Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38820201

RESUMO

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

2.
Catheter Cardiovasc Interv ; 103(1): 194-201, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38037296

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) using balloon-expandable (BE) transcatheter heart valves (THV) in aortic annuli above 29 mm includes particular procedural steps, mainly involving overfilling of the deployment balloon. Data on overfilling strategies in clinical daily practice is scarce. We herein aimed for a retrospective description of utilized overfilling strategies in those patients. METHODS: Between January 2016 and December 2022, 45 patients (100% male, 76.9 ± 6.1 years) received TAVI in aortic annuli above 29 mm using a BE THV. Overfilling volumina of the deployment balloon were left to operators' discretion. Clinical and multislice computed tomography data were retrospectively collected. Clinical endpoints were adjudicated in accordance with the updated standardized VARC-3 definitions. RESULTS: Profound overfilling (+4/5 mL) was used in patients with a mild calcium burden (˂750 mm³) even in aortic annuli of 29.0-30.0 mm. Nominal/slight overfilling (+1 mL) was used in aortic annuli up to 32.5 mm but an intermediate to severe calcific burden (>750-3200 mm³). Accordingly, a low calcification group (˂750 mm³, n = 17) compared to a significant calcification group (≥750 mm³, n = 28), presented with higher overfilling volumina (2.1 ± 1.4 vs. 0.8 ± 1.0; p ˂ 0.001), although aortic annulus diameter was not different (29.8 ± 0.8 vs. 29.9 ± 0.9 mm; p = 0.7). All-cause 30-day mortality was 0%. Device success was 97.8%. Transvalvular mean pressure gradient at discharge was 9.5 ± 3.6 mmHg. No case of PVL >mild was documented. CONCLUSION: Extent of overfilling of the deployment balloon largely depends on calcification burden in addition to aortic annulus diameter with significant and profound overfilling particularly in patients with a calcification burden of the aortic valve complex ˂750 mm³.


Assuntos
Estenose da Valva Aórtica , Calcinose , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/terapia , Desenho de Prótese
3.
Artigo em Inglês | MEDLINE | ID: mdl-36216331

RESUMO

BACKGROUND: Systemic inflammation due to cardiogenic shock is associated with vasoplegia leading to organ hypoperfusion, right heart failure, and poor clinical outcome. Extracorporeal cytokine hemoadsorption emerged to attenuate excessive levels of inflammatory cytokines, potentially improving patient outcomes. Nevertheless, its prognostic impact during high-risk left ventricular assist device (LVAD) implantation remains unknown. METHODS: In total, 40 consecutive patients with advanced heart failure underwent continuous-flow LVAD implantation at our institution between 2018 and 2020. Out of 25 high-risk patients in cardiogenic shock (Interagency Registry for Mechanically Assisted Circulatory Support profile 1 and 2), 9 patients (CytoSorb group) underwent LVAD implantation with and 16 patients (control group) without simultaneous cytokine hemoadsorption during cardiopulmonary bypass. Besides preoperative patient characteristics, postoperative lactate clearance, vasopressor administration and mean arterial pressure, perioperative complication, and 30-day mortality rates were retrospectively analyzed. RESULTS: Apart from an increased rate of reoperations within the CytoSorb group, baseline characteristics including the severity of ventricular dysfunction and consecutive signs of end-organ failure were similar in both groups. Preoperative short-term mechanical circulatory support bridging was comparable (66.7 vs. 75%; p = 0.66) prior to LVAD implantation. Procedural characteristics including intraoperative volume management and postoperative vasopressor administration were similar in both groups. There was no difference regarding postoperative lactate clearance, although postoperative mean arterial pressure was significantly higher in the control group (71.3 vs. 57.4 mm Hg; p < 0.01). Furthermore, the 30-day mortality rate was significantly higher in the CytoSorb group (33.3 vs. 0.0%; p = 0.01). CONCLUSION: Extracorporeal cytokine hemoadsorption during high-risk LVAD implantation was not associated with a decrease of postoperative vasopressor support, improved hemodynamics, or an accelerated lactate clearance.

4.
Catheter Cardiovasc Interv ; 98(2): E291-E298, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33315296

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) via transaxillary (TAx) approach with ACURATE neo valve is an off-label procedure. Our aim was to gather information on ACURATE neo cases implanted via TAx approach and report major outcomes. METHODS AND RESULTS: The TRANSAX Study (NCT04274751) retrospectively gathered patients from nine centres in Europe and North America treated with ACURATE neo valve through TAx approach up to May/2019. Follow up was pre-specified at 1-year and was obtained for all patients. A total of 75 patients (79 ± 10 years; 32% women) were included. Left axillary (72%) and conscious sedation (95.2%) were the most common setting. Risk scores were higher when right axillary artery and surgical cut-down were selected. Severe complications including valve embolization, coronary obstruction, annulus rupture, and procedural mortality did not occur. Cardiac tamponade occurred in two cases (2.7%) with one requiring conversion to open surgery (1.3%). Bail-out stenting and surgical vascular repair were required in 7 (9.3%) and 3 (4%) cases, respectively. The need for new permanent pacemaker was 8%. Procedural success (96%), in-hospital (2.7%), and 1-year mortality (8%) were comparable in all settings. Only one case (1.3%) complicated with cerebrovascular event and one (1.3%) presented moderate aortic regurgitation before discharge. CONCLUSIONS: TAx TAVR procedures with the ACURATE neo valve were presented high success rate and low in-hospital and 1-year mortality.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 98(4): 756-764, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33991385

RESUMO

OBJECTIVES: To evaluate outcome and its predictors of bioprosthetic valve fracture (BVF) in patients undergoing valve-in-valve transcatheter aortic valve replacement (VIV-TAVR). BACKGROUND: BVF is feasible and reduces transvalvular gradients in VIV-TAVR-procedures, but follow-up-data and information on factors influencing the outcome are missing. METHODS: The 81 cases of BVF-VIV-TAVR were collected from 14 international centers. RESULTS: Predominantly transcatheter heart valve (THV) was implanted first, followed by BVF. VARC-2 defined device success was 93%, most failures were attributed to residual high gradients. Mean gradients decreased from 37 ± 13 mmHg to 10.8 ± 5.9 mmHg (p < 0.001). BVF reduced the gradient by 16 mmHg. During follow-up (FU, 281 ± 164 days) mean gradient remained stable (10.8 ± 5.9 mmHg at discharge, 12.4 ± 6.3 mmHg at FU, p = ns). In-hospital major adverse events occurred in 3.7%. Event-free survival at 276 ± 237.6 days was 95.4%. The linear mixed model identified balloon-expandable valves (BEV), Mitroflow surgical valve, stenotic surgical bioprostheses and balloon only 1 mm larger than the true internal diameter of the surgical valve as predictors for higher gradients. CONCLUSIONS: BVF is safe and can significantly reduce gradients, which remain stable at FU. BEV, Mitroflow surgical valve, stenotic bioprostheses and balloon larger than the true internal diameter of the surgical valve of only 1 mm are predictors for higher final gradients.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Hemodinâmica , Humanos , Desenho de Prótese , Falha de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Am Heart J ; 225: 138-148, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32502877

RESUMO

BACKGROUND: Compared to high gradient aortic stenosis (AS), patients with low-flow, low-gradient AS have higher mortality after transcatheter aortic valve replacement (TAVR), but distinct outcome predictors in this patient subset are yet to be determined. The present study investigated the prognostic impact of aortic valve calcification (AVC) in patients with low-flow, low-gradient AS undergoing TAVR. METHODS: This retrospective single-center analysis includes all patients undergoing TAVR for severe low-flow, low-gradient AS (n = 526), ie, low EF low gradient AS (LEF-LG AS; n = 290) and paradoxical low-flow, low-gradient AS (PLF-LG AS; n = 236), in whom AVC was quantified from contrast-enhanced multislice computed tomography images. AVCdensity was defined as calcium volume per annulus area. Patients were trichotomized according to sex-specific AVCdensity tertiles in both subgroups. All-cause mortality was assessed by Kaplan-Meier analyses and independent outcome predictors were determined by multivariable analyses. RESULTS: In both subgroups, patients with high AVCdensity had higher mean transvalvular gradients at baseline and higher rates of PVL after TAVR. High AVCdensity was associated with lowest 1- and 3-year mortality after TAVR in the LEF-LG AS but not in the PLF-LG AS group. According to multivariable analysis AVCdensity was independently associated with better survival in LEF-LG AS patients (HR 0.73 [0.60-0.88], P = .0011), but not in those with PLF-LG AS (HR 0.91 [0.73-1.14], P = .42). CONCLUSIONS: Quantification of AVC may not only be of diagnostic but also of prognostic value, as it facilitates the selection of LEF-LG AS patients with higher probability of beneficial outcome after TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/patologia , Calcinose/classificação , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/fisiopatologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Volume Sistólico
7.
Gut ; 68(1): 150-157, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29217749

RESUMO

OBJECTIVE: Hepatitis delta virus (HDV) was shown to persist for weeks in the absence of HBV and for months after liver transplantation, demonstrating the ability of HDV to persevere in quiescent hepatocytes. The aim of the study was to evaluate the impact of cell proliferation on HDV persistence in vitro and in vivo. DESIGN: Genetically labelled human sodium taurocholate cotransporting polypeptide (hNTCP)-transduced human hepatoma(HepG2) cells were infected with HBV/HDV and passaged every 7 days for 100 days in the presence of the entry inhibitor Myrcludex-B. In vivo, cell proliferation was triggered by transplanting primary human hepatocytes (PHHs) isolated from HBV/HDV-infected humanised mice into naïve recipients. Virological parameters were measured by quantitative real time polymerase chain reaction (qRT-PCR). Hepatitis delta antigen (HDAg), hepatitis B core antigen (HBcAg) and cell proliferation were determined by immunofluorescence. RESULTS: Despite 15 in vitro cell passages and block of viral spreading by Myrcludex-B, clonal cell expansion permitted amplification of HDV infection. In vivo, expansion of PHHs isolated from HBV/HDV-infected humanised mice was confirmed 3 days, 2, 4 and 8 weeks after transplantation. While HBV markers rapidly dropped in proliferating PHHs, HDAg-positive hepatocytes were observed among dividing cells at all time points. Notably, HDAg-positive cells appeared in clusters, indicating that HDV was transmitted to daughter cells during liver regeneration even in the absence of de novo infection. CONCLUSION: This study demonstrates that HDV persists during liver regeneration by transmitting HDV RNA to dividing cells even in the absence of HBV coinfection. The strong persistence capacities of HDV may also explain why HDV clearance is difficult to achieve in HBV/HDV chronically infected patients.


Assuntos
Coinfecção/virologia , Hepatite B/virologia , Hepatite D/virologia , Vírus Delta da Hepatite/metabolismo , Regeneração Hepática , Animais , Divisão Celular , Linhagem Celular , Proliferação de Células , Imunofluorescência , Humanos , Camundongos , RNA Viral/metabolismo , Reação em Cadeia da Polimerase em Tempo Real
8.
Hepatology ; 60(5): 1483-93, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24711282

RESUMO

UNLABELLED: Chronic hepatitis B virus (HBV) infection has been associated with alterations in lipid metabolism. Moreover, the Na+-taurocholate cotransporting polypeptide (NTCP), responsible for bile acid (BA) uptake into hepatocytes, was identified as the functional cellular receptor mediating HBV entry. The aim of the study was to determine whether HBV alters the liver metabolic profile by employing HBV-infected and uninfected human liver chimeric mice. Humanized urokinase plasminogen activator/severe combined immunodeficiency mice were used to establish chronic HBV infection. Gene expression profiles were determined by real-time polymerase chain reaction using primers specifically recognizing transcripts of either human or murine origin. Liver biopsy samples obtained from HBV-chronic individuals were used to validate changes determined in mice. Besides modest changes in lipid metabolism, HBV-infected mice displayed a significant enhancement of human cholesterol 7α-hydroxylase (human [h]CYP7A1; median 12-fold induction; P<0.0001), the rate-limiting enzyme promoting the conversion of cholesterol to BAs, and of genes involved in transcriptional regulation, biosynthesis, and uptake of cholesterol (human sterol-regulatory element-binding protein 2, human 3-hydroxy-3-methylglutaryl-coenzyme A reductase, and human low-density lipoprotein receptor), compared to uninfected controls. Significant hCYP7A1 induction and reduction of human small heterodimer partner, the corepressor of hCYP7A1 transcription, was also confirmed in liver biopsies from HBV-infected patients. Notably, administration of Myrcludex-B, an entry inhibitor derived from the pre-S1 domain of the HBV envelope, provoked a comparable murine CYP7A1 induction in uninfected mice, thus designating the pre-S1 domain as the viral component triggering such metabolic alterations. CONCLUSION: Binding of HBV to NTCP limits its function, thus promoting compensatory BA synthesis and cholesterol provision. The intimate link determined between HBV and liver metabolism underlines the importance to exploit further metabolic pathways, as well as possible NTCP-related viral-drug interactions.


Assuntos
Ácidos e Sais Biliares/metabolismo , Colesterol/metabolismo , Vírus da Hepatite B/fisiologia , Hepatite B/metabolismo , Hepatócitos/metabolismo , Animais , Colesterol 7-alfa-Hidroxilase/metabolismo , Expressão Gênica , Hepatite B/virologia , Interações Hospedeiro-Patógeno , Humanos , Metabolismo dos Lipídeos , Lipopeptídeos , Camundongos SCID , Camundongos Transgênicos , Receptores Citoplasmáticos e Nucleares/metabolismo
9.
Clin Res Cardiol ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466346

RESUMO

BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.

10.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37138103

RESUMO

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia , Sistema de Registros , Desenho de Prótese
11.
Front Cardiovasc Med ; 10: 1158248, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37332585

RESUMO

Objectives: Implantation of implantable cardioverter defibrillators (ICD) reduces the risk of all-cause mortality in symptomatic heart failure (HF) patients with severe left ventricular (LV) dysfunction. Nevertheless, the prognostic impact of ICD therapy in continuous flow left ventricular assist device (LVAD) recipients remains controversial. Methods: 162 consecutive HF patients, who underwent LVAD implantation at our institution between 2010 and 2019, were categorized according to the presence (n = 94, ICD-group) or absence (n = 68, Control-group) of ICDs. Apart from clinical baseline and follow-up parameters, adverse events (AEs) related to ICD therapy and overall survival rates were retrospectively analyzed. Results: Out of 162 consecutive LVAD recipients 79 patients (48.8%) were preoperatively categorized as Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profile ≤2. The prevalence of severe HF symptoms and preoperative use of short-term circulatory support devices (54.4% vs. 13.8%, p < 0.001) was higher within the Control-group, although baseline severity of LV and RV dysfunction was similar. Apart from an increased prevalence of perioperative right heart failure (RHF) within the Control-group (45.6% vs. 17.0%; p < 0.001), procedural characteristics and perioperative outcome were similar. Overall-survival during a median follow-up of 14 (3.0-36.5) months was similar within both groups (p = 0.46). During the first 2 years after LVAD implantation 53 ICD-related AEs occurred within the ICD-group. Thereof, lead-dysfunction occurred in 19 patients and unplanned ICD-reintervention in 11 patients. Furthermore, in 18 patients appropriate shocks without loss of consciousness occurred, whereas inappropriate shocks occurred in 5 patients. Conclusion: ICD therapy in LVAD recipients was not associated with a survival benefit or reduced morbidity after LVAD implantation. Conservative ICD-programming seems to be justified to avoid ICD-related complications and "awake shocks" after LVAD implantation.

12.
Front Cardiovasc Med ; 10: 1182752, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38094126

RESUMO

Introduction: Despite increasing use of transcatheter approaches, endoscopic mitral valve surgery (MVS) remains an established option for treatment of mitral regurgitation (MR). Nevertheless, as perioperative risk increases with age, outcome of endoscopic MVS in elderly patients is uncertain. Methods: We retrospectively analyzed 756 consecutive patients with MR ≥2, who underwent minimally-invasive MVS at our institution between 2016 and 2022. Patients were stratified by age ≥75 (elderly-group; n = 91) or <75 years (control-group; n = 665). All patients received endoscopic MVS via right anterolateral minithoracotomy with non-rib spreading soft tissue retraction and 3D-camera visualization. Results: Overall surgical risk was increased in the elderly-group (median age of 77 (76-80) years vs. 58 (51-67) years, p < 0.001) with STS-PROM Scores of 1.9% vs. 0.4% (p < 0.001) and increased prevalence of hypertension, diabetes, coronary artery disease and atrial fibrillation (AFib). Elderly patients were also more symptomatic (NYHA class III 45.7% vs. 29.8%; p = 0.002). Axillo-femoral perfusion was more frequently used in the elderly-group (27.5% vs. 4.2%; p < 0.001). Cross-clamp and cardiopulmonary bypass times were similar. Rate of MV repair was 85.7% vs. 93.8% (p = 0.005). Closure of the left atrial appendage was more frequently performed in the elderly-group (45.1% vs. 23.9%; p < 0.001), whereas rate of concomitant tricuspid valve repair was similar (11.0% vs. 8.9%; p = 0.511). Postoperative complications including perioperative hemodialysis (3.3% vs. 2.9%; p = 0.739), low cardiac output (5.3% vs. 3.8%; p = 0.393), perioperative stroke (1.1% vs. 0.15%; p = 0.224) and myocardial infarction (0% vs. 0.15%) were favorably low in both groups. Acute mortality at 30 days was 2.2% vs. 0.4% (p = 0.112). Conclusion: Despite increased prevalence of outcome-relevant comorbidities and surgical risk, perioperative outcome of patients aged ≥75 years undergoing endoscopic MVS is favorable. Therefore, endoscopic MVS is a valuable therapeutic option for selected elderly patients and should be taken in consideration during routine heart-team discussion.

13.
Clin Res Cardiol ; 112(5): 667-676, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36656376

RESUMO

BACKGROUND: Ejection time (ET), acceleration time (AT) and time between left ventricular and aortic systolic pressure peaks (T-LVAo) might be of diagnostic and prognostic use in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). AIM: We aimed to assess the diagnostic value and prognostic impact of invasively measured ET, AT, and T-LVAo in patients undergoing TAVI. METHODS: A total of 1274 patients received invasive measurement of ET, AT and T-LVAo prior to TAVI. Anatomic AS severity was assessed by CT-derived aortic valve calcification density (AVCd). Impact on all-cause mortality was retrospectively analyzed. RESULTS: In multivariable linear regression, T-LVAo showed the strongest correlation with AVCd. No prognostic impact of T-LVAo was found according to uni- and multivariable analyses. In contrast, using an individual C-statistic derived cutoff (CD), patients with ET or AT ≥ CD showed lower mortality rates compared to patients with ET or AT < CD (1-year mortality: ET ≥ vs. < CD: 15.01vs. 33.1%, AT ≥ vs < CD 16.3 vs. 26.5%, p < 0.001). Moreover, multivariable analysis identified ET ≥ CD (HR 0.61 [95% CI 0.43-0.87; p < 0.007]) to be associated with beneficial outcome after TAVI, independent from clinical risk factors and echocardiography-derived parameters. CONCLUSION: Among the studied hemodynamic parameters T-LVAo provides the highest diagnostic value, whereas ET is an outcome predictor beyond clinical risk factors and echocardiographic parameters in AS patients following TAVI. These parameters could be of considerable use in diagnostic evaluation and risk assessment of patients scheduled for TAVI. T-LVAo (yellow): defined as time between left ventricular and aortic systolic pressure peaks. ET (green): Ejection Time defined as time from the start to flow end. AT (orange): Acceleration time defined as time from the start to the peak flow. AOP: aortic pressure, AVC: aortic valve calcification, CI: confidence interval, HGAS: high-gradient aortic stenosis, LGAS: low-gradient aortic stenosis, LVP: left ventricular pressure, SD: standard deviation.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Hemodinâmica , Função Ventricular Esquerda , Volume Sistólico , Índice de Gravidade de Doença
14.
Clin Res Cardiol ; 112(5): 691-701, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36792752

RESUMO

BACKGROUND: Beneficial results of transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) in patients at all risk strata have led to substantial changes in guideline recommendations for valvular heart disease. AIM: To examine influence of these guideline changes on a real-world TAVI cohort, we evaluated how risk profiles and outcomes of TAVI patients developed in our single-center patient cohort over a period of 12 years. METHODS: Baseline, procedural and 30-day outcome parameters of TAVI patients were retrospectively compared between three time periods (period 1: 2008-2012, period 2: 2013-2017, period 3: 2018-2020). RESULTS: Between 03/2008 and 12/2020, a total of 3678 patients underwent TAVI at our center. The median age was 81.1 years (25th, 75th percentile: 76.7, 84.9) with no significant change over time. The EuroSCORE II showed a continuous and significant decline from 5.3% (3.3, 8.6) in period 1 to 2.8% (1.7, 5.0) in period 3 (p < 0.001). Furthermore, rates of permanent pacemaker implantation, acute kidney injury, and paravalvular leakage ≥ moderate continuously declined over time. Accordingly, the 30-day mortality fell from 9.3% in period 1 to 4.3% in period 3 (p < 0.001). CONCLUSION: Despite substantial guideline alterations, median patient age remained largely unchanged in our TAVI cohort over the past 12 years. Therefore, increased age still appears to be the main reason to choose TAVI over SAVR. However, risk profiles declined substantially. Significant improvements in early outcomes suggest favorable influence of less invasive access routes, improved device platforms and growing user experience.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Criança , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos
15.
Front Cardiovasc Med ; 10: 1209184, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727306

RESUMO

Background: Valve-in-valve (ViV) transfemoral transcatheter aortic valve implantation (TAVI) for failing aortic surgical bioprostheses or transcatheter heart valves (THV) has demonstrated a reasonable clinical and hemodynamic efficacy. Traditionally, self-expanding (SE) supra-annular THV are considered to result in superior hemodynamics compared with balloon-expandable intra-annular THV after ViV. However, so far no data are found on latest-generation intra-annular SE THV for aortic ViV procedures which might be superior with regard to coronary access or subsequent valve reintervention. Aim: We herein aim to evaluate a latest-generation SE intra-annular THV for aortic ViV procedures. Materials and methods: Between May 2022 and November 2022, five consecutive patients (4/5 female with mean age of 76.2 years and mean Society of Thoracic Surgeons predicted risk of mortality score of 2.9%) received ViV TAVI using the Navitor system (Abbott, Chicago, IL, USA) for treatment of failing surgical bioprostheses or THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium 3 (VARC-3) definitions. Results: At 30 days, absence of mortality and VARC-3 adjudicated clinical endpoints were documented. Echocardiography at 30 days revealed complete absence of paravalvular leakage and single-digit mean transvalvular gradients (mean of 6.0 mmHg) in all patients. Conclusion: The investigated intra-annular SE THV results in excellent 30-day outcomes for aortic ViV procedures for failing surgical bioprostheses or THV. Despite the intra-annular design, hemodynamic results were excellent, even in small bioprostheses. Ease of use of this valve platform is reflected by only two cycles of resheathing in five ViV procedures with hemodynamic stability during all steps of valve deployment.

16.
Am J Cardiol ; 201: 349-358, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37423004

RESUMO

Transcatheter aortic valve replacement (TAVR) is an established therapy for severe, symptomatic aortic valve stenosis even in patients with impaired left ventricular systolic function. However, there is uncertainty on the clinical effectiveness of the currently available TAVR devices in patients with reduced left ventricular ejection fraction (LVEF). The LOSTAVI (Low Systolic function and Transcatheter Aortic Valve Implantation) registry is a retrospective observational study using baseline, procedural, discharge, and long-term follow-up details. A total of 3 groups of interest were distinguished: extremely reduced LVEF (<25%), severely reduced LVEF (25% to 30%), and reduced LVEF (31% to 35%). Unadjusted and adjusted analyses were carried out for in-hospital and follow-up outcomes. A total of 923 patients were included from 12 centers, with 146 patients (16%) with LVEF <25%, 425 (46%) with LVEF 25% to 30%, and 352 (38%) with LVEF 31% to 35%. Several baseline and procedural features were different across groups, including age, risk, functional class, and prevalence of bicuspid disease (all p <0.05). In-hospital mortality was similar in the 3 groups (7 [4.8%], 18 [4.2%], and 7 [2.0%], respectively, p = 0.661), but major adverse events were more common in those with extremely reduced and severely reduced LVEF (19 [13%], 53 [13%], and 25 [7.1%], respectively, p = 0.024). The 12-month follow-up confirmed the significant detrimental impact of reduced LVEF on both death (21 [14%], 49 [12%], and 25 [7.1%], respectively, p = 0.024) and major adverse events (37 [25%], 89 [21%], and 53 [15%], respectively, p = 0.016). The adjusted analysis confirmed the significant prognostic role of LVEF on both outcomes, whereas TAVR device type was not associated with death or major adverse events (all p >0.05). In conclusion, TAVR yields favorable early and 1-year results in patients with reduced LVEF, including those with extremely depressed systolic dysfunction. However, reduced LVEF still represents a major adverse prognostic factor for both short- and mid-term outcomes.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda , Substituição da Valva Aórtica Transcateter/métodos , Volume Sistólico , Resultado do Tratamento , Sistema de Registros , Estudos Retrospectivos , Valva Aórtica/cirurgia
17.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-37225288

RESUMO

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Assuntos
Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Sistema de Registros
18.
Eur J Cardiothorac Surg ; 62(1)2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35511127

RESUMO

OBJECTIVES: The major drawback of isolated annuloplasty for treatment of secondary mitral regurgitation (SMR) with restricted leaflet motion during systole (type IIIb) is the recurrence of SMR, leading to adverse clinical outcome. Additional papillary muscle relocation (PMR) specifically addresses leaflet tethering to restore mitral valve geometry. We aimed to compare the 2-year outcome of annuloplasty with additional PMR vs isolated annuloplasty. METHODS: A total of 105 consecutive type IIIb SMR patients with preoperative left ventricular (LV) ejection faction <45%, left ventricular end-diastolic diameter >55 mm and a tenting height >10 mm reached 2-year postoperative follow-up after mitral valve repair and were included in the current analysis. A total of 51 patients underwent annuloplasty and additional PMR (study group). A total of 54 patients underwent isolated annuloplasty (control group). Primary composite study end point comprised death or recurrence of mitral regurgitation ≥2 at 2 years postoperatively. RESULTS: Echocardiographic baseline variables indicating the severity of LV dysfunction and mitral leaflet tethering were similar. Procedural and periprocedural outcome was comparable in both groups. The primary composite end point was significantly improved in the study group (19.6% [10/51]) in comparison to the control group (44.4% [24/54]; P = 0.009). Two-year all-cause mortality was 7.8% [4/51] in the study group vs 18.5% [10/54] in the control group (P = 0.098). After 2 years, a significant improvement in New York Heart Association functional class as compared to the baseline values was observed in the study group. CONCLUSIONS: Additional PMR to treat SMR type IIIb resulted in an improved 2-year outcome in comparison to isolated annuloplasty. PMR specifically addressing mitral leaflet tethering represents a valid therapeutic option for heart failure patients with SMR type IIIb.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Ecocardiografia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/métodos , Músculos Papilares/cirurgia , Resultado do Tratamento
19.
Innovations (Phila) ; 17(4): 317-323, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35983699

RESUMO

Objective: Subannular mitral valve (MV) repair techniques have been developed to address increased rates of recurrent mitral regurgitation (MR) in patients with secondary MR (SMR) type IIIb. Endoscopic papillary muscle relocation (PMR) is feasible via minithoracotomy. Nevertheless, the periprocedural outcome of patients with severe left ventricular (LV) dysfunction remains unknown. Methods: A total of 98 consecutive patients with SMR type IIIb underwent PMR at our institution. Due to concomitant coronary artery bypass grafting, 62 patients underwent sternotomy and were excluded from the current analysis, whereas 36 patients were treated by a minimally invasive technique using 3-dimensional endoscopy. Of these, 18 patients had severely depressed LV ejection fraction (LVEF) ≤35% (study group) and were compared to the remaining 18 patients with LVEF >35% (control group). Periprocedural outcome was retrospectively analyzed. Results: Although LVEF was significantly worse in the study group (30% ± 4% vs 43% ± 6%, P < 0.001), the severity of SMR and the degree of MV leaflet tethering were similar. The prevalence of concomitant procedures and the duration of surgery, cardiopulmonary bypass, and aortic cross-clamp were comparable. Periprocedural low cardiac output syndrome was favorably low in both groups (16.7% vs 5.6%, P = 0.29). Postoperative ventilation time (5.7 h [4.2 to 8.7 h] vs 6.0 h [4.6 to 9.8 h], P = 0.43) and duration of intensive care unit stay (2 days [1 to 3 days] vs 2 days [1 to 3 days], P = 0.22) were similar. There was no 30-day mortality in either group. Conclusions: Standardized endoscopic PMR resulted in favorable periprocedural outcomes in patients with severe LV dysfunction, suggesting that minimally invasive surgery can safely be extended to this patient population.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Endoscopia , Humanos , Anuloplastia da Valva Mitral/métodos , Músculos Papilares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/cirurgia
20.
Am J Cardiol ; 171: 115-121, 2022 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-35307189

RESUMO

As valve-in-valve (ViV) transcatheter aortic valve implantation is still an evolving method, we evaluated the development of early and midterm outcomes after ViV and conventional redo-surgical aortic valve replacement (SAVR) over the past 2 decades. In-hospital databases were retrospectively screened for patients ≥60 years treated for failing bioprosthetic aortic valves at our center. Clinical and follow-up characteristics were compared between patients who underwent ViV or redo-SAVR according to valve academic research consortium-2 (VARC-2) definitions. The comparison of outcome parameters was adjusted for baseline differences between groups. Between June 2002 and April 2020, 209 patients with ViV and 65 redo-SAVR patients met inclusion criteria. No significant differences were found in 30 days (ViV 3.8%, SAVR 3.1%, p = 0.778) or 6-month mortality (ViV 14.0%, SAVR 7.5%, p = 0.283). As patients with ViV less frequently experienced acute kidney injury (stage II or III) and life-threatening bleeding, they more frequently reached the 30-day VARC-2 combined safety end point (79.2% vs 61.5%, odds ratio [OR] 2.540, p = 0.023). Patients with ViV less frequently reached clinical efficacy (68.3% vs 84.6%, OR 0.408, p = 0.041) and device success (79.9% vs 92.3%, OR 0.311, p = 0.040) end points, because of higher frequency of postprocedural transvalvular gradients >20 mm Hg. However, over the past decade, VARC-2 clinical efficacy and device success rates continuously increased in ViV cases. In conclusion, ViV and SAVR were associated with similar acute mortality and different beneficial and adverse outcome profiles in this single-center cohort. Results after ViV procedures have continuously improved over the past years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Reoperação , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA