1.
Circulation ; 2024 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-39391988

RESUMO

BACKGROUND: Brugada syndrome (BrS) is a cardiac arrhythmia disorder that causes sudden death in young adults. Rare genetic variants in the SCN5A gene encoding the Nav1.5 sodium channel and common noncoding variants at this locus are robustly associated with the condition. BrS is particularly prevalent in Southeast Asia but the underlying ancestry-specific factors remain largely unknown. METHODS: Genome sequencing of BrS probands and population-matched controls from Thailand was performed to identify rare noncoding variants at the SCN5A-SCN10A locus that were enriched in patients with BrS. A likely causal variant was prioritized by computational methods and introduced into human induced pluripotent stem cell (hiPSC) lines using CRISPR-Cas9. The effect of the variant on SCN5A expression and Nav1.5 sodium channel current was then assessed in hiPSC-derived cardiomyocytes (hiPSC-CMs). RESULTS: A rare noncoding variant in an SCN5A intronic enhancer region was highly enriched in patients with BrS (detected in 3.9% of cases with a case-control odds ratio of 45.2). The variant affects a nucleotide conserved across all mammalian species and predicted to disrupt a Mef2 transcription factor binding site. Heterozygous introduction of the enhancer variant in hiPSC-CMs caused significantly reduced SCN5A expression from the variant-containing allele and a 30% reduction in Nav1.5-mediated sodium current density compared with isogenic controls, confirming its pathogenicity. Patients with the variant had severe phenotypes, with 89% experiencing cardiac arrest. CONCLUSIONS: This is the first example of a functionally validated rare noncoding variant at the SCN5A locus and highlights how genome sequencing in understudied populations can identify novel disease mechanisms. The variant partly explains the increased prevalence of BrS in this region and enables the identification of at-risk variant carriers to reduce the burden of sudden cardiac death in Thailand.

2.
J Cardiovasc Electrophysiol ; 35(2): 249-257, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38065836

RESUMO

INTRODUCTION: Cardiac resynchronization therapy (CRT) is a standard treatment for patients with heart failure with reduced ejection fraction. However, there is still a gap of evidence in congenital heart disease (CHD) patients regarding resynchronization therapy. METHODS: We performed a meta-analysis and systematic review of CHD patients who received CRT implantation. We comprehensively searched the databases of MEDLINE, EMBASE, and Cochrane database from inception to June 2023. Studies that reported response rate to CRT, total mortality rate, change in QRS duration, change in left ventricular ejection fraction, and change in New York Heart Association functional class were included. RESULTS: A total of 14 studies were included in the study. There were 10 studies that reported response rates after implantation. The overall response rate to CRT in CHD patients was 68% (95% confidence interval [CI] 61%-75%, I2 32%). The response rates in patients with systemic right ventricle (RV), systemic left ventricle (LV), and single ventricle were 58% (95% CI 46%-70%, I2 0%), 80% (95% CI 74%-86% I2 14%), and 67% (95% CI 49%-80% I2 0%). Response to CRT in systemic RV was inferior to systemic LV with an odds ratio of 0.38 (95% CI 0.15-0.95, I2 38%). The total mortality rate from seven studies was 12% (95% CI 8%-18%, I2 55%). The parameters which represented ventricular dyssynchrony improved after CRT implantation. CONCLUSION: The overall response rate to CRT in CHD was 68%. Patients with systemic RV had a lower response rate to CRT when compared to patients with systemic LV. The total mortality rate after CRT implantation was 12%.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiopatias Congênitas , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Ecocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia
3.
J Cardiovasc Electrophysiol ; 35(4): 794-801, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38384108

RESUMO

INTRODUCTION: Several implantable cardioverter defibrillators (ICD) programming strategies are applied to minimize ICD therapy, especially unnecessary therapies from supraventricular arrhythmias (SVA). However, it remains unknown whether these optimal programming recommendations only benefit those with SVAs or have any detrimental effects from delayed therapy on those without SVAs. This study aims to assess the impact of SVA on the outcomes of ICD programming based on 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement and 2019 focused update on optimal ICD programming and testing guidelines. METHODS: Consecutive patients who underwent ICD insertion for primary prevention were classified into four groups based on SVA status and ICD programming: (1) guideline-concordant group (GC) with SVA, (2) GC without SVA, (3) nonguideline concordant group (NGC) with SVA, and (4) NGC without SVA. Cox proportional hazard models were analyzed for freedom from ICD therapies, shock, and mortality. RESULTS: Seven hundred and seventy-two patients (median age, 64 years) were enrolled. ICD therapies were the most frequent in NGC with SVA (24.0%), followed by NGC without SVA (19.9%), GC without SVA (11.6%), and GC with SVA (8.1%). Guideline concordant programming was associated with 68% ICD therapy reduction (HR 0.32, p = .007) and 67% ICD shock reduction (HR 0.33, p = .030) in SVA patients and 44% ICD therapy reduction in those without SVA (HR 0.56, p = .030). CONCLUSION: Programming ICDs in primary prevention patients based on current guidelines reduces therapy burden without increasing mortality in both SVA and non-SVA patients. A greater magnitude of reduced ICD therapy was found in those with supraventricular arrhythmias.


Assuntos
Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Arritmias Cardíacas , Morte Súbita Cardíaca/prevenção & controle
4.
Pacing Clin Electrophysiol ; 47(3): 353-364, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38212906

RESUMO

INTRODUCTION: Atrioventricular nodal reentrant tachycardia (AVNRT) is the most common supraventricular tachycardia referred for ablation. Periprocedural conduction system damage was a primary concern during AVNRT ablation. This study aimed to assess the incidence of permanent atrioventricular (AV) block and the success rate associated with different types of catheters in slow pathway ablation. METHOD: A literature search was performed to identify studies that compared various techniques, including types of radiofrequency ablation (irrigated and nonirrigated) and different sizes of catheter tip cryoablation (4, 6, and 8-mm), in terms of their outcomes related to permanent atrioventricular block and success rate. To assess and rank the treatments for the different outcomes, a random-effects model of network meta-analysis, along with p-scores, was employed. RESULTS: A total of 27 studies with 5110 patients were included in the analysis. Overall success rates ranged from 89.78% to 100%. Point estimation showed 4-mm cryoablation exhibited an odds ratio of 0.649 (95%CI: 0.202-2.087) when compared to nonirrigated RFA. Similarly, 6-mm cryoablation had an odds ratio of 0.944 (95%CI: 0.307-2.905), 8-mm cryoablation had an odds ratio of 0.848 (95%CI: 0.089-8.107), and irrigated RFA had an odds ratio of 0.424 (95%CI: 0.058-3.121) compared to nonirrigated RFA. CONCLUSION: Our study found no significant difference in the incidence of permanent AV block between the types of catheters. The success rates were consistently high across all groups. These findings emphasize the potential of both RF ablation (irrigated and nonirrigated catheter) and cryoablation as viable options for the treatment of AVNRT, with similar safety and efficacy profile.


Assuntos
Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular , Criocirurgia/métodos , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Ablação por Radiofrequência , Metanálise em Rede , Resultado do Tratamento , Bloqueio Atrioventricular , Ablação por Cateter/métodos , Desenho de Equipamento
5.
Ann Noninvasive Electrocardiol ; 29(3): e13113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563226

RESUMO

The anatomy of the His-Purkinje system has been studied, yet there remains a knowledge gap regarding the impact of His bundle pacing and its electrocardiographic implications. This case report highlights the presence of His-Purkinje system pathology without apparent clues on the surface electrocardiogram (EKG). By observing identical QRS morphology with varying HV intervals resulting from different pacing outputs, we demonstrate the presence of an electrical propagation block within the His bundle.


Assuntos
Fascículo Atrioventricular , Ramos Subendocárdicos , Humanos , Eletrocardiografia/métodos , Estimulação Cardíaca Artificial/métodos
6.
Indian Pacing Electrophysiol J ; 24(3): 123-129, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38218450

RESUMO

INTRODUCTION: While atrial fibrillation (AF) ablation has proven beneficial for heart failure (HF) patients, most reports were performed with radiofrequency ablation. We aimed to evaluate the efficacy and safety of cryoballoon AF ablation in patients with HFrEF. METHOD: We comprehensively searched the databases of MEDLINE, EMBASE, and Cochrane database from inception to December 2022. Studies that reported the outcomes of freedom from atrial arrhythmia, complications, NYHA functional class (NYHA FC), and left ventricular ejection fraction (LVEF) after Cryoballoon AF ablation in HF patients were included. Data from each study were combined with a random-effects model. RESULT: A total of 9 studies observational studies with 1414 HF patients were included. Five studies had only HF with reduced ejection fraction (HFrEF), 1 study with HF with preserved ejection fraction (HFpEF), and others with mixed HF types. Freedom from AA in HFrEF at 12 months was 64% (95% CI 56-71%, I2 58%). There was a significant improvement of LVEF in these patients with a standard mean difference of 13% (95% CI 8.6-17.5%, I2 99% P < 0.001. The complication rate in HFrEF group was 6% (95% CI 4-10%, I2 0%). The risk of recurrence of atrial arrhythmia was not significantly different between HF and no HF patients (RR 1.34, 95% CI 0.8-2.23, I2 76%). CONCLUSION: Cryoballoon AF ablation is effective in HFrEF patients comparable to radiofrequency ablation. The complication rate was low.

7.
J Cardiovasc Electrophysiol ; 34(10): 2086-2094, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37554118

RESUMO

INTRODUCTION: The concurrent data on sex disparities in VT management and outcomes have remained unclear. Therefore, our objective was to determine the impact of sex on ventricular tachycardia (VT) management and outcomes in patients admitted with VT, dervied from the US National Inpatient Sample database (NIS). METHODS: We used data from the US NIS to identify hospitalized adult patients who were admitted with VT between 2016 and 2018. Regression analysis was conducted to evaluate the impact of sex on VT management, in-hospital mortality, complications, length of stay, and hospitalization costs. RESULTS: Of the database, a total of 146 070 patients, who were primarily hospitalized for VT, were approximated. Among these, women comprised 25.5%; they were significantly younger and had fewer comorbidities. Of procedural aspects, women were less likely to receive an angiogram, mechanical support, implantable cardioverter-defibrillator implantation, and VT ablation compared to men. Notably, women were associated with higher do-not-resuscitate rates and in-hospital cardiac arrests than men. No differences in in-hospital mortality and cardiogenic shock were observed between men and women (p > .05). Length of stay was significantly longer for women, while no differences in hospital costs were observed in both sexes. CONCLUSION: Significant sex disparities in management and outcomes were observed in admitted patients with VT. Our results reflect the need for further studies to explore factors causing such diversities.

8.
J Cardiovasc Electrophysiol ; 34(4): 869-879, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36691892

RESUMO

BACKGROUND: High-power short-duration (HPSD) atrial fibrillation (AF) ablation with a power of 40-50 W was proved to be safe and effective. Very high-power short-duration (vHPSD) AF ablation is a novel method using >50 W to obtain more durable AF ablation. This study aimed to evaluate the efficacy and safety of vHPSD ablation compared with HPSD ablation and conventional power ablation. METHODS: A literature search for studies that reported AF ablation outcomes, including short-term freedom from atrial arrhythmia, first-pass isolation (FPI) rate, procedure time, and major complications, was conducted utilizing MEDLINE, EMBASE, and Cochrane databases. All relevant studies were included in this analysis. A random-effects model of network meta-analysis and surface under cumulative ranking curve (SUCRA) were used to rank the treatment for all outcomes. RESULTS: A total of 29 studies with 9721 patients were included in the analysis. According to the SUCRA analysis, HPSD ablation had the highest probability of maintaining sinus rhythm. Point estimation showed an odds ratio of 1.5 (95% confidence interval [CI]: 1.2-1.9) between HPSD ablation and conventional power ablation and an odds ratio of 1.3 (95% CI: 0.78-2.2) between vHPSD ablation and conventional power ablation. While the odds ratio of FPI between HPSD ablation and conventional power ablation was 3.6 (95% CI: 1.5-8.9), the odds ratio between vHPSD ablation and conventional power ablation was 2.2 (95% CI: 0.61-8.6). The procedure times of vHPSD and HPSD ablations were comparable and, therefore, shorter than that of conventional power ablation. Major complications were low in all techniques. CONCLUSION: vHPSD ablation did not yield higher efficacy than HPSD ablation and conventional power ablation. With the safety concern, vHPSD ablation outcomes were comparable with those of other techniques.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Metanálise em Rede , Resultado do Tratamento , Ablação por Cateter/métodos , Fatores de Tempo
9.
J Cardiovasc Electrophysiol ; 34(2): 382-388, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36423239

RESUMO

INTRODUCTION: Transseptal puncture (TSP) is routinely performed for left atrial ablation procedures. The use of a three-dimensional (3D) mapping system or intracardiac echocardiography (ICE) is useful in localizing the fossa ovalis and reducing fluoroscopy use. We aimed to compare the safety and efficacy between 3D mapping system-guided TSP and ICE-guided TSP techniques. METHODS: We conducted a prospective observational study of patients undergoing TSP for left atrial catheter ablation procedures (mostly atrial fibrillation ablation). Propensity scoring was used to match patients undergoing 3D-guided TSP with patients undergoing ICE-guided TSP. Logistic regression was used to compare the clinical data, procedural data, fluoroscopy time, success rate, and complications between the groups. RESULTS: Sixty-five patients underwent 3D-guided TSP, and 151 propensity score-matched patients underwent ICE-guided TSP. The TSP success rate was 100% in both the 3D-guided and ICE-guided groups. Median needle time was 4.00 min (interquartile range [IQR]: 2.57-5.08) in patients with 3D-guided TSP compared to 4.02 min (IQR: 2.83-6.95) in those with ICE-guided TSP (p = .22). Mean fluoroscopy time was 0.2 min (IQR: 0.1-0.4) in patients with 3D-guided TSP compared to 1.2 min (IQR: 0.7-2.2) in those with ICE-guided TSP (p < .001). There were no complications related to TSP in both group. CONCLUSIONS: Three-dimensional mapping-guided TSP is as safe and effective as ICE-guided TSP without additional cost.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Pontuação de Propensão , Átrios do Coração , Punções , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fluoroscopia , Resultado do Tratamento
10.
Cephalalgia ; 43(4): 3331024231161261, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36924253

RESUMO

BACKGROUND: A new migraine prevention, CGRP monoclonal antibodies (mAbs), is injectable on a monthly or quarterly basis. In clinical practice, some patients reported that drug effectiveness does not last until the upcoming scheduled injection, a so-called "wearing-off" effect. We aimed to evaluate the wearing-off effect of the CGRP mAbs for migraine prevention in patients with different monthly migraine days. METHODS: We conducted a literature search for studies that reported migraine frequency after CGRP monoclonal antibody administration from MEDLINE, SCOPUS, Web of Science, and Cochrane Database from inception through February 2022. A meta-analysis, random-effects model was applied to assess the difference in migraine frequency between early and later weeks after medication to assess the presence of a wearing-off effect. Risk ratio was calculated to report the pooled treatment effect. RESULTS: Four studies were entered for the analysis, comprising 2409 patients in randomized controlled trials. There was no association between CGRP mAbs and wearing-off effect in patients with galcanezumab with a pooled risk ratio of 1.29 (95% CI 0.73 to 2.28) compared to placebo group. However, there was an association between galcanezumab and wearing-off effect in patients with chronic migraine with a pooled risk ratio of 1.91 (95% CI 1.11 to 3.28) compared to placebo group. CONCLUSION: In this meta-analysis, there was a wearing-off efficacy of galcanezumab but only in a small percentage of patients with chronic migraine in randomized controlled trials.


Assuntos
Anticorpos Monoclonais , Transtornos de Enxaqueca , Humanos , Peptídeo Relacionado com Gene de Calcitonina , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Transtornos de Enxaqueca/tratamento farmacológico
11.
Artigo em Inglês | MEDLINE | ID: mdl-37932890

RESUMO

An 80-year-old man with a history of complete heart block underwent dual chamber pacemaker implantation about a year ago. He returned to the hospital due to de novo heart failure caused by pacing-induced cardiomyopathy; hence, we planned to upgrade his pacemaker to a biventricular device. The initial strategy was to perform left bundle branch area pacing-optimized cardiac resynchronization therapy (LOT-CRT) with left bundle branch area pacing (LBBAP) combined with a coronary sinus (CS) lead. In this challenging case, the successful placement of a CS lead was hindered by a complicated combination of a large CS body linked to the left superior vena cava and a winding CS branch. However, utilizing readily available tools, such as the coronary balloon and Guide Plus II ST catheter, proved instrumental in overcoming these obstacles. As a result, LOT-CRT provided the patient with a safe alternative to surgical LV lead placement.

12.
Pacing Clin Electrophysiol ; 46(12): 1604-1608, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37120827

RESUMO

INTRODUCTION: Transvenous pacemaker implantation in patients post bidirectional Glenn anastomosis in one-and-a-half ventricle repair is usually not feasible. However, with a modified surgical technique for Glenn anastomosis and a combined interventional and electrophysiologic approach, the transvenous pacemaker was successfully implanted. FINDINGS AND CONCLUSIONS: We reported a novel technique of pacemaker implantation in a 27-year-old woman, underlying Ebstein anomaly of the tricuspid valve, who developed intermittent complete atrioventricular block at 5 years after surgical repair. The patient had a tricuspid valve replacement and a novel modified bidirectional Glenn anastomosis for one-and-a-half ventricle repair. The Glenn circuit was conducted by opening a window between the posterior wall of the superior vena cava (SVC) and the anterior wall of the right pulmonary artery (RPA), combined with putting a Goretex membrane in the SVC below the SVC-RPA window without disconnecting the SVC from the right atrium. The transvenous pacemaker was implanted by perforating the Goretex membrane, then passing the leads from the axillary vein through the perforated membrane and placing them in the coronary sinus and right atrium.


Assuntos
Anomalia de Ebstein , Marca-Passo Artificial , Feminino , Humanos , Adulto , Anomalia de Ebstein/complicações , Anomalia de Ebstein/cirurgia , Valva Tricúspide/cirurgia , Veia Cava Superior , Resultado do Tratamento , Politetrafluoretileno
13.
Pacing Clin Electrophysiol ; 46(6): 459-466, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36633357

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) has recently become a promising option for the near-natural restoration of electrical activation. However, the clinical relevance of therapeutic effects in individuals with heart failure with reduced ejection fraction (HFrEF) and dyssynchrony remains unknown. METHODS: MEDLINE, EMBASE, and Cochrane databases were searched from inception until June 2022. Data from each study was combined using a random-effects model, the generic inverse variance method of DerSimonian and Laird, to calculate standard mean differences and pooled incidence ratio, with 95% confidence intervals (CIs). RESULTS: A total of 772 HFrEF patients were analyzed from 15 observational studies per protocol. The success rate of LBBAP implantation was 94.8% (95% CI 89.9-99.6, I2 = 79.4%), which was strongly correlated with shortening QRS duration after LBBAP implantation, with a mean difference of -48.10 ms (95% CI -60.16 to -36.05, I2 = 96.7%). Over a period of 6-12 months of follow-up, pacing parameters were stable over time. There were significant improvements in left ventricular ejection fraction (LVEF), left ventricular end-systolic volume (LVESV), left ventricular end-diastolic diameter (LVEDD), and left ventricular end-diastolic volume (LVEDV) with mean difference of 16.38% (95% CI 13.13-19.63, I2 = 90.2%), -46.23 ml (95% CI -63.17 to -29.29, I2 = 86.82%), -7.21 mm (95% CI -9.71 to -4.71, I2 = 84.6%), and -44.52 ml (95% CI -64.40 to -24.64, I2 = 85.9%), respectively. CONCLUSIONS: LBBAP was associated with improvements in both cardiac function and electrical synchrony. The benefits of LBBAP in individuals with HFrEF and dyssynchrony should be further validated by randomized studies.


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Estimulação Cardíaca Artificial/métodos , Volume Sistólico/fisiologia , Insuficiência Cardíaca/terapia , Remodelação Ventricular , Função Ventricular Esquerda , Resultado do Tratamento , Eletrocardiografia/métodos , Fascículo Atrioventricular
14.
Int J Mol Sci ; 24(5)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36902318

RESUMO

Over the last several years, the use of biomarkers in the diagnosis of patients with heart failure (HF) has skyrocketed. Natriuretic peptides are currently the most widely used biomarker in the diagnosis and prognosis of individuals with HF. Proenkephalin (PENK) activates delta-opioid receptors in cardiac tissue, resulting in a decreased myocardial contractility and heart rate. However, the goal of this meta-analysis is to evaluate the association between the PENK level at the time of admission and prognosis in patients with HF, such as all-cause mortality, rehospitalization, and decreasing renal function. High PENK levels have been associated with a worsened prognosis in patients with HF.


Assuntos
Insuficiência Cardíaca , Humanos , Prognóstico , Biomarcadores
15.
J Cardiovasc Electrophysiol ; 33(7): 1435-1449, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35589557

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly performed worldwide. As comfort with AF ablation increases, the procedure is increasingly used in patients that are older and in those with more comorbidities. However, it is not well established whether AF ablation in the elderly, especially those >75 years old, has comparable safety and efficacy to younger populations. OBJECTIVE: To compare the efficacy and safety profiles in patients older than 75 years undergoing AF ablation with younger patients. METHODS: Databases from EMBASE, Medline, PubMed, and Cochrane, were searched from inception through September 2021. Studies that compared the success rates in AF catheter ablation and all complications rates between patients who were older vs under 75 years were included. Effect estimates from the individual studies were extracted and combined using random effect, generic inverse variance method of DerSimonian and Laird. RESULTS: Twenty-seven observational studies were included in the analysis consisting of 363,542 patients who underwent AF ablation. Comparing patients older than 75 years old to younger patients, there was no difference in the success of ablation rates between elderly and younger patients (pooled OR 0.85: 95% CI:0.69-1.05, p = .131). On the other hand, AF ablation in the elderly was associated with higher complication rates (pooled OR 1.42: 95% CI:1.21-1.68, p < .001). CONCLUSION: As AF ablation is expanded to elderly populations, our study found that AF ablation success rates were similar in both elderly and younger patients. However, older patients experience higher rates of complications that should be considered when offering the procedure and as a means to improve outcomes with future innovations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 33(3): 401-411, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35018675

RESUMO

INTRODUCTION: Real-world data on atrial fibrillation (AF) ablation among moderate and advanced chronic kidney disease (CKD) patients have so far remained scarce, especially in-hospital AF ablation outcomes. METHODS: We drew data from the US National Inpatient Sample to identify hospitalized patients who underwent AF ablation between 2005 and 2018, and further stratified by CKD classification. We assessed the trend of AF ablation, as well as its complications. RESULTS: A total of 152 630 patients who were primarily hospitalized for AF and underwent ablation were estimated. Among these, CKD patients were found in a total of 1509 participants, with 978, 206, and 325 under CKD3, CKD4, and CKD5/ESKD, respectively. There was a significant increment in admission rates for AF ablation in the CKD population across all CKD classifications (p < .001). All CKD patients were statistically older, with higher coexisting comorbidities, while hypertension was found substantially lower than non-CKD patients (p ≤ .001). Importantly, CKD, especially CKD3 and CKD5/ESKD, was significantly associated with an increased risk of total complications, and total bleeding, Neurological complications were found statistically lower in CKD patients (p = .029), and no mortality rates were significantly different (p = .287). CONCLUSION: Our study observed an increase in admission trends for AF ablation among moderate and advanced CKD patients from 2005 to 2018. CKD was strongly associated with higher procedure-related complications and bleeding, but neurological safety profiles and mortalities rates were nonsignificantly different.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Renal Crônica , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Hospitais , Humanos , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fatores de Risco , Resultado do Tratamento
17.
Pacing Clin Electrophysiol ; 45(3): 393-400, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35000207

RESUMO

BACKGROUND: QRS area, a three-dimensional QRS complex, is a novel vectorcardiography method of measuring the magnitude of electrical forces in the heart. Hypothetically, a greater QRS area denotes higher dyssynchrony and indicates potential benefits from cardiac resynchronization therapy (CRT). Previous studies suggest a positive correlation between QRS area and the degree of response to CRT, but its clinical use remains unclear. We performed a meta-analysis of the relationship between QRS area and survival benefit following CRT. METHODS: We comprehensively searched the MEDLINE, EMBASE, and Cochrane databases from inception to August 2021. We included studies with prospective and retrospective cohort designs that reported QRS area before CRT and total mortality. Data from each study were analyzed using a random-effects model. The results were reported as a hazard ratio (HR) and 95% confidence intervals. RESULTS: Five observational studies including 4931 patients were identified. The cut-off values between large and small QRS areas ranged from 102 to 116 µVs. Our analysis showed a larger QRS area was statistically associated with increased 5-year survival in patients implanted with CRT (HR pooled 0.48, 95% CI 0.46-0.51, I2  = 54%, p < .0001). Greater QRS area reduction (pre- and post-implantation) were associated with a lower total mortality rate (HR pooled 0.45, 95% CI 0.38-0.52, I2  = 0%, p < .0001). CONCLUSION: Larger pre-implantation QRS area was associated with increased survival after CRT. QRS area reduction following CRT implantation was also associated with lower mortality. QRS area may potentially become an additional selection criterion for CRT implantations.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Vetorcardiografia/métodos
18.
Pacing Clin Electrophysiol ; 44(12): 2054-2066, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34657314

RESUMO

BACKGROUND: In the modern era, atrial fibrillation (AF) ablation trend has been shifted toward same-day discharge (SDD), from a traditional overnight stay. Yet, recent studies have not well stated the safety profiles which remained poor-understood and dispersed. We hence performed systematic review and meta-analysis to assess the adverse outcomes of SDD in comparison with an overnight stay. METHODS: Databases were searched through January 2021. Effect estimates from the individual studies were extracted and combined using random-effects, generic inverse variance method of der Simonian and Laird. The primary outcomes included total cumulative complications and immediate complications following AF ablation. RESULTS: Ten observational studies were met our inclusion criteria, comprising of total population of 11,660 patients, with SDD 51.3%. For total cumulative complications, there were no differences observed between SDD and overnight stay (5.2% vs. 6.2%: pooled OR 0.77: 95% CI 0.55-1.08, p = .13 with I2  = 27.1%). In addition, comparable immediate complications were also demonstrated (5.2 % vs. 4.3: pooled OR 1.08: 95% CI 0.72-1.62, p = .718, with I2  = 37.3 %). CONCLUSION: Our study suggested that SDD had similar complication rates, both total cumulative and immediate outcomes, compared with overnight stay in selected patients following AF ablation. Nevertheless, randomized control trials are warranted to validate the findings.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Tempo de Internação , Alta do Paciente , Humanos , Complicações Pós-Operatórias
19.
Curr Cardiol Rep ; 23(5): 54, 2021 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-33893882

RESUMO

PURPOSE OF REVIEW: To discuss the role of catheter ablation in treating life-threatening ventricular arrhythmias associated with Brugada syndrome (BrS), by presenting recent findings of BrS arrhythmogenic substrate, mechanisms underlying ventricular arrhythmias, and how they can be treated with catheter ablation. RECENT FINDINGS: Almost three decades ago when the clinical entity of Brugada syndrome (BrS) was described in patients who had abnormal coved-type ST elevation in the right precordial EKG leads in patients who had no apparent structural heart disease but died suddenly from ventricular fibrillation. Since its description, the syndrome has galvanized explosive research in this field over the past decades, driving major progress toward better understanding of BrS, gaining knowledge of the genetic pathophysiology and risk stratification of BrS, and creating significant advances in therapeutic modalities. One of such advances is the ability for electrophysiologists to map and identify the arrhythmogenic substrate sites of BrS, which serve as good target sites for catheter ablation. Subsequently, several studies have shown that catheter ablation of these substrates normalizes the Brugada ECG pattern and is very effective in eliminating these substrates and preventing recurrent VF episodes. Catheter ablation has become an important addition for treatment of symptomatic BrS patients with recurrent VT/VF episodes.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Síndrome de Brugada/cirurgia , Eletrocardiografia , Humanos , Fibrilação Ventricular
20.
Pacing Clin Electrophysiol ; 43(12): 1609-1611, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32696450

RESUMO

A 59-year-old female underwent a dual-chamber pacemaker implantation for intermittent complete heart block. A baseline electrocardiogram showed normal sinus rhythm with first-degree atrioventricular (AV) block and right bundle branch block. A His bundle lead placement was attempted. An intracardiac electrogram from the His bundle lead demonstrated atrial-His, and His-ventricular intervals were 186 and 110 ms, respectively. Pacing was performed from the His bundle lead with a decremental pacing output to assess for the His bundle capture threshold. However, there were no significant QRS morphology changes during the pacing. Is the His bundle captured? The tracing evaluation demonstrated the fascinating physiology of activation wavefront in His Purkinje system that could be applied in the use of conducting system pacing technologies.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/fisiopatologia , Eletrocardiografia , Feminino , Bloqueio Cardíaco/terapia , Humanos , Pessoa de Meia-Idade , Marca-Passo Artificial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA