RESUMO

OBJECTIVES: The aim of this study was to investigate potential associations between changes in liver volume, the amount of intrahepatic lipids (IHL) and body weight during lifestyle interventions. MATERIAL AND METHODS: In a prospective study 150 patients with an increased risk for developing type 2 diabetes mellitus were included who followed a caloric restriction diet for 6 months. In the retrospective analysis 18 women and 9 men (age range 22-71 years) with an average body mass index (BMI) of 32 kg/m(2) were enrolled. The liver volume was determined at the beginning and after 6 months by three-dimensional magnetic resonance imaging (3D-MRI, echo gradient, opposed-phase) and IHLs were quantified by volume-selective MR spectroscopy in single voxel stimulated echo acquisition mode (STEAM). Univariable and multivariable correlation analyses between changes of liver volume (Δliver volume), intrahepatic lipids (ΔIHL) and body weight (ΔBW) were performed. RESULTS: Univariable correlation analysis in the whole study cohort showed associations between ΔIHL and ΔBW (r = 0.69; p < 0.0001), ΔIHL and Δliver volume (r = 0.66; p = 0.0002) as well as ΔBW and Δliver volume (r = 0.5; p = 0.0073). Multivariable correlation analysis revealed that changes of liver volume are primarily determined by changes in IHL independent of changes in body weight (ß = 0.0272; 95% CI: 0.0155-0.034; p < 0.0001). CONCLUSION: Changes of liver volume during lifestyle interventions are independent of changes of body weight primarily determined by changes of IHL. These results show the reversibility of augmented liver volume in steatosis if it is possible to reduce IHLs during lifestyle interventions.


Assuntos
Peso Corporal , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/prevenção & controle , Gordura Intra-Abdominal/patologia , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Diabetes Mellitus Tipo 2/fisiopatologia , Humanos , Pessoa de Meia-Idade , Tamanho do Órgão , Reprodutibilidade dos Testes , Comportamento de Redução do Risco , Sensibilidade e Especificidade , Resultado do Tratamento
2.
Radiologe ; 55(4): 314-22, 2015 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-25809927

RESUMO

OBJECTIVES: Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. MATERIAL AND METHODS: In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. RESULTS: Among the 30 subjects included in the analysis (83% male, mean age 70.0 ± 10.5 years, 83% diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30%). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100% and 93.1%, respectively) and MIP images (99% and 91.8%, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1% vs. 99.2 vs. 90.9%; respectively, p < 0.001). CONCLUSION: The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs.


Assuntos
Angiografia/métodos , Angiopatias Diabéticas/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Rofo ; 188(12): 1163-1168, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27907941

RESUMO

Purpose: To evaluate the effects of a new frequency selective non-linear blending (NLB) algorithm on the contrast resolution of liver CT with low intravascular concentration of iodine contrast. Materials and Methods: Our local ethics committee approved this retrospective study. The informed consent requirement was waived. CT exams of 25 patients (60 % female, mean age: 65 ±â€Š16 years of age) with late phase CT scans of the liver were included as a model for poor intrahepatic vascular contrast enhancement. Optimal post-processing settings to enhance the contrast of hepatic vessels were determined. Outcome variables included signal-to-noise (SNR) and contrast-to-noise ratios (CNR) of hepatic vessels and SNR of liver parenchyma of standard and post-processed images. Image quality was quantified by two independent readers using Likert scales. Results: The post-processing settings for the visualization of hepatic vasculature were optimal at a center of 115HU, delta of 25HU, and slope of 5. Image noise was statistically indifferent between standard and post-processed images. The CNR between the hepatic vasculature (HV) and liver parenchyma could be significantly increased for liver veins (CNRStandard 1.62 ±â€Š1.10, CNRNLB 3.6 ±â€Š2.94, p = 0.0002) and portal veins (CNRStandard 1.31 ±â€Š0.85, CNRNLB 2.42 ±â€Š3.03, p = 0.046). The SNR of liver parenchyma was significantly higher on post-processed images (SNRNLB 11.26 ±â€Š3.16, SNRStandard 8.85 ± 2.27, p = 0.008). The overall image quality and depiction of HV were significantly higher on post-processed images (NLBDHV: 4 [3 - 4.75], StandardDHV: 2 [1.3 - 2.5], p = < 0.0001; NLBIQ: 4 [4 - 4], StandardIQ: 2 [2 - 3], p = < 0.0001). Conclusion: The use of a frequency selective non-linear blending algorithm increases the contrast resolution of liver CT and can improve the visibility of the hepatic vasculature in the setting of a low contrast ratio between vessels and the parenchyma. Key Points: • Using the new frequency selective non-linear blending algorithm is feasible in contrast-enhanced liver CT.• Optimal post-processing settings make it possible to significantly increase the contrast resolution of liver CT without affecting image noise.• Especially in low contrast CT images, the novel algorithm is capable of significantly increasing image quality. Citation Format: • Bongers MN, Bier G, Kloth C et al. Frequency Selective Non-Linear Blending to Improve Image Quality in Liver CT. Fortschr Röntgenstr 2016; 188: 1163 - 1168.


Assuntos
Algoritmos , Artéria Hepática/diagnóstico por imagem , Veias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Dinâmica não Linear , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade