Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Phys Rev Lett ; 132(15): 152501, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38683002

RESUMO

We report the first mass measurement of the proton-halo candidate ^{22}Al performed with the low energy beam ion trap facility's 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. ^{22}Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of ^{22}Al, Phys. Rev. Lett. 125, 192503 (2020).PRLTAO0031-900710.1103/PhysRevLett.125.192503]. The measured mass excess value of ME=18 092.5(3) keV, corresponding to an exceptionally small proton separation energy of S_{p}=100.4(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from sd-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the ^{22}Al ground state with minimal 1s_{1/2} occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

2.
Phys Rev Lett ; 126(4): 042501, 2021 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-33576685

RESUMO

We report high-precision mass measurements of ^{50-55}Sc isotopes performed at the LEBIT facility at NSCL and at the TITAN facility at TRIUMF. Our results provide a substantial reduction of their uncertainties and indicate significant deviations, up to 0.7 MeV, from the previously recommended mass values for ^{53-55}Sc. The results of this work provide an important update to the description of emerging closed-shell phenomena at neutron numbers N=32 and N=34 above proton-magic Z=20. In particular, they finally enable a complete and precise characterization of the trends in ground state binding energies along the N=32 isotone, confirming that the empirical neutron shell gap energies peak at the doubly magic ^{52}Ca. Moreover, our data, combined with other recent measurements, do not support the existence of a closed neutron shell in ^{55}Sc at N=34. The results were compared to predictions from both ab initio and phenomenological nuclear theories, which all had success describing N=32 neutron shell gap energies but were highly disparate in the description of the N=34 isotone.

3.
Phys Rev Lett ; 123(23): 239905, 2019 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-31868474

RESUMO

This corrects the article DOI: 10.1103/PhysRevLett.120.032701.

4.
Phys Rev Lett ; 120(3): 032701, 2018 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-29400535

RESUMO

We report the mass measurement of ^{56}Cu, using the LEBIT 9.4 T Penning trap mass spectrometer at the National Superconducting Cyclotron Laboratory at Michigan State University. The mass of ^{56}Cu is critical for constraining the reaction rates of the ^{55}Ni(p,γ) ^{56}Cu(p,γ) ^{57}Zn(ß^{+}) ^{57}Cu bypass around the ^{56}Ni waiting point. Previous recommended mass excess values have disagreed by several hundred keV. Our new value, ME=-38626.7(7.1) keV, is a factor of 30 more precise than the extrapolated value suggested in the 2012 atomic mass evaluation [Chin. Phys. C 36, 1603 (2012)CPCHCQ1674-113710.1088/1674-1137/36/12/003], and more than a factor of 12 more precise than values calculated using local mass extrapolations, while agreeing with the newest 2016 atomic mass evaluation value [Chin. Phys. C 41, 030003 (2017)CPCHCQ1674-113710.1088/1674-1137/41/3/030003]. The new experimental average, using our new mass and the value from AME2016, is used to calculate the astrophysical ^{55}Ni(p,γ) and ^{56}Cu(p,γ) forward and reverse rates and perform reaction network calculations of the rp process. These show that the rp-process flow redirects around the ^{56}Ni waiting point through the ^{55}Ni(p,γ) route, allowing it to proceed to higher masses more quickly and resulting in a reduction in ashes around this waiting point and an enhancement to higher-mass ashes.

5.
Phys Rev Lett ; 116(1): 012501, 2016 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-26799013

RESUMO

We report the determination of the Q(EC) value of the mirror transition of (11)C by measuring the atomic masses of (11)C and (11)B using Penning trap mass spectrometry. More than an order of magnitude improvement in precision is achieved as compared to the 2012 Atomic Mass Evaluation (Ame2012) [Chin. Phys. C 36, 1603 (2012)]. This leads to a factor of 3 improvement in the calculated Ft value. Using the new value, Q(EC)=1981.690(61) keV, the uncertainty on Ft is no longer dominated by the uncertainty on the Q(EC) value. Based on this measurement, we provide an updated estimate of the Gamow-Teller to Fermi mixing ratio and standard model values of the correlation coefficients.

6.
Phys Rev Lett ; 114(23): 232502, 2015 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-26196795

RESUMO

We report the first direct measurement of the (14)O superallowed Fermi ß-decay QEC value, the last of the so-called "traditional nine" superallowed Fermi ß decays to be measured with Penning trap mass spectrometry. (14)O, along with the other low-Z superallowed ß emitter, (10)C, is crucial for setting limits on the existence of possible scalar currents. The new ground state QEC value, 5144.364(25) keV, when combined with the energy of the 0(+) daughter state, Ex(0(+))=2312.798(11) keV [F. Ajzenberg-Selove, Nucl. Phys. A523, 1 (1991)], provides a new determination of the superallowed ß-decay QEC value, QEC(sa)=2831.566(28) keV, with an order of magnitude improvement in precision, and a similar improvement to the calculated statistical rate function f. This is used to calculate an improved Ft value of 3073.8(2.8) s.

7.
Rev Sci Instrum ; 94(10)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37815423

RESUMO

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

8.
Vet Comp Orthop Traumatol ; 24(3): 223-7, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21327289

RESUMO

The modified Maquet technique (MMT) uses the same principle as the tibial tuberosity advancement (TTA) for stabilization of the cranial cruciate ligament-deficient stifle in the dog. In the MMT, the tibial tuberosity is advanced in a similar manner to that used in the TTA, however the means by which the tibial crest is stabilized differs. The plate and fork originally described by Montavon et al. are not used (7). The MMT was first described by Maquet for use on humans; it leaves intact a distal bony attachment to the tibial shaft, and the tuberosity is either reinforced or not by a figure-of-eight wire. In this paper, we describe the MMT, and we report the results of our first 20 canine patients with cranial cruciate ligament rupture that were treated by the MMT. Mean clinical bone healing time was 6.8 weeks (range 4 to 12 weeks). The evidence provided by this clinical communication suggests that it is technically possible to achieve an advancement of the tibial tuberosity without the need for a plate. The MMT deserves consideration as a primary treatment option for cranial cruciate ligament rupture in dogs, and further evaluation in large clinical studies. Long-term follow-up and force plate analysis would be necessary to compare the MMT to both the TTA and the tibial plateau levelling osteotomy.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Doenças do Cão/cirurgia , Cães/cirurgia , Procedimentos Cirúrgicos Operatórios/veterinária , Animais , Doenças do Cão/patologia , Procedimentos Cirúrgicos Operatórios/métodos
9.
Rev Sci Instrum ; 79(2 Pt 2): 02A706, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315154

RESUMO

Reacceleration of low-energy rare isotope beams available from gas stopping of fast-fragment beams or from an ISOL target station to energies in the range of 0.3-12 MeV/nucleon is needed for experiments such as low-energy Coulomb excitation and transfer reaction studies and for the precise study of astrophysical reactions. The implementation of charge breeding as a first step in a reaccelerator is a key to obtaining a compact and cost-efficient reacceleration scheme. For highest efficiency it is essential that single charge states are obtained in a short breeding time. A low-emittance beam must be delivered. An electron beam ion trap (EBIT) has the potential to meet these requirements. An EBIT-based charge breeder is presently under design and construction at the NSCL as part of the construction of a reaccelerator for stopped beams from projectile fragmentation. This new facility will have the potential to provide low-energy rare isotope beams not yet available elsewhere.

10.
Gene ; 14(4): 279-87, 1981 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-6170538

RESUMO

A colony bank of yeast dna obtained by cloning HindIII-generated fragments of total yeast nuclear DNA in Escherichia coli K-12 with the vector pBR322, was screened with a radioactive RNA probe enriched for a subset of ribosomal protein mRNAs. The selected recombinant DNA molecules were hybridized with poly(A)-containing mRNA under R-loop conditions. From the DNA-RNA hybrids the respective mRNAs were melted off and translated in vitro in a rabbit reticulocyte cell-free system. The translational products were analyzed by immunoprecipitation with antibodies raised against ribosomal proteins. The identity of the ribosomal protein gene products was further established by electrophoresis on two-dimensional gels. At least 15 recombinant DNA molecules were shown to contain ribosomal protein genes. Four of them, i.e. Y65, Y89, Y113 and Y138, have been characterized preliminarily.


Assuntos
DNA Fúngico/isolamento & purificação , Genes , Proteínas Ribossômicas/genética , Saccharomyces/genética , DNA Recombinante/metabolismo , Eletroforese em Gel de Poliacrilamida , Escherichia coli/genética , Hibridização de Ácido Nucleico , RNA Bacteriano/metabolismo
11.
Gene ; 18(1): 29-37, 1982 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7106563

RESUMO

From a colony bank of HindIII-generated yeast DNA fragments we have isolated a number of recombinant DNAs carrying genes for ribosomal proteins (e.g., S10, S16A, S20, S24, S31, S33, L16, L25 and L34) of the yeast Saccharomyces carlsbergensis. By electron microscopic analysis of the R-loops formed between various DNA fragments and yeast mRNA, we could locate the ribosomal protein genes on the physical maps of the cloned DNA fragments. The R-loop structures observed indicate that a number of the ribosomal protein genes contain an intervening sequence.


Assuntos
Proteínas Ribossômicas/genética , Saccharomyces/genética , Sequência de Bases , Clonagem Molecular , DNA Fúngico/genética , Genes , Hibridização de Ácido Nucleico
12.
Phytopathology ; 88(8): 764-73, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18944881

RESUMO

ABSTRACT Compost made from organic household and garden waste was used to substitute part of the peat in potting mixtures used for growing woody ornamental nursery stock. The effects of amendment with compost on the colonization of potting mixture by Rhizoctonia solani (AG1) were studied in greenhouse experiments. A bioassay was developed using cucumber as a sensitive herbaceous test plant as a substitute for woody ornamental cuttings. Pathogen growth in the potting mixture was estimated by measuring the distance over which damping-off of seedlings occurred. Compost from two commercial composting facilities suppressed growth of R. solani in potting mixtures with 20% of the product when the compost was fresh (directly after delivery) or long matured (after 5 to 7 months of additional curing). In contrast, short-matured compost (1 month of additional curing) from the same batches stimulated pathogen growth. In vitro mycelial growth of R. solani on mixtures with mature compost was inhibited by microbial antagonism. Compost-amended potting mixtures responded differentially to the addition of cellulose powder; the effect on suppressiveness depended on curing time and origin of the compost. In long-matured compost, suppressiveness to R. solani was associated with high population densities of cellulolytic and oligotrophic actinomycetes. The ratio of the population density of actinomycetes to that of other bacteria was around 200-fold higher in mature suppressive compost than in conducive compost.

13.
Phytopathology ; 90(3): 253-9, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18944617

RESUMO

ABSTRACT A new method for the control of soilborne plant pathogens was tested for its efficacy in two field experiments during two years. Plots were amended with fresh broccoli or grass (3.4 to 4.0 kg fresh weight m(-2)) or left nonamended, and covered with an airtight plastic cover (0.135 mm thick) or left noncovered. In plots amended with broccoli or grass and covered with plastic sheeting, anaerobic and strongly reducing soil conditions developed quickly, as indicated by rapid depletion of oxygen and a decrease in redox potential values to as low as -200 mV. After 15 weeks, survival of Fusarium oxysporum f. sp. asparagi, Rhizoctonia solani, and Verticillium dahliae in inoculum samples buried 15 cm deep was strongly reduced in amended, covered plots in both experiments. The pathogens were not or hardly inactivated in amended, noncovered soil or nonamended, covered soil. The latter indicates that thermal inactivation due to increased soil temperatures under the plastic cover was not involved in pathogen inactivation. The results show the potential for this approach to control various soilborne pathogens and that it may serve as an alternative to chemical soil disinfestation for high-value crops under conditions where other alternatives, such as solarization or soil flooding, are not effective or not feasible.

14.
Rev Sci Instrum ; 85(2): 02B701, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593600

RESUMO

An electron-beam ion trap (EBIT) charge breeder is being brought into operation at the National Superconducting Cyclotron Laboratory at Michigan State University. The EBIT is part of the ReA post-accelerator for reacceleration of rare isotopes, which are thermalized in a gas "stopping" cell after being produced at high energy by projectile fragmentation. The ReA EBIT has a distinctive design; it is characterized by a high-current electron gun and a two-field superconducting magnet to optimize the capture and charge-breeding efficiency of continuously injected singly charged ion beams. Following a brief overview of the reaccelerator system and the ReA EBIT, this paper presents the latest commissioning results, particularly, charge breeding and reacceleration of the highly charged rare isotopes, (76)Ga(24 +, 25 +).

15.
Rev Sci Instrum ; 85(9): 093503, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25273722

RESUMO

A new data acquisition system including a Field Programmable Gate Array (FPGA) based time-resolved scaler was developed for laser-induced fluorescence and beam bunch coincidence measurements. The FPGA scaler was tested in a collinear laser-spectroscopy experiment on radioactive (37)K at the BEam COoler and LAser spectroscopy (BECOLA) facility at the National Superconducting Cyclotron Laboratory at Michigan State University. A 1.29 µs bunch width from the buncher and a bunch repetition rate of 2.5 Hz led to a background suppression factor of 3.1 × 10(5) in resonant photon detection measurements. The hyperfine structure of (37)K and its isotope shift relative to the stable (39)K were determined using 5 × 10(4) s(-1) (37)K ions injected into the BECOLA beam line. The obtained hyperfine coupling constants A((2)S(1/2)) = 120.3(1.4) MHz, A((2)P(1/2)) = 15.2(1.1) MHz, and A((2)P(3/2)) = 1.4(8) MHz, and the isotope shift δν(39, 37) = -264(3) MHz are consistent with the previously determined values, where available.

16.
Rev Sci Instrum ; 83(2): 02A908, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380249

RESUMO

The ReA reaccelerator is being added to the National Superconducting Cyclotron Laboratory (NSCL) fragmentation facility in order to provide exotic rare-isotope beams, not available at the Isotope Separation On-Line facilities, in the several-MeV/u energy range. The first stage of the NSCL reaccelerator complex, consisting of an EBIT charge breeder, a room-temperature radiofrequency quadrupole (RFQ) accelerator, and superconducting linear accelerator modules, has been completed and is being put into operation. Commissioning of the EBIT has started by extracting charge-bred residual gas ions, ions created from a Ne gas jet directed across the EBIT's electron beam and ions captured from an external test ion source. Charge-bred ions from the Ne gas jet have been extracted as a pulse and accelerated through the RFQ and the two cryomodules.

17.
Rev Sci Instrum ; 81(2): 02A503, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192358

RESUMO

NSCL is currently constructing the ReA3 reaccelerator, which will accelerate rare isotopes obtained from gas stopping of fast-fragment beams to energies of up to 3 MeV/u for uranium and higher for lighter ions. A high-current charge breeder, based on an electron beam ion trap (EBIT), has been chosen as the first step in the acceleration process, as it has the potential to efficiently produce highly charged ions in a single charge state. These ions are fed into a compact linear accelerator consisting of a radio frequency quadrupole structure and superconducting cavities. The NSCL EBIT has been fully designed with most of the parts constructed. The design concept of the EBIT and results from initial commissioning tests of the electron gun and collector with a temporary 0.4 T magnet are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA