Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(6): e14353, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38693646

RESUMO

BACKGROUND: A physical scatter grid is not often used in pelvic bedside examinations. However, multiple studies regarding scatter correction software (SC SW) are available for mobile chest radiography but the results are unclear for pelvic radiography. PURPOSE: We evaluated SC SW of Fujifilm (Virtual Grid) on gridless pelvic radiographs obtained from a human Thiel-embalmed body to investigate the potential of Virtual Grid in pelvic bedside examinations. METHODS: Gridless, Virtual Grid, and physical grid pelvic radiographs of a female Thiel-embalmed body were collected with a broad range of tube loads. Different software (SW) grid ratios-6:1, 10:1, 13:1, 17:1, and 20:1-were applied on the gridless radiographs to investigate the image quality (IQ) improvement of 13 IQ criteria in a visual grading analysis (VGA) setup. RESULTS: Gridless radiograph scores are significantly lower (p < 0.001) than Virtual Grid and physical grid scores obtained with the same tube load. Virtual Grid radiographs score better than gridless radiographs obtained with a higher tube load which makes a dose reduction possible. The averaged ratings of the IQ criteria processed with different SW ratios increase with increasing SW grid ratios. However, no statistically significant differences were found between the SW grid ratios. The scores of the physical grid radiographs are higher than those of the Virtual Grid radiographs when they are obtained with the same tube load. CONCLUSION: We conclude that Virtual Grid with an SW ratio of 6:1 improves the IQ of gridless pelvic radiographs in such a manner that a dose reduction is possible. However, physical grid radiograph ratings are higher compared to those of Virtual Grid radiographs.


Assuntos
Pelve , Humanos , Feminino , Pelve/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Software , Espalhamento de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Imagens de Fantasmas
2.
Artigo em Inglês | MEDLINE | ID: mdl-38042252

RESUMO

OBJECTIVE: This study reports the development of an innovative, interactive Massive Open Online Course (MOOC) teaching radiation safety principles in the vascular workplace, using stepwise e-learning with multiple choice question tests (MCQs), educational videos, and a serious game. The aim was to study the MOOC impact on radiation safety knowledge and assess its feasibility and acceptability. METHODS: An international multicentre prospective study included team members active in the hybrid operating room. The MOOC was offered voluntarily via a secure online learning platform. A standardised MCQ test (15 questions) assessed radiation safety knowledge pre- and post-course (range 0 - 100%). Acceptability and feasibility were tested via the previously validated, Evaluating e-learning system success (EESS) model, using five point Likert scales. RESULTS: In eight centres across four countries, 150 of 203 invited endovascular team members consented. Over a seven week study period, surgeons (28%, including vascular surgery trainees and consultants), nurses (27%, including scrub, circulating and anaesthetic nurses), anaesthetists (43%, including trainees and consultants), and radiographers (3%) participated. Of those, 67% completed the course. The average radiation knowledge improved by 22.8% (95% CI 19.5 - 26.0%; p < .001) after MOOC completion, from 48% to 71% (standard deviation [SD] 14 and 15% respectively), requiring a mean time investment of 169 minutes (SD 89 minutes). In centres with a radiographer, mean knowledge gain after MOOC completion was significantly smaller (14%, SD 19% vs. 24%, SD 16%, p = .036). The course was deemed feasible and acceptable according to the EESS model with a total mean score of 3.68/5. CONCLUSION: This newly developed, multimodal MOOC was deemed feasible and effective across multiple international centres. The MOOC significantly contributes to radiation safety education of the entire endovascular team, improving radiation safety knowledge. The course may optimise workplace radiation safety behaviour and therefore enhance team and patient safety.

3.
Radiology ; 288(1): 164-169, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29584596

RESUMO

Purpose To assess the potential dose reduction to the thyroid and breasts in chest computed tomography (CT) with organ-based tube current modulation (OBTCM). Materials and Methods In this retrospective study (from January 2015 to December 2016), the location of the breasts with respect to the reduced tube current zone was determined. With Monte Carlo simulations, patient-specific dose distributions of chest CT scans were calculated for 50 female patients (mean age, 53.7 years ± 17.5; range, 20-80 years). The potential dose reduction with OBTCM was assessed. In addition, simulations of clinical OBTCM scans were made for 17 of the 50 female patients (mean age, 43.8 years ± 17.1; range, 20-69 years). Posterior organs in the field of view were analyzed and lifetime attributable risk (LAR) of cancer incidence and mortality was estimated. Image quality between standard CT and OBTCM scans was compared. Results No women had all breast tissue within the reduced tube current zone. Dose reductions of 18% in the thyroid and 9% in the breasts were observed, whereas the doses in lung, liver, and kidney were 17%, 11%, and 26% higher. Overall, the LAR for cancer incidence was not significantly different between conventional and OBTCM scanning (P = .06). Image quality improved with OBTCM (P < .002). Conclusion The potential benefit of OBTCM to the female breast in chest CT is overestimated because of a limited reduced tube current zone; despite a 9% dose reduction to the female breast, posterior organs will absorb up to 26% more radiation, resulting in no reduction in radiation-induced malignancies. © RSNA, 2018.


Assuntos
Mama/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Glândula Tireoide/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Método de Monte Carlo , Estudos Retrospectivos , Risco , Adulto Jovem
4.
J Interv Cardiol ; 31(6): 807-814, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30168209

RESUMO

INTRODUCTION: Cardiac catheterization procedures result in high patient radiation exposure and corresponding staff doses are reported to be among the highest for medical staff. The purpose of current randomized controlled study was to quantify the potential radiation dose reduction for both patient and staff, enabled by recent X-ray technology. This technology is equipped with advanced image processing algorithms, real-time dose monitoring, and an acquisition chain optimized for cardiac catheterization applications. METHODS: A total of 122 adult patients were randomly assigned to one of two cath labs, either the reference X-ray modality (Allura Xper FD10, Philips Healthcare, the Netherlands) or the new X-ray system (AlluraClarity FD20/10 Philips Healthcare, the Netherlands). Exposure parameters and staff dosimeter readings were recorded for each exposure. Technical measurements were performed to define the radiation scatter behavior. RESULTS: With the newer equipment, patient radiation dose is reduced (as total dose-area product) by 67% based on geometric means with 95%CI of 53%, 77% for diagnostic and interventional procedures. The C-arm and leg dosimeter readings were both reduced with 65% (P < 0.001), while for the collar and chest dosimeter readings no statistically significant reduction was noticed. CONCLUSION: The new x-ray and image processing technology, significantly reduces patient dose in coronary angiographies, and PCIs by 67%. In general, scatter dose was also reduced, yet for some dosimeters the reduction was limited and not statistically significant. This study clearly indicates that the scatter behavior is highly dependent on C-arm rotation, operator movement and height, dosimeter position, beam filtration, clinical procedure type and system geometry.


Assuntos
Cateterismo Cardíaco/instrumentação , Angiografia Coronária/instrumentação , Exposição Ocupacional/estatística & dados numéricos , Exposição à Radiação/estatística & dados numéricos , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/estatística & dados numéricos , Feminino , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Dosímetros de Radiação , Fatores de Risco , Raios X
6.
Eur Radiol ; 27(9): 3810-3819, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28289944

RESUMO

OBJECTIVES: To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. METHODS: The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. RESULTS: Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. CONCLUSIONS: DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration. KEY POINTS: • Interval cancer rate increases gradually with breast density, regardless of modality. • Cancer detection rate in high-density breasts is superior in DR. • IC rate exceeds CDR for SF and CR in high-density breasts. • DR performs better in high-density breasts for third readings and false-positives.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Programas de Rastreamento/métodos , Idoso , Bélgica , Detecção Precoce de Câncer/métodos , Feminino , Finlândia , Humanos , Mamografia/normas , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos
7.
Eur Radiol ; 26(8): 2646-55, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26670320

RESUMO

OBJECTIVES: To develop a clinically applicable method to estimate patient-specific organ and blood doses and lifetime attributable risks (LAR) from paediatric torso CT examinations. METHODS: Individualized voxel models were created from full-body CT data of 10 paediatric patients (2-18 years). Patient-specific dose distributions of chest and abdominopelvic CT scans were simulated using Monte Carlo methods. Blood dose was calculated as a weighted sum of simulated organ doses. LAR of cancer incidence and mortality were estimated, according to BEIR-VII. A second simulation and blood dose calculation was performed using only the thoracic and abdominopelvic region of the original voxel models. For each simulation, the size-specific dose estimate (SSDE) was calculated. RESULTS: SSDE showed a significant strong linear correlation with organ dose (r > 0.8) and blood dose (r > 0.9) and LAR (r > 0.9). No significant differences were found between blood dose calculations with the full-body voxel models and the thoracic or abdominopelvic models. CONCLUSION: Even though clinical CT images mostly do not cover the whole body of the patient, they can be used as a voxel model for blood dose calculation. In addition, SSDE can estimate patient-specific organ and blood doses and LAR in paediatric torso CT examinations. KEY POINTS: • Blood dose can be simulated using the patient's clinical CT images. • SSDE estimates patient-specific organ/blood dose and LAR in paediatric CAP CT-examinations. • SSDE makes on-the-spot dose and LAR estimations possible in routine clinical practice.


Assuntos
Abdome/diagnóstico por imagem , Neoplasias Induzidas por Radiação/epidemiologia , Órgãos em Risco , Pelve/diagnóstico por imagem , Doses de Radiação , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/efeitos adversos , Adolescente , Criança , Pré-Escolar , Simulação por Computador , Feminino , Humanos , Masculino , Modelos Teóricos , Método de Monte Carlo , Neoplasias Induzidas por Radiação/etiologia , Tomografia Computadorizada por Raios X/métodos
8.
Catheter Cardiovasc Interv ; 86(5): E205-12, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25754018

RESUMO

OBJECTIVES: The purpose of this study was to quantify the reduction in patient radiation dose during coronary angiography (CA) by a new X-ray technology, and to assess its impact on diagnostic image quality. BACKGROUND: Recently, a novel X-ray imaging technology has become available for interventional cardiology, using advanced image processing and an optimized acquisition chain for radiation dose reduction. METHODS: 70 adult patients were randomly assigned to a reference X-ray system or the novel X-ray system. Patient demographics were registered and exposure parameters were recorded for each radiation event. Clinical image quality was assessed for both patient groups. RESULTS: With the same angiographic technique and a comparable patient population, the new imaging technology was associated with a 75% reduction in total kerma-area product (KAP) value (decrease from 47 Gycm2 to 12 Gycm2, P<0.001). Clinical image quality showed an equivalent detail and contrast for both imaging systems. On the other hand, the subjective appreciation of noise was more apparent in images of the new image processing system, acquired at lower doses, compared to the reference system. However, the higher noise content did not affect the overall image quality score, which was adequate for diagnosis in both systems. CONCLUSIONS: For the first time, we present a new X-ray imaging technology, combining advanced noise reduction algorithms and an optimized acquisition chain, which reduces patient radiation dose in CA drastically (75%), while maintaining diagnostic image quality. Use of this technology may further improve the radiation safety of cardiac angiography and interventions.


Assuntos
Cineangiografia/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Idoso , Algoritmos , Cineangiografia/instrumentação , Angiografia Coronária/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
9.
Neuroradiology ; 57(8): 841-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25929982

RESUMO

INTRODUCTION: Metal artifacts may negatively affect radiologic assessment in the oral cavity. The aim of this study was to evaluate different metal artifact reduction techniques for metal artifacts induced by dental hardware in CT scans of the oral cavity. METHODS: Clinical image quality was assessed using a Thiel-embalmed cadaver. A Catphan phantom and a polymethylmethacrylate (PMMA) phantom were used to evaluate physical-technical image quality parameters such as artifact area, artifact index (AI), and contrast detail (IQFinv). Metal cylinders were inserted in each phantom to create metal artifacts. CT images of both phantoms and the Thiel-embalmed cadaver were acquired on a multislice CT scanner using 80, 100, 120, and 140 kVp; model-based iterative reconstruction (Veo); and synthesized monochromatic keV images with and without metal artifact reduction software (MARs). Four radiologists assessed the clinical image quality, using an image criteria score (ICS). RESULTS: Significant influence of increasing kVp and the use of Veo was found on clinical image quality (p = 0.007 and p = 0.014, respectively). Application of MARs resulted in a smaller artifact area (p < 0.05). However, MARs reconstructed images resulted in lower ICS. CONCLUSION: Of all investigated techniques, Veo shows to be most promising, with a significant improvement of both the clinical and physical-technical image quality without adversely affecting contrast detail. MARs reconstruction in CT images of the oral cavity to reduce dental hardware metallic artifacts is not sufficient and may even adversely influence the image quality.


Assuntos
Artefatos , Implantes Dentários , Metais , Boca/diagnóstico por imagem , Radiografia Dentária/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Cadáver , Humanos , Imagens de Fantasmas , Doses de Radiação , Radiografia Dentária/instrumentação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
10.
J Comput Assist Tomogr ; 39(4): 591-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26182227

RESUMO

OBJECTIVE: To compare the organ doses and lifetime-attributable risk of cancer for electrocardiogram-triggered sequential and high-pitch helical scanning in a clinical patient population. METHODS: Phantom thermoluminiscence dosimeter measurements were used as a model for the organ dose assessment of 314 individual patients who underwent coronary computed tomographic angiography. Patient-specific lifetime-attributable cancer risks were calculated. RESULTS: Phantom measurements showed that heart rate had a significant influence on the delivered radiation exposure in sequential mode, and calcium scoring and contrast bolus tracking scans make a nonnegligible contribution to patients' dose. Therefore, they should be taken into account for patients' organ dose estimations. Median cancer induction risks are low, with 0.008% (0.0016%) and 0.022% (0.056%) for high-pitch and sequential scanning for men (women), respectively. CONCLUSIONS: The use of high-pitch helical scanning leads to 65% and 72% lower lifetime-attributable risk values for men and women, respectively, compared with sequential scanning.


Assuntos
Angiografia Coronária/métodos , Doses de Radiação , Tomografia Computadorizada Espiral/métodos , Técnicas de Imagem de Sincronização Cardíaca , Estudos de Coortes , Feminino , Coração , Frequência Cardíaca , Humanos , Masculino , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Risco , Dosimetria Termoluminescente/estatística & dados numéricos
11.
BMC Med Imaging ; 15: 32, 2015 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-26286596

RESUMO

BACKGROUND: The first aim of this study was to evaluate the correlation between clinical and physical-technical image quality applied to different strengths of iterative reconstruction in chest CT images using Thiel cadaver acquisitions and Catphan images. The second aim was to determine the potential dose reduction of iterative reconstruction compared to conventional filtered back projection based on different clinical and physical-technical image quality parameters. METHODS: Clinical image quality was assessed using three Thiel embalmed human cadavers. A Catphan phantom was used to assess physical-technical image quality parameters such as noise, contrast-detail and contrast-to-noise ratio (CNR). Both Catphan and chest Thiel CT images were acquired on a multislice CT scanner at 120 kVp and 0.9 pitch. Six different refmAs settings were applied (12, 30, 60, 90, 120 and 150refmAs) and each scan was reconstructed using filtered back projection (FBP) and iterative reconstruction (SAFIRE) algorithms (1,3 and 5 strengths) using a sharp kernel, resulting in 24 image series. Four radiologists assessed the clinical image quality, using a visual grading analysis (VGA) technique based on the European Quality Criteria for Chest CT. RESULTS: Correlation coefficients between clinical and physical-technical image quality varied from 0.88 to 0.92, depending on the selected physical-technical parameter. Depending on the strength of SAFIRE, the potential dose reduction based on noise, CNR and the inverse image quality figure (IQF(inv)) varied from 14.0 to 67.8%, 16.0 to 71.5% and 22.7 to 50.6% respectively. Potential dose reduction based on clinical image quality varied from 27 to 37.4%, depending on the strength of SAFIRE. CONCLUSION: Our results demonstrate that noise assessments in a uniform phantom overestimate the potential dose reduction for the SAFIRE IR algorithm. Since the IQF(inv) based dose reduction is quite consistent with the clinical based dose reduction, an optimised contrast-detail phantom could improve the use of contrast-detail analysis for image quality assessment in chest CT imaging. In conclusion, one should be cautious to evaluate the performance of CT equipment taking into account only physical-technical parameters as noise and CNR, as this might give an incomplete representation of the actual clinical image quality performance.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Tórax/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Cadáver , Feminino , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
12.
Eur Radiol ; 24(8): 1808-19, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24816932

RESUMO

OBJECTIVES: To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). METHODS: Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. RESULTS: Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30% in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. CONCLUSIONS: No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. KEY POINTS: • Performance parameters showed no major differences after digitalisation to CR or DR. • Transition from SFM to CR results in a higher mean glandular dose. • Transition from SFM to DR results in a lower mean glandular dose.


Assuntos
Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer , Mamografia/métodos , Programas de Rastreamento/métodos , Avaliação de Programas e Projetos de Saúde , Intensificação de Imagem Radiográfica/métodos , Idoso , Bélgica , Feminino , Humanos , Pessoa de Meia-Idade , Radiometria , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Phys Eng Sci Med ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634980

RESUMO

Monte Carlo simulations using patient CT images as input are the gold standard to perform patient-specific dosimetry. However, in standard clinical practice patient's CT images are limited to the reconstructed CT scan range. In this study, organ dose calculations were performed with ImpactMC for chest and cardiac CT using whole-body and anatomy-specific voxel models to estimate the accuracy of CT organ doses based on the latter model. When the 3D patient model is limited to the CT scan range, CT organ doses from Monte Carlo simulations are the most accurate for organs entirely in the field of view. For these organs only the radiation dose related to scatter from the rest of the body is not incorporated. For organs lying partially outside the field of view organ doses are overestimated by not accounting for the non-irradiated tissue mass. This overestimation depends strongly on the amount of the organ volume located outside the field of view. To get a more accurate estimation of the radiation dose to these organs, the ICRP reference organ masses and densities could form a solution. Except for the breast, good agreement in dose was found for most organs. Voxel models generated from clinical CT examinations do not include the overscan in the z-direction. The availability of whole-body voxel models allowed to study this influence as well. As expected, overscan induces slightly higher organ doses.

14.
Health Phys ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38884587

RESUMO

ABSTRACT: Personal radiation protective equipment (PRPE) is prone to defects in the attenuating layers, resulting in inadequate protection. Hence, quality control (QC) of PRPE is needed to assess its integrity. Unfortunately, QC of PRPE is laborious and time consuming. This study aimed to predict the QC outcome of PRPE without x-ray imaging based on readily available predictors. PRPE QC data of a general hospital from 2018 to 2023 was used for both prediction models based on logistic regression and random forests (RF). The data were divided into a training set containing all data from 2018 to 2022 and a holdout set containing the data from 2023. The predictors were brand, age, size, type, visual defects, and department. The prediction performances were compared using confusion matrices and visualized with receiver operating characteristic (ROC) curves. Prediction accuracies of at least 80% were achieved. Further model tuning especially improved the RF model to a precision up to 97% with a sensitivity of 80% and specificity of 86%. All predictors, except visual defects, significantly impacted the probability of passing. The predictor brand had the largest contribution to the predictive performance. The difference in pass probability between the best-performing and the worst-performing brand was 35.1%. The results highlight the potential of predicting PRPE QC outcome without x rays. The proposed prediction approach is a significant contribution to an effective QC strategy by reducing time consuming x-ray QC tests and focusing on garments with higher probability of being defective. Further research is recommended.

15.
Phys Med ; 121: 103344, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38593627

RESUMO

PURPOSE: To validate the performance of computer-aided detection (CAD) and volumetry software using an anthropomorphic phantom with a ground truth (GT) set of 3D-printed nodules. METHODS: The Kyoto Kaguku Lungman phantom, containing 3D-printed solid nodules including six diameters (4 to 9 mm) and three morphologies (smooth, lobulated, spiculated), was scanned at varying CTDIvol levels (6.04, 1.54 and 0.20 mGy). Combinations of reconstruction algorithms (iterative and deep learning image reconstruction) and kernels (soft and hard) were applied. Detection, volumetry and density results recorded by a commercially available AI-based algorithm (AVIEW LCS + ) were compared to the absolute GT, which was determined through µCT scanning at 50 µm resolution. The associations between image acquisition parameters or nodule characteristics and accuracy of nodule detection and characterization were analyzed with chi square tests and multiple linear regression. RESULTS: High levels of detection sensitivity and precision (minimal 83 % and 91 % respectively) were observed across all acquisitions. Neither reconstruction algorithm nor radiation dose showed significant associations with detection. Nodule diameter however showed a highly significant association with detection (p < 0.0001). Volumetric measurements for nodules > 6 mm were accurate within 10 % absolute range from volumeGT, regardless of dose and reconstruction. Nodule diameter and morphology are major determinants of volumetric accuracy (p < 0.001). Density assignment was not significantly influenced by any parameters. CONCLUSIONS: Our study confirms the software's accurate performance in nodule volumetry, detection and density characterization with robustness for variations in CT imaging protocols. This study suggests the incorporation of similar phantom setups in quality assurance of CAD tools.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Impressão Tridimensional , Software
16.
Int J Radiat Biol ; 100(2): 236-247, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37819795

RESUMO

Introduction: In radiology, low X-ray energies (<140 keV) are used to obtain an optimal image while in radiotherapy, higher X-ray energies (MeV) are used to eradicate tumor tissue. In radiation research, both these X-ray energies being used to extrapolate in vitro research to clinical practice. However, the energy deposition of X-rays depends on their energy spectrum, which might lead to changes in biological response. Therefore, this study compared the DNA damage response (DDR) in peripheral blood lymphocytes (PBLs) exposed to X-rays with varying beam quality, mean photon energy (MPE) and dose rate.Methods: The DDR was evaluated in peripheral blood lymphocytes (PBLs) by the É£-H2AX foci assay, the cytokinesis-block micronucleus assay and an SYTOX-based cell death assay, combined with specific cell death inhibitors. Cell cultures were irradiated with a 220 kV X-ray research cabinet (SARRP, X-Strahl) or a 6 MV X-ray linear accelerator (Elekta Synergy). Three main physical parameters were investigated: beam quality (V), MPE (eV) and dose rate (Gy/min). Additional copper (Cu) filtration caused variation in the MPE (78 keV, 94 keV, 118 keV) at SARRP; dose rates were varied by adjusting tube current for 220 kV X-rays (0.33-3 Gy/min) or water-phantom depth in the 6 MV set-up (3-6 Gy/min).Results: The induction of chromosomal damage and initial (30 min) DNA double-stranded breaks (DSBs) were significantly higher for 220 kV X-rays compared to 6 MV X-rays, while cell death induction was similar. Specific cell death inhibitors for apoptosis, necroptosis and ferroptosis were not capable of blocking cell death after irradiation using low or high-energy X-rays. Additional Cu filtration increased the MPE, which significantly decreased the amount of chromosomal damage and DSBs. Within the tested ranges no specific effects of dose rate variation were observed.Conclusion: The DDR in PBLs is influenced by the beam quality and MPE. This study reinforces the need for consideration and inclusion of all physical parameters in radiation-related studies.


Assuntos
Dano ao DNA , Linfócitos , Raios X , Radiografia , Linfócitos/efeitos da radiação , Reparo do DNA , Relação Dose-Resposta à Radiação
17.
Catheter Cardiovasc Interv ; 82(4): E419-27, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23420705

RESUMO

OBJECTIVES: The purpose of this study was to assess patient-specific organ doses and cancer risk with 3D-rotational acquisitions versus the current standard of multiple single-plane coronary angiography (CA). BACKGROUND: Catheter-based CA remains one of the most commonly performed diagnostic invasive procedures delivering a relatively high radiation dose to the patient. With the introduction of flat-panel technology, three-dimensional rotational angiography became an alternative for the conventional two-dimensional angiography. However, limited information is available on the difference in patient radiation exposure with both acquisition techniques. METHODS: Eighty adult patients (45 males, age 38-93 years) were randomly assigned to the rotational or standard angiography group. Exposure parameters were registered and skin dose distribution was measured during the procedure. Patient-specific organ doses and related cancer risks were assessed with dedicated software. RESULTS: Rotational angiograms were associated with 33% lower KAP-values (decrease from 49.99 Gycm(2) to 33.37 Gycm(2), P < 0.001). A significant (P < 0.001) lower peak skin dose was measured with rotational acquisitions (80 mGy, median) versus planar imaging (172 mGy, median). Moreover, the skin dose was smoothed over the whole chest of the patient. Contrast medium consumption decreased from 104 mL to 73 mL (P < 0.001) with the use of 3D-imaging. The reduction in radiation exposure resulted in a corresponding decrease of organ doses. The latter contributed to an overall cancer risk reduction of 21% for males and 50% for females. CONCLUSIONS: The current study demonstrates that in CA radiation risk reduction is feasible by using a rotational acquisition technique.


Assuntos
Cineangiografia/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica , Cineangiografia/efeitos adversos , Meios de Contraste , Angiografia Coronária/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/prevenção & controle , Segurança do Paciente , Valor Preditivo dos Testes , Monitoramento de Radiação/métodos , Medição de Risco , Fatores de Risco , Pele/efeitos da radiação
18.
EJNMMI Phys ; 10(1): 32, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37227561

RESUMO

BACKGROUND: While diagnostic reference levels (DRLs) are well-established for the radiopharmaceutical part, published DRLs for the CT component of positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT) are limited. This systematic review and meta-analysis provides an overview of the different objectives of CT in hybrid imaging and summarizes reported CT dose values for the most common PET/CT and SPECT/CT examinations. Also, an overview of already proposed national DRLs is given. METHODS: A systematic literature search was performed to identify original articles reporting CT dose index volume (CTDIvol), dose-length product (DLP) and/or national DRLs for the most frequently performed PET/CT and/or SPECT/CT examinations. Data were grouped according to the clinical objective: diagnostic (D-CT), anatomical localisation (AL-CT) or attenuation correction (AC-CT) CT. Random-effects meta-analyses were conducted. RESULTS: Twenty-seven articles were identified of which twelve reported national DRLs. For brain and tumour PET/CT imaging, CTDIvol and DLP values were higher for a D-CT (brain: 26.7 mGy, 483 mGy cm; tumour: 8.8 mGy, 697 mGy cm) than for an AC/AL-CT (brain: 11.3 mGy, 216 mGy cm; tumour: 4.3 mGy, 419 mGy cm). Similar conclusions were found for bone and parathyroid SPECT/CT studies: D-CT (bone: 6.5 mGy, 339 mGy cm; parathyroid: 15.1 mGy, 347 mGy cm) results in higher doses than AL-CT (bone: 3.8 mGy, 156 mGy cm; parathyroid: 4.9 mGy, 166 mGy cm). For cardiac (AC-CT), mIBG/octreotide, thyroid and post-thyroid ablation (AC/AL-CT) SPECT/CT pooled mean CTDIvol (DLP) values were 1.8 mGy (33 mGy cm), 4.6 mGy (208 mGy cm), 3.1 mGy (105 mGy cm) and 4.6 mGy (145 mGy cm), respectively. For all examinations, high variability in nuclear medicine practice was observed. CONCLUSION: The large variation in CT dose values and national DRLs highlights the need for optimisation in hybrid imaging and justifies the clinical implementation for nuclear medicine specific DRLs.

19.
Front Cardiovasc Med ; 10: 1292039, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38274314

RESUMO

Introduction: Imaging fusion technology is promising as it is radiation and contrast sparing. Herein, we compare conventional biplane angiography to multimodality image fusion with live fluoroscopy using two-dimensional (2D)-three-dimensional (3D) registration (MMIF2D-3D) and assess MMIF2D-3D impact on radiation exposure and contrast volume during cardiac catheterization of patients with congenital heart disease (CHD). Methods: We matched institutional MMIF2D-3D procedures and controls according to patient characteristics (body mass index, age, and gender) and the seven procedure-type subgroups. Then, we matched the number of tests and controls per subgroup using chronological ordering or propensity score matching. Subsequently, we combined the matched subgroups into larger subgroups of similar procedure type, keeping subgroups with at least 10 test and 10 control cases. Air kerma (AK) and dose area product (DAP) were normalized by body weight (BW), product of body weight and fluoroscopy time (BW × FT), or product of body weight and number of frames (BW × FR), and stratified by acquisition plane and irradiation event type (fluoroscopy or acquisition). Three senior interventionists evaluated the relevance of MMIF2D-3D (5-point Likert scale). Results: The Overall group consisted of 54 MMIF2D-3D cases. The combined and matched subgroups were pulmonary artery stenting (StentPUL), aorta angioplasty (PlastyAO), pulmonary artery angioplasty (PlastyPUL), or a combination of the latter two (Plasty). The FT of the lateral plane reduced significantly by 69.6% for the Overall MMIF2D-3D population. AKBW and DAPBW decreased, respectively, by 43.9% and 39.3% (Overall group), 49.3% and 54.9% (PlastyAO), and 36.7% and 44.4% for the Plasty subgroup. All the aforementioned reductions were statistically significant except for DAPBW in the Overall and Plasty (sub)groups. The decrease of AKBW and DAPBW in the StentPUL and PlastyPUL subgroups was not statistically significant. The decrease in the median values of the weight-normalized contrast volume (CMCBW) in all five subgroups was not significant. Cardiologists considered MMIF2D-3D very useful with a median score of 4. Conclusion: In our institution, MMIF2D-3D overall enabled significant AKBW reduction during the catheterization of CHD patients and was mainly driven by reduced FT in the lateral plane. We observed significant AKBW reduction in the Plasty and PlastyAO subgroups and DAPBW reduction in the PlastyAO subgroup. However, the decrease in CMCBW was not significant.

20.
Insights Imaging ; 14(1): 55, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37005914

RESUMO

PURPOSE: To analyse the existing radiation protection (RP) education and training (E&T) capabilities in the European Union and identify associated needs, problems and challenges. METHOD: An online survey was disseminated via the EURAMED Rocc-n-Roll consortium network and prominent medical societies in the field of radiological research. The survey sections analyse the RP E&T during undergraduate, residency/internship and continuous professional development; RP E&T problems and legal implementation. Differences were analysed by European geographic regions, profession, years of professional experience and main area of practice/research. RESULTS: The majority of the 550 respondents indicated that RP topics are part of undergraduate curricula in all courses for their profession and country (55%); however, hands-on practical training is not included according to 30% of the respondents. The lack of E&T, practical aspects in current E&T, and mandatory continuing E&T were considered the major problems. The legal requirement that obtained higher implementation score was the inclusion of the practical aspects of medical radiological procedures on education (86%), and lower score was obtained for the inclusion of RP E&T on medical and dental school curriculums (61%). CONCLUSIONS: A heterogeneity in RP E&T during undergraduate, residency/internship and continuous professional development is evident across Europe. Differences were noted per area of practice/research, profession, and European geographic region. A large variation in RP E&T problem rating was also obtained.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA