Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surg Endosc ; 35(10): 5857-5866, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34159463

RESUMO

BACKGROUND: Complications that occur in laparoscopic surgery are often associated with the initial entry into the peritoneal cavity. The literature reported incidences of Veress needle (VN) injuries of e.g. 0.31% and 0.23%. In a 2010 national survey of laparoscopic entry techniques in the Canadian General Surgical practice, 57.3% of respondents had either experienced or witnessed a serious laparoscopic entry complication like bowel perforation and vascular injury. As those complications are potentially life threatening and should be avoided at all costs, improving safety of this initial action is paramount. METHODS: Based on a bare minimum design approach with focus on function expansion of existing components, a new Safety mechanism was developed for the VN that decreases the risks of VN overshooting. The mechanism works by preventing the puncturing acceleration of the tip of the VN by decoupling the surgeon's hand from the VN immediately after entering the abdomen. RESULTS: Based on a set of requirements, a first prototype of the VN+ with force decoupling safety mechanism is presented and evaluated on an ex vivo porcine abdominal wall tissue model in a custom setup. The experiments conducted by two novices and one experienced surgeon indicated a significant difference between the attempts with a standard, conventional working VN (41.4 mm [37.5-45 mm]) and VN+ with decoupling mechanism (20.8 mm [17.5-22.5 mm]) of p < 0.001. CONCLUSION: A new decoupling safety mechanism was integrated successfully in a standard VN resulting in a VN+ . The results from the pilot study indicate that this new VN+ reduces overshooting with a minimum of 50% in a standardised ex vivo setting on fresh porcine abdominal wall specimens.


Assuntos
Parede Abdominal , Laparoscopia , Parede Abdominal/cirurgia , Animais , Canadá , Agulhas , Projetos Piloto , Suínos
2.
Ann Med Surg (Lond) ; 85(5): 1371-1378, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37229054

RESUMO

Veress needles (VN) are commonly used in establishing pneumoperitoneum in laparoscopic surgery. Previously, a VN with a new safety mechanism 'VeressPLUS' needle (VN+) was developed to reduce the amount of overshoot. Methods: Eighteen participants (novices, intermediates, and experts) performed in total of 248 insertions in a systematic way on Thiel-embalmed bodies with wide and small bore versions of the conventional VN (VNc) and the VN+. Insertion depth was measured by recording the graduations on the needle under direct laparoscopic vision. Results: Participants graded the bodies and the procedures as lifelike. Overall, a significant reduction (P<0.001) in average insertion depth was found for the VN+ compared to the VNc of 26.0 SD16 mm versus 46.2 SD15 mm. The insertion depth difference in the novice group was higher compared to the intermediates and experts (P<0.001). The average insertion depth for both needle types was less (P<0.001) for female participants compared to male. Conclusion: This study indicated that the VN+ significantly reduced the insertion depth in all tested conditions. Whether the difference between female and male performance can be linked to differences in muscle control or arm mass should be further investigated. Useful technical information was gathered from this study to further improve the VN+.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA