Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anesthesiology ; 127(2): 284-292, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28719527

RESUMO

BACKGROUND: Pupillometry has shown promising results for assessing nociception in anesthetized patients. However, its benefits in clinical practice are not demonstrated. The aim of this prospective randomized study was to evaluate the impact of intraoperative pupillometry monitoring on perioperative opioid consumption in major gynecologic surgery. METHODS: After receiving ethics committee approval and written consent of patients, American Society of Anesthesiologists status I to II women undergoing gynecologic surgery were included in this single-blinded, prospective, parallel-arm randomized study. General anesthesia was standardized with propofol-remifentanil target-controlled infusion. Patients were randomly assigned into two groups. In the pupillometry group, remifentanil administration was guided by pupillary diameter changes. In the standard group, remifentanil administration was left to the discretion of the anesthesiologist. The primary outcome was intraoperative remifentanil consumption. RESULTS: Fifty-five patients were analyzed. Remifentanil consumption was markedly decreased in the pupillometry group (3.8 [3.4 to 4.8 µg · kg · h] vs. 7.9 µg · kg · h [6.5 to 9.0 µg · kg · h] in the standard group; difference = 4.2 µg · kg · h [95% CI, 3.0 to 5.3 µg · kg · h]; P < 0.001). Cumulative 0- to 12-h morphine consumption was reduced in the pupillometry group (two-way repeated measures ANOVA 0.3 ± 0.1 vs. 0.4 ± 0.2 mg/kg; P = 0.048). A telephone survey 3 months after surgery revealed that 15 of 29 patients in the standard group still experienced procedure-related pain versus 3 of 23 in the pupillometry group (chi-square P = 0.037). No adverse events associated with pupillometry were observed during the study. CONCLUSIONS: The use of pupillometry to guide intraoperative analgesia reduced intraoperative remifentanil consumption and postoperative morphine requirements. The possible consequences of decreasing intraoperative remifentanil in terms of chronic pain require further investigation.


Assuntos
Analgésicos Opioides/administração & dosagem , Procedimentos Cirúrgicos em Ginecologia , Monitorização Intraoperatória/métodos , Piperidinas/administração & dosagem , Pupila/efeitos dos fármacos , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Remifentanil , Método Simples-Cego
2.
Intensive Care Med ; 39(1): 93-100, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22990869

RESUMO

PURPOSE: In stable ventilatory and metabolic conditions, changes in end-tidal carbon dioxide (EtCO(2)) might reflect changes in cardiac index (CI). We tested whether EtCO(2) detects changes in CI induced by volume expansion and whether changes in EtCO(2) during passive leg raising (PLR) predict fluid responsiveness. We compared EtCO(2) and arterial pulse pressure for this purpose. METHODS: We included 65 patients [Simplified Acute Physiology Score (SAPS) II = 57 ± 19, 37 males, under mechanical ventilation without spontaneous breathing, 15 % with chronic obstructive pulmonary disease, baseline CI = 2.9 ± 1.1 L/min/m(2)] in whom a fluid challenge was decided due to circulatory failure and who were monitored by an expiratory-CO(2) sensor and a PiCCO2 device. In all patients, we measured arterial pressure, EtCO(2), and CI before and after a fluid challenge. In 40 patients, PLR was performed before fluid administration. The PLR-induced changes in arterial pressure, EtCO(2), and CI were recorded. RESULTS: Considering the whole population, the fluid-induced changes in EtCO(2) and CI were correlated (r (2) = 0.45, p = 0.0001). Considering the 40 patients in whom PLR was performed, volume expansion increased CI ≥ 15 % in 21 "volume responders." A PLR-induced increase in EtCO(2) ≥ 5 % predicted a fluid-induced increase in CI ≥ 15 % with sensitivity of 71 % (95 % confidence interval: 48-89 %) and specificity of 100 (82-100) %. The prediction ability of the PLR-induced changes in CI was not different. The area under the receiver-operating characteristic (ROC) curve for the PLR-induced changes in pulse pressure was not significantly different from 0.5. CONCLUSION: The changes in EtCO(2) induced by a PLR test predicted fluid responsiveness with reliability, while the changes in arterial pulse pressure did not.


Assuntos
Pressão Arterial , Dióxido de Carbono/análise , Débito Cardíaco/fisiologia , Extremidade Inferior/irrigação sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Sensibilidade e Especificidade , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA