Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
World J Gastrointest Surg ; 16(2): 616-621, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38463358

RESUMO

BACKGROUND: The overlap of imaging manifestations among distinct splenic lesions gives rise to a diagnostic dilemma. Consequently, a definitive diagnosis primarily relies on histological results. The ultrasound (US)-guided coaxial core needle biopsy (CNB) not only procures sufficient tissue to help clarify the diagnosis, but reduces the incidence of puncture-related complications. CASE SUMMARY: A 41-year-old female, with a history of pulmonary tuberculosis, was admitted to our hospital with multiple indeterminate splenic lesions. Gray-scale ultrasonography demonstrated splenomegaly with numerous well-defined hypoechoic masses. Abdominal contrast-enhanced computed tomography (CT) showed an enlarged spleen with multiple irregular-shaped, peripherally enhancing, hypodense lesions. Positron emission CT revealed numerous abnormal hyperglycemia foci. These imaging findings strongly indicated the possibility of infectious disease as the primary concern, with neoplastic lesions requiring exclusion. To obtain the precise pathological diagnosis, the US-guided coaxial CNB of the spleen was carried out. The patient did not express any discomfort during the procedure. CONCLUSION: Percutaneous US-guided coaxial CNB is an excellent and safe option for obtaining precise splenic tissue samples, as it significantly enhances sample yield for exact pathological analysis with minimum trauma to the spleen parenchyma and surrounding tissue.

2.
Acta Biomater ; 173: 36-50, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37939816

RESUMO

The ablation effect of focused ultrasound (FUS) has played an increasingly important role in the biomedical field over the past decades, and its non-invasive features have great advantages, especially for clinical diseases where surgical treatment is not available or appropriate. Recently, rapid advances in the adjustable morphology, enzyme-mimetic activity, and biostability of sono-activated materials have significantly promoted the medical application of FUS ablation. However, a systematic review of sono-activated materials based on FUS ablation is not yet available. This progress review focuses on the recent design, fundamental principles, and applications of sono-activated materials in the FUS ablation biomedical field. First, the different ablation mechanisms and the key factors affecting ablation are carefully determined. Then, the design of sono-activated materials with high FUS ablation efficiencies is comprehensively discussed. Subsequently, the representative biological applications are summarized in detail. Finally, the primary challenges and future perspectives are also outlined. We believe this timely review will provide key information and insights for further exploration of focused ultrasound ablation and new inspiration for designing future sono-activated materials. STATEMENT OF SIGNIFICANCE: The ablation effect of focused ultrasound (FUS) has played an increasingly important role in the biomedical field over the past decades. However, there are also some challenges of FUS ablation, such as skin burns, tumour recurrence after thermal ablation, and difficulty in controlling cavitation ablation. The rapid advance in adjustable morphology, enzyme-mimetic activity, and biostability of sono-activated materials has significantly promoted the medical application of FUS ablation. However, the systematic review of sono-activated materials based on FUS ablation is not yet available. This progress review focuses on the recent design, fundamental principles, and applications in the FUS ablation biomedical field of sono-activated materials. We believe this timely review will provide key information and insights for further exploration of FUS ablation.


Assuntos
Hipertermia Induzida , Neoplasias , Humanos
3.
Insights Imaging ; 15(1): 44, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353807

RESUMO

OBJECTIVES: To develop and compare noninvasive models for differentiating between combined hepatocellular-cholangiocarcinoma (cHCC-CCA) and HCC based on serum tumor markers, contrast-enhanced ultrasound (CEUS), and computed tomography (CECT). METHODS: From January 2010 to December 2021, patients with pathologically confirmed cHCC-CCA or HCC who underwent both preoperative CEUS and CECT were retrospectively enrolled. Propensity scores were calculated to match cHCC-CCA and HCC patients with a near-neighbor ratio of 1:2. Two predicted models, a CEUS-predominant (CEUS features plus tumor markers) and a CECT-predominant model (CECT features plus tumor markers), were constructed using logistic regression analyses. Model performance was evaluated by the area under the curve (AUC), sensitivity, specificity, and accuracy. RESULTS: A total of 135 patients (mean age, 51.3 years ± 10.9; 122 men) with 135 tumors (45 cHCC-CCA and 90 HCC) were included. By logistic regression analysis, unclear boundary in the intratumoral nonenhanced area, partial washout on CEUS, CA 19-9 > 100 U/mL, lack of cirrhosis, incomplete tumor capsule, and nonrim arterial phase hyperenhancement (APHE) volume < 50% on CECT were independent factors for a diagnosis of cHCC-CCA. The CECT-predominant model showed almost perfect sensitivity for cHCC-CCA, unlike the CEUS-predominant model (93.3% vs. 55.6%, p < 0.001). The CEUS-predominant model showed higher diagnostic specificity than the CECT-predominant model (80.0% vs. 63.3%; p = 0.020), especially in the ≤ 5 cm subgroup (92.0% vs. 70.0%; p = 0.013). CONCLUSIONS: The CECT-predominant model provides higher diagnostic sensitivity than the CEUS-predominant model for CHCC-CCA. Combining CECT features with serum CA 19-9 > 100 U/mL shows excellent sensitivity. CRITICAL RELEVANCE STATEMENT: Combining lack of cirrhosis, incomplete tumor capsule, and nonrim arterial phase hyperenhancement (APHE) volume < 50% on CECT with serum CA 19-9 > 100 U/mL shows excellent sensitivity in differentiating cHCC-CCA from HCC. KEY POINTS: 1. Accurate differentiation between cHCC-CCA and HCC is essential for treatment decisions. 2. The CECT-predominant model provides higher accuracy than the CEUS-predominant model for CHCC-CCA. 3. Combining CECT features and CA 19-9 levels shows a sensitivity of 93.3% in diagnosing cHCC-CCA.

4.
Front Oncol ; 13: 1245686, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38023257

RESUMO

Objective: This study aimed to develop and validate a nomogram based on ultrasonographic features and clinical indicators to differentiate mass-forming intrahepatic cholangiocarcinoma (MF-ICC) from hepatic metastatic colorectal adenocarcinoma. Materials and methods: A total of 343 patients with pathologically confirmed MF-ICC or metastatic colorectal adenocarcinoma were enrolled between October 2018 and July 2022. Patients were randomly assigned to training and validation sets at a ratio of 7:3. Preoperative ultrasound features and clinical indicators were retrieved. Univariate logistic regression analysis was employed to select relevant features. Multivariate logistic regression analysis was used to establish a predictive model, which was presented as a nomogram in training sets. The model's performance was assessed in terms of discrimination, calibration, and clinical usefulness. Results: The study included 169 patients with MF-ICC and 174 with liver metastatic colorectal adenocarcinoma, assigned to training (n=238) and validation (n=105) cohorts. The nomogram incorporated ultrasound features (tumor size, lesion number, echogenicity, tumor necrosis, and rim arterial phase hyperenhancement) and clinical information (serum levels of CEA, CA19-9, CA125). The nomogram demonstrated promising performance in differentiating these two entities in both training and validation sets, with an AUC value of 0.937 (95%CI: 0.907,0.969) and 0.916 (95%CI: 0.863,0.968), respectively. The Hosmer-Lemeshow test and calibration curves confirmed good consistency between predictions and observations. Additionally, decision curve analysis confirmed the nomogram's high clinical practicability. Conclusion: The nomogram based on ultrasound features and clinical indicators demonstrated good discrimination performance in differentiating MF-ICC from metastatic colorectal adenocarcinoma, which may enhance clinical decision-making process in managing these challenging diagnostic scenarios.

5.
Chin Med J (Engl) ; 136(17): 2028-2036, 2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-36728948

RESUMO

BACKGROUND: Patients with mass-forming pancreatitis (MFP) or pancreatic ductal adenocarcinoma (PDAC) presented similar clinical symptoms, but required different treatment approaches and had different survival outcomes. This meta-analysis aimed to compare the diagnostic performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) in differentiating MFP from PDAC. METHODS: A literature search was performed in the PubMed, EMBASE (Ovid), Cochrane Library (CENTRAL), China National Knowledge Infrastructure (CNKI), Weipu (VIP), and WanFang databases to identify original studies published from inception to August 20, 2021. Studies reporting the diagnostic performances of CEUS and CECT for differentiating MFP from PDAC were included. The meta-analysis was performed with Stata 15.0 software. The outcomes included the pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR), and summary receiver operating characteristic (SROC) curves of CEUS and CECT. Meta-regression was conducted to investigate heterogeneity. Bayesian network meta-analysis was conducted to indirectly compare the overall diagnostic performance. RESULTS: Twenty-six studies with 2115 pancreatic masses were included. The pooled sensitivity and specificity of CEUS for MFP were 82% (95% confidence interval [CI], 73%-88%; I2  = 0.00%) and 95% (95% CI, 90%-97%; I2  = 63.44%), respectively; the overall +LR, -LR, and DOR values were 15.12 (95% CI, 7.61-30.01), 0.19 (95% CI, 0.13-0.29), and 78.91 (95% CI, 30.94-201.27), respectively; and the area under the SROC curve (AUC) was 0.90 (95% CI, 0.87-92). However, the overall sensitivity and specificity of CECT were 81% (95% CI, 75-85%; I2  = 66.37%) and 94% (95% CI, 90-96%; I2  = 74.87%); the overall +LR, -LR, and DOR values were 12.91 (95% CI, 7.86-21.20), 0.21 (95% CI, 0.16-0.27), and 62.53 (95% CI, 34.45-113.51), respectively; and, the SROC AUC was 0.92 (95% CI, 0.90-0.94). The overall diagnostic accuracy of CEUS was comparable to that of CECT for the differential diagnosis of MFP and PDAC (relative DOR 1.26, 95% CI [0.42-3.83], P  > 0.05). CONCLUSIONS: CEUS and CECT have comparable diagnostic performance for differentiating MFP from PDAC, and should be considered as mutually complementary diagnostic tools for suspected focal pancreatic lesions.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Pancreatite , Humanos , Meios de Contraste , Teorema de Bayes , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Sensibilidade e Especificidade , Pancreatite/diagnóstico por imagem , Ultrassonografia/métodos , Neoplasias Pancreáticas
6.
J Evid Based Med ; 16(2): 103-106, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37264750

RESUMO

Objective Contrast-enhanced ultrasound offers numerous potential applications in diagnostic and interventional radiology. However, systematic studies on the status of clinical studies are limited. Hence, the aim of this study was to analyze the characteristics of registered contrast-enhanced ultrasound studies on ClinicalTrials.gov and identify features associated with early discontinuation and results reporting. METHODS: A data set containing all contrast-enhanced ultrasound clinical studies from ClinicalTrials.gov registered was downloaded. Then, a cross-sectional descriptive study of clinical contrast-enhanced ultrasound studies was conducted. Cox and logistic regression of early discontinuation and reported results, respectively, were also performed. RESULTS: A total of 225 studies were identified; 174 were interventional and 51 were observational. Regarding the outcomes measure, 175 (77.78%) were diagnosis-oriented, and the remaining 50 (22.22%) were interventional radiology studies. The most common regions of interest were abdominal (56%), superficial (14.22%), or vascular (7.11%) organs. As of the contrast agents, SonoVue/Lumason (39.11%) was most frequently used, followed by Definity (20.89%) and Sonazoid (8.89%). Of all contrast-enhanced ultrasound studies, 32 (14.22%) were discontinued early, and 29 (12.89%) completed studies reported their results. Cox regression analysis revealed that a large sample size and US registration were factors reducing early discontinuation risk. Among completed studies, factors associated with reported results were industry funding and US registration. CONCLUSION: The findings suggest that the number of contrast-enhanced ultrasound studies has grown over time, but is still small. Developing new advancements in contrast-enhanced ultrasound will require a concerted effort to increase the quality and quantity of clinical studies in this field.


Assuntos
Meios de Contraste , Projetos de Pesquisa , Estudos Transversais , Estudos Observacionais como Assunto , Tamanho da Amostra , Humanos
7.
World J Gastroenterol ; 29(17): 2534-2550, 2023 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-37213404

RESUMO

In the world, nonalcoholic fatty liver disease (NAFLD) accounts for majority of diffuse hepatic diseases. Notably, substantial liver fat accumulation can trigger and accelerate hepatic fibrosis, thus contributing to disease progression. Moreover, the presence of NAFLD not only puts adverse influences for liver but is also associated with an increased risk of type 2 diabetes and cardiovascular diseases. Therefore, early detection and quantified measurement of hepatic fat content are of great importance. Liver biopsy is currently the most accurate method for the evaluation of hepatic steatosis. However, liver biopsy has several limitations, namely, its invasiveness, sampling error, high cost and moderate intraobserver and interobserver reproducibility. Recently, various quantitative imaging techniques have been developed for the diagnosis and quantified measurement of hepatic fat content, including ultrasound- or magnetic resonance-based methods. These quantitative imaging techniques can provide objective continuous metrics associated with liver fat content and be recorded for comparison when patients receive check-ups to evaluate changes in liver fat content, which is useful for longitudinal follow-up. In this review, we introduce several imaging techniques and describe their diagnostic performance for the diagnosis and quantified measurement of hepatic fat content.


Assuntos
Diabetes Mellitus Tipo 2 , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Diabetes Mellitus Tipo 2/patologia , Reprodutibilidade dos Testes , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Biópsia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA