Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Magn Reson Med ; 90(6): 2510-2523, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37526134

RESUMO

PURPOSE: After epicardial cardiac implantable electronic devices are implanted in pediatric patients, they become ineligible to receive MRI exams due to an elevated risk of RF heating. We investigated whether simple modifications in the trajectories of epicardial leads could substantially and reliably reduce RF heating during MRI at 1.5 T, with benefits extending to abandoned leads. METHODS: Electromagnetic simulations were performed to assess RF heating of two common 35-cm epicardial lead trajectories exhibiting different degrees of coupling with MRI incident electric fields. Experiments in anthropomorphic phantoms implanted with commercial cardiac implantable electronic devices confirmed the findings. Both electromagnetic simulations and experimental measurements were performed using head-first and feet-first positioning and various landmarks. Transfer function approach was used to assess the performance of suggested modifications in realistic body models. RESULTS: Simulations (head-first, chest landmark) of a 35-cm epicardial lead with a trajectory where the excess length of the lead was looped and placed on the inferior surface of the heart showed an 87-fold reduction in the 0.1 g-averaged specific absorption rate compared with the lead where the excess length was looped on the anterior surface. Repeated experiments with a commercial epicardial device confirmed this. For fully implanted systems following low-specific absorption rate trajectories, there was a 16-fold reduction in the average temperature rise and a 28-fold reduction for abandoned leads. The transfer function method predicted a 7-fold reduction in the RF heating in 336 realistic scenarios. CONCLUSION: Surgical modification of epicardial lead trajectory can substantially reduce RF heating at 1.5 T, with benefits extending to abandoned leads.


Assuntos
Calefação , Próteses e Implantes , Humanos , Criança , Coração , Temperatura , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Temperatura Alta
2.
Stereotact Funct Neurosurg ; 101(1): 47-59, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36529124

RESUMO

INTRODUCTION: Deep brain stimulation (DBS) is a common treatment for a variety of neurological and psychiatric disorders. Recent studies have highlighted the role of neuroimaging in localizing the position of electrode contacts relative to target brain areas in order to optimize DBS programming. Among different imaging methods, postoperative magnetic resonance imaging (MRI) has been widely used for DBS electrode localization; however, the geometrical distortion induced by the lead limits its accuracy. In this work, we investigated to what degree the difference between the actual location of the lead's tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters such as acquisition plane and phase encoding direction, as well as the lead's extracranial configuration. Accordingly, an imaging technique to increase the accuracy of lead localization was devised and discussed. METHODS: We designed and constructed an anthropomorphic phantom with an implanted DBS system following 18 clinically relevant configurations. The phantom was scanned at a Siemens 1.5 Tesla Aera scanner using a T1MPRAGE sequence optimized for clinical use and a T1TSE sequence optimized for research purposes. We varied slice acquisition plane and phase encoding direction and calculated the distance between the caudal tip of the DBS lead MRI artifact and the actual tip of the lead, as estimated from MRI reference markers. RESULTS: Imaging parameters and lead configuration substantially altered the difference in the depth of the lead within its MRI artifact on the scale of several millimeters - with a difference as large as 4.99 mm. The actual tip of the DBS lead was found to be consistently more rostral than the tip estimated from the MR image artifact. The smallest difference between the tip of the DBS lead and the tip of the MRI artifact using the clinically relevant sequence (i.e., T1MPRAGE) was found with the sagittal acquisition plane and anterior-posterior phase encoding direction. DISCUSSION/CONCLUSION: The actual tip of an implanted DBS lead is located up to several millimeters rostral to the tip of the lead's artifact on postoperative MR images. This distance depends on the MRI sequence parameters and the DBS system's extracranial trajectory. MRI parameters may be altered to improve this localization.


Assuntos
Estimulação Encefálica Profunda , Humanos , Estimulação Encefálica Profunda/métodos , Artefatos , Eletrodos Implantados , Imageamento por Ressonância Magnética/métodos , Encéfalo/patologia
3.
Magn Reson Med ; 87(6): 2933-2946, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35092097

RESUMO

PURPOSE: In this study, the effects of RF coupling on the magnitude and spatial patterns of RF-induced heating near multiple wire-like conducting implants (such as simultaneous electrical stimulation of stereoelectroencephalography electrodes) during MRI were assessed. METHODS: Simulations and experimental measurements of RF-induced temperature increases near partially immersed wire-like conductors were performed using a phantom with a transmit/receive head coil on a 3T MRI system. The conductors consisted of either a pair of wires or a single simultaneous electrical stimulation of stereoelectroencephalography electrode with multiple contacts, and the locations and lengths of the conductors were varied to study the effect of electromagnetic coupling on RF-induced heating. RESULTS: The temperature increase near a wire within the phantom was dependent not only on its own location and length, but also on the locations and lengths of the other partially immersed wires. In the configurations that were studied, the presence of a second implant could increase the heating near the tip of the conductor by as much as 95%. CONCLUSION: The level of RF-induced heating during an MR scan is affected significantly by RF coupling when more than one wire-like implant is present. In some of the configurations studied, the heating was increased by the presence of a second conductor partially immersed in the phantom. Thus, RF coupling is an important factor to consider in the assessment of safety issues for MRI when multiple implants are present.


Assuntos
Calefação , Ondas de Rádio , Eletrodos , Temperatura Alta , Imageamento por Ressonância Magnética , Imagens de Fantasmas
4.
Magn Reson Med ; 87(5): 2464-2480, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34958685

RESUMO

PURPOSE: To evaluate the safety of MRI in patients with fragmented retained leads (FRLs) through numerical simulation and phantom experiments. METHODS: Electromagnetic and thermal simulations were performed to determine the worst-case RF heating of 10 patient-derived FRL models during MRI at 1.5 T and 3 T and at imaging landmarks corresponding to head, chest, and abdomen. RF heating measurements were performed in phantoms implanted with reconstructed FRL models that produced highest heating in numerical simulations. The potential for unintended tissue stimulation was assessed through a conservative estimation of the electric field induced in the tissue due to gradient-induced voltages developed along the length of FRLs. RESULTS: In simulations under conservative approach, RF exposure at B1+ ≤ 2 µT generated cumulative equivalent minutes (CEM)43 < 40 at all imaging landmarks at both 1.5 T and 3 T, indicating no thermal damage for acquisition times (TAs) < 10 min. In experiments, the maximum temperature rise when FRLs were positioned at the location of maximum electric field exposure was measured to be 2.4°C at 3 T and 2.1°C at 1.5 T. Electric fields induced in the tissue due to gradient-induced voltages remained below the threshold for cardiac tissue stimulation in all cases. CONCLUSIONS: Simulation and experimental results indicate that patients with FRLs can be scanned safely at both 1.5 T and 3 T with most clinical pulse sequences.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Coração/diagnóstico por imagem , Calefação , Temperatura Alta , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
5.
Magn Reson Med ; 86(3): 1560-1572, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33961301

RESUMO

PURPOSE: Patients with active implants such as deep brain stimulation (DBS) devices are often denied access to MRI due to safety concerns associated with the radiofrequency (RF) heating of their electrodes. The majority of studies on RF heating of conductive implants have been performed in horizontal close-bore MRI scanners. Vertical MRI scanners which have a 90° rotated transmit coil generate fundamentally different electric and magnetic field distributions, yet very little is known about RF heating of implants in this class of scanners. We performed numerical simulations as well as phantom experiments to compare RF heating of DBS implants in a 1.2T vertical scanner (OASIS, Hitachi) compared to a 1.5T horizontal scanner (Aera, Siemens). METHODS: Simulations were performed on 90 lead models created from post-operative CT images of patients with DBS implants. Experiments were performed with wires and commercial DBS devices implanted in an anthropomorphic phantom. RESULTS: We found significant reduction of 0.1 g-averaged specific absorption rate (30-fold, P < 1 × 10-5 ) and RF heating (9-fold, P < .026) in the 1.2T vertical scanner compared to the 1.5T conventional scanner. CONCLUSION: Vertical MRI scanners appear to generate lower RF heating around DBS leads, providing potentially heightened safety or the flexibility to use sequences with higher power levels than on conventional systems.


Assuntos
Estimulação Encefálica Profunda , Eletrodos Implantados , Temperatura Alta , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ondas de Rádio
6.
J Magn Reson Imaging ; 53(2): 599-610, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32860322

RESUMO

BACKGROUND: Patients with deep brain stimulation (DBS) implants have limited access to MRI due to safety concerns associated with RF-induced heating. Currently, MRI in these patients is allowed in 1.5T horizontal bore scanners utilizing pulse sequences with reduced power. However, the use of 3T MRI in such patients is increasingly reported based on limited safety assessments. Here we present the results of comprehensive RF heating measurements for two commercially available DBS systems during MRI at 1.5T and 3T. PURPOSE: To assess the effect of imaging landmark, DBS lead configuration, and patient's body composition on RF heating of DBS leads during MRI at 1.5T and 3T. STUDY TYPE: Phantom and ex vivo study. POPULATION/SUBJECTS/PHANTOM/SPECIMEN/ANIMAL MODEL: Gel phantoms and cadaver brain. FIELD STRENGTH/SEQUENCE: 1.5T and 3T, T1 -weighted turbo spin echo. ASSESSMENT: RF heating was measured at the tips of DBS leads implanted in brain-mimicking gel. Image artifact was assessed in a cadaver brain implanted with an isolated DBS lead. STATISTICAL TESTS: Descriptive. RESULTS: We observed substantial fluctuation in RF heating, mainly affected by phantom composition and DBS lead configuration, ranging from 0.14°C to 23.73°C at 1.5T, and from 0.10°C to 7.39°C at 3T. The presence of subcutaneous fat substantially altered RF heating at the electrode tips (3.06°C < ∆T < 19.05° C). Introducing concentric loops in the extracranial portion of the lead at the surgical burr hole reduced RF heating by up to 89% at 1.5T and up to 98% at 3T compared to worst-case heating scenarios. DATA CONCLUSION: Device configuration and patient's body composition substantially altered the RF heating of DBS leads during MRI. Interestingly, certain lead trajectories consistently reduced RF heating and image artifact. Level of Evidence 1 Technical Efficacy Stage 1 J. MAGN. RESON. IMAGING 2021;53:599-610.


Assuntos
Estimulação Encefálica Profunda , Calefação , Artefatos , Composição Corporal , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
7.
IEEE Trans Electromagn Compat ; 63(5): 1757-1766, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34898696

RESUMO

Interaction of an active electronic implant such as a deep brain stimulation (DBS) system and MRI RF fields can induce excessive tissue heating, limiting MRI accessibility. Efforts to quantify RF heating mostly rely on electromagnetic (EM) simulations to assess individualized specific absorption rate (SAR), but such simulations require extensive computational resources. Here, we investigate if a predictive model using machine learning (ML) can predict the local SAR in the tissue around tips of implanted leads from the distribution of the tangential component of the MRI incident electric field, Etan. A dataset of 260 unique patient-derived and artificial DBS lead trajectories was constructed, and the 1 g-averaged SAR, 1gSARmax, at the lead-tip during 1.5 T MRI was determined by EM simulations. Etan values along each lead's trajectory and the simulated SAR values were used to train and test the ML algorithm. The resulting predictions of the ML algorithm indicated that the distribution of Etan could effectively predict 1gSARmax at the DBS lead-tip (R = 0.82). Our results indicate that ML has the potential to provide a fast method for predicting MR-induced power absorption in the tissue around tips of implanted leads such as those in active electronic medical devices.

8.
Magn Reson Med ; 80(4): 1676-1685, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29468721

RESUMO

PURPOSE: To assess RF-induced heating during MRI of patients with implanted stereo-electroencephalography electrodes. METHODS: Simulations and experimental measurements using phantom and a head-only transmit/receive coil on a 3T MR system were performed to evaluate temperature increases at the tip of an 8-contact stereo-electroencephalography electrode and an insulated wire partially immersed into the phantom. The lengths of wire producing maximum (resonant condition) and minimum (anti-resonant condition) heating were evaluated for different entry modes and penetration depths. RESULTS: For both wire and stereo-electroencephalography electrode, resonant lengths were close to odd integral multiples of RF quarter wavelength in air and antiresonant length close to even integral multiples of RF quarter wavelength, both being unaffected by the entry mode. In the resonant condition, temperature increased by as much as a factor of 10 higher than that at antiresonant condition. Larger penetration depths did not change resonant length, but did lead to increased RF heating. CONCLUSION: For the partially immersed implants like stereo-electroencephalography electrode, the resonant lengths were found to be independent of the penetration depths and entry modes, although the temperature increases may vary. Avoiding such lengths of cables can reduce the risk of tissue heating during in vivo MRI.


Assuntos
Eletroencefalografia/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Cobre , Eletrodos Implantados , Cabeça/diagnóstico por imagem , Temperatura Alta , Humanos , Modelos Biológicos , Imagens de Fantasmas , Ondas de Rádio , Processamento de Sinais Assistido por Computador , Termografia
9.
Artigo em Inglês | MEDLINE | ID: mdl-38083021

RESUMO

Advances in low-field magnetic resonance imaging (MRI) are making imaging more accessible without significant losses in image quality. In addition to being more cost-effective and easier to place without as much needed infrastructure, it has been publicized that the lower field strengths make MRI safer for patients with implants. To test this claim, we conducted a total of 368 simulations with wires of various lengths and geometries in a gel phantom during radiofrequency (RF) exposure at 23 MHz and 63.6 MHz (corresponding to MRI at 0.55 T and 1.5 T). Our results showed that heating in the gel around wire tips could be higher in certain cases at 0.55 T. To examine the impact on real patients, we simulated two models of patients with deep brain stimulation (DBS) implants of different lengths. These simulations provide quantitative evidence that low-field MRI is not always safer, and this paper serves to illustrate some of the basic principles involved in RF heating of elongated implants in MRI environments.Clinical Relevance- This paper illustrates the physical concepts of resonance and inductive coupling in RF heating during MRI scanning with implants through systematic simulations and discusses the impact of these principles in practice.


Assuntos
Estimulação Encefálica Profunda , Humanos , Calefação , Temperatura Alta , Próteses e Implantes , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos
10.
Artigo em Inglês | MEDLINE | ID: mdl-38082747

RESUMO

Deep brain stimulation (DBS) has proven to be an effective treatment for Parkinson's disease and other brain disorders. The procedure often involves implanting two elongated leads aimed at specific brain nuclei in both the left and right hemispheres. However, evaluating the safety of MRI in patients with such implants has only been done on an individual lead basis, ignoring the possibility of crosstalk between the leads. This study evaluates the impact of crosstalk on power deposition at the lead tip through numerical simulation and phantom experiments. We used CT images to obtain patient-specific lead trajectories and compared the power deposition at the lead tip in cases with bilateral and unilateral DBS implants. Our results indicate that the RF power deposition at the lead tip can vary by up to 6-fold when two DBS leads are present together compared to when only one lead is present. Experimental measurements in a simplified case of two lead-only DBS systems confirmed the existence of crosstalk.Clinical Relevance-Our results indicate that RF heating of implanted leads during MRI can be affected by the presence of another lead in the body, which may increase or decrease the power deposition in the tissue depending on the position and configuration of the leads.


Assuntos
Estimulação Encefálica Profunda , Calefação , Humanos , Próteses e Implantes , Imageamento por Ressonância Magnética/métodos , Simulação por Computador
11.
Artigo em Inglês | MEDLINE | ID: mdl-38082837

RESUMO

The interaction between an active implantable medical device and magnetic resonance imaging (MRI) radiofrequency (RF) fields can cause excessive tissue heating. Existing methods for predicting RF heating in the presence of an implant rely on either extensive phantom experiments or electromagnetic (EM) simulations with varying degrees of approximation of the MR environment, the patient, or the implant. On the contrary, fast MR thermometry techniques can provide a reliable real-time map of temperature rise in the tissue in the vicinity of conductive implants. In this proof-of-concept study, we examined whether a machine learning (ML) based model could predict the temperature increase in the tissue near the tip of an implanted lead after several minutes of RF exposure based on only a few seconds of experimentally measured temperature values. We performed phantom experiments with a commercial deep brain stimulation (DBS) system to train a fully connected feedforward neural network (NN) to predict temperature rise after ~3 minutes of scanning at a 3 T scanner using only data from the first 5 seconds. The NN effectively predicted ΔTmax-R2 = 0.99 for predictions in the test dataset. Our model also showed potential in predicting RF heating for other various scenarios, including a DBS system at a different field strength (1.5 T MRI, R2 = 0.87), different field polarization (1.2 T vertical MRI, R2 = 0.79), and an unseen implant (cardiac leads at 1.5 T MRI, R2 = 0.91). Our results indicate great potential for the application of ML in combination with fast MR thermometry techniques for rapid prediction of RF heating for implants in various MR environments.Clinical Relevance- Machine learning-based algorithms can potentially enable rapid prediction of MRI-induced RF heating in the presence of unknown AIMDs in various MR environments.


Assuntos
Calefação , Próteses e Implantes , Humanos , Temperatura , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos
12.
Artigo em Inglês | MEDLINE | ID: mdl-38083480

RESUMO

Radiofrequency (RF) induced tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during magnetic resonance imaging (MRI), hindering routine protocols for patients. Known factors that contribute to variations in the magnitude of RF heating across patients include the implanted lead's trajectory and its orientation with respect to the MRI electric fields. Currently, there are no consistent requirements for surgically implanting the extracranial portion of the DBS lead. Recent studies have shown that incorporating concentric loops in the extracranial trajectory of the lead can reduce RF heating, but the optimal positioning of the loop is unknown. In this study, we evaluated RF heating of 77 unique lead trajectories to determine how different characteristics of the trajectory affect RF heating during MRI at 3 T. We performed phantom experiments with commercial DBS systems from two manufacturers to determine how consistently modifying the lead trajectory mitigates RF heating. We also presented the first surgical implementation of these modified trajectories in patients. Low-heating trajectories included small concentric loops near the surgical burr hole which were readily implemented during the surgical procedure; these trajectories generated nearly a 2-fold reduction in RF heating compared to unmodified trajectories.Clinical Relevance- Surgically modifying the DBS lead trajectory can be a cost-effective strategy for reducing RF-induced heating during MRI at 3 T.


Assuntos
Estimulação Encefálica Profunda , Humanos , Calefação , Próteses e Implantes , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
13.
J Neurosurg ; : 1-12, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37948679

RESUMO

OBJECTIVE: Radiofrequency (RF) tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during MRI, resulting in strict imaging guidelines and limited allowable protocols. The implanted lead's trajectory and orientation with respect to the MRI electric fields contribute to variations in the magnitude of RF heating across patients. Currently, there are no surgical requirements for implanting the extracranial portion of the DBS lead, resulting in substantial variations in clinical lead trajectories and consequently RF heating. Recent studies have shown that incorporating concentric loops in the extracranial lead trajectory can reduce RF heating. However, optimal positioning of the loops and the quantitative benefit of trajectory modification in terms of added safety margins during MRI remain unknown. In this study, the authors systematically evaluated the characteristics of DBS lead trajectories that minimize RF heating during 3T MRI to develop the best surgical practices for safe access to postoperative MRI, and they present the first surgical implementation of these modified trajectories. METHODS: The authors performed experiments to assess the maximum temperature increase of 244 distinct lead trajectories. They investigated the effect of the position, number, and size of the concentric loops on the skull. Experiments were performed in an anthropomorphic phantom implanted with a commercial DBS system, and RF exposure was generated by applying a high specific absorption rate sequence (B1+rms = 2.7 µT). The authors conducted test-retest experiments to assess the reliability of measurements. Additionally, they evaluated the effect of imaging landmarks and perturbations to the DBS device configuration on the efficacy of low-heating trajectories. Finally, two neurosurgeons implanted the recommended modified trajectories in patients, and the authors characterized their RF heating in comparison with unmodified trajectories. RESULTS: The maximum temperature increase ranged from 0.09°C to 7.34°C. The authors found that increasing the number of loops and positioning them closer to the surgical burr hole, particularly for the contralateral lead, substantially reduced RF heating. These trajectory modifications were easily incorporated during the surgical procedure and resulted in a threefold reduction in RF heating. CONCLUSIONS: Surgically modifying the extracranial portion of the DBS lead trajectory can substantially reduce RF heating during 3T MRI. The authors' results indicate that simple adjustments to the lead's configuration, such as small, concentric loops near the burr hole, can be readily adopted during DBS lead implantation to improve patient safety during MRI.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38082570

RESUMO

There is a paucity of data regarding the safety of magnetic resonance imaging (MRI) in patients with abandoned epicardial leads. Few studies have reported temperature rises up to 76 °C during MRI at 1.5 T in gel phantoms implanted with epicardial leads; however, lead trajectories used in these experiments were not clinically relevant. This work reports patient-specific RF heating of both capped and uncapped abandoned epicardial lead configurations during MRI at both 1.5 T and 3 T field strengths. We found that leads routed along realistic, patient-derived trajectories generated substantially lower RF heating than the previously reported worst-case phantom experiments. We also found that MRI at the head imaging landmark leads to substantially lower RF heating compared to MRI at the chest or abdomen landmarks at both 1.5 T and 3 T. Our results suggest that patients with abandoned epicardial leads may safely undergo MRI for head imaging, but caution is warranted during chest and abdominal imaging.Clinical Relevance- Patients with abandoned epicardial leads may safely undergo MRI for head imaging, but caution is warranted during chest and abdominal imaging.


Assuntos
Calefação , Próteses e Implantes , Humanos , Imagens de Fantasmas , Temperatura , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos
15.
Diagnostics (Basel) ; 13(17)2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37685385

RESUMO

This study focused on the potential risks of radiofrequency-induced heating of cardiac implantable electronic devices (CIEDs) in children and adults with epicardial and endocardial leads of varying lengths during cardiothoracic MRI scans. Infants and young children are the primary recipients of epicardial CIEDs, though the devices have not been approved as MR conditional by the FDA due to limited data, leading to pediatric hospitals either refusing the MRI service to most pediatric CIED patients or adopting a scan-all strategy based on results from adult studies. The study argues that risk-benefit decisions should be made on an individual basis. We used 120 clinically relevant epicardial and endocardial device configurations in adult and pediatric anthropomorphic phantoms to determine the temperature rise during RF exposure at 1.5 T. The results showed that there was significantly higher RF heating of epicardial leads than endocardial leads in the pediatric phantom, but not in the adult phantom. Additionally, body size and lead length significantly affected RF heating, with RF heating up to 12 °C observed in models based on younger children with short epicardial leads. The study provides evidence-based knowledge on RF-induced heating of CIEDs and highlights the importance of making individual risk-benefit decisions when assessing the potential risks of MRI scans in pediatric CIED patients.

16.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4014-4017, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086095

RESUMO

Patients with congenital heart defects, inherited arrhythmia syndromes, and congenital disorders of cardiac conduction often receive a cardiac implantable electronic device (CIED). At least 75% of patients with CIEDs will need magnetic resonance imaging (MRI) during their lifetime. In 2011, the US Food and Drug Administration approved the first MR-conditional CIEDs for patients with endocardial systems, in which leads are passed through the vein and affixed to the endocardium. The majority of children, however, receive an epicardial CIED, where leads are directly sewn to the epicardium. Unfortunately, an epicardial CIED is a relative contraindication to MRI due to the unknown risk of RF heating. In this work, we performed anthropomorphic phantom experiments to investigate differences in RF heating between endocardial and epicardial leads in both pediatric and adult-sized phantoms, where adult endocardial CIED was the control. Clinical Relevance-This work provides a quantitative comparison of MRI RF heating of epicardial and endocardial leads in pediatric and adult populations.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Adulto , Criança , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Endocárdio/diagnóstico por imagem , Calefação , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Pericárdio/diagnóstico por imagem
17.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1863-1866, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086639

RESUMO

Deep brain stimulation (DBS) is an established yet growing treatment for a range of neurological and psychiatric disorders. Over the last decade, numerous studies have underscored the effect of electrode placement on the clinical outcome of DBS. As a result, imaging is now extensively used for DBS electrode localization, even though the accuracy of different modalities in determining the true coordinates of DBS electrodes is less explored. Postoperative magnetic resonance imaging (MRI) is a gold standard method for DBS electrode localization, however, the geometrical distortion induced by the lead's artifact could limit the accuracy. In this work, we investigated to what degree the difference between the true location of the lead's tip and the location of the tip estimated from the MRI artifact varies depending on the MRI sequence parameters, acquisition plane, phase encoding direction, and the implant"s extracranial trajectory. Clinical Relevance- Results will help researchers and clinicians to estimate the true location of DBS leads and contacts from postoperative MRI scans.


Assuntos
Estimulação Encefálica Profunda , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Período Pós-Operatório
18.
PLoS One ; 17(12): e0278187, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36490249

RESUMO

The majority of studies that assess magnetic resonance imaging (MRI) induced radiofrequency (RF) heating of the tissue when active electronic implants are present have been performed in horizontal, closed-bore MRI systems. Vertical, open-bore MRI systems have a 90° rotated magnet and a fundamentally different RF coil geometry, thus generating a substantially different RF field distribution inside the body. Little is known about the RF heating of elongated implants such as deep brain stimulation (DBS) devices in this class of scanners. Here, we conducted the first large-scale experimental study investigating whether RF heating was significantly different in a 1.2 T vertical field MRI scanner (Oasis, Fujifilm Healthcare) compared to a 1.5 T horizontal field MRI scanner (Aera, Siemens Healthineers). A commercial DBS device mimicking 30 realistic patient-derived lead trajectories extracted from postoperative computed tomography images of patients who underwent DBS surgery at our institution was implanted in a multi-material, anthropomorphic phantom. RF heating around the DBS lead was measured during four minutes of high-SAR RF exposure. Additionally, we performed electromagnetic simulations with leads of various internal structures to examine this effect on RF heating. When controlling for RMS B1+, the temperature increase around the DBS lead-tip was significantly lower in the vertical scanner compared to the horizontal scanner (0.33 ± 0.24°C vs. 4.19 ± 2.29°C). Electromagnetic simulations demonstrated up to a 17-fold reduction in the maximum of 0.1g-averaged SAR in the tissue surrounding the lead-tip in the vertical scanner compared to the horizontal scanner. Results were consistent across leads with straight and helical internal wires. Radiofrequency heating and power deposition around the DBS lead-tip were substantially lower in the 1.2 T vertical scanner compared to the 1.5 T horizontal scanner. Simulations with different lead structures suggest that the results may extend to leads from other manufacturers.


Assuntos
Estimulação Encefálica Profunda , Humanos , Estimulação Encefálica Profunda/métodos , Ondas de Rádio , Calefação , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Temperatura Alta
19.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 5000-5003, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086119

RESUMO

Infants and children with congenital heart defects often receive a cardiac implantable electronic device (CIED). Because transvenous access to the heart is difficult in patients with small veins, the majority of young children receive epicardial CIEDs. Unfortunately, however, once an epicardial CIED is placed, patients are no longer eligible to receive magnetic resonance imaging (MRI) exams due to the unknown risk of MRI-induced radiofrequency (RF) heating of the device. Although many studies have assessed the role of device configuration in RF heating of endocardial CIEDs in adults, such case for epicardial devices in pediatric patients is relatively unexplored. In this study, we evaluated the variation in RF heating of an epicardial lead due to changes in the lateral position and orientation of the implantable pulse generator (IPG). We found that changing the orientation and position of the IPG resulted in a five-fold variation in the RF heating at the lead's tip. Maximum heating was observed when the IPG was moved to a left lateral abdominal position of patient, and minimum heating was observed when the IPG was positioned directly under the heart. Clinical Relevance- This study examines the role of device configuration on MRI-induced RF heating of an epicardial CIED in a pediatric phantom. Results could help pediatric cardiac surgeons to modify device implantation to reduce future risks of MRI in patients.


Assuntos
Calefação , Ondas de Rádio , Adulto , Criança , Pré-Escolar , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Próteses e Implantes
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4978-4981, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892325

RESUMO

Radiofrequency (RF) heating of tissue during magnetic resonance imaging (MRI) is a known safety risk in the presence of active implantable medical devices (AIMDs). As a result, access to MRI is limited for patients with these implants including those with deep brain stimulation (DBS) systems. Numerous factors contribute to excessive RF tissue heating at the DBS lead-tip, most notable being the trajectory of the lead. Phantom studies have demonstrated that looping the extracranial portion of the DBS lead at the surgical burr hole reduces the heating at the lead-tip; however, clinical implementation of this technique is challenging due to surgical constraints. As such, the intended looped trajectory is usually different from what is implanted in patients. To date, no data is available to quantify the extent by which surgical trajectory modification reduces RF heating of DBS leads compared to the typical surgical approach. In this work, we measured RF heating of a commercial DBS system during 3 T MRI, where the trajectory of the lead and extension cable mimicked lead trajectories constructed from postoperative CT images of 13 patients undergoing modified DBS surgery and 2 patients with unmodified trajectories. Two manually created trajectories mimicking typical heating cases seen in the literature were also evaluated. We found that modified lead trajectories reduced the average heating by 3-folds compared to unmodified lead trajectories.Clinical Relevance- This study evaluates the performance of a surgical modification in the routing of DBS leads in reducing RF-induced heating during MRI at 3 T.


Assuntos
Estimulação Encefálica Profunda , Calefação , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Ondas de Rádio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA