Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 49(9): 1439-46, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21702699

RESUMO

Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.


Assuntos
Fosfatase Alcalina/metabolismo , Ensaios Enzimáticos/normas , Enzimas , Agências Internacionais/normas , Temperatura , Adolescente , Adulto , Calibragem , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Projetos de Pesquisa , Soluções , Adulto Jovem
2.
Clin Chem Lab Med ; 48(6): 795-803, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20441466

RESUMO

BACKGROUND: A new reference material for the liver enzyme aspartate transaminase (AST) (L-aspartate: 2-oxoglutarate-aminotransferase, EC 2.6.1.1), also called aspartate aminotransferase (ASAT), has been developed under the code ERM-AD457/IFCC. This certified reference material (CRM) for AST has been produced from a human type recombinant AST expressed in Escherichia coli and a buffer containing bovine serum albumin, and has been lyophilised. METHODS: The homogeneity and the stability of the material have been tested and the catalytic activity concentration has been characterised by 12 laboratories using the reference procedure for AST at 37 degrees C from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). RESULTS: The certified catalytic activity concentration and certified uncertainty of AST in the reconstituted material are (1.74+/-0.05) microkat/L or (104.6+/-2.7) U/L (with a coverage factor k=2; 95% confidence interval). CONCLUSIONS: Both the certified value and uncertainty are traceable to the International System of Units (SI). The material is aiming to control the IFCC reference procedure for AST at 37 degrees C, which will then be used to assign values to calibrants and control materials. The present paper highlights the scientific challenges and innovations which were encountered during the development of this new CRM.


Assuntos
Aspartato Aminotransferases/normas , Ensaios Enzimáticos Clínicos/normas , Animais , Aspartato Aminotransferases/análise , Aspartato Aminotransferases/genética , Bovinos , Ensaios Enzimáticos Clínicos/métodos , Humanos , Proteínas Recombinantes/análise , Proteínas Recombinantes/genética , Proteínas Recombinantes/normas , Padrões de Referência , Soroalbumina Bovina/química , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA