1.
Biochem Cell Biol ; 101(1): 52-63, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36542845

RESUMO

Metabolic syndrome (MetS) represents a cluster of diseases that includes diabetes and insulin resistance. A combination of these metabolic disorders damages liver function. We hypothesized here that histone deacetylase 1 (HDAC1) inhibits fibroblast growth factor 21 (FGF21) expression through histone deacetylation, thereby accentuating liver injury in rats with MetS. MetS rats induced by a high-fat diet were monitored weekly for blood pressure and body weight measurement. The changes of hepatic injury parameters were also measured. The pathological changes in the liver were observed by HE staining and oil red O staining. We found that HDAC1 was increased in the liver of rats with MetS, while sh-HDAC1 reduced blood pressure, body weight, and hepatic injury parameters. Improvement of structural pathological alterations and reduction of lipid deposition were observed after HDAC1 inhibition. Notably, HDAC1 inhibited FGF21 expression through histone deacetylation. The hepatoprotective effects of sh-HDAC1 on rats were reversed by adenovirus-mediated knockdown of FGF21. Moreover, methyltransferase-like 3 (METTL3) mediated the N6-methyladenosine (m6A) modification of HDAC1 mRNA and increased its binding to IGF2BP2. Consistently, sh-METTL3 inhibited HDAC1 and increased FGF21 expression, thereby ameliorating liver injury in MetS rats. This study discovered that HDAC1 is capable of managing liver injury in MetS. Targeting HDAC1 may be an optimal treatment for MetS-related liver injury.


Assuntos
Síndrome Metabólica , Animais , Ratos , Peso Corporal , Histona Desacetilase 1/genética , Histonas/metabolismo , Fígado/metabolismo , Síndrome Metabólica/metabolismo
2.
Immun Inflamm Dis ; 11(7): e943, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37506152

RESUMO

OBJECTIVE: Pyogenic liver abscess (PLA) is a common surgical infectious disease caused by various pathogens. Klebsiella pneumoniae is a relatively recent cause, often affecting patients with low immunity. Endogenous endophthalmitis (EE), a rare and serious complication of PLA, may appear with eye symptoms before PLA. By reviewing a case of Klebsiella pneumoniae-induced PLA complicated with EE, we want to summarize the information about the characteristics, causes, and complications of PLA based on the literature review. METHODS: This case report describes a 37-year-old male who had fever high to 39°C for 10 days experienced blurred vision followed by nonlight perception vision. He reported a history of diabetes irregularly taking oral medications and insulin therapy. Imaging examination found a large low-density area in the right lobe of the liver with an unclear border and vague surrounding fat gap. The blood culture was not positive. The culture of the drainage fluid from the liver puncture showed Klebsiella pneumonia. Blood and liver puncture drainage fluid were sent for microbial high-throughput gene detection with next-generation sequencing technology (NGS), which confirmed the diagnosis of Klebsiella pneumoniae-induced PLA complicated with EE. RESULTS: The patient's surgical incision had healed well at discharge, and he could feel light at his left eye. But the patient was lost to follow-up since the third month after discharge. CONCLUSION: By reviewing this case and summarize the information about the characteristics, causes, and complications of PLA based on the literature review, we concluded that it is necessary to promptly perform liver puncture drainage and empirically use antibiotics for patients with PLA, especially those with poor glycemic control, to avoid serious complications such as EE.


Assuntos
Endoftalmite , Infecções por Klebsiella , Abscesso Hepático Piogênico , Masculino , Humanos , Adulto , Abscesso Hepático Piogênico/diagnóstico , Abscesso Hepático Piogênico/terapia , Abscesso Hepático Piogênico/complicações , Klebsiella pneumoniae/genética , Antibacterianos/uso terapêutico , Infecções por Klebsiella/complicações , Infecções por Klebsiella/diagnóstico , Infecções por Klebsiella/tratamento farmacológico , Endoftalmite/diagnóstico , Endoftalmite/etiologia , Endoftalmite/terapia
3.
Nanoscale ; 15(1): 80-91, 2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36512329

RESUMO

As a lab-on-soft biochip providing accurate and timely biomarker information, wearable biosensors can satisfy the increasing demand for intelligent e-health services, active disease diagnosis/therapy, and huge bioinformation data. As biomolecules generally could not directly produce detectable signals, biotransducers that specifically convert biomolecules to electrical or optical signals are involved, which determines the pivotal sensing performance including 3S (sensitivity, selectivity, and stability), reversibility, etc. The soft interface poses new requirements for biotransducers, especially equipment-free, facile operation, mechanical tolerance, and high sensing performance. In this review, we discussed the emerging electrochemical and optical biotransduction strategies on wearables from the aspects of the transduction mechanism, amplification strategies, biomaterial selection, and device fabrication procedures. Challenges and perspectives regarding future biotransducers for monitoring trace amounts of biomolecules with high fidelity, sensitivity, and multifunctionality are also discussed. It is expected that through fusion with functional electronics, wearable biosensors can provide possibilities to further decentralize the healthcare system and even build biomolecule-based intelligent cyber-physical systems and new modalities of cyborgs.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Técnicas Biossensoriais/métodos , Eletrônica , Materiais Biocompatíveis , Biomarcadores
4.
Artigo em Inglês | MEDLINE | ID: mdl-33792236

RESUMO

BACKGROUND: The associations of cardiovascular autonomic neuropathy (CAN) with diabetic nephropathy and heart disease remain elusive. The aim of this study was to explore the correlations of CAN with urinary albumin excretion rate (UAER) and cardiac function in patients with type 2 diabetes mellitus (T2DM). METHODS: A total of 225 T2DM patients were assigned into CAN and non-CAN groups using cardiovascular reflex tests (CARTs). They were divided into macroalbuminuria, microalbuminuria and normoalbuminuria groups according to urinary albumin/creatinine ratio (UACR), or left ventricular diastolic dysfunction and normal groups based on left ventricular peak E/A velocity ratio (E/A). The correlations of CAN with albuminuria and left ventricular diastolic dysfunction, and the predictive values of UACR and E/A were analyzed. RESULTS: Compared with non-CAN group, CAN group had older age, longer T2DM duration, higher serum urine acid (SUA) level, UACR, systolic and diastolic pressure differences between supine and standing positions, and lower other CARTs parameters and E/A (P<0.001). Macroalbuminuria group had largest positional systolic and diastolic pressure differences, and lowest other CARTs parameters (P<0.001). Compared with normal group, left ventricular diastolic dysfunction group had larger positional systolic and diastolic pressure differences, and lower other CARTs parameters (P<0.001). CAN in T2DM patients was positively correlated with albuminuria and left ventricular diastolic dysfunction (P<0.001). Age, SUA, UACR and E/A were independent predictive factors (P=0.031, 0.005, <0.001, <0.001). UACR and E/A had high predictive values. CONCLUSIONS: In T2DM patients, CAN is positively correlated with declined UAER and cardiac function. UACR and E/A have high predictive values.

5.
Zhonghua Xin Xue Guan Bing Za Zhi ; 35(3): 237-40, 2007 Mar.
Artigo em Zh | MEDLINE | ID: mdl-17582288

RESUMO

OBJECTIVE: To analyze the clinical factors relating to arterial elastic function measured with pulse wave velocity (PWV), large and small arterial elastic indexes (C(1) and C(2)) and augmentation index (AI) in hypertensive patients. METHODS: A total of 2176 hypertensive patients were enrolled and divided into three groups: Elastic function was measured in 1100 subjects by (PWV), in 647 subjects by C(1) and C(2) and in 429 by AI. RESULTS: PWV was positively correlated with age, systolic pressure, pulse pressure and negatively correlated with body height and weights (all P < 0.05). C(1) and C(2) values were higher in male than that in female patients (P < 0.01) and negatively correlated with age, systolic pressure, pulse pressure and heart rate while positively correlated with body height, weight and body mass index. In hypercholesterolemia patients (n = 168), C(1) and C(2) were negatively correlated with serum cholesterol level (P < 0.05). AI value was higher in female than that in male patients (P < 0.01) and positively correlated with age, systolic pressure, diastolic pressure, pulse pressure while negatively correlated with body height, weight and heart rate. CONCLUSION: Age, systolic and pulse pressure as well as body height and weights are the main factors correlated to arterial elastic function measured by PWV, C(1) and C(2) and AI.


Assuntos
Artérias/fisiopatologia , Hipertensão/fisiopatologia , Pulso Arterial , Fatores Etários , Idoso , Pressão Sanguínea , Estatura , Peso Corporal , Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Sci Rep ; 6: 29534, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27390070

RESUMO

Although graphene is a typical two dimensional materials, it has converted to multi-dimensional materials with many unique properties. As an example, the one dimensional graphene fiber is fabricated by utilizing ionic liquid as coagulation and functional diamines as cross-linkers to connect graphene oxide layers. The fibers show excellent mechanical properties and superior electrical performance. The tensile strength of the resultant fibers reaches ~729 MPa after a super high temperature thermal annealing treatment at 2800 °C. Additionally, quasi-solid-state flexible micro-capacitors are fabricated with promising result on energy storage. The device show a specific volumetric capacity as high as ~225 F/cm(3) (measured at 103.5 mA cm(-3) in a three-electrode cell), as well as a long cycle life of 2000 times. The initial results indicate that these fibers will be a good candidate to replace energy storage devices for miniaturized portable electronic applications.

7.
Nanoscale Res Lett ; 10: 55, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25852352

RESUMO

We demonstrated one-step method to fabricate two different sizes of graphene quantum dots (GQDs) through chemical cutting from graphene oxide (GO), which had many advantages in terms of simple process, low cost, and large scale in manufacturing with higher production yield comparing to the reported methods. Several analytical methods were employed to characterize the composition and morphology of the resultants. Bright blue luminescent GQDs were obtained with a produced yield as high as 34.8%. Moreover, how the different sizes affect fluorescence wavelength mechanism was investigated in details.

8.
Nanoscale Res Lett ; 10: 192, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25977663

RESUMO

We reported a simple and effective way of fabricating one-dimensional (1D) graphene oxide nanoscrolls (GONS) from graphene oxide (GO) sheets through shock cooling by liquid nitrogen. The corresponding mechanism of rolling was proposed. One possibility is the formation of ice crystals during the shock cooling process in liquid nitrogen to be the driving force. The other might be due to the uneven stress of the sheets inside or outside ice during the lyophilization. After reducing, graphene nanoscrolls (GNS) exhibited good structural stability, high specific surface area, and high specific capacitance. The capacitance properties were investigated by cyclic voltammetry, galvanostatic charge-discharge, and electrical impedance spectroscopy. A specific capacity of 156 F/g for the GNS at the current density of 1.0 A/g was obtained comparing with the specific capacity of 108 F/g for graphene sheets. Those results indicated that GNS-based rolling structure could be a kind of promising electrode material for supercapacitors and batteries.