Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Respir J ; 61(2)2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36229048

RESUMO

BACKGROUND: Granulocyte-macrophage colony-stimulating factor (GM-CSF) and dysregulated myeloid cell responses are implicated in the pathophysiology and severity of COVID-19. METHODS: In this randomised, sequential, multicentre, placebo-controlled, double-blind study, adults aged 18-79 years (Part 1) or ≥70 years (Part 2) with severe COVID-19, respiratory failure and systemic inflammation (elevated C-reactive protein/ferritin) received a single intravenous infusion of otilimab 90 mg (human anti-GM-CSF monoclonal antibody) plus standard care (NCT04376684). The primary outcome was the proportion of patients alive and free of respiratory failure at Day 28. RESULTS: In Part 1 (n=806 randomised 1:1 otilimab:placebo), 71% of otilimab-treated patients were alive and free of respiratory failure at Day 28 versus 67% who received placebo; the model-adjusted difference of 5.3% was not statistically significant (95% CI -0.8-11.4%, p=0.09). A nominally significant model-adjusted difference of 19.1% (95% CI 5.2-33.1%, p=0.009) was observed in the predefined 70-79 years subgroup, but this was not confirmed in Part 2 (n=350 randomised) where the model-adjusted difference was 0.9% (95% CI -9.3-11.2%, p=0.86). Compared with placebo, otilimab resulted in lower serum concentrations of key inflammatory markers, including the putative pharmacodynamic biomarker CC chemokine ligand 17, indicative of GM-CSF pathway blockade. Adverse events were comparable between groups and consistent with severe COVID-19. CONCLUSIONS: There was no significant difference in the proportion of patients alive and free of respiratory failure at Day 28. However, despite the lack of clinical benefit, a reduction in inflammatory markers was observed with otilimab, in addition to an acceptable safety profile.


Assuntos
COVID-19 , Insuficiência Respiratória , Adulto , Humanos , Fator Estimulador de Colônias de Granulócitos e Macrófagos , Anticorpos Monoclonais Humanizados , Método Duplo-Cego , Resultado do Tratamento
2.
Pulm Pharmacol Ther ; 79: 102201, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36841351

RESUMO

Activated PI3Kδ Syndrome (APDS) is a rare inherited inborn error of immunity caused by mutations that constitutively activate the p110 delta isoform of phosphoinositide 3-kinase (PI3Kδ), resulting in recurring pulmonary infections. Currently no licensed therapies are available. Here we report the results of an open-label trial in which five subjects were treated for 12 weeks with nemiralisib, an inhaled inhibitor of PI3Kδ, to determine safety, systemic exposure, together with lung and systemic biomarker profiles (Clinicaltrial.gov: NCT02593539). Induced sputum was captured to measure changes in phospholipids and inflammatory mediators, and blood samples were collected to assess pharmacokinetics of nemiralisib, and systemic biomarkers. Nemiralisib was shown to have an acceptable safety and tolerability profile, with cough being the most common adverse event, and no severe adverse events reported during the study. No meaningful changes in phosphatidylinositol (3,4,5)-trisphosphate (PIP3; the enzyme product of PI3Kδ) or downstream inflammatory markers in induced sputum, were observed following nemiralisib treatment. Similarly, there were no meaningful changes in blood inflammatory markers, or lymphocytes subsets. Systemic levels of nemiralisib were higher in subjects in this study compared to previous observations. While nemiralisib had an acceptable safety profile, there was no convincing evidence of target engagement in the lung following inhaled dosing and no downstream effects observed in either the lung or blood compartments. We speculate that this could be explained by nemiralisib not being retained in the lung for sufficient duration, suggested by the increased systemic exposure, perhaps due to pre-existing structural lung damage. In this study investigating a small number of subjects with APDS, nemiralisib appeared to be safe and well-tolerated. However, data from this study do not support the hypothesis that inhaled treatment with nemiralisib would benefit patients with APDS.


Assuntos
Antineoplásicos , Fosfatidilinositol 3-Quinases , Humanos , Administração por Inalação , Inibidores de Proteínas Quinases , Fosfatidilinositol 3-Quinase
3.
Br J Clin Pharmacol ; 89(12): 3669-3680, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37522415

RESUMO

AIMS: To examine the role of ex vivo oxytocin metabolism in post-dose peptide measurements. METHODS: The stability of oxytocin (Study 1) and oxytocinase activity (Study 2) in late-stage pregnancy blood was quantified using liquid-chromatography tandem mass-spectrometry (LC-MS/MS) and a fluorogenic assay, respectively. Analyses were conducted using blood from pregnant women (>36 weeks gestation) evaluated in lithium heparin (LH), ethylenediaminetetraacetic acid (EDTA) and BD P100 blood collection tubes with or without protease inhibitors. In addition, plasma oxytocin concentrations following administration of oxytocin 240 IU inhaled, 5 IU intravenous or 10 IU intramuscular in women in third stage of labour (TSL) were analysed using enzyme-linked immunosorbent assay (ELISA) and LC-MS/MS to understand how quantified peptide concentrations differ between these analytical methods (Study 3). RESULTS: Study 1: Oxytocin was stable in blood collected into EDTA tubes with or without protease inhibitors but not in LH tubes. Study 2: Blood collected into all EDTA-containing collection tubes led to near-complete inhibition of oxytocinase (≤100 min). In plasma, a 35% reduction in oxytocinase activity was observed in LH tubes with EDTA added. In plasma from late-stage pregnancy compared to nonpregnant participants, the oxytocinase activity was approximately 11-fold higher. Study 3: Plasma oxytocin concentrations from nonpregnant or women in TSL following exogenous oxytocin administration were ≤33 times higher when analysed using ELISA vs. LC-MS/MS methods. CONCLUSIONS: Collection of blood from late-stage pregnant women into tubes containing EDTA inhibits oxytocinase effectively stabilizing oxytocin, suggesting low concentrations of oxytocin after dose administration reflect rapid in vivo metabolism.


Assuntos
Cistinil Aminopeptidase , Ocitocina , Gravidez , Feminino , Humanos , Ocitocina/farmacologia , Ácido Edético , Cromatografia Líquida , Espectrometria de Massas em Tandem , Heparina , Inibidores de Proteases
4.
Br J Clin Pharmacol ; 89(12): 3681-3689, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37485589

RESUMO

AIMS: To compare pharmacokinetics (PK) and safety of heat-stable inhaled (IH) oxytocin with intramuscular (IM) oxytocin in women in third stage of labour (TSL), the primary endpoint being PK profiles of oxytocin IH and secondary endpoint of safety. METHODS: A phase 1, randomized, cross-over study was undertaken in 2 UK and 1 Australian centres. Subjects were recruited into 2 groups: Group 1, women in TSL; Group 2, nonpregnant women of childbearing potential (Cohort A, combined oral contraception; Cohort B, nonhormonal contraception). Participants were randomized 1:1 to: Group 1, oxytocin 10 IU (17 µg) IM or oxytocin 240 IU (400 µg) IH immediately after delivery; Group 2, oxytocin 5 IU (8.5 µg) intravenously and oxytocin 240 IU (400 µg) IH at 2 separate dosing sessions. RESULTS: Participants were recruited between 23 November 2016 to 4 March 2019. In Group 1, 17 participants were randomized; received either IH (n = 9) or IM (n = 8) oxytocin. After IH and IM administration, most plasma oxytocin concentrations were below quantification limits (2 pg/mL). In Group 2 (n = 14), oxytocin IH concentrations remained quantifiable ≤3 h postdose. Adverse events were reported in both groups, with no deaths reported: Group 1, IH n = 3 (33%) and IM n = 2 (25%); Group 2, n = 14 (100%). CONCLUSION: Safety profiles of oxytocin IH and IM were similar. However, PK profiles could not be established for oxytocin IH or IM in women in TSL, despite using a highly sensitive and specific assay.


Assuntos
Ocitócicos , Hemorragia Pós-Parto , Feminino , Humanos , Austrália , Estudos Cross-Over , Ocitócicos/efeitos adversos , Ocitocina/efeitos adversos , Hemorragia Pós-Parto/induzido quimicamente
5.
Respir Res ; 23(1): 118, 2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35546672

RESUMO

BACKGROUND: Currently the only available therapies for fibrotic Interstitial Lung Disease are administered systemically, often causing significant side effects. Inhaled therapy could avoid these but to date there is no evidence that drug can be effectively delivered to distal, fibrosed lung. We set out to combine mass spectrometry and histopathology with rapid sample acquisition using transbronchial cryobiopsy to determine whether an inhaled drug can be delivered to fibrotic, distal lung parenchyma in participants with Interstitial Lung Disease. METHODS: Patients with radiologically and multidisciplinary team confirmed fibrotic Interstitial Lung Disease were eligible for this study. Transbronchial cryobiopsies and endobronchial biopsies were taken from five participants, with Interstitial Lung Disease, within 70 min of administration of a single dose of nebulised ipratropium bromide. Thin tissue cryosections were analysed by Matrix Assisted Laser Desorption/Ionization-Mass Spectrometry imaging and correlated with histopathology. The remainder of the cryobiopsies were homogenised and analysed by Liquid Chromatography-tandem Mass Spectrometry. RESULTS: Drug was detected in proximal and distal lung samples from all participants. Fibrotic regions were identified in research samples of four of the five participants. Matrix Assisted Laser Desorption/Ionization-Mass Spectrometry imaging showed co-location of ipratropium with fibrotic regions in samples from three participants. CONCLUSIONS: In this proof of concept study, using mass spectrometry, we demonstrate for the first-time that an inhaled drug can deposit in distal fibrotic lung parenchyma in patients with Interstitial Lung Disease. This suggests that drugs to treat pulmonary fibrosis could potentially be administered by the inhaled route. Trial registration A prospective clinical study approved by London Camden and Kings Cross Research Ethics Committee and registered on clinicaltrials.gov (NCT03136120).


Assuntos
Doenças Pulmonares Intersticiais , Fibrose Pulmonar , Humanos , Pulmão/patologia , Doenças Pulmonares Intersticiais/diagnóstico , Espectrometria de Massas , Estudos Prospectivos , Fibrose Pulmonar/diagnóstico por imagem , Fibrose Pulmonar/tratamento farmacológico , Fibrose Pulmonar/patologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
6.
Br J Clin Pharmacol ; 88(2): 702-712, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34292606

RESUMO

AIMS: GSK3511294 is a humanized anti-interleukin (IL)-5 monoclonal antibody (mAb) engineered for extended half-life and improved IL-5 affinity versus other anti-IL-5 mAbs. This study examined its safety, tolerability, pharmacokinetics (PK) and effect on blood eosinophil counts. METHODS: This was a double-blind, parallel-group, single-ascending-dose, multicenter, Phase 1 study (205 722;NCT03287310) in patients with asthma and a blood eosinophil count ≥200 cells µL-1 . Patients were randomized 3:1 within dose cohorts to receive a single subcutaneous dose of GSK3511294 (2, 10, 30, 100 or 300 mg) or placebo and followed for up to 40 weeks to assess safety (primary endpoint), ratio to baseline in blood eosinophil count, plasma PK parameters and frequency/titers of binding antidrug antibodies (all secondary). RESULTS: Forty-eight patients received the study drug and completed the study. Adverse events (AEs) occurred in 92% of placebo-treated and 81% of GSK3511294-treated patients. There were no AEs leading to study withdrawal or serious AEs; hypersensitivity (one event in one patient) and injection-site reaction (three events in two patients) occurred infrequently. Marked reductions (>48%) in blood eosinophil count were seen from 24 hours post-dose with all GSK3511294 doses but not placebo; suppression was maintained for longer with increasing dose (82% and 83% adjusted reductions vs placebo with 100 and 300 mg, respectively, at week 26). PK were linear and dose proportional over the dose range; terminal half-life was 38-53 days. CONCLUSIONS: GSK3511294 was well tolerated, with linear and dose proportional PK, extended half-life and blood eosinophil count reduction, supporting less frequent dosing versus other anti-IL-5 mAbs.


Assuntos
Asma , Interleucina-5 , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais Humanizados/uso terapêutico , Asma/complicações , Asma/terapia , Método Duplo-Cego , Eosinófilos/metabolismo , Humanos , Interleucina-5/antagonistas & inibidores , Interleucina-5/metabolismo , Interleucina-5/uso terapêutico
7.
Thorax ; 76(10): 1032-1035, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33632769

RESUMO

End points that are repeatable and sensitive to change are important in pulmonary arterial hypertension (PAH) for clinical practice and trials of new therapies. In 42 patients with PAH, test-retest repeatability was assessed using the intraclass correlation coefficient and treatment effect size using Cohen's d statistic. Intraclass correlation coefficients demonstrated excellent repeatability for MRI, 6 min walk test and log to base 10 N-terminal pro-brain natriuretic peptide (log10NT-proBNP). The treatment effect size for MRI-derived right ventricular ejection fraction was large (Cohen's d 0.81), whereas the effect size for the 6 min walk test (Cohen's d 0.22) and log10NT-proBNP (Cohen's d 0.20) were fair. This study supports further evaluation of MRI as a non-invasive end point for clinical assessment and PAH therapy trials.Trial registration number NCT03841344.


Assuntos
Hipertensão Pulmonar , Hipertensão Arterial Pulmonar , Humanos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Volume Sistólico , Função Ventricular Direita , Teste de Caminhada
8.
Drug Metab Dispos ; 48(4): 307-316, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32009006

RESUMO

In vitro data for low-dose inhaled phosphoinositide 3-kinase delta inhibitor nemiralisib revealed that it was a substrate and a potent metabolism-dependent inhibitor of cytochrome P450 (P450) 3A4 and a P-glycoprotein (P-gp) substrate. An integrated in silico, in vitro, and clinical approach including a clinical drug interaction study as well as a bespoke physiologically based pharmacokinetic (PBPK) model was used to assess the drug-drug interaction (DDI) risk. Inhaled nemiralisib (100 µg, single dose) was coadministered with itraconazole, a potent P4503A4/P-gp inhibitor, following 200 mg daily administrations for 10 days in 20 male healthy subjects. Systemic exposure to nemiralisib (AUC0-inf) increased by 2.01-fold versus nemiralisib alone. To extrapolate the clinical data to other P4503A4 inhibitors, an inhaled PBPK model was developed using Simcyp software. Retrospective simulation of the victim risk showed good agreement between simulated and observed data (AUC0-inf ratio 2.3 vs. 2.01, respectively). Prospective DDI simulations predicted a weak but manageable drug interaction when nemiralisib was coadministered with other P4503A4 inhibitors, such as the macrolides clarithromycin and erythromycin (simulated AUC0-inf ratio of 1.7), both common comedications in the intended patient populations. PBPK and static mechanistic models were also used to predict a negligible perpetrator DDI effect for nemiralisib on other P4503A4 substrates, including midazolam (a sensitive probe substrate of P4503A4) and theophylline (a narrow therapeutic index drug and another common comedication). In summary, an integrated in silico, in vitro, and clinical approach including an inhalation PBPK model has successfully discharged any potential patient DDI risks in future nemiralisib clinical trials. SIGNIFICANCE STATEMENT: This paper describes the integration of in silico, in vitro, and clinical data to successfully discharge potential drug-drug interaction risks for a low-dose inhaled drug. This work featured assessment of victim and perpetrator risks of drug transporters and cytochrome P450 enzymes, utilizing empirical and mechanistic approaches combined with clinical data (drug interaction and human absorption, metabolism, and pharmacokinetics) and physiologically based pharmacokinetic modeling approaches to facilitate bespoke risk assessment in target patient populations.


Assuntos
Inibidores do Citocromo P-450 CYP3A/farmacocinética , Citocromo P-450 CYP3A/metabolismo , Indazóis/farmacocinética , Indóis/farmacocinética , Itraconazol/farmacocinética , Oxazóis/farmacocinética , Inibidores de Fosfoinositídeo-3 Quinase/farmacocinética , Piperazinas/farmacocinética , Administração por Inalação , Adolescente , Adulto , Idoso , Área Sob a Curva , Claritromicina/administração & dosagem , Claritromicina/farmacocinética , Simulação por Computador , Estudos Cross-Over , Inibidores do Citocromo P-450 CYP3A/administração & dosagem , Interações Medicamentosas , Eritromicina/administração & dosagem , Eritromicina/farmacocinética , Voluntários Saudáveis , Humanos , Indazóis/administração & dosagem , Indóis/administração & dosagem , Itraconazol/administração & dosagem , Masculino , Microssomos Hepáticos , Midazolam/administração & dosagem , Midazolam/farmacocinética , Pessoa de Meia-Idade , Modelos Biológicos , Oxazóis/administração & dosagem , Inibidores de Fosfoinositídeo-3 Quinase/administração & dosagem , Piperazinas/administração & dosagem , Estudos Prospectivos , Estudos Retrospectivos , Adulto Jovem
9.
Thorax ; 74(7): 659-666, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30674586

RESUMO

RATIONALE: There is a need to develop imaging protocols which assess neutrophilic inflammation in the lung. AIM: To quantify whole lung neutrophil accumulation in (1) healthy volunteers (HV) following inhaled lipopolysaccharide (LPS) or saline and (2) patients with COPD using radiolabelled autologous neutrophils and single-photon emission computed tomography/CT (SPECT/CT). METHODS: 20 patients with COPD (Global initiative for chronic obstructive lung disease (GOLD) stages 2-3) and 18 HVs were studied. HVs received inhaled saline (n=6) or LPS (50 µg, n=12) prior to the injection of radiolabelled cells. Neutrophils were isolated using dextran sedimentation and Percoll plasma gradients and labelled with 99mTechnetium (Tc)-hexamethylpropyleneamine oxime. SPECT was performed over the thorax/upper abdomen at 45 min, 2 hours, 4 hours and 6 hours. Circulating biomarkers were measured prechallenge and post challenge. Blood neutrophil clearance in the lung was determined using Patlak-Rutland graphical analysis. RESULTS: There was increased accumulation of 99mTc-neutrophils in the lungs of patients with COPD and LPS-challenged subjects compared with saline-challenged subjects (saline: 0.0006±0.0003 mL/min/mL lung blood distribution volume [mean ±1 SD]; COPD: 0.0022±0.0010 mL/min/mL [p<0.001]; LPS: 0.0025±0.0008 mL/min/mL [p<0.001]). The accumulation of labelled neutrophils in 10 patients with COPD who underwent repeat radiolabelling/imaging 7-10 days later was highly reproducible (0.0022±0.0010 mL/min/mL vs 0.0023±0.0009 mL/min/mL). Baseline interleukin (IL)-6 levels in patients with COPD were elevated compared with HVs (1.5±1.06 pg/mL [mean ±1 SD] vs 0.4±0.24 pg/mL). LPS challenge increased the circulating IL-6 levels (7.5±2.72 pg/mL) 9 hours post challenge. CONCLUSIONS: This study shows the ability to quantify 'whole lung' neutrophil accumulation in HVs following LPS inhalation and in subjects with COPD using autologous radiolabelled neutrophils and SPECT/CT imaging. Moreover, the reproducibility observed supports the feasibility of using this approach to determine the efficacy of therapeutic agents aimed at altering neutrophil migration to the lungs.


Assuntos
Pulmão/diagnóstico por imagem , Neutrófilos/fisiologia , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Idoso , Biomarcadores/sangue , Feminino , Humanos , Interleucina-6/sangue , Lipopolissacarídeos , Masculino , Pessoa de Meia-Idade , Infiltração de Neutrófilos/efeitos dos fármacos , Infiltração de Neutrófilos/fisiologia , Doença Pulmonar Obstrutiva Crônica/patologia , Reprodutibilidade dos Testes , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio
10.
J Pharmacol Exp Ther ; 369(3): 443-453, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30940692

RESUMO

This study describes the pharmacokinetic (PK) and pharmaco-dynamic (PD) profile of N-(5-(4-(5-(((2R,6S)-2,6-dimethylmorpholino)methyl)oxazol-2-yl)-1H-indazol-6-yl)-2-methoxypyridin-3-yl)methanesulfonamide (GSK2292767A), a novel low-solubility inhaled phosphoinositide 3-kinase delta (PI3Kδ) inhibitor developed as an alternative to 2-(6-(1H-indol-4-yl)-1H-indazol-4-yl)-5-((4-isopropylpiperazin-1-yl)methyl)oxazole (nemiralisib), which is a highly soluble inhaled inhibitor of PI3Kδ with a lung profile consistent with once-daily dosing. GSK2292767A has a similar in vitro cellular profile to nemiralisib and reduces eosinophilia in a murine PD model by 63% (n = 5, P < 0.05). To explore whether a low-soluble compound results in effective PI3Kδ inhibition in humans, a first time in human study was conducted with GSK2292767A in healthy volunteers who smoke. GSK2292767A was generally well tolerated, with headache being the most common reported adverse event. PD changes in induced sputum were measured in combination with drug concentrations in plasma from single (0.05-2 mg, n = 37), and 14-day repeat (2 mg, n = 12) doses of GSK2292767A. Trough bronchoalveolar lavage (BAL) for PK was taken after 14 days of repeat dosing. GSK2292767A displayed a linear increase in plasma exposure with dose, with marginal accumulation after 14 days. Induced sputum showed a 27% (90% confidence interval 15%, 37%) reduction in phosphatidylinositol-trisphosphate (the product of phosphoinositide 3-kinase activation) 3 hours after a single dose. Reduction was not maintained 24 hours after single or repeat dosing. BAL analysis confirmed the presence of GSK2292767A in lung at 24 hours, consistent with the preclinical lung retention profile. Despite good lung retention, target engagement was only present at 3 hours. This exposure-response disconnect is an important observation for future inhaled drug design strategies considering low solubility to drive lung retention.


Assuntos
Indazóis/farmacologia , Indazóis/farmacocinética , Inibidores de Fosfoinositídeo-3 Quinase/farmacologia , Inibidores de Fosfoinositídeo-3 Quinase/farmacocinética , Sulfonamidas/farmacologia , Sulfonamidas/farmacocinética , Pesquisa Translacional Biomédica , Administração por Inalação , Adulto , Animais , Lavagem Broncoalveolar , Eosinofilia/tratamento farmacológico , Feminino , Humanos , Indazóis/administração & dosagem , Indazóis/efeitos adversos , Pulmão/metabolismo , Masculino , Camundongos , Pessoa de Meia-Idade , Permeabilidade , Inibidores de Fosfoinositídeo-3 Quinase/administração & dosagem , Inibidores de Fosfoinositídeo-3 Quinase/efeitos adversos , Segurança , Solubilidade , Escarro/efeitos dos fármacos , Escarro/metabolismo , Sulfonamidas/administração & dosagem , Sulfonamidas/efeitos adversos
11.
J Pharmacol Exp Ther ; 367(3): 405-413, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30217958

RESUMO

Phosphoinositide 3-kinase δ (PI3Kδ) is a lipid kinase involved in leukocyte recruitment and activation. Activation of PI3Kδ has been linked to airway inflammation and asthma pathogenesis. This randomized, double-blind, placebo-controlled, crossover study investigated the efficacy, safety, tolerability, and pharmacokinetics of a PI3Kδ inhibitor, nemiralisib (GSK2269557), in patients with persistent, uncontrolled asthma. Patients (n = 50) received once-daily inhaled nemiralisib (1000 µg) or placebo for 28 days, with a crossover to the alternative treatment following a 4-week washout period. Spirometry demonstrated no discernible difference in trough forced expiratory volume in 1 second (FEV1) from baseline (adjusted posterior median 7 ml; 95% credible interval -83, 102 ml) between nemiralisib and placebo treatment at day 28 (primary endpoint). These results were supported by most secondary endpoints, including weighted mean FEV1 (0-4 hours) and change in trough forced vital capacity at day 28. Nemiralisib was generally well-tolerated, with few side effects except for post-inhalation cough (nemiralisib: 35%; placebo: 9%). At day 14, sputum interleukin (IL)-5, IL-13, IL-6, and IL-8 levels were reduced by a median of 17%, 7%, 15%, and 8%, respectively, when comparing nemiralisib with placebo [n = 15 (IL-5, IL-8) or 16 (IL-6, IL-13); posterior probability of a true ratio >0%: 78%, 64%, 76%, and 63%, respectively]. These results suggest that nemiralisib inhibited PI3Kδ locally; however, this did not translate into meaningful clinical improvement. Further studies will investigate the potential efficacy of nemiralisib in patients with asthma with other specific more severe phenotypes, including those who are colonized with bacteria and frequently exacerbate.


Assuntos
Asma/tratamento farmacológico , Broncodilatadores/administração & dosagem , Indazóis/administração & dosagem , Indóis/administração & dosagem , Oxazóis/administração & dosagem , Piperazinas/administração & dosagem , Administração por Inalação , Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Adulto , Idoso , Asma/metabolismo , Estudos Cross-Over , Método Duplo-Cego , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Fosfatidilinositol 3-Quinases/metabolismo , Capacidade Vital/efeitos dos fármacos , Adulto Jovem
12.
J Allergy Clin Immunol ; 133(4): 989-96, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24582316

RESUMO

BACKGROUND: Approximately 5% to 10% of asthmatic patients achieve incomplete symptom control on current therapies. The association of IL-13 with asthma pathology and reduced corticosteroid sensitivity suggests a potential benefit of anti-IL-13 therapy in refractory asthma. GSK679586, a humanized mAb, inhibits IL-13 binding to both IL-13 receptor α1 and α2. OBJECTIVES: We sought to evaluate the efficacy and safety of GSK679586 in patients with severe asthma refractory to maximally indicated doses of inhaled corticosteroids. METHODS: Patients who remained symptomatic (Asthma Control Questionnaire score ≥1.5) after uptitration to 1000 µg/d fluticasone propionate or greater were randomized to 3 once-monthly intravenous infusions of 10 mg/kg GSK679586 (n = 99) or placebo (n = 99). RESULTS: Treatment differences in adjusted mean change from baseline over 12 weeks were nonsignificant for Asthma Control Questionnaire symptom scores (the primary end point; GSK679586 = -0.31, placebo = -0.17, P = .058) and FEV1 (GSK679586 = -0.01, placebo = 0.03, P = .276). Similar analyses in patients with increased serum IgE levels, blood eosinophil counts, or both were also negative. Incidence of asthma exacerbations was similar between treatments. Most adverse events were nonserious and unrelated to treatment. Two GSK679586-treated patients had treatment-related serious adverse events (lethargy and supraventricular extrasystoles). CONCLUSIONS: Although well tolerated, GSK679586 did not demonstrate clinically meaningful improvements in asthma control, pulmonary function, or exacerbations in patients with severe asthma. Further studies are needed to determine whether therapies targeting IL-13, the functionally related IL-4 cytokine, or both can provide clinical benefit in patients with severe refractory asthma or a subpopulation of these patients beyond that achievable with high-dose corticosteroids.


Assuntos
Antiasmáticos/uso terapêutico , Anticorpos Monoclonais/uso terapêutico , Asma/tratamento farmacológico , Interleucina-13/antagonistas & inibidores , Adulto , Antiasmáticos/efeitos adversos , Antiasmáticos/farmacocinética , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais/farmacocinética , Asma/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Resultado do Tratamento
13.
Thorax ; 68(2): 155-62, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23143842

RESUMO

BACKGROUND: Idiopathic pulmonary fibrosis (IPF) is a fatal condition with limited treatment options. However, in a previous small study, co-trimoxazole was found to be beneficial. METHODS: In a double-blind multicentre study, 181 patients with fibrotic idiopathic interstitial pneumonia (89% diagnosed as definite/probable IPF) were randomised to receive co-trimoxazole 960 mg twice daily or placebo for 12 months in addition to usual care. Measurements were made of forced vital capacity (FVC) (primary endpoint), diffusing capacity of carbon monoxide (Dlco) and EuroQol (EQ5D)-based utility, 6-minute walk test (6MWT) and Medical Research Council (MRC) dyspnoea score (secondary endpoints). All-cause mortality and adverse events were recorded (tertiary endpoints). RESULTS: Co-trimoxazole had no effect on FVC (mean difference 15.5 ml (95% CI -93.6 to 124.6)), Dlco (mean difference -0.12 mmol/min/kPa (95% CI 0.41 to 0.17)), 6MWT or MRC dyspnoea score (intention-to-treat analysis). The findings of the per-protocol analysis were the same except that co-trimoxazole treatment resulted in a significant improvement in EQ5D-based utility (mean difference 0.12 (95% CI 0.01 to 0.22)), a reduction in the percentage of patients requiring an increase in oxygen therapy (OR 0.05 (95% CI 0.00 to 0.61)) and a significant reduction in all-cause mortality (co-trimoxazole 3/53, placebo 14/65, HR 0.21 (95% CI 0.06 to 0.78), p=0.02)) compared with placebo. The use of co-trimoxazole reduced respiratory tract infections but increased the incidence of nausea and rash. CONCLUSIONS: The addition of co-trimoxazole therapy to standard treatment for fibrotic idiopathic interstitial pneumonia had no effect on lung function but resulted in improved quality of life and a reduction in mortality in those adhering to treatment. ISRCTN22201583.


Assuntos
Anti-Infecciosos/uso terapêutico , Fibrose Pulmonar Idiopática/tratamento farmacológico , Combinação Trimetoprima e Sulfametoxazol/uso terapêutico , Idoso , Anti-Infecciosos/administração & dosagem , Método Duplo-Cego , Feminino , Humanos , Fibrose Pulmonar Idiopática/mortalidade , Fibrose Pulmonar Idiopática/fisiopatologia , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Testes de Função Respiratória , Resultado do Tratamento
14.
Br J Clin Pharmacol ; 75(1): 118-28, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22616628

RESUMO

AIMS: IL-13 is implicated as an important mediator of the pathology of asthma. This first clinical study with GSK679586, a novel humanized anti-IL-13 IgG1 monoclonal antibody, evaluated the safety, pharmacokinetics and pharmacodynamics of escalating single and repeat doses of GSK679586. METHODS: In this randomized, double-blind study, healthy subjects received single intravenous infusions of GSK679586 (0.005, 0.05, 0.5, 2.5, 10 mg kg(-1)) or placebo and mild intermittent asthmatics received two once monthly intravenous infusions of GSK679586 (2.5, 10, 20 mg kg(-1)) or placebo. RESULTS: GSK679586 displayed approximately linear pharmacokinetics (based on AUC and C(max)) with limited accumulation upon repeat administration. In mild intermittent asthmatics, treatment with GSK679586 produced an increase in serum total IL-13 concentrations, indicative of GSK679586-IL-13 complex formation. Additionally, mean levels of exhaled nitric oxide (FeNO), a marker of pulmonary inflammation, were reduced relative to baseline at 2.5, 10 and 20 mg kg(-1) doses of GSK679586 at both 2 weeks (19%, 44% and 52% decreases) and 8 weeks (29%, 55% and 42% decreases) after the second infusion. GSK679586 was well tolerated; the incidence of AEs was comparable across all presumed biologically active doses and there were no treatment-related SAEs. CONCLUSIONS: GSK679586 demonstrated dose-dependent pharmacological activity in the lungs of mild intermittent asthmatics. These findings, together with the favourable safety profile and advantageous PK characteristics of a monoclonal antibody (e.g. a long half-life supporting less frequent dosing), warrant further investigation of GSK679586 in a broader asthma patient population.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Asma/tratamento farmacológico , Interleucina-13/antagonistas & inibidores , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais Humanizados/farmacocinética , Testes Respiratórios , Método Duplo-Cego , Humanos , Masculino , Óxido Nítrico/metabolismo
15.
Chest ; 164(3): 700-716, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36965765

RESUMO

BACKGROUND: Microvascular abnormalities and impaired gas transfer have been observed in patients with COVID-19. The progression of pulmonary changes in these patients remains unclear. RESEARCH QUESTION: Do patients hospitalized with COVID-19 without evidence of architectural distortion on structural imaging exhibit longitudinal improvements in lung function measured by using 1H and 129Xe MRI between 6 and 52 weeks following hospitalization? STUDY DESIGN AND METHODS: Patients who were hospitalized with COVID-19 pneumonia underwent a pulmonary 1H and 129Xe MRI protocol at 6, 12, 25, and 51 weeks following hospital admission in a prospective cohort study between November 2020 and February 2022. The imaging protocol was as follows: 1H ultra-short echo time, contrast-enhanced lung perfusion, 129Xe ventilation, 129Xe diffusion-weighted, and 129Xe spectroscopic imaging of gas exchange. RESULTS: Nine patients were recruited (age 57 ± 14 [median ± interquartile range] years; six of nine patients were male). Patients underwent MRI at 6 (n = 9), 12 (n = 9), 25 (n = 6), and 51 (n = 8) weeks following hospital admission. Patients with signs of interstitial lung damage were excluded. At 6 weeks, patients exhibited impaired 129Xe gas transfer (RBC to membrane fraction), but lung microstructure was not increased (apparent diffusion coefficient and mean acinar airway dimensions). Minor ventilation abnormalities present in four patients were largely resolved in the 6- to 25-week period. At 12 weeks, all patients with lung perfusion data (n = 6) showed an increase in both pulmonary blood volume and flow compared with 6 weeks, although this was not statistically significant. At 12 weeks, significant improvements in 129Xe gas transfer were observed compared with 6-week examinations; however, 129Xe gas transfer remained abnormally low at weeks 12, 25, and 51. INTERPRETATION: 129Xe gas transfer was impaired up to 1 year following hospitalization in patients who were hospitalized with COVID-19 pneumonia, without evidence of architectural distortion on structural imaging, whereas lung ventilation was normal at 52 weeks.


Assuntos
COVID-19 , Isótopos de Xenônio , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem
16.
Pulm Circ ; 12(1): e12024, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35506108

RESUMO

Preclinical and early clinical studies suggest that angiotensin-converting enzyme type 2 activity may be impaired in patients with pulmonary arterial hypertension (PAH); therefore, administration of exogenous angiotensin-converting enzyme type 2 (ACE2) may be beneficial. This Phase IIa, multi-center, open-label, exploratory, single-dose, dose-escalation study (NCT03177603) assessed the potential vasodilatory effects of single doses of GSK2586881 (a recombinant human ACE2) on acute cardiopulmonary hemodynamics in hemodynamically stable adults with documented PAH who were receiving background PAH therapy. Successive cohorts of participants were administered a single intravenous dose of GSK2586881 of 0.1, 0.2, 0.4, or 0.8 mg/kg. Dose escalation occurred after four or more participants per cohort were dosed and a review of safety, tolerability, pharmacokinetics, and hemodynamic data up to 24 h postdose was undertaken. The primary endpoint was a change in cardiopulmonary hemodynamics (pulmonary vascular resistance, cardiac index, and mean pulmonary artery pressure) from baseline. Secondary/exploratory objectives included safety and tolerability, effect on renin-angiotensin system peptides, and pharmacokinetics. GSK2586881 demonstrated no consistent or sustained effect on acute cardiopulmonary hemodynamics in participants with PAH receiving background PAH therapy (N = 23). All doses of GSK2586881 were well tolerated. GSK2586881 was quantifiable in plasma for up to 4 h poststart of infusion in all participants and caused a consistent and sustained reduction in angiotensin II and a corresponding increase in angiotensin (1-7) and angiotensin (1-5). While there does not appear to be a consistent acute vasodilatory response to single doses of GSK2586881 in participants with PAH, the potential benefits in terms of chronic vascular remodeling remain to be determined.

17.
Pulm Ther ; 7(2): 487-501, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34189703

RESUMO

INTRODUCTION: Angiotensin-converting enzyme 2 (ACE2) is a key enzyme of the renin-angiotensin system (RAS) that has been implicated in the pathogenesis of acute respiratory distress syndrome (ARDS). Enhancing ACE2 activity using GSK2586881, a recombinant form of human ACE2, could be beneficial in diseases such as ARDS but may blunt the hypoxic pulmonary vasoconstriction (HPV) response and potentially impact systemic and tissue oxygenation. This study aimed to evaluate the effect of GSK2586881 0.8 mg/kg on HPV response in healthy adult volunteers during exercise under hypoxic conditions. METHODS: In this phase I, randomised, double-blind (sponsor open) study, GSK2586881 or placebo was administered as a single intravenous (IV) dose in a two-period crossover design. Treatment periods were separated by a washout period of 3-14 days. The primary endpoint was change from baseline in pulmonary artery systolic pressure (PASP) measured by echocardiography. Secondary endpoints included RAS peptides and oxygen saturation. RESULTS: Seventeen adults aged 18-40 years were randomised to treatment. There were no clinically relevant differences (defined as a reduction of ≥ 5 mmHg) in change from baseline in PASP between GSK2586881 and placebo. GSK2586881 was well tolerated, with no serious adverse events, no worsening of hypoxaemia and no evidence of immunogenicity. The study was terminated early after review of the data, which showed that the predefined success criteria had not been met. Following GSK2586881 administration, levels of the RAS peptide angiotensin II decreased while angiotensin (1-7) increased, as expected, indicating that GSK2586881 was pharmacologically active. CONCLUSIONS: A single IV dose of GSK2586881 0.8 mg/kg was well tolerated but did not impact the acute HPV response in healthy volunteers.

18.
Int J Chron Obstruct Pulmon Dis ; 16: 1637-1646, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113095

RESUMO

Background: Management of acute exacerbations of chronic obstructive pulmonary disease (COPD) is sometimes inadequate leading to either prolonged duration and/or an increased risk of recurrent exacerbations in the period following the initial event. Objective: To evaluate the safety and efficacy of inhaled nemiralisib, a phosphoinositide 3-kinase δ inhibitor, in patients experiencing an acute exacerbation of COPD. Patients and Methods: In this double-blind, placebo-controlled study, COPD patients (40-80 years, ≥10 pack-year smoking history, current moderate/severe acute exacerbation of COPD requiring standard-of-care treatment) were randomized to placebo or nemiralisib 12.5 µg, 50 µg, 100 µg, 250 µg, 500 µg, or 750 µg (ratio of 3:1:1:1:1:1:3; N=938) for 12 weeks with an exploratory 12-week follow-up period. The primary endpoint was change from baseline in post-bronchodilator FEV1 at week 12. Key secondary endpoints were rate of re-exacerbations, patient-reported outcomes (Exacerbations of Chronic Pulmonary Disease Tool, COPD Assessment Test, St George's Respiratory Questionnaire-COPD), plasma pharmacokinetics (PK) and safety/tolerability. Results: There was no difference in change from baseline FEV1 at week 12 between the nemiralisib and placebo treatment groups (posterior adjusted median difference, nemiralisib 750 µg and placebo: -0.004L (95% CrI: -0.051L to 0.042L)). Overall, there were also no differences between nemiralisib and placebo in secondary endpoints, including re-exacerbations. Plasma PK increased in a dose proportional manner. The most common adverse event for nemiralisib was post-inhalation cough which appeared to be dose-related. Conclusion: The addition of nemiralisib to standard-of-care treatment for 12 weeks did not improve lung function or re-exacerbations in patients with, and following an acute exacerbation of COPD. However, this study demonstrated that large clinical trials recruiting acutely exacerbating patients can successfully be conducted.


Assuntos
Fosfatidilinositol 3-Quinases , Doença Pulmonar Obstrutiva Crônica , Broncodilatadores/uso terapêutico , Método Duplo-Cego , Volume Expiratório Forçado , Humanos , Indazóis , Indóis , Oxazóis/farmacologia , Oxazóis/uso terapêutico , Fosfatidilinositol 3-Quinases/farmacologia , Fosfatidilinositol 3-Quinases/uso terapêutico , Piperazinas , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico
19.
Int J Chron Obstruct Pulmon Dis ; 16: 1607-1619, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113093

RESUMO

Purpose: This study evaluated the safety and efficacy of inhaled nemiralisib, a phosphoinositide 3-kinase δ (PI3Kδ) inhibitor, in patients with an acute exacerbation of chronic obstructive pulmonary disease (COPD). Methods: In this double-blind, placebo-controlled study, 126 patients (40-80 years with a post-bronchodilator forced expiratory volume in 1 sec (FEV1) ≤80% of predicted (previously documented)) were randomized 1:1 to once daily inhaled nemiralisib (1 mg) or placebo for 84 days, added to standard of care. The primary endpoint was specific imaging airway volume (siVaw) after 28 treatment days and was analyzed using a Bayesian repeated measures model (clintrials.gov: NCT02294734). Results: A total of 126 patients were randomized to treatment; 55 on active treatment and 49 on placebo completed the study. When comparing nemiralisib and placebo-treated patients, an 18% placebo-corrected increase from baseline in distal siVaw (95% credible intervals (Cr I) (-1%, 42%)) was observed on Day 28. The probability that the true treatment ratio was >0% (Pr(θ>0)) was 96%, suggestive of a real treatment effect. Improvements were observed across all lung lobes. Patients treated with nemiralisib experienced a 107.3 mL improvement in posterior median FEV1 (change from baseline, 95% Cr I (-2.1, 215.5)) at day 84, compared with placebo. Adverse events were reported by 41 patients on placebo and 49 on nemiralisib, the most common being post-inhalation cough on nemiralisib (35%) vs placebo (3%). Conclusion: These data show that addition of nemiralisib to usual care delivers more effective recovery from an acute exacerbation and improves lung function parameters including siVaw and FEV1. Although post-inhalation cough was identified, nemiralisib was otherwise well tolerated, providing a promising novel therapy for this acutely ill patient group.


Assuntos
Fosfatidilinositol 3-Quinases , Doença Pulmonar Obstrutiva Crônica , Administração por Inalação , Teorema de Bayes , Broncodilatadores/uso terapêutico , Método Duplo-Cego , Volume Expiratório Forçado , Humanos , Fosfatidilinositol 3-Quinases/farmacologia , Fosfatidilinositol 3-Quinases/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Resultado do Tratamento
20.
Int J Chron Obstruct Pulmon Dis ; 16: 1621-1636, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34113094

RESUMO

Background: Inhibition of phosphoinositide 3-kinase δ (PI3Kδ) exerts corrective effects on the dysregulated migration characteristics of neutrophils isolated from patients with chronic obstructive pulmonary disease (COPD). Objective: To develop novel, induced sputum endpoints to demonstrate changes in neutrophil phenotype in the lung by administering nemiralisib, a potent and selective inhaled PI3Kδ inhibitor, to patients with stable COPD or patients with acute exacerbation (AE) of COPD. Methods: In two randomized, double-blind, placebo-controlled clinical trials patients with A) stable COPD (N=28, randomized 3:1) or B) AECOPD (N=44, randomized 1:1) received treatment with inhaled nemiralisib (1mg). Endpoints included induced sputum at various time points before and during treatment for the measurement of transcriptomics (primary endpoint), inflammatory mediators, functional respiratory imaging (FRI), and spirometry. Results: In stable COPD patients, the use of nemiralisib was associated with alterations in sputum neutrophil transcriptomics suggestive of an improvement in migration phenotype; however, the same nemiralisib-evoked effects were not observed in AECOPD. Inhibition of sputum inflammatory mediators was also observed in stable but not AECOPD patients. In contrast, a placebo-corrected improvement in forced expiratory volume in 1 sec of 136 mL (95% Credible Intervals -46, 315mL) with a probability that the true treatment ratio was >0% (Pr(θ>0)) of 93% was observed in AECOPD. However, FRI endpoints remained unchanged. Conclusion: We provide evidence for nemiralisib-evoked changes in neutrophil migration phenotype in stable COPD but not AECOPD, despite improving lung function in the latter group. We conclude that induced sputum can be used for measuring evidence of alteration of neutrophil phenotype in stable patients, and our study provides a data set of the sputum transcriptomic changes during recovery from AECOPD.


Assuntos
Fosfatidilinositol 3-Quinases , Doença Pulmonar Obstrutiva Crônica , Progressão da Doença , Volume Expiratório Forçado , Humanos , Fosfatidilinositol 3-Quinase , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/genética , Ensaios Clínicos Controlados Aleatórios como Assunto , Escarro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA