Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38526773

RESUMO

PURPOSE: This study aimed to investigate the in vitro tolerance to decentration of biaspheric intraocular lens (IOLs) with refractive phase-ring extended depth-of-focus (EDOF) and diffractive trifocal designs. METHODS: This experimental study was carried out at the Department of Optics and Optometry and Vision Science, University of Valencia, Spain. The modulation transfer function (MTF) of the ETLIO130C EDOF and the TFLIO130C trifocal IOLs (AST Products Inc., Billerica, MA, USA) were determined at different levels of decentration for a given wavelength and pupil diameter using the PMTF optical bench (Lambda-X Ophthalmics, Nivelles, Belgium). The modulation transfer function (MTF) curves, the through-focus MTF curves, and the Strehl ratios were measured at 3-mm pupil aperture for 0.25-, 0.50- and 0.75-mm decentration. RESULTS: The optical design of the trifocal TFLIO130C IOL is robust to small decentrations, with virtually no change in MTF response for 0.25 mm decentration. For greater decentration levels, the MTF response is slightly reduced with increasing decentration. The ETLIO130C EDOF design is robust to decentration, as the MTF response is only minimally affected when increasing the decentration up to 0.75 mm. CONCLUSIONS: MTF responses are slightly reduced with greater levels of decentration, but the range of focus provided by both trifocal and EDOF designs are preserved. The effects for average levels of decentration reported in the literature are minimum for both IOL designs.

2.
Ophthalmic Physiol Opt ; 43(4): 885-897, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37073817

RESUMO

PURPOSE: To assess changes in visual function and optical and tear film quality in computer users. METHODS: Forty computer workers and 40 controls were evaluated at the beginning and end of a working day. Symptoms were assessed using the Quality of Vision questionnaire (QoV), 5-item Dry Eye Questionnaire (DEQ-5) and Symptom Assessment in Dry Eye version II (SANDE II). Tear film quality was evaluated using the Medmont E300 dynamic corneal topography tool to measure the tear film surface quality (TFSQ), TFSQ area and auto tear break-up time (TBUT). Optical quality was assessed by measuring high, low and total ocular aberrations with a Hartmann-Shack wavefront sensor. Visual performance was assessed by measuring photopic and mesopic visual acuity, photopic and mesopic contrast sensitivity and light disturbance. RESULTS: Poorer DEQ-5, QoV and SANDE II scores were obtained in computer workers at the end of the working day compared with controls (p ≤ 0.02). Computer workers exhibited a higher (worse) TFSQ and TFSQ area at visit 2 compared with visit 1 (p ≤ 0.04), while no significant differences in TBUT (p = 0.19) or ocular aberrations were observed (p ≥ 0.09). Additionally, both light disturbance (p ≤ 0.04) and mesopic and photopic contrast sensitivity worsened at several spatial frequencies (p ≤ 0.04) throughout the working day in computer workers, while visual acuity remained unchanged (p ≥ 0.07). In contrast, control subjects exhibited no decrease in any variable during the day. CONCLUSIONS: While visual acuity remained unchanged, several aspects of visual function and quality of vision decreased over a day of computer use. These changes were accompanied by greater dry eye symptoms and tear film changes, which are likely to have played a fundamental role. The present study provides insight into new metrics to assess digital eye strain.


Assuntos
Síndromes do Olho Seco , Visão Ocular , Humanos , Lágrimas , Acuidade Visual , Topografia da Córnea , Síndromes do Olho Seco/diagnóstico
3.
Graefes Arch Clin Exp Ophthalmol ; 260(2): 655-676, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34487223

RESUMO

PURPOSE: This study aimed to develop and validate new metrics to objectively assess the lipid layer thickness (LLT) through the analysis of grey intensity values obtained from the Placido disk pattern reflected onto the tear film. METHODS: Ocular surface parameters were measured using Oculus Keratograph 5 M in 94 healthy volunteers (43.8 ± 26.8 years). Subjects' LLT was subjectively classified into 4 groups using an interferometry-based grading scale. New metrics based on the intensity of the Placido disk images were calculated and compared between groups. The repeatability of the new metrics and their diagnostic ability was analysed through receiver operating characteristics (ROC) curves. The level of agreement between the new objective tool and the existing subjective classification scale was analysed by means accuracy, weighted Kappa index and F-measure. RESULTS: Mean pixel intensity, median pixel intensity and relative energy at 5.33 s after blinking achieved the highest performance, with a correlation with LLT between r = 0.655 and 0.674 (p < 0.001), sensitivity between 0.92 and 0.94, specificity between 0.79 and 0.81, area under the ROC curve between 0.89 and 0.91, accuracy between 0.76 and 0.77, weighted Kappa index of 0.77 and F-measure between 0.86 and 0.87. CONCLUSION: The analysis of grey intensity values in videokeratography can be used as an objective tool to assess LLT. These new metrics could be included in a battery of clinical tests as an easy, repeatable, objective and accessible method to improve the detection and monitoring of dry eye disease and meibomian gland dysfunction.


Assuntos
Síndromes do Olho Seco , Disfunção da Glândula Tarsal , Síndromes do Olho Seco/diagnóstico , Humanos , Lipídeos , Glândulas Tarsais , Lágrimas
4.
BMC Ophthalmol ; 22(1): 240, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35642049

RESUMO

PURPOSE: To assess the depth of field (DOF) by means of defocus curve analysis applying different visual acuity criteria in patients following cataract surgery and bilateral implantation of a new trifocal diffractive intraocular lens (IOL). METHODS: Fifty eyes of 25 consecutive patients who underwent implantation of the Asqelio™ trifocal IOL (AST Products Inc., USA) were enrolled in this observational prospective study. Monocular subjective DOF was obtained from defocus curves with absolute and relative criteria of tolerance for different visual acuities values. Patient's visual satisfaction, postoperative refraction and visual acuity at far, intermediate (67 cm) and near (40 cm) distances were also measured at 1 and 3-months post-surgery. Analysis of variance was used to assess differences in refractive error after the surgical procedure, and paired t-tests were used to assess differences in VA. Patient satisfaction results were reported as percentages. RESULTS: Spherical equivalent was 0.05 ± 0.23 D and residual cylinder 0.01 ± 0.23 D 3-months after the surgery. Absolute DOF obtained was 3.29 ± 0.91 D considering 0.1 LogMAR as cut-off value, and 4.82 ± 0.69 D when 0.3 logMAR as cutoff value. Relative DOF considering a drop of 0.1 logMAR from maximum visual acuity was 2.57 ± 0.82 D, and 1.27 ± 0.70 D when a drop of 0.04 logMAR was considered. Visual acuities obtained 3-months after the surgery were 0.03 ± 0.13, - 0.05 ± 0.06, 0.03 ± 0.08 and 0.04 ± 0.08 logMAR for uncorrected and best-corrected for distance, and best distance-corrected for intermediate and near distances, respectively. Average response to visual satisfaction queries was 8.24/10 at distance, 8.04/10 at intermediate, and 7.88/10 at near. CONCLUSIONS: Patients implanted with this trifocal IOL showed a significant improvement in visual acuity at different distances providing wide absolute and relative DOF values. The outcomes demonstrate that this lens is predictable yielding good patient satisfaction rates.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Desenho de Prótese , Refração Ocular
5.
Ophthalmic Physiol Opt ; 42(4): 797-806, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35394083

RESUMO

PURPOSE: To assess the potential additive effects of short-term display use and contact lens (CL) wear on the ocular surface and tear film. METHODS: Thirty-four healthy volunteers (20.87 ± 2.33 years old) participated in this study. Participants' dry eye symptoms, ocular surface, tear film and pupil size were assessed before and after executing a 20-min reading task on a computer and a smartphone with and without CL wear, or with CL wear and artificial tear instillation. Measurements included the Ocular Surface Disease Index (OSDI) questionnaire; 5-item Dry Eye Questionnaire (DEQ-5); tear meniscus height (TMH); noninvasive keratograph break-up time (NIKBUT); bulbar conjunctival redness (BR) and pupil size. RESULTS: Higher symptoms were reported after reading on both displays with and without CLs (p ≤ 0.001) for short periods. BR was higher and NIKBUT shorter after reading on the computer regardless of wearing CLs (p ≤ 0.02 and p ≤ 0.02, respectively), while TMH increased for all conditions (p ≤ 0.02) except for CL computer reading (p = 0.23). Reading with CLs did not lead to greater signs of dry eye (BR, NIKBUT) and symptoms compared with reading unaided (p > 0.05), although a smaller increase in TMH was observed when reading on the computer with CLs (p = 0.005). Artificial tear instillation during CL wear led to a smaller increase in symptoms (p ≤ 0.02), a smaller increase in BR (p ≤ 0.04) and a decrease in NIKBUT (p = 0.02) compared to reading without correction. CONCLUSIONS: Disposable CL wear had no additive effects on signs and symptoms of dry eye when using digital devices for short periods. The instillation of artificial tears is an effective strategy for reducing the impact of display use in CL wearers.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Adolescente , Adulto , Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Olho , Humanos , Lubrificantes Oftálmicos , Lágrimas , Adulto Jovem
6.
Ophthalmic Physiol Opt ; 42(5): 1062-1073, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35801815

RESUMO

PURPOSE: To assess and compare short-term visual and optical quality and tear film stability between two dual-focus (DF) prototype myopia control contact lenses (CLs) having different inner zone diameters. METHODS: Twenty-eight myopic subjects were included in this randomised, double-masked crossover study. Refraction, best-corrected visual acuity (VA) and tear film stability were measured at baseline (i.e., when uncorrected). Subjects were then binocularly fitted with the DF CLs, with only the sensorial dominant eye being assessed. Lenses were of the same material and had inner zone diameters of either 2.1 mm (S design) or 4.0 mm (M design). Visual and physical short-term lens comfort, over-refraction, best-corrected VA, stereopsis at 40 cm, best-corrected photopic and mesopic contrast sensitivity (CS), size and shape of light disturbance (LD), wavefront aberrations, subjective quality of vision (QoV Questionnaire) and tear film stability were measured for each lens. RESULTS: Both CL designs decreased tear film stability compared with baseline (p < 0.05). VA and photopic CS were within normal values for the subjects' age with each CL. When comparing lenses, the M design promoted better photopic CS for the 18 cycles per degree spatial frequency (p < 0.001) and better LD (p < 0.02). However, higher-order aberrations were improved with the S design (p = 0.02). No significant difference between the two CLs was found for QoV scores and tear film stability. CONCLUSIONS: Both DF CLs provided acceptable visual performance under photopic conditions. The 4.0 mm inner zone gave better contrast sensitivity at high frequencies and lower light disturbance, while the 2.1 mm central diameter induced fewer higher-order aberrations for a 5 mm pupil diameter. Both CLs produced the same subjective visual short-term lens comfort.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Miopia , Sensibilidades de Contraste , Estudos Cross-Over , Humanos , Miopia/terapia , Refração Ocular , Acuidade Visual
7.
Eye Contact Lens ; 48(10): 410-415, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36155946

RESUMO

OBJECTIVES: To evaluate dry eye-related lifestyle and demographic factors associated with digital eye strain (DES). METHODS: An anonymous online survey was conducted in 851 university students. Participants were classified into DES (computer vision syndrome questionnaire [CVS-Q]≥6) or non-DES (CVS-Q<6). Respondents completed three dry eye questionnaires (Ocular Surface Disease Index [OSDI]; 5-item Dry Eye Questionnaire [DEQ-5]; 8-item Contact Lens Dry Eye Questionnaire) and were surveyed on dry eye risk factors contemplated by the Tear Film and Ocular Surface Society Dry Eye Workshop II. RESULTS: Six hundred twenty-eight participants were classified into the group with DES and 222 into the group without DES. Participants with DES slept fewer hours, spent more hours indoors with air conditioning, drank more caffeinated beverages, used the computer for longer periods, reported poorer health quality, and obtained a higher score in all questionnaires (P<0.025). A higher proportion of the participants were female, had several health disorders, and took several medications associated with dry eye (P<0.029). Multivariate logistic regression analysis revealed that stress (P=0.035), contact lens wear (P=0.011), hours of computer use per day (P=0.010), migraine headaches (P=0.013), and a higher OSDI (P<0.001) and DEQ-5 score (P<0.001) were associated with DES. CONCLUSIONS: Several dry eye-related risk factors and health conditions are associated with suffering from DES. Clinicians should acknowledge the relevance of triaging questions and dry eye disease risk factors when dealing with patients who view screens for extended periods.


Assuntos
Síndromes do Olho Seco , Estudos Transversais , Síndromes do Olho Seco/epidemiologia , Síndromes do Olho Seco/etiologia , Feminino , Humanos , Masculino , Fatores de Risco , Inquéritos e Questionários , Lágrimas
8.
Eye Contact Lens ; 48(10): 416-423, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36155947

RESUMO

OBJECTIVES: To assess and compare the effectiveness of four main management strategies for preventing short-term effects of digital display use on dry eye signs and symptoms. METHODS: The ocular surface, tear film, and visual fatigue of 47 healthy individuals were assessed before and after reading on a laptop computer for 20 min under five different experimental conditions: control, instillation of artificial tears, taking a brief break, using a blue light screen filter, and blink control. Measurements included the Ocular Surface Disease Index (OSDI) Questionnaire, 5-item Dry Eye Questionnaire (DEQ-5), tear meniscus height (TMH), noninvasive keratograph break-up time (NIKBUT), bulbar conjunctival redness, and pupil size. RESULTS: Worse results were obtained after the control and blue light filter conditions in all variables (P≤0.037). A higher post-task DEQ-5 score (P=0.013) and TMH (P<0.0005) were obtained when taking a brief break compared with pretask, although the increase in symptoms was significantly smaller than that observed in the nonmanagement control condition (P≤0.036). Similarly, a smaller increase in OSDI and DEQ-5 was obtained with the use of artificial tears and blink control in comparison with the control condition (P≤0.008), whereas a greater increase in DEQ-5 and decrease in NIKBUT was obtained for the blue light filter condition in comparison with the instillation of artificial tears (P=0.017) or blink control (P=0.008), respectively. Finally, a significantly lower post-task pupil size was obtained for all the conditions (P≤0.027). CONCLUSIONS: The instillation of artificial tears and blink control were the best management strategies for preventing short-term effects of digital display use on dry eyes. Conversely, using a blue light filter did not offer any benefits.


Assuntos
Síndromes do Olho Seco , Ceratoconjuntivite Seca , Piscadela , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/prevenção & controle , Humanos , Lubrificantes Oftálmicos , Lágrimas
9.
Graefes Arch Clin Exp Ophthalmol ; 259(5): 1323-1331, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33409681

RESUMO

PURPOSE: The aim of this study is to develop a new objective semiautomatic method for analysing Meibomian glands visibility quantitatively. METHODS: One hundred twelve healthy volunteers aged between 18 and 90 years (48.29 ± 27.46 years) participated in this study. Infrared meibography was obtained from the right upper eyelid through Oculus Keratograph 5 M. Meibographies were classified into 3 groups: Group 1 = patients with good subjective glands visibility and a gland dropout percentage < 1/3 of the total Meibomian gland area; Group 2 = patients with low subjective glands visibility and a gland dropout < 1/3; and Group 3 = patients with low subjective glands visibility and a gland dropout > 1/3. New metrics based on the visibility of the Meibomian glands were calculated and later compared between groups. Rho Spearman test was used to assess the correlation between each metric, and Meibomian gland dropout percentage with the entire sample and after excluding Group 2. A p value less than 0.05 was defined as statistically significant. RESULTS: Fifty-six subjects were classified in Group 1 (24.48 ± 9.62 years), 19 in Group 2 (69.16 ± 21.30 years) and 37 in Group 3 (73.59 ± 13.70 years). No statistically significant differences were found between Groups 1 and 2 in dropout percentage. All metrics, with the exception of entropy, showed a higher Meibomian gland visibility in Group 1 than in the other two groups. Moderate correlations were statistically significant for all metrics with the exception of entropy. Correlations were higher after excluding Group 2. CONCLUSION: The proposed method is able to assess Meibomian gland visibility in an objective and repeatable way, which might help clinicians enhance Meibomian gland dysfunction diagnosis and follow-up treatment.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Pessoa de Meia-Idade , Projetos de Pesquisa , Lágrimas , Adulto Jovem
10.
Optom Vis Sci ; 98(9): 1045-1055, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34459466

RESUMO

SIGNIFICANCE: The diagnosis of dry eye disease and meibomian gland dysfunction (MGD) is challenging. Measuring meibomian gland visibility may provide an additional objective method to diagnose MGD. PURPOSE: This study aimed to evaluate the ability of new metrics to better diagnose MGD, based on measuring meibomian gland visibility. METHODS: One hundred twelve healthy volunteers (age, 48.3 ± 27.5 years) were enrolled in this study. Ocular surface parameters were measured using the Oculus Keratograph 5M (Oculus GmbH, Wetzlar). Subjects were classified according to the presence or absence of MGD. New metrics based on the visibility of the meibomian glands were calculated and later compared between groups. The diagnostic ability of ocular surface parameters and gland visibility metrics was studied through receiver operating characteristic curves. Logistic regression was used to obtain the combined receiver operating characteristic curve of the metrics with the best diagnostic ability. RESULTS: Statistically significant differences were found between groups for all ocular surface parameters and new gland visibility metrics, except for the first noninvasive keratograph breakup time and gland expressibility. New gland visibility metrics showed higher sensitivity and specificity than did current single metrics when their diagnostic ability was assessed without any combination. The diagnostic capability increased when gland visibility metrics were incorporated into the logistic regression analysis together with gland dropout percentage, tear meniscus height, dry eye symptoms, and lid margin abnormality score (P < .001). The combination of median pixel intensity of meibography gray values and the aforementioned ocular surface metrics achieved the highest area under the curve (0.99), along with excellent sensitivity (1.00) and specificity (0.93). CONCLUSIONS: New meibomian gland visibility metrics are more powerful to diagnose MGD than current single metrics and can serve as a complementary tool for supporting the diagnosis of MGD.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Disfunção da Glândula Tarsal , Adulto , Idoso , Síndromes do Olho Seco/diagnóstico por imagem , Doenças Palpebrais/diagnóstico por imagem , Humanos , Glândulas Tarsais/diagnóstico por imagem , Pessoa de Meia-Idade , Lágrimas , Adulto Jovem
11.
Eye Contact Lens ; 47(10): 565-572, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34224445

RESUMO

OBJECTIVES: To assess the potential effects of switching to online lecture format on dry eye symptoms and dry eye disease (DED) risk factors. METHODS: An anonymous cross-sectional online survey was conducted in 812 university students (mean age, 21.5±4.0 years). Participants were classified according to the number of hours the participants took online lectures into online students or in-person students. Respondents completed a total of three DED questionnaires (Ocular Surface Disease Index [OSDI]; 5-item Dry Eye Questionnaire; 8-item Contact Lens Dry Eye Questionnaire) and were surveyed on dry eye risk factors contemplated by the Tear Film and Ocular Surface Society Dry Eye Workshop II in addition to other factors potentially linked to dry eye. RESULTS: Five hundred twenty-three subjects (64.4%) were classified into the online group and 289 (35.6%) into the in-person group. No statistically significant age (P=0.266) or sex (P=0.423) differences were found between groups. Students taking online lectures used the computer more, spent less time outdoors, practised more exercise, wore a face mask for less time, experienced fewer allergies and fewer psoriasis episodes, and obtained a higher OSDI score (P<0.029 for all). Multivariate logistic regression analysis revealed that the hours of online lectures taken per week was independently associated with having a positive OSDI score (P=0.022). CONCLUSIONS: Taking online lectures is independently associated with having dry eye symptoms. Despite a lower prevalence of DED risk factors, a higher computer use is probably behind the greater ocular dryness reported by online students.


Assuntos
COVID-19 , Síndromes do Olho Seco , Adolescente , Adulto , Estudos Transversais , Síndromes do Olho Seco/epidemiologia , Humanos , Pandemias , Fatores de Risco , SARS-CoV-2 , Inquéritos e Questionários , Lágrimas , Adulto Jovem
12.
Int Ophthalmol ; 41(7): 2473-2483, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33728492

RESUMO

PURPOSE: The aim of this study is to assess the intraexaminer repeatability of Non-invasive Keratograph Break-Up Time (NIKBUT) obtained using the Oculus Keratograph 5M (K5M), given its relevance as a homeostasis marker in Dry Eye Disease (DED). METHODS: In total, 80 healthy volunteers aged between 30 and 89 years participated. Measurements were classified according to age, sex and the presence or not of DED. Repeatability was evaluated by the calculation of within-subject standard deviation (Sw), coefficient of repeatability (CoR) and coefficient of variation (CoV). Moreover, the Passing-Bablok regression method was applied. RESULTS: Sw, CoR and CoV coefficients showed low repeatability in all groups with values between 3.57 and 7.14; 9.90 and 19.79; and 51.90 and 65.49, for each coefficient, respectively. No statistically significant differences were found in the NIKBUT measurements between healthy and DED patients (p = 0.188). Groups with more DED risk had better repeatability. Passing-Bablok regression also confirmed a lack of agreement between the maximum and minimum NIKBUT measurement. CONCLUSION: NIKBUT measurement has low intraexaminer repeatability even when considering sex, age and DED diagnosis. Nevertheless, not only is this low repeatability due to the device, but also it is largely due to the intrinsic variability of the tear film.


Assuntos
Síndromes do Olho Seco , Lágrimas , Adulto , Idoso , Idoso de 80 Anos ou mais , Síndromes do Olho Seco/diagnóstico , Voluntários Saudáveis , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Optom Vis Sci ; 97(3): 178-185, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32168240

RESUMO

SIGNIFICANCE: Tear osmolarity has been reported as one of the best diagnostic tests for dry eye disease and its management. Contact lens wear is thought to influence tear homeostasis. Understanding how regular wear of contact lenses and their type affect tear osmolarity is important. PURPOSE: The purpose of this study was to assess changes in tear osmolarity and ocular symptoms over a period of 12 months following refitting contact lens wearers with daily disposable contact lenses. METHODS: Fifty subjects aged (mean ± SD) 26 ± 4 years were refitted with either silicone-hydrogel (delefilcon A, SiHy, n = 34) or hydrogel (omafilcon A, Hy, n = 16) daily disposable soft contact lenses. Study included seven visits: baseline measurements without contact lenses; two visits for contact lens fit and selection; follow-up measurements after 3, 6, and 12 months of contact lens wear; and a post-study visit without contact lenses. Lens type selection was based on a set of objective measurements. Subjects were instructed to follow strict wearing rules. Impedance-based osmometer was used to collect samples from the lower tear meniscuses. The Ocular Surface Disease Index (OSDI) and the eight-item Contact Lens Dry Eye Questionnaire were used to assess subject-reported ocular symptoms and contact lens discomfort, respectively. RESULTS: Downward trend of tear osmolarity was noted over the time course of study. Statistically significant differences were noted in tear osmolarity (Friedman test, χ = 21.91 [P < .001], and χ = 13.89 [P = .003]) for the right and left eyes, respectively. A statistically significant decrease in tear osmolarity was apparent only for initially symptomatic subjects (for OSDI ≥13: χ = 26.25, P < .001; for OSDI <13: χ = 5.65, P = .13). Statistically significant differences were not noted in OSDI and the eight-item Contact Lens Dry Eye Questionnaire between the baseline and 12-month visit (χ = 5.92 [P = .12] and R = 0.015 [P = .87], respectively). There was a difference between baseline and post-study visits (P = .002) in OSDI, showing lower score at the latter visit. CONCLUSIONS: Refitting with daily disposable contact lenses was demonstrated to lower tear osmolarity.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco/terapia , Concentração Osmolar , Lágrimas/química , Adulto , Equipamentos Descartáveis , Feminino , Humanos , Hidrogéis , Masculino , Estudos Prospectivos , Ajuste de Prótese , Inquéritos e Questionários , Adulto Jovem
14.
Ophthalmic Physiol Opt ; 40(6): 718-727, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32885875

RESUMO

PURPOSE: To compare the optical and visual performance of a dual-focus (DF) contact lens used for myopia control with a single-vision (SV) contact lens of the same material. METHODS: A randomised, double-masked crossover study. Twenty-eight healthy, myopic volunteers between 18 and 32 years of age (23.49 ± 4.07 years) participated in this study. The sensory dominant eye for distance vision was determined. Refraction, best-corrected visual acuity (VA) and aberrations for 3 mm and 5 mm pupil diameters were quantified without a contact lens in situ. Subjects were fitted with two contact lens designs: DF and SV, both made of omafilcon A material. The Quality of Vision (QoV) questionnaire, over-refraction, best-corrected VA, stereopsis at 40 cm, best-corrected photopic and mesopic contrast sensitivity, light disturbance and aberrations were assessed 25 min after contact lens insertion. RESULTS: There were no statistically significant differences in best-corrected VA and stereopsis between the baseline, DF and SV conditions. Photopic and mesopic contrast sensitivity were lower for the DF contact lens at all frequencies, with the exception of the mesopic contrast sensitivity at 18 cycles per degree (p = 0.23). Higher order aberrations and light disturbance size and irregularity were higher for the DF contact lens (p < 0.001). No differences were found in higher order aberrations between baseline and the SV contact lens condition for each pupil diameter. QoV scores also revealed lower frequency, severity and bothersome scores with the SV contact lens than with the DF contact lens (p < 0.001). CONCLUSIONS: The DF contact lens design decreased the psychophysical and psychometric visual quality scores in the short-term under dim-light conditions when compared with a single-vision contact lens design of the same material. VA and stereopsis were unaffected by the lens design.


Assuntos
Visão de Cores/fisiologia , Lentes de Contato Hidrofílicas , Sensibilidades de Contraste/fisiologia , Miopia/fisiopatologia , Acuidade Visual , Adolescente , Adulto , Estudos Cross-Over , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Miopia/terapia , Fatores de Tempo , Adulto Jovem
15.
Eye Contact Lens ; 45(1): 40-45, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29944498

RESUMO

OBJECTIVES: To investigate the ocular surface of an aged population wearing a daily disposable contact lens (CL) over their 1st day of wear. METHODS: Forty eyes from 40 presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA), and ocular surface aberrations (total higher-order root mean square [RMS]) were assessed at baseline (t0), at 20 min (t1) and after 8 hr (t2) of wear. Fluorescein corneal and conjunctival staining and tear breakup time (TBUT) were performed at t0 and t2. RESULTS: No statistically significant changes were found between t0, t1, and t2 for TMA and between t0 and t2 for fluorescein corneal and conjunctival staining. Tear breakup time worsened by the end of the day from 10.4±0.4 sec t0 to 9.0±0.3 sec t2 (P<0.05). Osmolarity showed significant changes between t0 306.9±2.3 mOsm/L and t1 312.4±2.4 mOsmol/L (P=0.02) but returned to baseline values at 8 hr (310.40±2.26 mOsm/L; P=0.09). Total higher-order RMS showed significant changes between t0 0.38±0.02 µm and t1 0.61±0.04 µm (P≤0.001) and between t0 and t2 0.64±0.41 µm (P≤0.001). CONCLUSIONS: Delefilcon A may induce measures changes (osmolarity and TBUT values) in a presbyopic population; however, TMA and vital staining were maintained at the baseline level over the day.


Assuntos
Envelhecimento/fisiologia , Lentes de Contato Hidrofílicas , Equipamentos Descartáveis , Síndromes do Olho Seco/terapia , Satisfação do Paciente , Presbiopia/terapia , Lágrimas/química , Adulto , Túnica Conjuntiva/metabolismo , Córnea/metabolismo , Síndromes do Olho Seco/metabolismo , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Concentração Osmolar , Presbiopia/fisiopatologia , Estudos Prospectivos , Visão Ocular
16.
Graefes Arch Clin Exp Ophthalmol ; 253(4): 645-53, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25418035

RESUMO

PURPOSE: To explore the distribution of total, corneal, and internal higher-order aberrations (HOAs) in both insulin-dependent (IDDM) and non-insulin-dependent (NIDDM) diabetic patients. METHODS: Pilot study including seven patients with IDDM (14 eyes) and 11 patients with NIDDM (22 eyes). Ocular HOAs were examined using ray tracing aberrometry (i-Trace, Tracey Technologies Corp., Houston, TX) and the measurements of anterior segment using Scheimpflug imaging (Pentacam, Oculus Inc. Germany). RESULTS: Total HOAs was slightly higher in IDDM (0.634 ± 0.228 µm, 95% IC ± 0.131) than in NIDDM patients (0.527 ± 0.245 µm, 95% IC ± 0.108) (p = 0.267). The greatest contributor for total ocular HOAs was internal vertical coma (Z3 (- 1)) for both diabetic groups. In NIDDM, age and central corneal thickness (CCT) were correlated with total HOAs (p < 0.001, p = 0.0180 respectively); however, anterior chamber volume (ACV) was inversely correlated with total HOAs (p = 0.019). In IDDM, total HOAs were correlated with posterior asphericity (Q) (p = 0.002) and inversely correlated with ageing (p = 0.013). CONCLUSIONS: Diabetic patients showed high values of total and internal vertical coma (Z3 (- 1)). There might be a role for optical quality measurements in monitoring changes due to DM.


Assuntos
Segmento Anterior do Olho/patologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Aberrometria , Adulto , Idoso , Topografia da Córnea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Refração Ocular/fisiologia
17.
Optom Vis Sci ; 92(1): 89-94, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25360701

RESUMO

PURPOSE: We aimed to analyze the corneal thickness (CT) values of female and male subjects before and after instillation of oxybuprocaine 0.4% anesthetic eye drops. METHODS: The CT of 30 female subjects and 28 male subjects was measured using scanning-slit corneal topography (Orbscan Topography System II, Orbscan, Inc, Salt Lake City, UT). Measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 0.4% eye drops. RESULTS: The difference between the baseline values and those obtained after anesthesia ranged as follows: male subjects: central, -26 to +24 µm; superior, -24 to +23 µm; inferior, -19 to +20 µm; nasal, -25 to +30 µm; and temporal, -21 to +20 µm; female subjects: central, -16 to +24 µm; superior, -19 to +32 µm; inferior, -14 to +34 µm; nasal, -19 to +33 µm; and temporal, -36 to +16 µm. No significant differences were found in any corneal location in male subjects. The differences were significant at inferior (p = 0.001) and nasal (p = 0.011) corneal sites in female subjects. CONCLUSIONS: Oxybuprocaine anesthetic eye drops induce significant CT increases in female subjects but not in male subjects.


Assuntos
Anestésicos Locais/efeitos adversos , Córnea/efeitos dos fármacos , Córnea/patologia , Procaína/análogos & derivados , Adolescente , Adulto , Anestésicos Locais/administração & dosagem , Topografia da Córnea , Feminino , Humanos , Masculino , Soluções Oftálmicas , Tamanho do Órgão/efeitos dos fármacos , Procaína/administração & dosagem , Procaína/efeitos adversos , Estudos Prospectivos , Fatores Sexuais , Adulto Jovem
18.
Ophthalmic Physiol Opt ; 35(3): 293-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25545996

RESUMO

PURPOSE: To evaluate the differences in endothelial cell density (ECD) and central corneal thickness (CCT) between type II diabetic patients and age-matched healthy controls, and determine the impact of time from diagnosis. METHODS: This is a comparative study of 77 eyes of type II diabetic patients (33 males, 44 females) and 80 eyes of healthy subjects (42 males, and 38 females) whose ages ranged from 38 to 56 years. CCT, ECD, HbA(1c) levels, and Goldmann tonometry were measured. RESULTS: The CCT was significantly higher and the ECD significantly lower in long-term diabetic patients (10 years + since diagnosis) when compared with short-term diabetic patients (<1 year since diagnosis) and controls (both p < 0.001). No significant differences in CCT (p = 0.30) and ECD (p = 0.31) were found between control groups. Multivariate analysis of variance indicated that there was a significant effect of the diabetes duration in CCT and ECD. In diabetic patients, a two-way analysis of variance showed that CCT was significantly different for a 7.5% HbA(1c) cut-off value, and ECD for both 7.0% and 7.5% HbA(1c) cut-off values. CONCLUSION: Type II diabetes causes a significant alteration in corneal structure and function in the long term. Our study seems to confirm the effect of diabetes duration and poor glycaemic control on CCT and ECD changes.


Assuntos
Córnea/patologia , Diabetes Mellitus Tipo 2/patologia , Adulto , Contagem de Células , Paquimetria Corneana/métodos , Diabetes Mellitus Tipo 2/sangue , Progressão da Doença , Endotélio Corneano/patologia , Feminino , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
19.
Artigo em Inglês | MEDLINE | ID: mdl-38780434

RESUMO

PURPOSE: To determine the impact of optotype choice on the determination of defocus curve in cataract patients implanted with presbyopia-correcting intraocular lens (IOL). SETTING: Oftalvist Alicante, Alicante, Spain. DESIGN: Observational case-control study. METHODS: Patients implanted with Asqelio Trifocal IOL (AST Products, Inc., Billerica, MA, USA) participated in this study. Uncorrected and distance corrected visual acuity and subjective refraction were determined. Monocular defocus curves were obtained 6 months after surgery with the CTS system using either ETDRS or Landolt C charts under photopic conditions (85 cd/m2), and range of vergence from +2.00D to -5.00D in 0.50D steps. RESULTS: A total of 49 patients were enrolled in the study, 24 in the EDTRS group (7 male, 17 female) and 25 in the Landolt C group (5 male, 20 female). Non-significant differences were found between patients conforming both groups, except for preoperative intraocular pressure and white-to-white distance. All patients were within ±1.00D from intended refraction after surgery. 75% of patients in the EDTRS group and 84% in the Landolt C group were within ±0.50D. Average difference between the groups across vergences provided by the defocus curve was 0.12±0.05 logMAR units, significant for all vergences (p<0.05). Differences in VA were significant for distance, intermediate and near between both groups, except for uncorrected distance VA. CONCLUSION: Defocus curves created using Landolt C charts yield significantly lower through-focus outcomes than those created with standard EDTRS charts. This should be taken into account when comparing the performance of presbyopia-correcting systems accross studies where recognition charts might have been used due to patient characteristics.

20.
Graefes Arch Clin Exp Ophthalmol ; 251(1): 331-40, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22562479

RESUMO

PURPOSE: To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. METHODS: Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. RESULTS: Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = -0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = -0.551, p = 0.04), but not with higher order RMS (r = -0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. CONCLUSIONS: Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.


Assuntos
Implante de Lente Intraocular , Miopia/cirurgia , Óptica e Fotônica , Lentes Intraoculares Fácicas , Qualidade de Vida , Acuidade Visual/fisiologia , Adulto , Sensibilidades de Contraste/fisiologia , Feminino , Seguimentos , Ofuscação , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Refração Ocular/fisiologia , Perfil de Impacto da Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA