Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Neurosci Methods ; 367: 109424, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34826504

RESUMO

BACKGROUND: Electrophysiological resting state functional connectivity using high density electroencephalography (hdEEG) is gaining momentum. The increased resolution offered by hdEEG, usually either 128 or 256 channels, permits source localization of EEG signals on the cortical surface. However, the number of methodological options for the acquisition and analysis of resting state hdEEG is extremely large. These include acquisition duration, eyes open/closed, channel density, source localization methods, and functional connectivity metric. NEW METHODS: We undertake an extensive examination of the test-retest reliability and methodological agreement of all these options for regional measures of functional connectivity. RESULTS: Power envelope connectivity shows larger test-retest reliability than imaginary coherence across all bands. While channel density doesn't strongly impact reliability or agreement, source localization methods produce systematically different functional connectivity, highlighting an important obstacle for replicating results in the literature. Most importantly, reliability and agreement often plateaus at or after 6 minutes of acquisition, well beyond the typical duration of 3 minutes. Finally, our study demonstrates that resting EEG can be as or more reliable than resting fMRI acquired in the same individuals. CONCLUSIONS: The competitive reliability and agreement of power envelope connectivity greatly increases our confidence in measuring resting state connectivity using EEG and its capacity to find individual differences.


Assuntos
Eletroencefalografia , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Fenômenos Eletrofisiológicos , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Descanso
2.
Nat Biotechnol ; 38(4): 439-447, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32042166

RESUMO

Antidepressants are widely prescribed, but their efficacy relative to placebo is modest, in part because the clinical diagnosis of major depression encompasses biologically heterogeneous conditions. Here, we sought to identify a neurobiological signature of response to antidepressant treatment as compared to placebo. We designed a latent-space machine-learning algorithm tailored for resting-state electroencephalography (EEG) and applied it to data from the largest imaging-coupled, placebo-controlled antidepressant study (n = 309). Symptom improvement was robustly predicted in a manner both specific for the antidepressant sertraline (versus placebo) and generalizable across different study sites and EEG equipment. This sertraline-predictive EEG signature generalized to two depression samples, wherein it reflected general antidepressant medication responsivity and related differentially to a repetitive transcranial magnetic stimulation treatment outcome. Furthermore, we found that the sertraline resting-state EEG signature indexed prefrontal neural responsivity, as measured by concurrent transcranial magnetic stimulation and EEG. Our findings advance the neurobiological understanding of antidepressant treatment through an EEG-tailored computational model and provide a clinical avenue for personalized treatment of depression.


Assuntos
Antidepressivos/uso terapêutico , Transtorno Depressivo Maior/tratamento farmacológico , Transtorno Depressivo Maior/fisiopatologia , Eletroencefalografia , Modelos Neurológicos , Transtorno Depressivo Maior/terapia , Método Duplo-Cego , Humanos , Aprendizado de Máquina , Potenciais da Membrana/fisiologia , Valor Preditivo dos Testes , Córtex Pré-Frontal/efeitos dos fármacos , Córtex Pré-Frontal/fisiologia , Reprodutibilidade dos Testes , Sertralina/uso terapêutico , Estimulação Magnética Transcraniana , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA