Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Microbiol ; 59(9): e0123121, 2021 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-34166066

RESUMO

Longitudinal studies assessing durability of the anti-severe acute respiratory syndrome coronavirus 2 (anti-SARS-CoV-2) humoral immune response have generated conflicting results. This has been proposed to be due to differences in patient populations, the lack of standardized methodologies, and the use of assays that measure distinct aspects of the humoral response. SARS-CoV-2 antibodies were serially measured in sera from a cohort of 44 well-characterized convalescent plasma donors over 120 days post-COVID-19 symptom onset, utilizing eight assays, which varied according to antigen source, the detected antibody isotype, and the activity measured (i.e., binding, blocking, or neutralizing). While the majority of assays demonstrated a gradual decline in antibody titers over the course of 120 days, the two electrochemiluminescence immunoassay Roche assays (Roche Diagnostics Elecsys anti-SARS-CoV-2 [qualitative, nucleocapsid based] and Roche Diagnostics Elecsys anti-SARS-CoV-2 S [semiquantitative, spike based]), which utilize dual-antigen binding for antibody detection, demonstrated stable and/or increasing antibody titers over the study period. This study is among the first to assess longitudinal, rather than cross-sectional, SARS-CoV-2 antibody profiles among convalescent COVID-19 patients, primarily using commercially available serologic assays with Food and Drug Administration emergency use authorization. We show that SARS-CoV-2 antibody detection is dependent on the serologic method used, which has implications for future assay utilization and clinical value.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/terapia , Estudos Transversais , Humanos , Imunização Passiva , Cinética , Sensibilidade e Especificidade , Soroterapia para COVID-19
2.
Ther Drug Monit ; 43(5): 696-700, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734211

RESUMO

BACKGROUND: The optimal dosing and monitoring of vancomycin has been largely debated for decades, with key guideline changes for recommended monitoring in 2009 and 2020. Current and past practices for pharmacokinetic dose optimization use serum drug assays to guide dose adjustment to effectively balance efficacy and the risks of toxicity. These assays detect both bound and unbound serum concentrations. Vancomycin is believed to be 50%-55% protein bound in most cases; however, some variability in this parameter has been previously published. The authors report 2 cases of abnormal vancomycin pharmacokinetics discovered based on unexpected serum levels during routine clinical care. METHODS: Unexpected vancomycin levels, observed during clinical care for 2 separate patients, were further evaluated to determine the source of the abnormal pharmacokinetics. In case 1, serial dilution was performed to assure that assay interference was not associated with the significant elevation (>100 mg/L). In both cases, samples were filtered using a Millipore Centrifree 30 KDa centrifugal filter to separate bound vancomycin, with a Protein G spin kit used to bind IgG and remove IgG complexes from the patient sample. In case 2, a polyethylene glycol precipitation was also performed to precipitate large-molecular-weight complexes. RESULTS: In both cases, laboratory analysis revealed abnormal vancomycin protein-binding profiles with macromolecular complex formation. Immunoglobulin G played a role in the macrocomplex in both patients. CONCLUSIONS: In cases of unusual or unexpected vancomycin pharmacokinetics in the absence of renal dysfunction, an abnormal protein-binding profile should be considered. Bound vancomycin may yield elevated serum levels, leading to poorly informed dose adjustments and risk for treatment failure. Given implications for therapeutic drug monitoring and unknown impacts on efficacy and toxicity, further investigations into population incidence and risk factors for abnormal protein binding of vancomycin are warranted.


Assuntos
Antibacterianos , Vancomicina , Antibacterianos/farmacocinética , Monitoramento de Medicamentos , Humanos , Vancomicina/farmacocinética
3.
Clin Chem Lab Med ; 59(6): 1013-1023, 2021 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-33554525

RESUMO

OBJECTIVES: Results can vary between different free thyroxine (FT4) assays; global standardization would improve comparability of results between laboratories, allowing development of common clinical decision limits in evidence-based guidelines. CONTENT: We summarize the path to standardization of FT4 assays, and challenges associated with FT4 testing in special populations, including the need for collaborative efforts toward establishing population-specific reference intervals. The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests has undertaken FT4 immunoassay method comparison and recalibration studies and developed a reference measurement procedure that is currently being validated. Further studies are needed to establish common reference intervals/clinical decision limits. Standardization of FT4 assays will change test results substantially; therefore, a major education program will be required to ensure stakeholders are aware of the benefits of FT4 standardization, planned transition procedure, and potential clinical impact of the changes. Assay recalibration by manufacturers and approval process simplification by regulatory authorities will help minimize the clinical impact of standardization. SUMMARY: Significant progress has been made toward standardization of FT4 testing, but technical and logistical challenges remain. OUTLOOK: Collaborative efforts by manufacturers, laboratories, and clinicians are required to achieve successful global standardization of the FT4 assays.


Assuntos
Prova Pericial , Tiroxina , Humanos , Imunoensaio , Padrões de Referência , Valores de Referência , Testes de Função Tireóidea , Tireotropina
4.
Clin Chem Lab Med ; 57(8): 1192-1196, 2019 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-30753153

RESUMO

Background Heterophile antibody (HAb) interferences in immunoassays can cause falsely elevated hCG concentrations leading to incorrect diagnosis and treatments options. When results are not consistent with the clinical findings, hCG HAb interference investigation may be requested by the physician. A retrospective evaluation of the frequency of HAb interference was performed among cases of physician-requested investigations and the effectiveness of commercially available blocking reagents to detect HAb interference in two immunoassay systems was evaluated. Methods One hundred and thirteen physician requests for hCG HAb investigation from 2008 to 2017 were reviewed. The primary method used to measure hCG was the Beckman Coulter Access Total ßhCG (2008-2010) and the Roche Elecsys HCG+ß (2014-2017). HAb investigation included measurement by two immunoassays before and after treatment of samples with heterophile blocking reagents and serial dilution studies. Results Five cases of HAb and HAb-like interference were identified. The interference frequency was 6.7% for the Beckman assay and 2.9% for the Roche assay. The presence of HAb was detected using heterophile blocking reagents and an alternative method in three cases. The other two cases were detected due to discrepant results with an alternative method and non-linear serial dilutions (HAb-like). Conclusions HAb interference was observed in the Beckman and the Roche assays. The heterophile blocking reagents failed to detect 40% of interference cases. Blocking reagents should not solely be used for these investigations. Multiple strategies including the use of serial dilutions and using an alternative platform are critical when troubleshooting interferences in hCG immunoassays.


Assuntos
Anticorpos Heterófilos/análise , Gonadotropina Coriônica/análise , Ensaio de Imunoadsorção Enzimática , Anticorpos Heterófilos/imunologia , Gonadotropina Coriônica/imunologia , Humanos
5.
Clin Chem ; 62(6): 824-30, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27022069

RESUMO

BACKGROUND: We assessed the impact of clinical decision support (CDS) rules within the electronic health record for ionized calcium (iCa), serum magnesium (Mg), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in intensive care unit (ICU) inpatients at a large academic center. METHODS: A repeat order for measurement of iCa or Mg placed within 24 (iCa) or 48 (Mg) h of a previously nonactionable result, or additional orders for NT-proBNP beyond 1 within a single hospitalization, triggered a CDS pop-up alert showing the prior result and offering the opportunity to cancel the order or to place the order after entering an indication for repeat testing. The number of tests performed for each of these analytes and incidence of adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia were compared between the 90-day period before CDS implementation and two 90-day periods immediately following. RESULTS: iCa test volumes decreased by 48%, Mg by 39%, and NT-proBNP by 28% in the 90-day period immediately following implementation and remained decreased by 54%, 49%, and 22%, respectively, during the following 90-day period (all P values <0.0002). Adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia did not increase (all P-values >0.17). CONCLUSIONS: Implementation of CDS dramatically decreased repeat testing of iCa, Mg, and NT-proBNP without adversely impacting clinical outcomes in the ICU. Expansion of the rules from the ICU units to include the entire hospitalized patient population and expansion to additional analytes is expected to lead to further reductions in testing.


Assuntos
Cálcio/sangue , Sistemas de Apoio a Decisões Clínicas , Unidades de Terapia Intensiva , Magnésio/sangue , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Biomarcadores/sangue , Humanos
7.
Clin Chem ; 61(10): 1265-72, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26240296

RESUMO

BACKGROUND: The Kidney Disease Improving Global Outcomes (KDIGO) guideline recommends use of a cystatin C-based estimated glomerular filtration rate (eGFR) to confirm creatinine-based eGFR between 45 and 59 mL · min(-1) · (1.73 m(2))(-1). Prior studies have demonstrated that comorbidities such as solid-organ transplant strongly influence the relationship between measured GFR, creatinine, and cystatin C. Our objective was to evaluate the performance of cystatin C-based eGFR equations compared with creatinine-based eGFR and measured GFR across different clinical presentations. METHODS: We compared the performance of the CKD-EPI 2009 creatinine-based estimated GFR equation (eGFRCr) and the newer CKD-EPI 2012 cystatin C-based equations (eGFRCys and eGFRCr-Cys) with measured GFR (iothalamate renal clearance) across defined patient populations. Patients (n = 1652) were categorized as transplant recipients (n = 568 kidney; n = 319 other organ), known chronic kidney disease (CKD) patients (n = 618), or potential kidney donors (n = 147). RESULTS: eGFRCr-Cys showed the most consistent performance across different clinical populations. Among potential kidney donors without CKD [stage 2 or higher; eGFR >60 mL · min(-1) · (1.73 m(2))(-1)], eGFRCys and eGFRCr-Cys demonstrated significantly less bias than eGFRCr; however, all 3 equations substantially underestimated GFR when eGFR was <60 mL · min(-1) · (1.73 m(2))(-1). Among transplant recipients with CKD stage 3B or greater [eGFR <45 mL · min(-1) · (1.73 m(2))(-1)], eGFRCys was significantly more biased than eGFRCr. No clear differences in eGFR bias between equations were observed among known CKD patients regardless of eGFR range or in any patient group with a GFR between 45 and 59 mL · min(-1) · (1.73 m(2))(-1). CONCLUSIONS: The performance of eGFR equations depends on patient characteristics that are readily apparent on presentation. Among the 3 CKD-EPI equations, eGFRCr-Cys performed most consistently across the studied patient populations.


Assuntos
Creatinina/sangue , Cistatina C/sangue , Taxa de Filtração Glomerular , Insuficiência Renal Crônica/sangue , Adulto , Idoso , Algoritmos , Feminino , Humanos , Rim/patologia , Transplante de Rim , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/diagnóstico
8.
Semin Thromb Hemost ; 40(1): 115-20, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24381152

RESUMO

Warfarin dosing relies on accurate measurements of international normalized ratio (INR), which is calculated from the prothrombin time (PT), International Sensitivity Index international sensitivity index (ISI) of the thromboplastin, and the geometric mean of normal PT (MNPT). However, ISI assignments of certain reagent/instrument combinations are frequently unavailable, especially when the reagent and instrument are not from the same manufacturer. The effort to be in compliance with widely endorsed Clinical and Laboratory Standards Institute (CLSI) guidelines by locally verifying or assigning an ISI to an unsupported reagent/instrument combination is further hindered by the lack of US Food and Drug Administration (FDA)-approved certified plasmas designated for a particular reagent/instrument combination. The objectives of the study include development of a process to verify/assign ISI and MNPT of a single thromboplastin reagent from one manufacturer across multiple instruments including several from another manufacturer and across several campuses of a single institution, the Mayo Clinic. In this study, RecombiPlasTin 2G (R2G), was evaluated on the ACL TOP 700 (IL), STA-R Evolution, STA Compact, and STA Satellite. Random normal donor samples (n = 25) were used to verify/assign MNPT. A subset of the normal donors (n = 8) and 13 warfarin pools (INR range: 1.3-3.9), created from stable warfarin patient plasma, were used for ISI verification/assignment. The manufacturer's assigned ISI was first verified on the ACL TOP 700 (reference method), then assigned on three unsupported instruments using orthogonal regression analysis. The MNPT and manufacturer assigned ISI (11.0, 0.95) were verified on the ACL TOP 700 and subsequently assigned on the STA-R Evolution (11.6, 1.04); STA Compact (11.5, 1.02); and STA Satellite (10.9, 0.99). Linear correlations of the INR results from all the four instruments demonstrated an r2 > 0.99. This process provides a reproducible approach to assigning ISIs on unsupported reagent/instrument combinations. Our data also confirm that ISIs of the same PT reagent differ significantly on different instruments, thus confirming the requirement for evaluations and validation of ISIs for different reagent/instrument combinations.


Assuntos
Anticoagulantes , Doadores de Sangue , Coeficiente Internacional Normatizado , Tempo de Protrombina , Varfarina , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacocinética , Feminino , Humanos , Coeficiente Internacional Normatizado/instrumentação , Coeficiente Internacional Normatizado/métodos , Coeficiente Internacional Normatizado/normas , Masculino , Tempo de Protrombina/instrumentação , Tempo de Protrombina/métodos , Tempo de Protrombina/normas , Estados Unidos , Varfarina/administração & dosagem , Varfarina/farmacocinética
9.
BJU Int ; 114(6b): E50-E55, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24712975

RESUMO

OBJECTIVE: To evaluate whether genetic correction using the genetic variants prostate-specific antigen (PSA)-single nucleotide polymorphisms (SNPs) could reduce potentially unnecessary and/or delayed biopsies in African-American men. SUBJECTS AND METHODS: We compared the genotypes of four PSA-SNPs between 964 Caucasian and 363 African-American men without known prostate cancer (PCa). We adjusted the PSA values based on an individual's PSA-SNP carrier status, and calculated the percentage of men that would meet commonly used PSA thresholds for biopsy (≥ 2.5 or ≥ 4.0 ng/mL) before and after genetic correction. Potentially unnecessary and delayed biopsies were defined as those men who were below and above the biopsy threshold after genetic correction, respectively. RESULTS: Overall, 349 (96.1%) and 354 (97.5%) African-American men had measured PSA levels <2.5 and <4.0 ng/mL. Genetic correction in African-American men did not avoid any potentially unnecessary biopsies, but resulted in a significant (P < 0.001) reduction in potentially delayed biopsies by 2.5% and 3.9%, based on the biopsy threshold level. CONCLUSIONS: There are significant differences in the influence of the PSA-SNPs between African-American and Caucasian men without known PCa, as genetic correction resulted in an increased proportion of African-American men crossing the threshold for biopsy. These results raise the question of whether genetic differences in PSA might contribute to delayed PCa diagnosis in African-American men.


Assuntos
Negro ou Afro-Americano/genética , Diagnóstico Tardio/prevenção & controle , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/estatística & dados numéricos , Antígeno Prostático Específico/genética , Neoplasias da Próstata/genética , Procedimentos Desnecessários , População Branca/genética , Idoso , Detecção Precoce de Câncer , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo de Nucleotídeo Único , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/patologia
10.
J Assist Reprod Genet ; 31(12): 1703-11, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25261352

RESUMO

PURPOSE: To determine the composition of commercially available protein supplements for embryo culture media and test if differences in protein supplement composition are biologically relevant in a murine model. METHODS: Amino acid, organic acid, ion and metal content were determined for 6 protein supplements: recombinant human albumin (AlbIX), human serum albumin (HSA and Buminate), and three complex protein supplements (SSS, SPS, LGPS). To determine if differences in the composition of these supplements are biologically relevant, mouse one-cell embryos were collected and cultured for 120 hours in each protein supplement in Global media at 5 and 20 % oxygen in an EmbryoScope time-lapse incubator. The compositions of six protein supplements were analyzed for concentrations of 39 individual amino acids, organic acids, ions and elements. Blastocyst development and cell cycle timings were calculated at 96-hours of culture and the experiments were repeated in triplicate. Blastocyst gene expression was analyzed. RESULTS: Recombinant albumin had the fewest undefined components , the lowest concentration of elements detected, and resulted in high blastocyst development in both 5 and 20 % oxygen. Buminate, LGPS and SPS had high levels of transition metals whereas SSS had high concentrations of amino acids. Pre-compaction mouse embryo development was delayed relative to embryos in AlbIX for all supplements and blastocyst formation was reduced in Buminate, SPS and SSS. CONCLUSIONS: The composition of protein supplements are variable, consisting of previously undescribed components. High concentrations of pro-oxidant transition metals were most notable. Blastocyst development was protein dependent and showed an interaction with oxygen concentration and pro-oxidant supplements.


Assuntos
Meios de Cultura/química , Técnicas de Cultura Embrionária/métodos , Desenvolvimento Embrionário/efeitos dos fármacos , Fertilização in vitro , Aminoácidos/química , Aminoácidos/isolamento & purificação , Animais , Blastocisto/efeitos dos fármacos , Embrião de Mamíferos , Humanos , Íons/química , Íons/isolamento & purificação , Metais/química , Metais/isolamento & purificação , Camundongos , Espécies Reativas de Oxigênio/metabolismo , Albumina Sérica/química , Albumina Sérica/farmacologia
11.
J Urol ; 189(5): 1697-701, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23246478

RESUMO

PURPOSE: Recent studies have identified genetic variants associated with increased serum prostate specific antigen concentrations and prostate cancer risk, raising the possibility of diagnostic bias. By correcting for the effects of these variants on prostate specific antigen, it may be possible to create a personalized prostate specific antigen cutoff to more accurately identify individuals for whom biopsy is recommended. Therefore, we determined how many men would continue to meet common biopsy criteria after genetic correction of their measured prostate specific antigen concentrations. MATERIALS AND METHODS: The genotypes of 4 single nucleotide polymorphisms previously associated with serum prostate specific antigen levels (rs2736098, rs10788160, rs11067228 and rs17632542) were determined in 964 healthy Caucasian volunteers without prostate cancer. Genetic correction of prostate specific antigen was performed by dividing an individual's prostate specific antigen value by his combined genetic risk. Analyses were used to compare the percentage of men who would meet commonly used biopsy thresholds (2.5 ng/ml or greater, or 4.0 ng/ml or greater) before and after genetic correction. RESULTS: Genetic correction of serum prostate specific antigen results was associated with a significantly decreased percentage of men meeting biopsy thresholds. Genetic correction could lead to a 15% or 20% relative reduction in the total number of biopsies using a biopsy threshold of 2.5 ng/ml or greater, or 4.0 ng/ml or greater, respectively. In addition, genetic correction could result in an 18% to 22% reduction in the number of potentially unnecessary biopsies and a 3% decrease in potentially delayed diagnoses. CONCLUSIONS: Our results suggest that 4 single nucleotide polymorphisms can be used to adjust a man's measured prostate specific antigen concentration and potentially delay or prevent unnecessary prostate biopsies in Caucasian men.


Assuntos
Variação Genética , Polimorfismo de Nucleotídeo Único , Antígeno Prostático Específico/sangue , Antígeno Prostático Específico/genética , Neoplasias da Próstata/sangue , Neoplasias da Próstata/genética , Idoso , Biópsia/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Medicina de Precisão , Neoplasias da Próstata/patologia , Procedimentos Desnecessários/estatística & dados numéricos
12.
Clin Chem Lab Med ; 51(5): 1007-25, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23633468

RESUMO

BACKGROUND: In a planned International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) worldwide study on reference intervals (RIs), a common panel of serum samples is to be measured by laboratories from different countries, and test results are to be compared through conversion using linear regression analysis. This report presents a validation study that was conducted in collaboration with four laboratories. METHODS: A panel composed of 80 sera was prepared from healthy individuals, and 45 commonly tested analytes (general chemistry, tumor markers, and hormones) were measured on two occasions 1 week apart in each laboratory. Reduced major-axis linear regression was used to convert reference limits (LL and UL). Precision was expressed as a ratio of the standard error of converted LL or UL to the standard deviation (SD) comprising RI (approx. 1/4 of the RI width corresponding to between-individual SD). The allowable and optimal levels of error for the SD ratio (SDR) were set as ≤0.250 and ≤0.125, respectively, in analogy to the common method of setting limits for analytical bias based on between-individual SD. RESULTS: The values for the calculated SDRs depended upon the distribution patterns of test results: skewness toward higher values makes SDRLL lower and SDRUL higher. However, the CV of the regression line slope, CV(b), is less affected by skewness. The average of SDRLL and SDRUL (aveSDR) correlates closely with CV(b) (r=0.995). The aveSDRs of ≤0.25 and ≤0.125 corresponds approximately to CV(b) values of ≤11% and ≤5.5%, respectively. For all results (i.e., n=80), conversion was allowable (optimal) in 98% (89%) of the analytes, as judged by CV(b). Resampling studies using random subsets of data with a data size (n) of 70 to 20 revealed that SDRs and CV(b) gradually increase with reduction of n, especially with n ≤30. CONCLUSIONS: CV(b) is a robust estimator for judging the convertibility of reference values among laboratories, even with a skewed distribution. Assuming 40 sera to be a practical size for the panel, reference values of 89% (80%) of analytes examined were made comparable by regression analysis with the allowable (optimal) level of precision.


Assuntos
Análise Química do Sangue/normas , Coleta de Amostras Sanguíneas/normas , Laboratórios/normas , Adulto , Idoso , Calibragem , Voluntários Saudáveis , Humanos , Modelos Lineares , Pessoa de Meia-Idade , Controle de Qualidade , Valores de Referência , Adulto Jovem
13.
Clin Biochem ; 121-122: 110685, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37972806

RESUMO

BACKGROUND: Therapeutic monoclonal antibodies (tmabs) have been hypothesized to interfere with immunoassay measurements, although studies investigating this potential new class of interference are lacking. This study evaluated the effects of tmabs used in cancers ipilimumab (Bristol Myers Squibb), nivolumab (Bristol Myers Squibb), pembrolizumab (Merck) and autoimmune disorders adalimumab (AbbVie), infliximab (Janssen) and vedolizumab (Takeda) in common immunoassays used in the clinical laboratory. METHODS: Residual sera from 10 randomly chosen patients were split into two tubes and spiked with same volume (approximately 5 % final volume) of either saline (control) or 6 tmabs (final concentration of 100 µg/mL each). Concentrations from sixteen analytes in 19 different assays were assessed: TSH (Roche and Beckman), free thyroxine (Roche and Siemens), cortisol (Beckman), Cancer Antigens (CA): CA19-9 (Beckman), CA15-3 (Roche), CA125 (Roche), and CA27.29 (Siemens), carcinoembryonic antigen (Beckman), alpha-fetoprotein (Beckman), thyroglobulin (Beckman) and thyroglobulin antibodies (Beckman), thyroid peroxidase antibody (Beckman), beta-human chorionic gonadotropin (Roche and Beckman), total prostate-specific antigen (Roche), parathyroid hormone (Roche) and antinuclear antibodies IgG (Werfen). The tmab spiked residual sera were compared with matched saline spiked sera and percent error was assessed against allowable total error defined from biological variation or CLIA limits. RESULTS: None of the tested immunoassays were affected by the presence of the tmabs, in samples within or outside assay reference intervals. The median % error among all immunoassays ranged between -2.0% (for TSH) to 2.7% (for TPO Ab assay). CONCLUSION: These findings demonstrate no detectable tmab interference for the assessed immunoassays using spiked preparations of the tmabs in residual human sera. The findings are limited to the tmabs and immunoassays studied here.


Assuntos
Anticorpos Monoclonais , Doenças Autoimunes , Masculino , Humanos , Tireoglobulina , Imunoensaio , Tireotropina
14.
J Appl Lab Med ; 7(5): 1047-1061, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35899495

RESUMO

BACKGROUND: Measurement of cholesterol within lipoprotein subfractions may aid in cardiovascular disease prediction. Simple, homogenous enzymatic assays for the direct measurement of lipoprotein subfractions have been developed to measure small dense low-density lipoprotein cholesterol (sdLDL-C), high-density lipoprotein-3 cholesterol (HDL3-C), and triglyceride-rich lipoprotein (TRL-C) cholesterol. The objective of this study was to determine biological variability for sdLDL-C, HDL3-C, and TRL-C in a healthy reference population to facilitate interpretation of these analytes. METHODS: Serum samples were collected from 24 healthy subjects (n = 14 female/10 male) daily for 3 days while non-fasting, and daily for 5 days, weekly for 4 weeks, and monthly for 6 months after overnight fasting. sdLDL-C, HDL3-C, and TRL-C cholesterol were measured by homogenous enzymatic assays. Sources of variability (between-subject, within-subject, and analytical) were calculated using random-effects regression models. Reference change value (RCV) and index of individuality (II) for each time period were determined from the variance components. RESULTS: Analytic variability (daily, weekly, and monthly CVA) was <3% for each analyte. Monthly within-subject variability (CVI) was 17.1% for sdLDL-C, 7.4% for HDL3-C, and 25.7% for TRL-C. Most of the monthly variation was attributed to between-subject variation for all 3 analytes. Overall RCVs for monthly measurements were 18.1 mg/dL for sdLDL-C, 6.1 mg/dL for HDL3-C, and 16.0 mg/dL for TRL-C. IIs were <0.6 for sdLDL-C and HDL3-C, and 0.81 for TRL-C. CONCLUSIONS: sdLDL-C, HDL3-C, and TRL-C showed moderate within-subject variability, but high between-subject variability, in a healthy reference population. Given the high individuality of each analyte, population-based reference intervals may be inadequate to detect clinically significant changes.


Assuntos
Colesterol , Lipoproteínas , HDL-Colesterol , LDL-Colesterol , Feminino , Humanos , Masculino , Triglicerídeos
15.
J Appl Lab Med ; 7(4): 863-870, 2022 06 30.
Artigo em Inglês | MEDLINE | ID: mdl-35092283

RESUMO

BACKGROUND: Ceramides are bioactive lipid species that mediate numerous cell-signaling events. Elevated plasma ceramides concentration constitutes a risk factor for several pathologies. Multiple studies have affirmed the plasma concentrations of 4 specific ceramides (Cer16:0, Cer18:0, Cer24:0, and Cer24:1) can predict cardiovascular disease risk. Furthermore, these ceramides can be altered by many lipid-lowering therapies. Understanding the biological variability within an individual, and within a population, will further inform the clinical use of plasma ceramides as a biomarker. In this study, we aimed to define the intra- and interbiological variability of ceramides in a healthy reference population in a weekly and monthly manner. METHODS: Fasting plasma from 24 healthy adults was collected daily (5 days), weekly (4 weeks), and monthly (7 months). Ceramide concentrations were measured with liquid chromatography-mass spectrometry (LC-MS). For analysis, we used random-effects regression models to estimate variance components. RESULTS: The analytical variability was smaller compared to the biological variability overall. The greatest variation reported was between-subject variation for all ceramide species. The critical difference-reference change value (RCV) for within-subject variations monthly were 0.07 mcmol/L (Cer16:0), 0.04 mcmol/L (Cer18:0), 1.09 mcmol/L (Cer24:0), and 0.27 mcmol/L (Cer24:1). The index of individuality (IOI) of ceramides were 0.82 (Cer16:0), 0.96 (Cer18:0), 1.06 (Cer24:0), and 0.89 (Cer24:1). The most consistent ceramide species was Cer18:0 with the lowest within- and between-subject critical differences in weekly and monthly measurements. CONCLUSIONS: Overall, this study demonstrates that the variability of ceramide concentrations at different time points is minimal within individuals, allowing a single draw to be sufficient at least in a yearly time frame.


Assuntos
Ceramidas , Adulto , Biomarcadores , Cromatografia Líquida/métodos , Voluntários Saudáveis , Humanos , Espectrometria de Massas
16.
Microbiol Spectr ; 10(4): e0115422, 2022 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-35862939

RESUMO

In August 2020, the Food and Drug Administration (FDA) Emergency Use Authorization (EUA) for COVID-19 convalescent plasma (CCP) specified 12 authorized serologic assays and associated assay-specific cutoff values for the selection of high-titer CCP for use in hospitalized patients. The criteria used for establishing these cutoff values remains unclear. Here, we compare the overall agreement and concordance of five serologic assays included in the August 2020 FDA EUA at both the manufacturer-recommended qualitative cutoff thresholds and at the FDA-indicated thresholds for high-titer CCP, using serum samples collected as part of the CCP Expanded Access Program (EAP). The qualitative positive percent agreement (PPA) across assays ranged from 92.3% to 98.8%. However, the high-titer categorization across assays varied significantly, with the PPA ranging from 26.5% to 82.7%. The Roche anti-NC ECLIA provided the lowest agreement compared to all other assays. Efforts to optimize high-titer cutoffs could reduce, although not eliminate, the discordance across assays. The consequences of using nonstandardized assays are apparent in our study, and the high-titer cutoffs chosen for each assay are not directly comparable to each other. The generalized findings in our study will be relevant to any future use of convalescent plasma for either COVID-19 or future pandemics of newly emerged pathogens. IMPORTANCE COVID-19 convalescent plasma (CCP) was one of the first therapeutic options available for the treatment of SARS-CoV-2 infections and continues to be used selectively for immunosuppressed patients. Given the emergence of novel SARS-CoV-2 variants which are resistant to treatment with available monoclonal antibody (MAb) therapy, CCP remains an important therapeutic consideration. The FDA has released several emergency use authorizations (EUA) that have specified which serological assays can be used for qualification of CCP, as well as assay-specific cutoffs that must be used to identify high-titer CCP. In this study, a cohort of donor CCP was assessed across multiple serological assays which received FDA EUA for qualification of CCP. This study indicates a high degree of discordance across the assays used to qualify CCP for clinical use, which may have precluded the optimal use of CCP, including during clinical trials. This study highlights the need for assay standardization early in the development of serological assays for emerging pathogens.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais/uso terapêutico , COVID-19/diagnóstico , COVID-19/terapia , Teste para COVID-19 , Humanos , Imunização Passiva , Estados Unidos , United States Food and Drug Administration , Soroterapia para COVID-19
17.
Am J Clin Pathol ; 156(5): 722-727, 2021 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-34075393

RESUMO

OBJECTIVES: To determine the influence of pH on recovery of analytes in body fluids (BFs), investigate the mechanism of pH interference, measure the frequency of abnormal-pH BFs received, and compare pH measured by meter and paper. METHODS: We performed pH titration in residual BFs. A low-pH BF was spiked and neutralized to investigate pH interference. We measured analytes on a Roche cobas c501 analyzer (Roche Diagnostics) and calculated the percent recovery. Measurement of pH using a meter and paper was conducted on 122 BF samples received in the laboratory. RESULTS: Enzyme activity in BFs was unaffected when pH = 7.4-8.5 lactate dehydrogenase, pH = 7.3-10.2 amylase, pH = 6.0-9.9 lipase, and pH = 1.3-11.7 all other analytes. BFs had mean (range) pH of 8.0 (5.1-8.9), with a mean (range) difference (paper ‒ meter) of ‒0.4 (‒0.6 to 1.1). CONCLUSIONS: Irreversible loss of enzyme activity occurs in BFs at low pH. Few clinical BFs have pH < 7.0, but laboratories should incorporate pH measurement in BF workflows.


Assuntos
Líquidos Corporais/química , Testes Diagnósticos de Rotina , Ensaios Enzimáticos/métodos , Concentração de Íons de Hidrogênio , Amilases/análise , Testes Diagnósticos de Rotina/instrumentação , Testes Diagnósticos de Rotina/métodos , Humanos , L-Lactato Desidrogenase/análise , Lipase/análise
18.
J Appl Lab Med ; 6(4): 992-997, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-33907809

RESUMO

BACKGROUND: It is important for clinical laboratories to have protocols for investigating suspected biotin interference in patient samples. VeraPrep Biotin™ is a commercial product used to rapidly deplete biotin from serum/plasma samples. The objectives of this study were to verify that VeraPrep Biotin™: (a) does not impact immunoassay analyte recovery in control samples and (b) can effectively deplete biotin from samples (both biotin-spiked and samples from donors who ingested biotin supplements). METHODS: De-identified residual waste serum/plasma samples were combined to create 9 pools for each immunoassay. Plasma/serum samples (n = 23) were obtained from 6 healthy donors at varying times following ingestion of biotin (20 mg, 100 mg, or 200 mg). Nine Elecsys immunoassays were evaluated using the e 602 (Roche Diagnostics Inc.). Control, biotin-spiked (n = 10, ∼400 ng/mL), and donor samples were assayed pre- and post-VeraPrep treatment. Percentage analyte recovery [(posttreatment/pretreatment) × 100] was calculated for control samples. A laboratory-developed LC-MS/MS method was used to quantify biotin. RESULTS: In control samples (n = 81), 90-110% analyte recovery was observed post-VeraPrep treatment in over 95% of samples (77/81). The pre- and post-VeraPrep treatment biotin concentration [mean ± standard deviation (SD)] for specimens spiked with up to 500 ng/mL biotin was 357 ± 47 ng/mL and 1.0 ± 0.6 ng/mL, respectively. The mean (range) biotin concentration for the donor samples pre- and post-treatment was 166 (15-1029) ng/mL and 0.2 (<0.1-3) ng/mL, respectively (P = 0.004). CONCLUSIONS: These data demonstrate that treatment with VeraPrep Biotin™ does not affect analyte recovery in biotin-negative samples and effectively depletes both spiked and endogenous biotin in serum/plasma.


Assuntos
Biotina , Espectrometria de Massas em Tandem , Cromatografia Líquida , Humanos , Imunoensaio , Indicadores e Reagentes , Estreptavidina
19.
Am J Clin Pathol ; 156(6): 1121-1129, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34223873

RESUMO

OBJECTIVES: To evaluate the analytical and clinical performance characteristics of the fifth-generation troponin T reagent. METHODS: Troponin T was measured in 2,332 paired serum and plasma samples from emergency department and hospital patients using the fourth- and fifth-generation reagents. Testing was repeated after recentrifugation to determine the frequency of analytical outliers and percentage of patients with elevated values for each assay. We conducted separate experiments to determine the effects of biotin and hemolysis interference, as well as measure interinstrument variability, for fifth-generation troponin T. RESULTS: Analytic outliers occurred more frequently using the fifth-generation reagent (3.4%) compared with the fourth-generation reagent (1.0%). The frequency of elevated troponin T above the 99th percentile upper reference limit was 26% for the fourth-generation reagent and 52% for the fifth-generation reagent. Clinically significant assay interference by biotin was observed at 20 ng/mL, but hemolysis interference was not observed until an H index of 150. Instrument-to-instrument variability between e411 and e601/602 instrument platforms is predicted to confound clinical interpretation of troponin changes. CONCLUSIONS: Analytical outliers and instrument-to-instrument variability are the two analytical variables most likely to confound interpretation of changes in fifth-generation troponin T results over time.


Assuntos
Biotina , Troponina T , Testes Diagnósticos de Rotina , Serviço Hospitalar de Emergência , Hemólise , Humanos , Valores de Referência
20.
J Clin Virol Plus ; 1(3): 100030, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35262016

RESUMO

Serologic testing for SARS-CoV-2 can be used for evaluation of past infection in individual patients and for community seroprevalence studies. We evaluated the analytical and clinical performance of the Genalyte Maverick SARS-CoV-2 Multi-Antigen Serology Panel compared to the Roche Elecsys Anti-SARS-CoV-2 nucleocapsid (NC) qualitative immunoassay, using well characterized clinical serum samples. A total of 143 pre-pandemic sera and 48 sera collected from patients with a negative molecular SARS-CoV-2 result were used for specificity studies. For sensitivity analyses, 179 sera were used, obtained 3-7 days, 8-14 days, or ≥ 15 days after symptom onset from patients with confirmed SARS-CoV-2 infection. Specificity was determined to be 95.3% (182/191) for the Genalyte Maverick. Overall sensitivity of the Genalyte Maverick was similar to that observed for the Roche Elecsys NC test, 79.3% (142/179) vs. 76.5% (137/179), respectively. Genalyte Maverick trended, without statistical significance, towards higher sensitivity as compared to the Roche Elecsys NC test in the 3-7 days (11/25 vs. 9/25, respectively) and 8-14 days (21/28 vs. 19/28, respectively) post-symptom onset sample sets, but was identical in the ≥ 15 days post-symptom onset group (106/116 vs. 106/116, respectively). Therefore, the Genalyte Maverick serologic test had similar overall sensitivity to the Roche Elecsys NC assay, but may have slightly improved sensitivity for early seroconversion. The lower Genalyte Maverick specificity as compared to the Roche Elecsys NC assay as reported by other studies (>99%), may necessitate confirmatory testing of positive Genalyte Maverick results if implemented for clinical use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA