, 43 male neonates) with CDH between 22 and 39 weeks gestation by using multiplanar T2-weighted half-Fourier acquired single-shot turbo spin-echo MR imaging. On the basis of logistic regression analysis results, mortality and the need for ECMO therapy were calculated for fetuses before and after 30 weeks gestation. RESULTS: Overall, higher FLV was associated with improved survival (P < .001) and decreasing probability of need for ECMO therapy (P = .008). Survival at discharge was 29.2% in neonates with an FLV of 5 mL, compared with 99.7% in neonates with an FLV of 25 mL. The corresponding need for ECMO therapy was 56.1% in fetuses with an FLV of 5 mL and 8.7% in fetuses with an FLV of 40 mL. Prognostic power was considerably lower before 30 weeks gestation. CONCLUSION: Beyond 30 weeks gestation, logistic regression analysis that is based on MR FLV measurements is useful to estimate neonatal survival rates and ECMO requirements. Prior to 30 weeks gestation, the method is not reliable and the FLV measurement should be repeated, particularly in fetuses with small lung volumes, before a decision is made about therapeutic options.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Hérnia Diafragmática , Medidas de Volume Pulmonar/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos de Riscos Proporcionais , Feminino , Alemanha/epidemiologia , Hérnia Diafragmática/diagnóstico , Hérnia Diafragmática/mortalidade , Hérnia Diafragmática/reabilitação , Hérnias Diafragmáticas Congênitas , Humanos , Recém-Nascido , Modelos Logísticos , Masculino , Prevalência , Prognóstico , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sobrevida , Taxa de Sobrevida
9.
Radiology ; 248(1): 240-6, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18566176

RESUMO

PURPOSE: To retrospectively evaluate the accuracy of the absolute fetal lung volume (FLV) measured at magnetic resonance (MR) imaging and seven formulas for calculating relative FLV to predict neonatal survival and the need for extracorporeal membrane oxygenation (ECMO) in fetuses with congenital diaphragmatic hernia (CDH). MATERIALS AND METHODS: This retrospective study was approved by the research ethics committee, and informed consent was received from all mothers for previous prospective studies. In total, 68 fetuses with CDH were assessed by using MR image FLV measurement within 23-39 weeks gestation. The relative FLV was expressed as a percentage of the predicted lung volume calculated with biometric parameters according to seven formulas previously described in the literature. Applying the area under the curve (AUC), the various relative FLVs and the absolute FLV were investigated for their prognostic accuracy to predict neonatal survival and the need for ECMO therapy. RESULTS: All relative FLVs and the absolute FLV revealed a significant difference in mean lung volume between neonates who survived and neonates who did not survive (P = .001 to P < .001) and measurement accuracy was excellent for each method (AUC, 0.800-0.900). For predicting neonatal ECMO requirement, differences in FLVs were smaller but still significant (P = .05 to <.009) and measurement accuracy was acceptable throughout (AUC, 0.653-0.739). CONCLUSION: The various relative FLVs and the absolute FLV measured at MR planimetry are each highly valuable in predicting survival in fetuses with CDH. For predicting whether neonatal ECMO therapy is required, the accuracy of the absolute FLV (AUC, 0.68) and that of the relative FLVs (AUC, 0.653-0.739) was acceptable.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Hérnia Diafragmática , Medidas de Volume Pulmonar/métodos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos de Riscos Proporcionais , Feminino , Alemanha/epidemiologia , Hérnia Diafragmática/diagnóstico , Hérnia Diafragmática/mortalidade , Hérnia Diafragmática/reabilitação , Hérnias Diafragmáticas Congênitas , Humanos , Recém-Nascido , Modelos Logísticos , Masculino , Prevalência , Prognóstico , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sobrevida , Taxa de Sobrevida
10.
Radiology ; 246(2): 553-61, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18055874

RESUMO

PURPOSE: To prospectively assess the reliability of magnetic resonance (MR) image volume measurement in fetuses with congenital diaphragmatic hernia (CDH) and the reliability and validity of measurements in in vitro lung models. MATERIALS AND METHODS: This study was approved by the ethics committee, and informed consent was obtained. MR fetal lung volume (FLV) was measured in 40 consecutive fetuses with CDH by using half-Fourier acquired single-shot turbo spin-echo MR imaging and true fast imaging with steady-state precession at 24-36 weeks gestation (mean gestational age, 30.6 weeks +/- 3.5 [standard deviation]). Lung volumes were independently assessed in three orthogonal section planes by two experienced observers. Additionally, 28 in vitro lung models of defined volumes of 1-60 mL were evaluated the same way. To assess measurement validity and reliability, the intraclass correlation coefficient (ICC) and the Bland-Altman plot were used. RESULTS: The interobserver reliability was high for both the lung models and FLV measurements (ICC, 0.999 and 0.928, respectively). Measurement validity was also good, with a mean difference between the calculated volume and the true volume of 0.4 mL (95% confidence interval: 0.30, 0.48). Measurement reliability and validity did not depend, to any considerable degree, on imaging plane or sequence (ICC range, 0.878-0.999) or on total volume. CONCLUSION: The reliability and validity of MR volume measurements are high. The method is independent of the sequence and the imaging plane and can be performed with a very good interobserver agreement, even in small volumes.


Assuntos
Feto/patologia , Hérnia Diafragmática/diagnóstico , Hérnias Diafragmáticas Congênitas , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Medidas de Volume Pulmonar/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
AJR Am J Roentgenol ; 189(6): 1307-11, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18029863

RESUMO

OBJECTIVE: The purpose of this study was to use logistic regression analysis of prenatal MRI fetal lung volume measurements to calculate mortality and the need for extracorporeal membrane oxygenation (ECMO) therapy among fetuses with congenital diaphragmatic hernia (CDH). SUBJECTS AND METHODS: The fetal lung volume measurements of 65 fetuses with CDH were obtained between 32 and 34 weeks' gestation by means of MRI performed with multiplanar T2-weighted HASTE and true fast imaging with steady-state precession sequences. Logistic regression analysis was used to assess the prognostic value of the fetal lung volume measurements for prenatal prediction of fetal survival and need for neonatal ECMO. RESULTS: Fetal lung volume was a highly significant predictor of survival (p < 0.0001) and neonatal ECMO requirement (p = 0.0006). The mortality was 84% and the ECMO requirement 80% among fetuses with a lung volume of 5 mL. The mortality was 0.4% and the ECMO requirement 20% among patients with a fetal lung volume of 30 mL. CONCLUSION: Logistic regression analysis of MRI fetal lung volume measurements is highly valuable in predicting mortality among neonates with CDH, and it may help to estimate the need for neonatal ECMO. The method is feasible for facilitating parental guidance and may help in choosing postnatal therapeutic options, including ECMO therapy.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Monitorização Fetal/estatística & dados numéricos , Hérnia Diafragmática/mortalidade , Hérnia Diafragmática/prevenção & controle , Imageamento por Ressonância Magnética/estatística & dados numéricos , Medição de Risco/métodos , Feminino , Alemanha/epidemiologia , Hérnia Diafragmática/diagnóstico , Hérnias Diafragmáticas Congênitas , Humanos , Imageamento Tridimensional/estatística & dados numéricos , Modelos Logísticos , Masculino , Prevalência , Prognóstico , Análise de Regressão , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Volume de Ventilação Pulmonar
12.
Clin Nucl Med ; 39(3): e197-201, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24092230

RESUMO

PURPOSE: Image quality (IQ) of PET in voluminous body regions can be limited, which impairs the assessment of small metastatic lesions. Time-of-flight (TOF) reconstruction algorithm may deliver an increase of spatial resolution. The purpose of this study was to evaluate the impact of TOF on IQ, lesion detection rate, lesion volume (V) and SUVmax in F choline PET/CT of prostate cancer patients with biochemical recurrence compared to standard PET/CT reconstruction (standard). PATIENTS AND MATERIALS: During a period of 9 months, 32 patients with prostate cancer (mean [SD] age, 71 [7.8] years) and biochemical recurrence were included in this prospective institutional review board-approved study. Each patient underwent a state-of-the-art 3-dimensional F choline PET/CT. A total of 76 lesions were assessed by 2 board-certified nuclear medicine physicians and a third-year resident. Lesion volume and SUVmax of local recurrence, lymph nodes, and organ metastases were compared between TOF and standard. Image quality and lesion demarcation were rated according to a 5-point Likert-type scale. Interobserver agreement was assessed. RESULTS: Eight additional lesions were detected using TOF (SUVmax, 3.64 [0.95]; V, 0.58 cm [0.50]). Image quality was reduced (IQ standard, 1.28; TOF, 1.77; P < 0.01) in calculated TOF images, although quality of lesion demarcation was improved (lesion demarcation: standard, 1.66; TOF, 1.26; P < 0.01). SUVmax was significantly increased in TOF images (SUVmax standard, 6.9 [4.1]; TOF, 8.1 [4.1]; P < 0.01), whereas V did not show significant differences (V standard, 5.3 [10.4] cm; TOF, 5.4 [10.3] cm; P = 0.41). Interobserver agreement was good for combined ratings (1 + 2 and 3 + 4). CONCLUSIONS: Application of TOF seems to be of additional value to detect small metastatic lesions in patients with prostate cancer and biochemical recurrence, which may have further clinical implications for secondary treatment.


Assuntos
Algoritmos , Colina/análogos & derivados , Processamento de Imagem Assistida por Computador , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Masculino , Imagem Multimodal , Recidiva Local de Neoplasia/patologia , Variações Dependentes do Observador , Neoplasias da Próstata/patologia
13.
Nucl Med Biol ; 40(2): 206-13, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23228852

RESUMO

INTRODUCTION: Chronically altered glucose metabolism interferes with (18)F-FDG uptake in malignant tissue and healthy organs and may therefore lower tumor detection in (18)F-FDG PET/CT. The present study assesses the impact of elevated blood glucose levels (BGL), diabetes, insulin treatment, and obesity on (18)F-FDG uptake in tumors and biodistribution in normal organ tissues. METHODS: (18)F-FDG PET/CT was analyzed in 90 patients with BGL ranging from 50 to 372 mg/dl. Of those, 29 patients were diabetic and 21 patients had received insulin prior to PET/CT; 28 patients were obese with a body mass index >25. The maximum standardized uptake value (SUV(max)) of normal organs and the main tumor site was measured. Differences in SUV(max) in patients with and without elevated BGLs, diabetes, insulin treatment, and obesity were compared and analyzed for statistical significance. RESULTS: Increased BGLs were associated with decreased cerebral FDG uptake and increased uptake in skeletal muscle. Diabetes and insulin diminished this effect, whereas obesity slightly enhanced the outcome. Diabetes and insulin also increased the average SUV(max) in muscle cells and fat, whereas the mean cerebral SUV(max) was reduced. Obesity decreased tracer uptake in several healthy organs by up to 30%. Tumoral uptake was not significantly influenced by BGL, diabetes, insulin, or obesity. CONCLUSIONS: Changes in BGLs, diabetes, insulin, and obesity affect the FDG biodistribution in muscular tissue and the brain. Although tumoral uptake is not significantly impaired, these findings may influence the tumor detection rate and are therefore essential for diagnosis and follow-up of malignant diseases.


Assuntos
Glicemia/metabolismo , Complicações do Diabetes/metabolismo , Fluordesoxiglucose F18/metabolismo , Insulina/farmacologia , Imagem Multimodal , Neoplasias/metabolismo , Obesidade/complicações , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Transporte Biológico/efeitos dos fármacos , Complicações do Diabetes/diagnóstico por imagem , Complicações do Diabetes/tratamento farmacológico , Complicações do Diabetes/fisiopatologia , Feminino , Humanos , Rim/fisiopatologia , Fígado/fisiopatologia , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Neoplasias/fisiopatologia , Padrões de Referência , Estudos Retrospectivos
14.
Radiology ; 235(1): 177-83, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15731373

RESUMO

PURPOSE: To prospectively evaluate incidence of clinically silent and clinically apparent embolic cerebral infarction following diagnostic and interventional coronary angiography and associated risk factors. MATERIALS AND METHODS: Written informed consent was obtained from all patients, and the study was approved by the research ethics committee of University of Heidelberg, Germany. Fifty-two patients, including 37 men (mean age, 66.1 years +/- 11.9 [standard deviation]) and 15 women (mean age, 65.3 years +/- 10.3), undergoing elective cardiac catheterization were examined 3-26 hours (mean, 15.3 hours +/- 6) before and 12-48 hours (mean, 25.9 hours +/- 10.4) after cardiac catheterization. Magnetic resonance imaging protocol included isotropic and anisotropic diffusion-weighted single-shot echo-planar sequences. T2-weighted turbo spin-echo and T1-weighted spin-echo sequences also were performed. Apparent diffusion coefficient maps were calculated to exclude false-positive reading results on diffusion-weighted images because of T2 shine-through effect. Images were assessed by two experienced radiologists blinded to clinical data. Cardiac catheterization was performed by 11 experienced cardiologists to exclude operator-related risk. A neurologic examination according to the National Institutes of Health Stroke Scale and Barthel index was performed by a senior cardiologist before acquisition of each image. Sixteen clinical and angiographic variables were analyzed with univariate analysis for ability to predict occurrence of cerebral infarction. RESULTS: No embolic cerebral lesions could be detected at diffusion-weighted imaging before catheterization. After coronary angiography, seven (15%) of 48 patients demonstrated nine focal cerebral infarcts affecting anterior and posterior circulation. Patients remained asymptomatic. Of all tested variables, only duration of the procedure was identified as an independent predictor of occurrence of cerebral infarction (P < .05). CONCLUSION: In this prospective study, asymptomatic cerebral infarction following cardiac catheterization occurred in 15% of patients in whom duration of the procedure was significantly longer than in those without infarction (P = .017).


Assuntos
Cateterismo Cardíaco/efeitos adversos , Infarto Cerebral/epidemiologia , Infarto Cerebral/etiologia , Imagem de Difusão por Ressonância Magnética , Idoso , Infarto Cerebral/diagnóstico , Feminino , Humanos , Incidência , Masculino , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA