Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 123
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Physiol Heart Circ Physiol ; 326(4): H877-H899, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38214900

RESUMO

Cardiovascular aging is strongly associated with increased risk of cardiovascular disease and mortality. Moreover, health and lifestyle factors may accelerate age-induced alterations, such as increased arterial stiffness and wall dilation, beyond chronological age, making the clinical assessment of cardiovascular aging an important prompt for preventative action. Carotid flow waveforms contain information about age-dependent cardiovascular properties, and their ease of measurement via noninvasive Doppler ultrasound (US) makes their analysis a promising tool for the routine assessment of cardiovascular aging. In this work, the impact of different aging processes on carotid waveform morphology and derived indexes is studied in silico, with the aim of establishing the clinical potential of a carotid US-based assessment of cardiovascular aging. One-dimensional (1-D) hemodynamic modeling was employed to generate an age-specific virtual population (VP) of N = 5,160 realistic carotid hemodynamic waveforms. The resulting VP was statistically validated against in vivo aging trends in waveforms and indexes from the literature, and simulated waveforms were studied in relation to age and underlying cardiovascular parameters. In our study, the carotid flow augmentation index (FAI) significantly increased with age (with a median increase of 50% from the youngest to the oldest age group) and was strongly correlated to local arterial stiffening (r = 0.94). The carotid pulsatility index (PI), which showed less pronounced age variation, was inversely correlated with the reflection coefficient at the carotid branching (r = -0.88) and directly correlated with carotid net forward wave energy (r = 0.90), corroborating previous literature where it was linked to increased risk of cerebrovascular damage in the elderly. There was a high correlation between corrected carotid flow time (ccFT) and cardiac output (CO) (r = 0.99), which was not affected by vascular age. This study highlights the potential of carotid waveforms as a valuable tool for the assessment of cardiovascular aging.NEW & NOTEWORTHY An age-specific virtual population was generated based on a 1-D model of the arterial circulation, including newly defined literature-based specific age variations in carotid vessel properties. Simulated carotid flow/velocity waveforms, indexes, and age trends were statistically validated against in vivo data from the literature. A comprehensive study of the impact of aging on carotid flow waveform morphology was performed, and the mechanisms influencing different carotid indexes were elucidated. Notably, flow augmentation index (FAI) was found to be a strong indicator of local carotid stiffness.


Assuntos
Envelhecimento , Doenças Cardiovasculares , Humanos , Idoso , Artérias Carótidas/diagnóstico por imagem , Hemodinâmica , Ultrassonografia
2.
Clin Chem Lab Med ; 62(6): 1118-1125, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38253354

RESUMO

OBJECTIVES: Urea and creatinine concentrations in plasma are used to guide hemodialysis (HD) in patients with end-stage renal disease (ESRD). To support individualized HD treatment in a home situation, there is a clinical need for a non-invasive and continuous alternative to plasma for biomarker monitoring during and between cycles of HD. In this observational study, we therefore established the correlation of urea and creatinine concentrations between sweat, saliva and plasma in a cohort of ESRD patients on HD. METHODS: Forty HD patients were recruited at the Dialysis Department of the Catharina Hospital Eindhoven. Sweat and salivary urea and creatinine concentrations were analyzed at the start and at the end of one HD cycle and compared to the corresponding plasma concentrations. RESULTS: A decrease of urea concentrations during HD was observed in sweat, from 27.86 mmol/L to 12.60 mmol/L, and saliva, from 24.70 mmol/L to 5.64 mmol/L. Urea concentrations in sweat and saliva strongly correlated with the concentrations in plasma (ρ 0.92 [p<0.001] and 0.94 [p<0.001], respectively). Creatinine concentrations also decreased in sweat from 43.39 µmol/L to 19.69 µmol/L, and saliva, from 59.00 µmol/L to 13.70 µmol/L. However, for creatinine, correlation coefficients were lower than for urea for both sweat and saliva compared to plasma (ρ: 0.58 [p<0.001] and 0.77 [p<0.001], respectively). CONCLUSIONS: The results illustrate a proof of principle of urea measurements in sweat and saliva to monitor HD adequacy in a non-invasive and continuous manner. Biosensors enabling urea monitoring in sweat or saliva could fill in a clinical need to enable at-home HD for more patients and thereby decrease patient burden.


Assuntos
Creatinina , Diálise Renal , Saliva , Suor , Ureia , Humanos , Ureia/análise , Ureia/sangue , Saliva/química , Creatinina/sangue , Creatinina/análise , Suor/química , Feminino , Masculino , Estudos de Coortes , Pessoa de Meia-Idade , Idoso , Falência Renal Crônica/terapia , Falência Renal Crônica/sangue , Adulto , Biomarcadores/análise , Biomarcadores/sangue
3.
J Clin Monit Comput ; 38(1): 147-156, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37864755

RESUMO

PURPOSE: This study aimed to describe the 24-hour cycle of wearable sensor-obtained heart rate in patients with deterioration-free recovery and to compare it with patients experiencing postoperative deterioration. METHODS: A prospective observational trial was performed in patients following bariatric or major abdominal cancer surgery. A wireless accelerometer patch (Healthdot) continuously measured postoperative heart rate, both in the hospital and after discharge, for a period of 14 days. The circadian pattern, or diurnal rhythm, in the wearable sensor-obtained heart rate was described using peak, nadir and peak-nadir excursions. RESULTS: The study population consisted of 137 bariatric and 100 major abdominal cancer surgery patients. In the latter group, 39 experienced postoperative deterioration. Both surgery types showed disrupted diurnal rhythm on the first postoperative days. Thereafter, the bariatric group had significantly lower peak heart rates (days 4, 7-12, 14), lower nadir heart rates (days 3-14) and larger peak-nadir excursions (days 2, 4-14). In cancer surgery patients, significantly higher nadir (days 2-5) and peak heart rates (days 2-3) were observed prior to deterioration. CONCLUSIONS: The postoperative diurnal rhythm of heart rate is disturbed by different types of surgery. Both groups showed recovery of diurnal rhythm but in patients following cancer surgery, both peak and nadir heart rates were higher than in the bariatric surgery group. Especially nadir heart rate was identified as a potential prognostic marker for deterioration after cancer surgery.


Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Humanos , Frequência Cardíaca/fisiologia , Ritmo Circadiano/fisiologia , Estudos Prospectivos
4.
BMC Anesthesiol ; 23(1): 308, 2023 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-37700233

RESUMO

BACKGROUND: There is still room for improvement of pain management after spinal surgery. The goal of this study was to evaluate adding the erector spinae block to the standard analgesia regimen. Our hypothesis was that the erector spinae plane block will decrease length of hospital stay, reduce opioid need and improve numeric rating scale pain scores. METHODS: This was a single center retrospective cohort study. We included 418 patients undergoing laminectomy or discectomy from January 2019 until December 2021. The erector spinae plane block was introduced in 2016 by Forero and colleagues and added to our clinical practice in October 2020. Patients who did not receive an erector spinae plane block prior to its implementation in October 2020 were used as control group. The primary outcome measure was functional recovery, measured by length of hospital stay. Secondary outcome measures were perioperative opioid consumption, need for patient-controlled analgesia and numeric rating scale pain scores. Postoperative data collection time points were: at the PACU and after 3, 6, 12 and 24 h postoperatively. RESULTS: There was a significant shorter length of hospital stay in patients undergoing single level laminectomy (with erector spinae plane block 29 h (IQR 27-51), without block 53 h (IQR 51-55), p < .001), multiple level laminectomy (with erector spinae plane block 49 h (IQR 31-54), without block 54 h (IQR 52-75), p < .001) and discectomy (with erector spinae plane block 27 h (IQR 25-30), without block 29 h (IQR 28-49), p = .04). CONCLUSIONS: Erector spinae plane block reduces length of stay after laminectomy surgery.


Assuntos
Laminectomia , Bloqueio Nervoso , Humanos , Analgésicos Opioides/uso terapêutico , Estudos Retrospectivos , Analgesia Controlada pelo Paciente , Discotomia , Dor
5.
Sensors (Basel) ; 23(9)2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-37177659

RESUMO

Assessing post-operative recovery is a significant component of perioperative care, since this assessment might facilitate detecting complications and determining an appropriate discharge date. However, recovery is difficult to assess and challenging to predict, as no universally accepted definition exists. Current solutions often contain a high level of subjectivity, measure recovery only at one moment in time, and only investigate recovery until the discharge moment. For these reasons, this research aims to create a model that predicts continuous recovery scores in perioperative care in the hospital and at home for objective decision making. This regression model utilized vital signs and activity metrics measured using wearable sensors and the XGBoost algorithm for training. The proposed model described continuous recovery profiles, obtained a high predictive performance, and provided outcomes that are interpretable due to the low number of features in the final model. Moreover, activity features, the circadian rhythm of the heart, and heart rate recovery showed the highest feature importance in the recovery model. Patients could be identified with fast and slow recovery trajectories by comparing patient-specific predicted profiles to the average fast- and slow-recovering populations. This identification may facilitate determining appropriate discharge dates, detecting complications, preventing readmission, and planning physical therapy. Hence, the model can provide an automatic and objective decision support tool.


Assuntos
Neoplasias , Dispositivos Eletrônicos Vestíveis , Humanos , Algoritmos , Assistência Perioperatória , Aprendizado de Máquina
6.
Br J Anaesth ; 129(4): 464-468, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36192052

RESUMO

Intraoperative hypotension is common and is associated with adverse postoperative outcomes. A substantial fraction of all perioperative hypotension occurs shortly after induction of anaesthesia and before the procedure begins. Arterial pressure monitoring is usually intermittent in this period, with a risk of missing significant hypotensive events. Continuous blood pressure monitoring might help reduce hypotension. There are now strong arguments that if an arterial line is indicated, it should be placed before induction of anaesthesia to obtain maximal benefit.


Assuntos
Pressão Arterial , Hipotensão , Determinação da Pressão Arterial/métodos , Febre/diagnóstico , Febre/etiologia , Humanos , Hipotensão/diagnóstico , Hipotensão/etiologia , Temperatura
7.
Br J Anaesth ; 128(4): 636-643, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35031105

RESUMO

BACKGROUND: Previous studies have shown that preoperative anaemia in patients undergoing cardiac surgery is associated with adverse outcomes. However, most of these studies were retrospective, had a relatively small sample size, and were from a single centre. The aim of this study was to analyse the relationship between the severity of preoperative anaemia and short- and long-term mortality and morbidity in a large multicentre national cohort of patients undergoing cardiac surgery. METHODS: A nationwide, prospective, multicentre registry (Netherlands Heart Registration) of patients undergoing elective cardiac surgery between January 2013 and January 2019 was used for this observational study. Anaemia was defined according to the WHO criteria, and the main study endpoint was 120-day mortality. The association was investigated using multivariable logistic regression analysis. RESULTS: In total, 35 484 patients were studied, of whom 6802 (19.2%) were anaemic. Preoperative anaemia was associated with an increased risk of 120-day mortality (adjusted odds ratio [aOR] 1.7; 95% confidence interval [CI]: 1.4-1.9; P<0.001). The risk of 120-day mortality increased with anaemia severity (mild anaemia aOR 1.6; 95% CI: 1.3-1.9; P<0.001; and moderate-to-severe anaemia aOR 1.8; 95% CI: 1.4-2.4; P<0.001). Preoperative anaemia was associated with red blood cell transfusion and postoperative morbidity, the causes of which included renal failure, pneumonia, and myocardial infarction. CONCLUSIONS: Preoperative anaemia was associated with mortality and morbidity after cardiac surgery. The risk of adverse outcomes increased with anaemia severity. Preoperative anaemia is a potential target for treatment to improve postoperative outcomes.


Assuntos
Anemia , Procedimentos Cirúrgicos Cardíacos , Anemia/complicações , Anemia/epidemiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos
8.
BMC Surg ; 22(1): 330, 2022 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-36058900

RESUMO

BACKGROUND: Adequate pain control after video-assisted thoracoscopic surgery (VATS) for lung resection is important to improve postoperative mobilisation, recovery, and to prevent pulmonary complications. So far, no consensus exists on optimal postoperative pain management after VATS anatomic lung resection. Thoracic epidural analgesia (TEA) is the reference standard for postoperative pain management following VATS. Although the analgesic effect of TEA is clear, it is associated with patient immobilisation, bladder dysfunction and hypotension which may result in delayed recovery and longer hospitalisation. These disadvantages of TEA initiated the development of unilateral regional techniques for pain management. The most frequently used techniques are continuous paravertebral block (PVB) and single-shot intercostal nerve block (ICNB). We hypothesize that using either PVB or ICNB is non-inferior to TEA regarding postoperative pain and superior regarding quality of recovery (QoR). Signifying faster postoperative mobilisation, reduced morbidity and shorter hospitalisation, these techniques may therefore reduce health care costs and improve patient satisfaction. METHODS: This multi-centre randomised study is a three-arm clinical trial comparing PVB, ICNB and TEA in a 1:1:1 ratio for pain (non-inferiority) and QoR (superiority) in 450 adult patients undergoing VATS anatomic lung resection. Patients will not be eligible for inclusion in case of contraindications for TEA, PVB or ICNB, chronic opioid use or if the lung surgeon estimates a high probability that the operation will be performed by thoracotomy. PRIMARY OUTCOMES: (1) the proportion of pain scores ≥ 4 as assessed by the numerical rating scale (NRS) measured during postoperative days (POD) 0-2; and (2) the QoR measured with the QoR-15 questionnaire on POD 1 and 2. Secondary outcome measures are cumulative use of opioids and analgesics, postoperative complications, hospitalisation, patient satisfaction and degree of mobility. DISCUSSION: The results of this trial will impact international guidelines with respect to perioperative care optimization after anatomic lung resection performed through VATS, and will determine the most cost-effective pain strategy and may reduce variability in postoperative pain management. Trial registration The trial is registered at the Netherlands Trial Register (NTR) on February 1st, 2021 (NL9243). The NTR is no longer available since June 24th, 2022 and therefore a revised protocol has been registered at ClinicalTrials.gov on August 5th, 2022 (NCT05491239). PROTOCOL VERSION: version 3 (date 06-05-2022), ethical approval through an amendment (see ethical proof in the Study protocol proof).


Assuntos
Analgesia Epidural , Cirurgia Torácica Vídeoassistida , Adulto , Analgesia Epidural/efeitos adversos , Humanos , Nervos Intercostais , Pulmão , Estudos Multicêntricos como Assunto , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Cirurgia Torácica Vídeoassistida/métodos
9.
J Clin Monit Comput ; 36(6): 1739-1752, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35142976

RESUMO

Large numbers of asynchronies during pressure support ventilation cause discomfort and higher work of breathing in the patient, and are associated with an increased mortality. There is a need for real-time decision support to detect asynchronies and assist the clinician towards lung-protective ventilation. Machine learning techniques have been proposed to detect asynchronies, but they require large datasets with sufficient data diversity, sample size, and quality for training purposes. In this work, we propose a method for generating a large, realistic and labeled, synthetic dataset for training and validating machine learning algorithms to detect a wide variety of asynchrony types. We take a model-based approach in which we adapt a non-linear lung-airway model for use in a diverse patient group and add a first-order ventilator model to generate labeled pressure, flow, and volume waveforms of pressure support ventilation. The model was able to reproduce basic measured lung mechanics parameters. Experienced clinicians were not able to differentiate between the simulated waveforms and clinical data (P = 0.44 by Fisher's exact test). The detection performance of the machine learning trained on clinical data gave an overall comparable true positive rate on clinical data and on simulated data (an overall true positive rate of 94.3% and positive predictive value of 93.5% on simulated data and a true positive rate of 98% and positive predictive value of 98% on clinical data). Our findings demonstrate that it is possible to generate labeled pressure and flow waveforms with different types of asynchronies.


Assuntos
Respiração com Pressão Positiva , Mecânica Respiratória , Humanos , Respiração com Pressão Positiva/métodos , Ventiladores Mecânicos , Respiração Artificial/métodos , Respiração
10.
Medicina (Kaunas) ; 58(9)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36143945

RESUMO

Background and Objectives: Clinical decision support systems are advocated to improve the quality and efficiency in healthcare. However, before implementation, validation of these systems needs to be performed. In this evaluation we tested our hypothesis that a computerized clinical decision support system can calculate the CHA2DS2-VASc score just as well compared to manual calculation, or even better and more efficiently than manual calculation in patients with atrial rhythm disturbances. Materials and Methods: In n = 224 patents, we calculated the total CHA2DS2-VASc score manually and by an automated clinical decision support system. We compared the automated clinical decision support system with manually calculation by physicians. Results: The interclass correlation between the automated clinical decision support system and manual calculation showed was 0.859 (0.611 and 0.931 95%-CI). Bland-Altman plot and linear regression analysis shows us a bias of -0.79 with limit of agreement (95%-CI) between 1.37 and -2.95 of the mean between our 2 measurements. The Cohen's kappa was 0.42. Retrospective analysis showed more human errors than algorithmic errors. Time it took to calculate the CHA2DS2-VASc score was 11 s per patient in the automated clinical decision support system compared to 48 s per patient with the physician. Conclusions: Our automated clinical decision support system is at least as good as manual calculation, may be more accurate and is more time efficient.


Assuntos
Fibrilação Atrial , Sistemas de Apoio a Decisões Clínicas , Acidente Vascular Cerebral , Técnicas de Apoio para a Decisão , Humanos , Valor Preditivo dos Testes , Melhoria de Qualidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/prevenção & controle
11.
Diabetes Obes Metab ; 22(4): 557-565, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31749275

RESUMO

AIMS: Most cardiac surgery patients, with or without diabetes, develop perioperative hyperglycaemia, for which intravenous insulin is the only therapeutic option. This is labour-intensive and carries a risk of hypoglycaemia. We hypothesized that preoperative administration of the glucagon-like peptide-1 receptor agonist liraglutide reduces the number of patients requiring insulin for glycaemic control during cardiac surgery. MATERIALS AND METHODS: In this randomized, blinded, placebo-controlled, parallel-group, balanced (1:1), multicentre randomized, superiority trial, adult patients undergoing cardiac surgery in four Dutch tertiary hospitals were randomized to receive 0.6 mg subcutaneous liraglutide on the evening before surgery and 1.2 mg after induction of anaesthesia or matching placebo. Blood glucose was measured hourly and controlled using an insulin-bolus algorithm. The primary outcome was insulin administration for blood glucose >8.0 mmol/L in the operating theatre. Research pharmacists used centralized, stratified, variable-block, randomization software. Patients, care providers and study personnel were blinded to treatment allocation. RESULTS: Between June 2017 and August 2018, 278 patients were randomized to liraglutide (139) or placebo (139). All patients receiving at least one study drug injection were included in the intention-to-treat analyses (129 in the liraglutide group, 132 in the placebo group). In the liraglutide group, 55 (43%) patients required additional insulin compared with 80 (61%) in the placebo group and absolute difference 18% (95% confidence interval 5.9-30.0, P = 0.003). Dose and number of insulin injections and mean blood glucose were all significantly lower in the liraglutide group. We observed no difference in the incidence of hypoglycaemia, nausea and vomiting, mortality or postoperative complications. CONCLUSIONS: Preoperative liraglutide, compared with placebo, reduces insulin requirements while improving perioperative glycaemic control during cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Diabetes Mellitus Tipo 2 , Hiperglicemia , Adulto , Glicemia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Método Duplo-Cego , Hemoglobinas Glicadas , Humanos , Hiperglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Liraglutida/uso terapêutico , Resultado do Tratamento
12.
Eur Heart J ; 39(28): 2646-2655, 2018 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-29617762

RESUMO

Aims: Echocardiography and tomographic imaging have documented dynamic changes in aortic stenosis (AS) geometry and severity during both the cardiac cycle and stress-induced increases in cardiac output. However, corresponding pressure gradient vs. flow relationships have not been described. Methods and results: We recruited 16 routine transcatheter aortic valve implantations (TAVI's) for graded dobutamine infusions both before and after implantation; 0.014″ pressure wires in the aorta and left ventricle (LV) continuously measured the transvalvular pressure gradient (ΔP) while a pulmonary artery catheter regularly assessed cardiac output by thermodilution. Before TAVI, ΔP did not display a consistent relationship with transvalvular flow (Q). Neither linear resistor (median R2 0.16) nor quadratic orifice (median R2 < 0.01) models at rest predicted stress observations; the severely stenotic valve behaved like a combination. The unitless ratio of aortic to left ventricular pressures during systolic ejection under stress conditions correlated best with post-TAVI flow improvement. After TAVI, a highly linear relationship (median R2 0.96) indicated a valid valve resistance. Conclusion: Pressure loss vs. flow curves offer a fundamental fluid dynamic synthesis for describing aortic valve pathophysiology. Severe AS does not consistently behave like an orifice (as suggested by Gorlin) or a resistor, whereas TAVI devices behave like a pure resistor. During peak dobutamine, the ratio of aortic to left ventricular pressures during systolic ejection provides a 'fractional flow reserve' of the aortic valve that closely approximates the complex, changing fluid dynamics. Because resting assessment cannot reliably predict stress haemodynamics, 'valvular fractional flow' warrants study to explain exertional symptoms in patients with only moderate AS at rest.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/fisiologia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Humanos , Masculino , Fluxo Sanguíneo Regional , Índice de Gravidade de Doença , Fatores de Tempo
13.
J Clin Monit Comput ; 33(6): 1023-1031, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30661195

RESUMO

Accumulating evidence shows that ultrasound (US) guidance improves effectiveness and safety of central venous catheter (CVC) placement. Several international guidelines therefore recommend the use of US for placement of CVCs. However, surveys show that the landmark-based technique is still widely used, while the percentage of physicians using US is increasing less than expected. The goal of this study was to investigate current practice for central venous catheterization in anaesthesiology and intensive care in the Netherlands, identify barriers for further implementation of US guidance and to evaluate whether personality traits are associated with the choice of technique. We conducted a web-based national survey, distributed among members of the Dutch societies of anaesthesiology (NVA) and intensive care (NVIC). The survey contained questions regarding physician and hospital characteristics, frequency of US use and reasons for use or non-use, as well as the NEO-FFI-3, a validated, translated questionnaire to characterize personality traits according to the 'Big Five' concept. Response rate was 22% (506/2291), of which 400 had also the personality questionnaire complete. Ultrasound guidance was used always or almost always in 68%; barriers for US use were working in a non-academic non-teaching hospital, providing cardiac anaesthesia and more years of physician experience. Reasons for not using US were perceived lack of benefit, increased procedure time, lack of US equipment and fear of loss of landmark technique skills. 13% of respondents had never experienced a complication during CVC placement, and 67% knew of a complication occurring the past year at their department. Ultrasound was thought not to be able to prevent the complication in half of these cases. Of the personality traits, only neuroticism and extraversion showed a minor positive association with US guidance. A majority of anaesthesiologists and intensivists uses US guidance for CVC placement, but a significant proportion of physicians still prefers the landmark technique. Most arguments from respondents against US guidance can be challenged. Personality traits most likely do not play a major role in the acceptance of US guidance for central venous catheterization. A potential intervention to increase US use could be formalizing local hospital policies mandating compliance with US guidance. Future research can perhaps focus on cognitive biases that currently limit more widespread use of US guidance.


Assuntos
Anestesiologia/normas , Cateterismo Venoso Central/tendências , Cuidados Críticos/normas , Personalidade , Padrões de Prática Médica , Ultrassonografia de Intervenção/tendências , Anestesiologistas , Anestesiologia/tendências , Cateterismo Venoso Central/normas , Cateteres Venosos Centrais , Cognição , Cuidados Críticos/tendências , Feminino , Humanos , Internacionalidade , Internet , Masculino , Países Baixos , Guias de Prática Clínica como Assunto , Análise de Regressão , Resultado do Tratamento , Ultrassonografia de Intervenção/normas
15.
J Cardiothorac Vasc Anesth ; 32(1): 259-266, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29229263

RESUMO

OBJECTIVES: Patients with decreased left ventricular function undergoing cardiac surgery have a greater chance of difficult weaning from cardiopulmonary bypass and a poorer clinical outcome. Directly after weaning, interventricular dyssynchrony, paradoxical septal motion, and even temporary bundle-branch block might be observed. In this study, the authors measured arterial dP/dtmax, mean arterial pressure (MAP), and cardiac index using transpulmonary thermodilution, pulse contour analysis, and femoral artery catheter and compared the effects between right ventricular (A-RV) and biventricular (A-BiV) pacing on these parameters. DESIGN: Prospective study. SETTING: Single-center study. PARTICIPANTS: The study comprised 17 patients with a normal or prolonged QRS duration and a left ventricular ejection fraction ≤35% who underwent coronary artery bypass grafting with or without valve replacement. INTERVENTIONS: Temporary pacing wires were placed on the right atrium and both ventricles. Different pacing modalities were used in a standardized order. MEASUREMENTS AND MAIN RESULTS: A-BiV pacing compared with A-RV pacing demonstrated higher arterial dP/dtmax values (846 ± 646 mmHg/s v 800 ± 587 mmHg/s, p = 0.023) and higher MAP values (77 ± 19 mmHg v 71 ± 18 mmHg, p = 0.036). CONCLUSION: In patients with preoperative decreased left ventricular function undergoing coronary artery bypass grafting, A-BiV pacing improve the arterial dP/dtmax and MAP in patients with both normal and prolonged QRS duration compared with standard A-RV pacing. In addition, arterial dP/dtmax and MAP can be used to evaluate the effect of intraoperative pacing. In contrast to previous studies using more invasive techniques, transpulmonary thermodilution is easy to apply in the perioperative clinical setting.


Assuntos
Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Ponte Cardiopulmonar/métodos , Hemodinâmica/fisiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/tendências , Terapia de Ressincronização Cardíaca/tendências , Ponte Cardiopulmonar/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Função Ventricular Esquerda/fisiologia
17.
Br J Anaesth ; 119(2): 231-238, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28854530

RESUMO

BACKGROUND: Checklists can reduce medical errors. However, the effectiveness of checklists is hampered by lack of acceptance and compliance. Recently, a new type of checklist with dynamic properties has been created to provide more specific checklist items for each individual patient. Our purpose in this simulation-based study was to investigate a newly developed intelligent dynamic clinical checklist (DCC) for the intensive care unit (ICU) ward round. METHODS: Eligible clinicians were invited to participate as volunteers. Highest achievable scores were established for six typical ICU scenarios to determine which items must be checked. The participants compared the DCC with the local standard of care. The primary outcomes were the caregiver satisfaction score and the percentages of checked items overall and of critical items requiring a direct intervention. RESULTS: In total, 20 participants were included, who performed 116 scenarios. The median percentage of checked items was 100.0% with the DCC and 73.6% for the scenarios completed with local standard of care ( P <0.001). Critical items remained unchecked in 23.1% of the scenarios performed with local standard of care and 0.0% of the scenarios where the DCC was available ( P <0.001). The mean satisfaction score of the DCC was 4.13 out of 5. CONCLUSIONS: This simulation study indicates that an intelligent DCC significantly increases compliance with best practice by reducing the percentage of unchecked items during ICU ward rounds, while the user satisfaction rate remains high. Real-life clinical research is required to evaluate this new type of checklist further.


Assuntos
Lista de Checagem , Unidades de Terapia Intensiva , Adulto , Idoso , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação Pessoal , Estudos Prospectivos
18.
Br J Anaesth ; 119(2): 258-266, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28854536

RESUMO

BACKGROUND: The incidence and impact of postoperative complications are poorly described. Failure-to-rescue, the rate of death following complications, is an important quality measure for perioperative care but has not been investigated across multiple health care systems. METHODS: We analysed data collected during the International Surgical Outcomes Study, an international 7-day cohort study of adults undergoing elective inpatient surgery. Hospitals were ranked by quintiles according to surgical procedural volume (Q1 lowest to Q5 highest). For each quintile we assessed in-hospital complications rates, mortality, and failure-to-rescue. We repeated this analysis ranking hospitals by risk-adjusted complication rates (Q1 lowest to Q5 highest). RESULTS: A total of 44 814 patients from 474 hospitals in 27 low-, middle-, and high-income countries were available for analysis. Of these, 7508 (17%) developed one or more postoperative complication, with 207 deaths in hospital (0.5%), giving an overall failure-to-rescue rate of 2.8%. When hospitals were ranked in quintiles by procedural volume, we identified a three-fold variation in mortality (Q1: 0.6% vs Q5: 0.2%) and a two-fold variation in failure-to-rescue (Q1: 3.6% vs Q5: 1.7%). Ranking hospitals in quintiles by risk-adjusted complication rate further confirmed the presence of important variations in failure-to-rescue, indicating differences between hospitals in the risk of death among patients after they develop complications. CONCLUSIONS: Comparison of failure-to-rescue rates across health care systems suggests the presence of preventable postoperative deaths. Using such metrics, developing nations could benefit from a data-driven approach to quality improvement, which has proved effective in high-income countries.


Assuntos
Cuidados Pós-Operatórios/normas , Complicações Pós-Operatórias/mortalidade , Qualidade da Assistência à Saúde , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos
19.
Anaesthesia ; 72(7): 889-904, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28542716

RESUMO

Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety.


Assuntos
Agulhas , Bloqueio Nervoso/métodos , Ultrassonografia de Intervenção/métodos , Fenômenos Eletromagnéticos , Humanos , Bloqueio Nervoso/instrumentação
20.
Echocardiography ; 34(8): 1138-1145, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28600804

RESUMO

INTRODUCTION: Pulmonary transit time (PTT) assessed with contrast-enhanced ultrasound (CEUS) is a novel tool to evaluate cardiac function. PTT represents the time for a bolus of contrast to pass from the right to the left ventricle, measured according to the indicator dilution principles using CEUS. We investigated the hypothesis that PTT is a measure of general cardiac performance in patient populations eligible for cardiac resynchronization therapy (CRT). METHODS: The study population consisted of heart failure patients referred for CRT with NYHA class II-IV, left ventricular ejection fraction (LVEF)≤35% and QRS≥120 ms. CEUS, ECG, and blood were analyzed, and participants completed a quality of life questionnaire at baseline and 3 months after CRT implantation. Normalized PTT (nPTT) was calculated to compensate for the heart rate. Correlations were assessed with Pearson's or Spearman's coefficients and stratified for rhythm and NYHA class. RESULTS: The study population consisted of 94 patients (67 men) with a mean age of 70±8.9 years. (n)PTT was significantly correlated with left ventricular parameters (rs =-.487, P<.001), right ventricular parameters (r=-.282, P=.004), N-terminal pro-B-type natriuretic peptide (NT-proBNP) (rs =.475, P<.001), and quality of life (rs =.364, P<.001). Stronger significant correlations were found in patients in sinus rhythm. CONCLUSION: CEUS-derived PTT and nPTT correlate to a fair degree with measures of systolic and diastolic function, NT-pro-BNP, and quality of life. As CEUS-derived PTT can be obtained easily, noninvasively and at the bedside, it is a promising future measure of general cardiac performance.


Assuntos
Volume Sanguíneo/fisiologia , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Determinação do Volume Sanguíneo , Meios de Contraste/farmacologia , Diástole , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sístole
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA