Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Minim Invasive Gynecol ; 25(4): 697-705, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29158158

RESUMO

STUDY OBJECTIVE: To prospectively determine the accuracy of magnetic resonance enterography (MRE) compared with conventional magnetic resonance imaging (MRI) for multifocal (i.e., multiple lesions affecting the same digestive segment) and multicentric (i.e., multiple lesions affecting several digestive segments) bowel endometriosis. DESIGN: A prospective study (Canadian Task Force classification II-2). SETTING: Tenon University Hospital, Paris, France. PATIENTS: Patients with MRI-suspected colorectal endometriosis scheduled for colorectal resection from April 2014 to February 2016 were included. INTERVENTIONS: Patients underwent both 1.5-Tesla MRI and MRE as well as laparoscopically assisted and open colorectal resections. MEASUREMENTS AND MAIN RESULTS: The diagnostic performance of MRI and MRE was evaluated for sensitivity, specificity, positive and negative predictive values, accuracy, and positive and negative likelihood ratios (LRs). The interobserver variability of the experienced and junior radiologists was quantified using weighted statistics. Forty-seven patients were included. Twenty-two (46.8%) patients had unifocal lesions, 14 (30%) had multifocal lesions, and 11 (23.4%) had multicentric lesions. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multifocal lesions were 0.29 (6/21), 1.00 (23/24), 15.36, and 0.71 for MRI and 0.57 (12/21), 0.89 (23/25), 4.95, and 0.58 for MRE. The sensitivity, specificity, positive LR, and negative LR for the diagnosis of multicentric lesions were 0.18 (1/11), 1.00 (1/1), 15, and 0.80 for MRI and 0.46 (5/11), 0.92 (33/36), 5.45, and 0.60 for MRE. Lower accuracies for MRI compared with MRE to diagnose multicentric (p = .01) and multifocal lesions (p = .004) were noted. The interobserver agreement for MRE was good for both multifocality (κ = 0.80) and multicentricity (κ = 0.61). CONCLUSION: MRE has better accuracy for diagnosing multifocal and multicentric bowel endometriosis than conventional MRI.


Assuntos
Doenças do Colo/diagnóstico por imagem , Endometriose/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doenças Retais/diagnóstico por imagem , Adulto , Doenças do Colo/cirurgia , Meios de Contraste , Endometriose/cirurgia , Feminino , Gadolínio , Humanos , Funções Verossimilhança , Pessoa de Meia-Idade , Estudos Prospectivos , Doenças Retais/cirurgia , Sensibilidade e Especificidade
2.
Front Surg ; 7: 614989, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33392249

RESUMO

Objective: The aim of the study was to evaluate three-dimensional (3D) T2 MRI before and after vaginal opacification (VO) by gel (3DT2VO) and the additional value of 3DT1 with fat-suppression (3DT1FS) MRI in the diagnosis of vaginal endometriosis. Methods: In this study conducted from 2010 to 2013, 51 patients scheduled for surgical treatment of endometriosis underwent MRI 1 day before surgery. Three readers (novice, intermediate, expert) were asked to retrospectively diagnose vaginal endometriosis independently and blindly using four different readings (i.e., 3DT2, 3DT2VO, 3DT2 with 3DT1FS, 3DT2VO with 3DT1FS). Vaginal endometriosis diagnosis was positive on observation of a thickening of vaginal walls on 3DT2 with or without high-signal-intensity spots on 3DT2 and/or 3DT1FS. The reference standard was surgery and histology. Descriptive analysis, Chi-square test, and ROC curves were used for statistical analysis. Results: For all readers, the combination of 3DT2 and 3DT1FS significantly improved the diagnosis of vaginal endometriosis compared with 3DT2 (p = 0.002, p = 0.02, and p = 0.003). 3DT2VO significantly improved diagnosis for the intermediate reader (p = 0.01). High-signal-intensity spots on 3DT1FS had a sensitivity of 50-63.6%, specificity of 86.2-96.6%, and high positive likelihood ratios (14.5-Inf). Conclusion: 3DT2 in association with 3DT1FS appears to be the best 3D MRI protocol for the diagnosis of vaginal endometriosis, whatever the level of experience of readers. The additional value of 3DT2VO is variable among the readers.

3.
Presse Med ; 46(12 Pt 1): 1166-1172, 2017 Dec.
Artigo em Francês | MEDLINE | ID: mdl-29153376

RESUMO

The diagnosis of pelvic endometriosis is based on the combination of clinical examination, endovaginal ultrasonography and pelvic MRI. Ultrasonography displays a moderate sensitivity and a high specificity. Pelvien MRI displays a better sensitivity and lower specificity.


Assuntos
Endometriose/diagnóstico por imagem , Endometriose/cirurgia , Feminino , Humanos , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA