1.
Sensors (Basel) ; 23(3)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36772647

RESUMO

Wearable technology is playing an increasing role in the development of user-centric applications. In the field of sports, this technology is being used to implement solutions that improve athletes' performance, reduce the risk of injury, or control fatigue, for example. Emotions are involved in most of these solutions, but unfortunately, they are not monitored in real-time or used as a decision element that helps to increase the quality of training sessions, nor are they used to guarantee the health of athletes. In this paper, we present a wearable and a set of machine learning models that are able to deduce runners' emotions during their training. The solution is based on the analysis of runners' electrodermal activity, a physiological parameter widely used in the field of emotion recognition. As part of the DJ-Running project, we have used these emotions to increase runners' motivation through music. It has required integrating the wearable and the models into the DJ-Running mobile application, which interacts with the technological infrastructure of the project to select and play the most suitable songs at each instant of the training.


Assuntos
Desempenho Atlético , Aplicativos Móveis , Dispositivos Eletrônicos Vestíveis , Humanos , Motivação , Aprendizado de Máquina
2.
Sensors (Basel) ; 22(15)2022 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-35957330

RESUMO

This paper presents a new physiological signal acquisition multi-sensory platform for emotion detection: Multi-sensor Wearable Headband (MsWH). The system is capable of recording and analyzing five different physiological signals: skin temperature, blood oxygen saturation, heart rate (and its variation), movement/position of the user (more specifically of his/her head) and electrodermal activity/bioimpedance. The measurement system is complemented by a porthole camera positioned in such a way that the viewing area remains constant. Thus, the user's face will remain centered regardless of its position and movement, increasing the accuracy of facial expression recognition algorithms. This work specifies the technical characteristics of the developed device, paying special attention to both the hardware used (sensors, conditioning, microprocessors, connections) and the software, which is optimized for accurate and massive data acquisition. Although the information can be partially processed inside the device itself, the system is capable of sending information via Wi-Fi, with a very high data transfer rate, in case external processing is required. The most important features of the developed platform have been compared with those of a proven wearable device, namely the Empatica E4 wristband, in those measurements in which this is possible.


Assuntos
Reconhecimento Facial , Dispositivos Eletrônicos Vestíveis , Algoritmos , Emoções/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino
3.
Sensors (Basel) ; 21(9)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946219

RESUMO

The application of MEMS capacitive accelerometers isimited by its thermal dependence, and each accelerometer must be individually calibrated to improve its performance. In this work, aight calibration method based on theoretical studies is proposed to obtain two characteristic parameters of the sensor's operation: the temperature drift of bias and the temperature drift of scale factor. This method requiresess data to obtain the characteristic parameters, allowing a faster calibration. Furthermore, using an equation with fewer parameters reduces the computational cost of compensation. After studying six accelerometers, modelIS3DSH, their characteristic parameters are obtained in a temperature range between 15 °C and 55 °C. It is observed that the Temperature Drift of Bias (TDB) is the parameter with the greatest influence on thermal drift, reaching 1.3 mg/°C. The Temperature Drift of Scale Factor (TDSF) is always negative and ranges between 0 and -400 ppm/°C. With these parameters, the thermal drifts are compensated in tests with 20 °C of thermal variation. An average improvement of 47% was observed. In the axes where the thermal drift was greater than 1 mg/°C, the improvement was greater than 80%. Other sensor behaviors have also been analyzed, such as temporal drift (up to 1 mg/h for three hours) and self-heating (2-3 °C in the first hours with the corresponding drift). Thermal compensation has been found to reduce the effect of theatter in the first hours after power-up of the sensor by 43%.

4.
Micromachines (Basel) ; 13(4)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35457889

RESUMO

Capacitive MEMS accelerometers have a high thermal sensitivity that drifts the output when subjected to changes in temperature. To improve their performance in applications with thermal variations, it is necessary to compensate for these effects. These drifts can be compensated using a lightweight algorithm by knowing the characteristic thermal parameters of the accelerometer (Temperature Drift of Bias and Temperature Drift of Scale Factor). These parameters vary in each accelerometer and axis, making an individual calibration necessary. In this work, a simple and fast calibration method that allows the characteristic parameters of the three axes to be obtained simultaneously through a single test is proposed. This method is based on the study of two specific orientations, each at two temperatures. By means of the suitable selection of the orientations and the temperature points, the data obtained can be extrapolated to the entire working range of the accelerometer. Only a mechanical anchor and a heat source are required to perform the calibration. This technique can be scaled to calibrate multiple accelerometers simultaneously. A lightweight algorithm is used to analyze the test data and obtain the compensation parameters. This algorithm stores only the most relevant data, reducing memory and computing power requirements. This allows it to be run in real time on a low-cost microcontroller during testing to obtain compensation parameters immediately. This method is aimed at mass factory calibration, where individual calibration with traditional methods may not be an adequate option. The proposed method has been compared with a traditional calibration using a six tests in orthogonal directions and a thermal chamber with a relative error difference of 0.3%.