Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Respir Res ; 25(1): 264, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965590

RESUMO

BACKGROUND: Bronchoscopic lung volume reduction (BLVR) with one-way endobronchial valves (EBV) has better outcomes when the target lobe has poor collateral ventilation, resulting in complete lobe atelectasis. High-inspired oxygen fraction (FIO2) promotes atelectasis through faster gas absorption after airway occlusion, but its application during BLVR with EBV has been poorly understood. We aimed to investigate the real-time effects of FIO2 on regional lung volumes and regional ventilation/perfusion by electrical impedance tomography (EIT) during BLVR with EBV. METHODS: Six piglets were submitted to left lower lobe occlusion by a balloon-catheter and EBV valves with FIO2 0.5 and 1.0. Regional end-expiratory lung impedances (EELI) and regional ventilation/perfusion were monitored. Local pocket pressure measurements were obtained (balloon occlusion method). One animal underwent simultaneous acquisitions of computed tomography (CT) and EIT. Regions-of-interest (ROIs) were right and left hemithoraces. RESULTS: Following balloon occlusion, a steep decrease in left ROI-EELI with FIO2 1.0 occurred, 3-fold greater than with 0.5 (p < 0.001). Higher FIO2 also enhanced the final volume reduction (ROI-EELI) achieved by each valve (p < 0.01). CT analysis confirmed the denser atelectasis and greater volume reduction achieved by higher FIO2 (1.0) during balloon occlusion or during valve placement. CT and pocket pressure data agreed well with EIT findings, indicating greater strain redistribution with higher FIO2. CONCLUSIONS: EIT demonstrated in real-time a faster and more complete volume reduction in the occluded lung regions under high FIO2 (1.0), as compared to 0.5. Immediate changes in the ventilation and perfusion of ipsilateral non-target lung regions were also detected, providing better estimates of the full impact of each valve in place. TRIAL REGISTRATION: Not applicable.


Assuntos
Broncoscopia , Impedância Elétrica , Animais , Suínos , Broncoscopia/métodos , Pneumonectomia/métodos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Pulmão/cirurgia , Pulmão/fisiologia , Tomografia/métodos , Atelectasia Pulmonar/diagnóstico por imagem , Atelectasia Pulmonar/fisiopatologia , Medidas de Volume Pulmonar/métodos , Fatores de Tempo
2.
Artif Organs ; 45(7): 748-753, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33350476

RESUMO

Tracheal stenosis in children is a challenge for the healthcare team, since it is a rare disease. Patients usually have other clinical comorbidities, mainly previous cardiac surgical interventions. This retrospective single-center study included infants with tracheal stenosis (congenital or acquired) operated between 2016 and 2020 on venoarterial extracorporeal membrane oxygenation (VA ECMO). Five patients were operated and the median age of detection of the tracheal disease was 3.7 months, and the median age at the operation was 5 months. All patients had associated cardiac anomalies. Four patients had congenital tracheal stenosis; two with associated pig bronchus. One patient had acquired subglottic stenosis with concomitant stenosis at the carina. After the operation, the patients were referred to ICU on ECMO with an open chest. Minor ECMO-related complications occurred in two patients (hemothorax and wound infection). All patients required endoscopic evaluation during the postoperative care; median of 3.2 procedures. Two patients are currently in follow-up and three have died. Slide tracheoplasty with VA-ECMO can be successfully performed in infants with prior cardiac surgery. Nevertheless, a difficult postoperative course should be anticipated, with possible prolonged ECMO use, readmissions, and higher morbidity and mortality than in children with tracheal stenosis alone.


Assuntos
Oxigenação por Membrana Extracorpórea , Estenose Traqueal/cirurgia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Cardiopatias Congênitas/complicações , Hemotórax/etiologia , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Estenose Traqueal/complicações , Estenose Traqueal/mortalidade , Infecção dos Ferimentos/etiologia
3.
Artif Organs ; 44(5): 504-512, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31715014

RESUMO

Mechanical evaluation of tracheal grafts is of great relevance for transplant research. Although there are some publications demonstrating different techniques of tracheal mechanical evaluation, there is still no definitive or preferred protocol available. Here, we present a simple image processing acquisition system that can be used for in vivo experiments. Six male Wistar rats were submitted to orotracheal intubation and a longitudinal incision was made to expose the trachea. Images of tracheae were acquired from a video camera in different scenarios of bronchoconstriction using methacholine (MCh) (Basal, PBS, MCh 30 µg/kg, MCh 300 µg/kg, and postmetabolized) during imposed-inspiration and imposed-expiration. The area variation ratio (the ratio between areas during expiration vs. inspiration) was 1.1× for the Basal group, while the ratio for MCh 300 µg/kg was 6.5×. The area variation of imaged tracheae was statistically significant at the dose of MCh 300 µg/kg for imposed-inspiration versus imposed-expiration (P = .002). Likewise, elastance data of respiratory mechanics indicated a statistically significant difference at the dose of MCh 300 µg/kg for imposed-inspiration versus imposed-expiration (P = .026). Our image processing analysis protocol presented corresponding behavior when compared to mechanical parameters of the respiratory system. In addition, our image acquisition system was able to highlight the differences between imposed-inspiration and imposed-expiration. Image analysis of the tracheal area variation seems to be in agreement with the elastance of the respiratory system. Taken together, these observations may help future studies of tracheal transplantation for in situ assessment of graft patency.


Assuntos
Broncoconstrição , Traqueia/diagnóstico por imagem , Animais , Processamento de Imagem Assistida por Computador , Masculino , Ratos Wistar , Traqueia/fisiologia
4.
Lasers Med Sci ; 34(7): 1441-1448, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30762192

RESUMO

To evaluate the feasibility of a 980-nm contact diode laser (CDL) as a method for creating a posterior laryngofissure in live pigs. Twenty-eight Landrace pigs (15-20 kg) were anesthetized, intubated, ventilated, and submitted to a cervical tracheostomy. An anterior and posterior midline longitudinal laryngofissure incision was created according to randomization-control (n = 4), posterior laryngofissure with a scalpel blade; electrocautery (n = 12), posterior laryngofissure by electrocautery (10, 15, 20, 25 W powers); CDL (n = 12), posterior laryngofissure by the CDL (10, 15, 20, 25 W peak powers in pulsed mode). Larynx and proximal trachea were excised, prepared for histopathology, and digital morphometric analysis. Measurements in and within each group were analyzed (Kruskal-Wallis and Dunn test) with a level of significance of p < 0.05. Incision width was not different between the groups, as well as in the powers used in CDL (p = 0.161) and electrocautery group (p = 0.319). The depth of the incisions was smaller in the Laser group compared to control (p = 0.007), and in the electrocautery compared to control (p = 0.026). Incision area was smaller in CDL compared with the control (p = 0.027), and not different between laser and electrocautery groups (p = 0.199). The lateral thermal damage produced by electrocautery was the largest, with a significant difference between laser and electrocautery (p = 0.018), and between electrocautery and control (p = 0.004), whereas the comparison between laser and control showed no significant differences (p = 0.588). The posterior laryngofissure incision using a 980-nm CDL is feasible resulting in smaller incisional area and less lateral thermal damage.


Assuntos
Laringe/cirurgia , Lasers Semicondutores , Animais , Eletrocoagulação , Estudos de Viabilidade , Terapia a Laser/métodos , Suínos
5.
Bioengineering (Basel) ; 11(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38534535

RESUMO

Cilia are biological structures essential to drive the mobility of secretions and maintain the proper function of the respiratory airways. However, this motile self-cleaning process is significantly compromised in the presence of silicone tracheal prosthesis, leading to biofilm growth and impeding effective treatment. To address this challenge and enhance the performance of these devices, we propose the fabrication of magnetic silicone cilia, with the prospect of their integration onto silicone prostheses. The present study presents a fabrication method based on magnetic self-assembly and assesses the interaction behavior of the cilia array with biological mucus. This protocol allows for the customization of cilia dimensions across a wide range of aspect ratios (from 6 to 85) and array densities (from 10 to 80 cilia/mm2) by adjusting the fabrication parameters, offering flexibility for adjustments according to their required characteristics. Furthermore, we evaluated the suitability of different cilia arrays for biomedical applications by analyzing their interaction with bullfrog mucus, simulating the airways environment. Our findings demonstrate that the fabricated cilia are mechanically resistant to the viscous fluid and still exhibit controlled movement under the influence of an external moving magnet. A correlation between cilia dimensions and mucus wettability profile suggests a potential role in facilitating mucus depuration, paving the way for further advancements aimed at enhancing the performance of silicone prostheses in clinical settings.

6.
Microorganisms ; 12(1)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38257957

RESUMO

Despite the excellent properties of silicone endotracheal prostheses, their main limitation is the formation of a polymicrobial biofilm on their surfaces. It can cause local inflammation, interfering with the local healing process and leading to further complications in the clinical scenario. The present study evaluated the inhibitory effect of cold atmospheric plasma (CAP) on multispecies biofilms grown on the silicone protheses' surfaces. In addition to silicone characterization before and after CAP exposure, CAP cytotoxicity on immortalized human bronchial epithelium cell line (BEAS-2B) was evaluated. The aging time test reported that CAP could temporarily change the silicone surface wetting characteristics from hydrophilic (80.5°) to highly hydrophilic (<5°). ATR-FTIR showed no significant alterations in the silicone surficial chemical composition after CAP exposure for 5 min. A significant log reduction in viable cells in monospecies biofilms (log CFU/mL) of C. albicans, S. aureus, and P. aeruginosa (0.636, 0.738, and 1.445, respectively) was detected after CAP exposure. Multispecies biofilms exposed to CAP showed significant viability reduction for C. albicans and S. aureus (1.385 and 0.831, respectively). The protocol was not cytotoxic to BEAS-2B. CAP can be a simple and effective method to delay multispecies biofilm formation inside the endotracheal prosthesis.

7.
Mediators Inflamm ; 2013: 193484, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24453412

RESUMO

BACKGROUND: The aim of this study was to evaluate the use of liquid perfluorocarbon (PFC) as an adjuvant substance for lung preservation and assess its role in pulmonary protection after transplantation. METHODS: Seventy-two rat lungs were flushed with low-potassium dextran (LPD) solution and randomized into three main groups: control with LPD alone and experimental with 3 (PFC3) and 7 mL/kg (PFC7) of endobronchial PFC instilled just after harvest. Each group was divided into four subgroups according to preservation time (3, 6, 12, and 24 hours). Afterwards, we performed lung transplantation using rat lungs preserved for 12 hours with LPD alone or with 7 mL/kg of endobronchial PFC. RESULTS: There was a significant increase in oxidative stress in the control group at 6 h of cold ischemic time compared with the PFC3 and PFC7 groups. The apoptotic activity and NF-κB expression were significantly higher in the control group compared with the PFC groups at 3, 12, and 24 h of cold preservation. After transplantation, the NF-κB, iNOS, and nitrotyrosine expression as well as caspase 3 activity were significantly lower in the PFC groups. CONCLUSION: The use of endobronchial PFC as an adjuvant to the current preservation strategy improved graft viability.


Assuntos
Fluorocarbonos/farmacologia , Inflamação/prevenção & controle , Transplante de Pulmão , Preservação de Órgãos/métodos , Animais , Brônquios/efeitos dos fármacos , Peroxidação de Lipídeos , Masculino , Modelos Animais , Estresse Oxidativo , Ratos , Ratos Wistar , Traumatismo por Reperfusão/prevenção & controle
8.
Clinics (Sao Paulo) ; 77: 100071, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35759922

RESUMO

OBJECTIVE: To investigate the clinical and swallowing indicators related to a successful decannulation process during the hospital stay. METHODS: A retrospective cohort clinical study. The study sample comprised a heterogeneous patient population who had submitted to a tracheostomy procedure in a tertiary hospital. Patients were divided into two groups (decannulated vs. non-decannulated) and compared not only in terms of demographic and clinical data but also the results of a swallowing assessment and intervention outcome. RESULTS: Sixty-four patients were included in the present study: 25 (39%) who had been successfully decannulated, and 39 (61%) who could not be decannulated. Between-group comparisons indicated that both groups presented similar clinical and demographic characteristics. The groups also presented similar swallowing assessment results prior to intervention. However, significant differences were observed regarding the time to begin swallowing rehabilitation. The decannulated group was assessed nine days earlier than the non-decannulated group. Other significant differences included the removal of the alternate feeding method (72.0% of decannulated patients vs. 5.1% of non-decannulated patients) and the reintroduction of oral feeding (96.0% of decannulated patients vs. 41.0% of non-decannulated patients) and functional swallowing level at patient disclosure. The non-decannulated patient group presented higher death rates at disclosure. CONCLUSION: The results of the present study indicated that the following parameters were associated with a successful decannulation process: early swallowing assessment, swallowing rehabilitation, and improvement in the swallowing functional level during the hospital stay. The maintenance of low swallowing functional levels was found to be negatively associated with successful decannulation.


Assuntos
Deglutição , Remoção de Dispositivo , Humanos , Tempo de Internação , Estudos Retrospectivos , Traqueostomia
9.
PLoS One ; 17(6): e0270107, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35709233

RESUMO

The purpose of this research was to identify risk factors that were independently related to the maintenance of a swallowing dysfunction in patients affected by critical COVID-19. We conducted a prospective observational cohort study of critical patients with COVID-19, who were admitted to a COVID-19 dedicated intensive care unit (ICU) and required prolonged orotracheal intubation (≥48 hours). Demographic and clinical data were collected at ICU admission and/or at hospital discharge or in-hospital death. Swallowing data was based on The Functional Oral Intake Scale (FOIS) and was collected at two distinct moments: initial swallowing assessment and at patient outcome. Patients were divided into two groups according to their FOIS level assigned on the last swallowing assessment: in-hospital resolved dysphagia-patients with FOIS levels 6 and 7; non-resolved dysphagia at hospital outcome-patients with FOIS levels 1 to 5. Nine hundred and twenty patients were included in our study. Results of the multivariate logistic regression model for the prediction of non-resolved dysphagia at hospital outcome in critical COVID-19 patients. indicated that increasing age (p = 0.002), severity at admission (p = 0.015), body mass index (p = 0.008), use of neuromuscular blockers (p = 0.028), presence of neurologic diseases (p = 0.038), presence of Diabetes Mellitus (p = 0.043) and lower FOIS levels on the initial swallowing assessment (p<0.001) were associated with higher chances of presenting dysphagia at hospital outcome. Critical patients with COVID-19 may experience post-acute COVID-19 dysphagia, indicating the need to prepare for the care/rehabilitation of these patients.


Assuntos
COVID-19 , Transtornos de Deglutição , Brasil/epidemiologia , COVID-19/complicações , COVID-19/epidemiologia , Transtornos de Deglutição/epidemiologia , Transtornos de Deglutição/etiologia , Surtos de Doenças , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Estudos Prospectivos
10.
Transl Cancer Res ; 9(3): 2123-2135, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35117568

RESUMO

Benign airway stenosis is a multifactorial and heterogeneous disease often occurring after tracheal intubation. Despite the frequent finding of pathological gastroesophageal reflux (GER) in benign tracheal stenosis, the cause-and-effect relationship between these two entities and its impact on the outcome of the stenosis itself have not been established. The altered ventilatory dynamics caused by an increased thoracoabdominal pressure gradient in such patients has been proposed as a central cause. The presence of GER in a setting of microaspiration can also induce changes in the local collagen proliferation response, as well as in the local microbiome of the tracheal stenosis site, which may potentially cause and enhance the harm imposed to the already diseased tracheal wall. Diagnosis of GER remains underestimated in the general population, thus making its accurate detection and treatment in central airway stenosis a matter of investigation. The high prevalence of GER in tracheal stenosis patients often occurs in the absence of typical upper digestive signs and symptoms, therefore requiring an objective assessment using a 24-hour ambulatory esophageal pH/impedance study that has shown abnormal results in more than half the patients. The impact of the treatment of GER in patients with benign tracheal has been scarcely reported. Our group showed recently that the surgical control of GER through laparoscopic fundoplication in selected patients with tracheal stenosis can improve substantially the chance of resolution of the tracheal stenosis as opposed to the medical management with high dose proton pump inhibitors. This chapter describes the impact of GER in the pathogenesis of tracheal stenosis with a focus on its mechanisms, diagnosis and treatment strategy.

11.
J Bras Pneumol ; 46(6): e20190221, 2020.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33111752

RESUMO

OBJECTIVE: Lung cancer (LC) is one of the leading causes of death worldwide. Accurate mediastinal staging is mandatory in order to assess prognosis and to select patients for surgical treatment. EBUS-TBNA is a minimally invasive procedure that allows sampling of mediastinal lymph nodes (LNs). Some studies have suggested that EBUS-TBNA is preferable to surgical mediastinoscopy for mediastinal staging of LC. The objective of this systematic review and meta-analysis was to compare EBUS-TBNA and mediastinoscopy in terms of their effectiveness for mediastinal LN staging in potentially operable non-small cell lung cancer (NSCLC). METHODS: This was a systematic review and meta-analysis, in which we searched various databases. We included studies comparing the accuracy of EBUS-TBNA with that of mediastinoscopy for mediastinal LN staging in patients with NSCLC. In the meta-analysis, we calculated sensitivity, specificity, positive likelihood ratios, and negative likelihood ratios. We also analyzed the risk difference for the reported complications associated with each procedure. RESULTS: The search identified 4,201 articles, 5 of which (with a combined total of 532 patients) were selected for inclusion in the meta-analysis. There were no statistically significant differences between EBUS-TBNA and mediastinoscopy in terms of the sensitivity (81% vs. 75%), specificity (100% for both), positive likelihood ratio (101.03 vs. 95.70), or negative likelihood ratio (0.21 vs. 0.23). The area under the summary ROC curve was 0.9881 and 0.9895 for EBUS-TBNA and mediastinoscopy, respectively. Although the number of complications was higher for mediastinoscopy, the difference was not significant (risk difference: -0.03; 95% CI: -0.07 to 0.01; I2 = 76%). CONCLUSIONS: EBUS-TBNA and mediastinoscopy produced similar results for mediastinal staging of NSCLC. EBUS-TBNA can be the procedure of first choice for LN staging in patients with NSCLC.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Linfonodos/cirurgia , Neoplasias do Mediastino/diagnóstico por imagem , Neoplasias do Mediastino/patologia , Mediastinoscopia/métodos , Mediastino/diagnóstico por imagem , Broncoscopia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Endoscopia , Humanos , Neoplasias Pulmonares/cirurgia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Neoplasias do Mediastino/cirurgia , Mediastino/cirurgia , Estadiamento de Neoplasias , Sensibilidade e Especificidade
12.
J Bras Pneumol ; 46(4): e20180125, 2020.
Artigo em Português, Inglês | MEDLINE | ID: mdl-32490906

RESUMO

OBJECTIVE: To analyze the complications related to flexible bronchoscopy (FB) and its collection procedures in outpatients and inpatients with various lung and airway diseases treated at a university hospital. METHODS: This was a retrospective analysis of complications occurring during or within 2 h after FB performed between January of 2012 and December of 2013, as recorded in the database of the respiratory endoscopy department of a hospital complex in the city of São Paulo, Brazil. RESULTS: We analyzed 3,473 FBs. Complications occurred in 185 procedures (5.3%): moderate to severe bleeding, in 2.2%; pneumothorax, in 0.7%; severe bronchospasm, in 0.8%; general complications (hypoxemia, psychomotor agitation, arrhythmias, vomiting, or hypotension), in 1.6%; and cardiopulmonary arrest, in 0.03%. There were no deaths related to the procedures. Specifically, among the 1,728 patients undergoing biopsy, bronchial brushing, or fine-needle aspiration biopsy, bleeding occurred in 75 (4.3%). Among the 1,191 patients undergoing transbronchial biopsy, severe pneumothorax (requiring chest tube drainage) occurred in 24 (2.0%). CONCLUSIONS: In our patient sample, FB proved to be a safe method with a low rate of complications. Appropriate continuing training of specialist doctors and nursing staff, as well as the development of standardized care protocols, are important for maintaining those standards.


Assuntos
Broncoscopia , Pulmão , Adulto , Idoso , Brasil/epidemiologia , Broncoscopia/efeitos adversos , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
13.
Ann Transl Med ; 6(11): 210, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30023373

RESUMO

Benign tracheoesophageal fistula (TEF) results from an abnormal communication between the posterior wall of the trachea or bronchi and the adjacent anterior wall of the esophagus. It can be acquired or congenital. The onset of the TEF has a negative impact on the patient's health status and quality of life because of swallowing difficulties, recurrent aspiration pneumonia, and severe weight loss. Several acquired conditions may cause TEF. The most frequent is prolonged orotracheal intubation (75% of the cases). Usually, there is an erosion of the tracheal and esophageal wall by the continuous pressure between the endotracheal tube and the esophageal wall; particularly in the presence of a nasogastric or feeding tube within the esophageal lumen. Furthermore, tracheal stenosis is often associated, and adds complexity to the disease. Preparation for the surgical procedure may take weeks or even months. It includes definitive weaning from mechanical ventilation, treatment of respiratory infection, physiotherapy, and correction of malnutrition through enteral feeding. Surgical repair of a TEF is an elective procedure. It consists of division of the fistula, suture of the esophagus and trachea and protection of the suture lines with a buttressed muscle flap. TEF repair is a complex and challenging procedure, thus, high morbidity and mortality are expected. Nonetheless, surgical management yields excellent long-term results, and it should be considered the first-line treatment for this condition. Definitive fistula closure occurs in about 90-95% of the cases.

14.
Thorac Surg Clin ; 28(2): 227-241, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29627057

RESUMO

Tracheal resections are major surgical procedures with a complication rate as high as 44%. Early detection of complications followed by a structured and expedited course of action is critical for achieving a successful outcome. The prevention of complications after tracheal resection starts with a correct indication for resection. A thorough preoperative evaluation, meticulous surgical technique, and good postoperative care in a center that performs airway surgery routinely are important factors for achieving good results.


Assuntos
Traqueia/cirurgia , Estenose Traqueal/cirurgia , Traqueotomia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/terapia , Cuidados Pré-Operatórios , Doenças da Traqueia/complicações , Doenças da Traqueia/cirurgia , Estenose Traqueal/complicações , Resultado do Tratamento
15.
J Thorac Dis ; 10(8): 4782-4788, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30233850

RESUMO

BACKGROUND: The primary objective of the study was to evaluate the health-related quality of life (HRQL) of patients with benign post-intubation tracheal stenosis considered as unfit for surgical treatment. Secondary objectives were: (I) to determine if clinical variables (gender, age, total treatment time, and type of tracheal device) could influence HRQL and (II) to compare the results with a normal standardized population. METHODS: Prospective study between August-2014 and December-2016 including patients with tracheal stenosis treated with silicone stents, T-Tubes or tracheostomy. Candidates to airway resection and reconstruction were excluded from the analysis. HRQL was assessed with the SF-36 Health Questionnaire. Backward stepwise regression model analyzed the influence of clinical variables on the SF-36 domains and component summaries. Norm-based results were compared with normative data. Alpha error was 5%. RESULTS: Ninety-three patients (62M/31F; mean age 38±14 years) were included. Mean overall HRQL in all 8 SF-36 domains was poor. Lowest scores were in the role physical (mean 31.7±38), bodily pain (mean 39.2±35), and role emotional domain (mean 48.7±40). The physical component summary (PCS) was more affected than the mental (P<0.001). Norm-based results indicated that most domains and both physical and mental summaries were below the mean for the USA normative population. Total stenting time significantly influenced the physical (P=0.001) and mental component summaries (P=0.001). CONCLUSIONS: Quality of life of patients with benign tracheal stenosis is severely impaired, and norm-based results indicate that the HRQL is below normative data. Physical and mental discomfort seems to be attenuated by total treatment time.

16.
Clinics ; 77: 100071, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1394297

RESUMO

Abstract Objective: To investigate the clinical and swallowing indicators related to a successful decannulation process during the hospital stay. Methods: A retrospective cohort clinical study. The study sample comprised a heterogeneous patient population who had submitted to a tracheostomy procedure in a tertiary hospital. Patients were divided into two groups (dec-annulated vs. non-decannulated) and compared not only in terms of demographic and clinical data but also the results of a swallowing assessment and intervention outcome. Results: Sixty-four patients were included in the present study: 25 (39%) who had been successfully decannulated, and 39 (61%) who could not be decannulated. Between-group comparisons indicated that both groups presented similar clinical and demographic characteristics. The groups also presented similar swallowing assessment results prior to intervention. However, significant differences were observed regarding the time to begin swallowing rehabilitation. The decannulated group was assessed nine days earlier than the non-decannulated group. Other significant differences included the removal of the alternate feeding method (72.0% of decannulated patients vs. 5.1% of non-decannulated patients) and the reintroduction of oral feeding (96.0% of decannulated patients vs. 41.0% of non-decannulated patients) and functional swallowing level at patient disclosure. The non-decannulated patient group presented higher death rates at disclosure. Conclusion: The results of the present study indicated that the following parameters were associated with a successful decannulation process: early swallowing assessment, swallowing rehabilitation, and improvement in the swallowing functional level during the hospital stay. The maintenance of low swallowing functional levels was found to be negatively associated with successful decannulation. HIGHLIGHTS Deccanulation indicators were investigated in patients who were submitted to a tracheostomy procedure. Early swallowing evaluation and rehabilitation were associated with a successful decannulation process. Low swallowing functional levels were negatively associated with the success of decannulation.

17.
J Bras Pneumol ; 42(4): 248-253, 2016.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27832231

RESUMO

OBJECTIVE:: Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. METHODS:: We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy), we used fluoroscopy. RESULTS:: Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ± 0.7 cm) and 19 masses (mean diameter, 4.1 ± 0.9 cm). The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS). Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7%) and bronchial bleeding, which was controlled bronchoscopically (in 9.3%). CONCLUSIONS:: Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions. OBJETIVO:: A broncoscopia convencional possui baixo rendimento diagnóstico para lesões pulmonares periféricas. A ecobroncoscopia radial (EBUS radial) emprega um transdutor ultrassonográfico rotatório na extremidade de uma sonda que é inserida no canal de trabalho do broncoscópio. O EBUS radial facilita a localização de nódulos pulmonares periféricos, aumentando assim o rendimento diagnóstico. O objetivo deste estudo foi apresentar nossa experiência inicial com o uso de EBUS radial para o diagnóstico de lesões pulmonares periféricas em um hospital terciário. MÉTODOS:: Foi realizada uma análise retrospectiva de 54 pacientes submetidos à broncoscopia guiada por EBUS radial para a investigação de nódulos ou massas pulmonares entre fevereiro de 2012 e setembro de 2013. O EBUS radial foi realizado com uma sonda flexível de 20 MHz, que foi inserida no canal de trabalho do broncoscópio até chegar à lesão-alvo. A fluoroscopia foi usada para localizar a lesão e realizar procedimentos de coleta (escovado brônquico, aspiração transbrônquica com agulha e biópsia transbrônquica). RESULTADOS:: O EBUS radial identificou 39 nódulos (média de diâmetro: 1,9 ± 0,7 cm) e 19 massas (média de diâmetro: 4,1 ± 0,9 cm). A sensibilidade global do EBUS radial foi de 66,7% (79,5% para as lesões visíveis pelo método e 25% para as lesões não visíveis pelo método). Nas lesões visíveis pelo método, a sensibilidade foi de 91,7% para massas e de 74,1% para nódulos. As complicações foram pneumotórax (3,7%) e sangramento brônquico controlado broncoscopicamente (9,3%). CONCLUSÕES:: O EBUS radial apresenta bom perfil de segurança, baixo índice de complicações e alta sensibilidade para o diagnóstico de lesões pulmonares periféricas.


Assuntos
Broncoscopia/métodos , Endossonografia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncoscopia/instrumentação , Estudos Transversais , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/instrumentação , Feminino , Fluoroscopia/métodos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
20.
J Bras Pneumol ; 41(1): 23-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25750671

RESUMO

OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. METHODS: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. RESULTS: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. CONCLUSIONS: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.


OBJETIVO: A endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA, punção aspirativa por agulha guiada por ultrassom endobrônquico) é um método seguro e preciso para a coleta de amostras de linfonodos mediastinais e hilares. O presente estudo teve por objetivo avaliar os resultados iniciais com EBUS-TBNA para o estadiamento linfonodal de câncer de pulmão em 3 hospitais acadêmicos no Brasil. MÉTODOS: Análise retrospectiva de pacientes com neoplasia de pulmão diagnosticada e submetidos a EBUS-TBNA para estadiamento linfonodal mediastinal. Todos os procedimentos foram realizados sob anestesia geral. Utilizou-se um ecobroncoscópio, uma processadora de ultrassom e agulhas 22 G descartáveis e compatíveis com o ecobroncoscópio. RESULTADOS: Entre janeiro de 2011 e janeiro de 2014, 149 pacientes foram submetidos ao estadiamento linfonodal com EBUS-TBNA. A média de idade foi 66 ± 12 anos, sendo 58% do sexo masculino. Um total de 407 linfonodos foram puncionados via EBUS-TBNA. Os tipos mais comuns de neoplasia brônquica foram adenocarcinoma (em 67%) e carcinoma escamoso (em 24%). Para o estadiamento da neoplasia, o EBUS-TBNA apresentou sensibilidade de 96%, especificidade de 100% e valor preditivo negativo de 85%. CONCLUSÕES: A EBUS-TBNA mostrou-se um método seguro e acurado no estadiamento linfonodal em pacientes com câncer de pulmão.


Assuntos
Biópsia por Agulha Fina/métodos , Broncoscopia/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Neoplasias Pulmonares/patologia , Linfonodos/patologia , Idoso , Brasil , Estudos Transversais , Feminino , Humanos , Masculino , Estadiamento de Neoplasias , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA